973 resultados para Plasma. Dielectric barrier discharge. Lissajous figures. Optical emission spectroscopy


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Lead poisoning has been reportedly linked to a high risk of learning disabilities, aggression and criminal offenses. To study the association between lead exposure and antisocial/delinquent behavior, a cross-sectional study was conducted with 173 Brazilian youths aged 14\201318 and their parents (n = 93), living in impoverished neighborhoods of Bauru-SP, with high criminality indices. Self-Reported Delinquency (SRD) and Child Behavior Checklist (CBCL) questionnaires were used to evaluate delinquent/antisocial behavior. Body lead burdens were evaluated in surface dental enamel acid microbiopsies. The dental enamel lead levels (DELL) were quantified by graphite furnace atomic absorption spectrometry (GFAAS) and phosphorus content was measured using inductively coupled plasma optical emission spectrometry (ICP-OES). Logistic regression was used to identify associations between DELL and each scale defined by CBCL and SRD scores. Odd ratios adjusted for familial and social covariates, considering a group of youths exposed to high lead levels (\2265 75 percentile), indicated that high DELL is associated with increased risk of exceeding the clinical score for somatic complaints, social problems, rule-breaking behavior and externalizing problems (CI 95 per cent). High DELL was not found to be associated with elevated SRD scores. In conclusion, our data support the hypothesis that high-level lead exposure can trigger antisocial behavior, which calls for public policies to prevent lead poisoning

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The performance of laser-induced breakdown spectrometry (LIBS) for the determination of Ba, Cd, Cr and Pb in toys has been evaluated by using a Nd:YAG laser operating at 1064 nm and an Echelle spectrometer with intensified charge-coupled device detector. Samples were purchased in different cities of Sao Paulo State market and analyzed directly without sample preparation. Laser-induced breakdown spectrometry experimental conditions (number of pulses, delay time. integration time gate and pulse energy) were optimized by using a Doehlert design. Laser-induced breakdown spectrometry signals correlated reasonably well with inductively coupled plasma optical emission spectrometry (ICP OES) concentrations after microwave-assisted acid digestion of selected samples. Thermal analysis was used for polymer identification and scanning electron microscopy to Visualize differences in crater geometry of different polymers employed for toy fabrication. Results indicate that laser-induced breakdown spectrometry can be proposed as a rapid screening method for investigation of potentially toxic elements in toys. The unique application of laser-induced breakdown spectrometry for identification of contaminants in successive layers of ink and polymer is also demonstrated. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this work SiOxNy films are produced and characterized. Series of samples were deposited by the plasma enhanced chemical vapor deposition (PECVD) technique at low temperatures from silane (SiH4), nitrous oxide (N2O) and helium (He) precursor gaseous mixtures, at different deposition power in order to analyze the effect of this parameter on the films structural properties, on the SiOxNy/Si interface quality and on the SiOxNy effective charge density. In order to compare the film structural properties with the interface (SiOxNy/Si) quality and effective charge density, MOS capacitors were fabricated using these films as dielectric layer. X-ray absorption near-edge spectroscopy (XANES), at the Si-K edge, was utilized to investigate the structure of the films and the material bonding characteristics were analyzed through Fourier transform infrared spectroscopy (FTIR). The MOS capacitors were characterized by low and high frequency capacitance (C-V) measurements, in order to obtain the interface state density (D-it) and the effective charge density (N-ss). An effective charge density linear reduction for decreasing deposition power was observed, result that is attributed to the smaller amount of ions present in the plasma for low RF power. (C) 2008 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Free-piston-driven expansion tubes are capable of generating flaw conditions over a wide range of enthalpies ranging from orbital up to superorbital velocities. Initial optical measurements aimed at investigating the flow in such a facility are presented. Emission studies were used to identify impurities in the how and to investigate spectral regions that are accessible by optical techniques. At moderate enthalpies, it was found that significant radiation resulted from metallic contaminants. At high enthalpies, the spectrum consisted of a number of atomic lines together with a broadband background component indicative of the presence of electrons. The presence of this radiation may limit the applicability of optical techniques that require spectral regions free from the influence of atomic transitions or background radiation. Emission spectroscopy (through Stark broadened hydrogen lines) and two-wavelength holographic interferometry were used to measure the electron number density behind a bow shock on a blunt body at conditions where significant ionization was observed. They yielded average concentrations of (3 +/- 1) x 10(17) cm(-3) from the emission measurements and (3.8 +/- 0.6) x 10(17) cm(-3) from the interferometry.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In recent years, there has been increasing fish consumption in Brazil, largely due to the popularity of Japanese cuisine. No study, however, has previously assessed the presence of inorganic contaminants in species used in the preparation of Japanese food. In this paper, we determined total arsenic, cadmium, chromium, total mercury, and lead contents in 82 fish samples of Tuna (Thunnus thynnus), Porgy (Pagrus pagrus), Snook (Centropomus sp.), and Salmon (Salmo salar) species marketed in Sao Paulo (Brazil). Samples were mineralized in HNO(3)/H(2)O(2) for As, Cd, Cr and Pb, and in HNO(3)/H(2)SO(4)/V(2)O(5) for Hg. Inorganic contaminants were determined after the validation of the methodology using Inductively Coupled Plasma Optical Emission Spectrometry (ICP OES); and for Hg, an ICP-coupled hydride generator was used. Concentration ranges for elements analyzed in mg kg(-1) (wet base) were as follows: Total As (0.11-10.82); Cd (0.005-0.047); Cr (0.008-0.259); Pb (0.026-0.481); and total Hg (0.0077-0.9681). As and Cr levels exceeded the maximum limits allowed by the Brazilian law (1 and 0.1 mg kg(-1)) in 51.2 and 7.3% of the total samples studied, respectively. The most contaminated species were porgy (As = 95% and Cr = 10%) and tuna (As 91% and Cr = 10%). An estimation of As, Cd, Pb, and Hg weekly intake was calculated considering a 60 kg adult person and a 350 g consumption of fish per week, with As and Hg elements presenting the highest contribution on diets reaching 222% of provisional tolerable weekly intake (PTWI) for As in porgy and 41% of PTWI for Hg in tuna. (C) 2010 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: The purpose of the study was to investigate whether dentine irradiation with a pulsed CO(2) laser (10.6 mu m) emitting pulses of 10 ms is capable of reducing dentine calcium and phosphorus losses in an artificial caries model. Design: The 90 dentine slabs obtained from bovine teeth were randomly divided into six groups (n = 15): negative control group (GC); positive control group, treated with fluoride 1.23% (GF); and laser groups irradiated with 8 J/cm(2) (L8); irradiated as in L8 + fluoride 1.23% (L8F); irradiated with 11j/cm(2) (L11); irradiated as in L11 + fluoride 1.23% (L11F). After laser irradiation the samples were submitted to a pH-cycling model for 9 days. The calcium and phosphorous contents in the de- and remineralization solutions were measured by means of inductively coupled plasma optical emission spectrometer - ICP-OES. Additionally intra-pulpal temperature measurements were performed. The obtained data were analysed by means of ANOVA and Tukey`s test (alpha = 0.05). Results: In the demineralization solutions the groups L11F and GF presented significantly lower means of calcium and phosphorous losses than the control group; and in L11F means were significantly lower than in the fluoride group. Both irradiation parameters tested caused intrapulpal temperature increase below 2 degrees C. Conclusion: It can be concluded that under the conditions of this study, CO(2) laser irradiation (10.6 mu m) with 11J/cm(2) (540 mJ and 10 Hz) of fluoride treated dentine surfaces decreases the loss of calcium and phosphorous in the demineralization process and does not cause excessive temperature increase inside the pulp chamber. (C) 2010 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

O descarte ou reutilização da água produzida da indústria do petróleo é difícil por causa dos impactos ambientais causados devido à presença de alta salinidade e componentes tóxicos, ou pelo risco de obstrução nas colunas de produção devido à formação de incrustações que causam redução na produção de petróleo e enormes perdas no processo de extração. Assim, o conhecimento da composição química da água produzida é muito importante. O método proposto por este trabalho visa a determinação de elementos traço (Co, Cr, Fe, Mn, Ni, Se e V) em amostras de água produzida de petróleo por espectrometria de emissão óptica com plasma indutivamente acoplado (ICP OES) utilizando a digestão ácida assistida por micro-ondas para o preparo das amostras (15 g de amostra e 2 mL de HNO3 concentrado). A curva analítica construída em HNO3 2% v v-1 foi adotada para o método após verificar que não é necessário o uso de salinidade para equiparação de matriz. Para o elemento Ni, não há necessidade do uso de padrão interno, para os elementos Co, Cr, Fe, Mn e V os melhores resultados foram obtidos usando Sc como padrão interno. Para o elemento Se é recomendado o uso de Y como padrão interno. Os limites de detecção obtidos foram Co 0,67, Cr 1,2, Fe 2,3, Mn 0,49, Ni 1,9, Se 3,7 e V 5,5 μg L-1; e os limites de quantificação foram Co 2,2, Cr 4,0, Fe 7,7, Mn 1,6, Ni 6,5, Se 12,4 e V 18,3 μg L-1. A exatidão do procedimento foi verificada através de testes de recuperação em dois níveis de concentração (40 e 80 μg L-1) e análise dos materiais certificados de referência de água estuarina SLEW-2 e de água do mar NASS-5. Bons valores de recuperação foram obtidos e não houve diferença significativa (95% de confiança) entre os resultados obtidos e os valores certificados dos materiais de referência.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To analyze household risk factors associated with high lead levels in surface dental enamel. METHODS: A cross-sectional study was conducted with 160 Brazilian adolescents aged 14-18 years living in poor neighborhoods in the city of Bauru, southeastern Brazil, from August to December 2008. Body lead concentrations were assessed in surface dental enamel acid-etch microbiopsies. Dental enamel lead levels were measured by graphite furnace atomic absorption spectrometry and phosphorus levels were measured by inductively coupled plasma optical emission spectrometry. The parents answered a questionnaire about their children's potential early (05 years old) exposure to well-known lead sources. Logistic regression was used to identify associations between dental enamel lead levels and each environmental risk factor studied. Social and familial covariables were included in the models. RESULTS: The results suggest that the adolescents studied were exposed to lead sources during their first years of life. Risk factors associated with high dental enamel lead levels were living in or close to a contaminated area (OR = 4.49; 95% CI: 1.69;11.97); and member of the household worked in the manufacturing of paints, paint pigments, ceramics or batteries (OR = 3.43; 95% CI: 1.31;9.00). Home-based use of lead-glazed ceramics, low-quality pirated toys, anticorrosive paint on gates and/or sale of used car batteries (OR = 1.31; 95% CI: 0.56;3.03) and smoking (OR = 1.66; 95% CI: 0.52;5.28) were not found to be associated with high dental enamel lead levels. CONCLUSIONS: Surface dental enamel can be used as a marker of past environmental exposure to lead and lead concentrations detected are associated to well-known sources of lead contamination.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A study was carried out to evaluate the association of levels of radioactivity, selenium and aflatoxin in shelled Brazil nuts, which were classified in different sizes, for export. The selenium determinations were performed by inductively coupled plasma optical emission spectrometry (LOQ = 3.0 µg g-1), and aflatoxins were detected by Liquid chromatography-mass spectrometry (LOQ = 0.85 µg kg-1), recovery rates were between 92 and 100%. Radioactivity was measured by high-resolution gamma spectrometry. The selenium mean concentration was (22.7 ± 7.4) µg g-1. (n = 30). Mean activities determined for the following radium isotopes were: 15.77 Bq kg-1 for 224Ra, 104.8 Bq kg-1 for 226Ra and 99.48 Bq kg-1 for 228Ra. For 226Ra, the levels did not vary significantly with nut sizes, although such differences were observed for 224Ra and 228Ra. There was no statistically significant association between the level of selenium and the activity of radionuclides, however, there was correlation between the radionuclides. Aflatoxins above the quantification limit were not found.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Phytoplankton is important bioindicator of chemical and biological modifications of natural ecosystems. The objective of this study was to determine the total chemical composition of the phytoplankton of the Pará and Mocajuba estuaries on the eastern coast of the Amazon region in the Brazilian state of Pará. The chemical composition of the surface water, bottom sediments (total sample and bioavailable fraction), and the phytoplankton were determined by inductively coupled plasma optical emission spectrometry. Phytoplankton contained high concentrations of Ca, P, Mn, Fe, Zn, Al, Ba, and Pb. The phytoplankton of the Mocajuba estuary is rich in Fe (2,967-84,750 µg g-1), while those from the Pará is rich in Al (1,216-15,389 µgg-1), probably reflecting divergent anthropogenic inputs. Both samples indicated a high bioconcentration factor derived from both the water and the bioavailable fraction, reflecting the efficiency of these organisms in the concentration of metals.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dissertação de mestrado em Técnicas de Caracterização e Análise Química

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The variety of soils in the State of Acre is wide and their chemical profiles are still not fully understood. The nature of the material of origin of these soils is indicated by the high aluminium (Al) content, commonly associated with high calcium (Ca) and magnesium (Mg) contents. The study objective was to use different methods to quantify Al in soils from toposequences formed from material of a sedimentary nature originating from the Solimões Formation, in Acre, Brazil. Trenches were opened at three distinct points in the landscape: shoulder, backslope and footslope positions. Soil samples were collected for physical, chemical, mineralogical analyses. The Al content was quantified using different methods. High Al contents were found in most of these horizons, associated with high Ca and Mg levels, representing the predominant cations in the sum of exchangeable bases. The mineralogy indicates that the soils are still in a low weathering phase, with the presence of significant quantities of 2:1 minerals. Similar Al contents were determined by the methods of NaOH titration, xylenol orange spectrometry and inductively coupled plasma optical emission spectrometry. However, no consistent data were obtained by the pyrocatechol violet method. Extraction with KCl overestimated the exchangeable Al content due to its ability to extract the non-exchangeable Al present in the smectite interlayers. It was observed that high Al contents are related to the instability of the hydroxyl-Al smectite interlayers.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In comparison with other micronutrients, the levels of nickel (Ni) available in soils and plant tissues are very low, making quantification very difficult. The objective of this paper is to present optimized determination methods of Ni availability in soils by extractants and total content in plant tissues for routine commercial laboratory analyses. Samples of natural and agricultural soils were processed and analyzed by Mehlich-1 extraction and by DTPA. To quantify Ni in the plant tissues, samples were digested with nitric acid in a closed system in a microwave oven. The measurement was performed by inductively coupled plasma/optical emission spectrometry (ICP-OES). There was a positive and significant correlation between the levels of available Ni in the soils subjected to Mehlich-1 and DTPA extraction, while for plant tissue samples the Ni levels recovered were high and similar to the reference materials. The availability of Ni in some of the natural soil and plant tissue samples were lower than the limits of quantification. Concentrations of this micronutrient were higher in the soil samples in which Ni had been applied. Nickel concentration differed in the plant parts analyzed, with highest levels in the grains of soybean. The grain, in comparison with the shoot and leaf concentrations, were better correlated with the soil available levels for both extractants. The methods described in this article were efficient in quantifying Ni and can be used for routine laboratory analysis of soils and plant tissues.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Ydinvoimaloidenprimaarivesikierron puhdistukseen käytetään ioninvaihtohartsia. Käytönjälkeen ioninvaihtohartsi luokitellaan matalaja keskiaktiivisiin jätteisiin. Plasmakäsittelyllä käytetyn ioninvaihtohartsin tilavuutta voidaan pienentää sekä sen orgaaninen luonne poistaa. Plasmakäsittelyn tarkoituksena on hapettaa orgaaninen aines oksideiksi, jotka poistuvat prosessista savukaasuina. Epäorgaaninen aines, joka sisältää radioaktiivisen aineksen, on tarkoitus hapettaa oksideiksi ja sulfideiksi, jotka voidaan kerätä talteen tuhkana. Tässä diplomityössä käsitellään käytetyn ioninvaihtohartsin käsittelyyn suunnitellun plasmapolttoprosessin kehittämistä ja optimointia. Ioninvaihtohartsin plasmakäsittelyssä syntyvien reaktiotuotteiden selvittäminen suoritettiin tarkastelemalla ainetaseita sekä aihetta käsitteleviä tutkimuksia. Näiden perusteella parannettiin jäähdytystä, suunniteltiin jatkuvatoiminen syöttömenetelmä sekä laadittiin toimintaalueen reunaehdot laitteistolle. Koelaitteistossa 6,5 kW:n rfteho syötetään sovitinpiirin ja kuparisen induktiokelan kautta plasmaan. Plasmakaasuna on käytetty hapenja argonin seoskaasua. Plasmapolttoa on seurattu massaspektrometrilla, optisella emissiospektrometrilla, lämpösekä painemittareilla. Laskennan ja kokeiden pohjalta selvitettiin optimaalinen seossuhde plasmakaasulle, paineen ja tehon noston vaikutus hartsin polttonopeuteen sekä jatkuvatoimisen syöttömenetelmän edut panostoimiseen syöttöön. Rfgeneraattorin teho rajoitti jatkuvatoimisen polttonopeuden 130 g/h ja hetkellisen polttonopeuden 175 g/h. Radioaktiivisten aineiden pidätys oli 93,5 % cesiumin osalta. Tulosten perusteella 4 kg/h ioninvaihtohartsia polttavan laitteiston tehon lähteeksi tarvitaan 65 kW rfgeneraattori. Palamattoman hartsin ja tuhkan kulkeutuminen partikkelisuodattimille sekä reaktiotuotteena syntyvien rikinoksidien käsittely vaatii vielä jatkotutkimusta.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Chemical analysis is a well-established procedure for the provenancing of archaeological ceramics. Various analytical techniques are routinely used and large amounts of data have been accumulated so far in data banks. However, in order to exchange results obtained by different laboratories, the respective analytical procedures need to be tested in terms of their inter-comparability. In this study, the schemes of analysis used in four laboratories that are involved in archaeological pottery studies on a routine basis were compared. The techniques investigated were neutron activation analysis (NAA), X-ray fluorescence analysis (XRF), inductively coupled plasma optical emission spectrometry (ICP-OES) and inductively coupled plasma mass spectrometry (ICP-MS). For this comparison series of measurements on different geological standard reference materials (SRM) were carried out and the results were statistically evaluated. An attempt was also made towards the establishment of calibration factors between pairs of analytical setups in order to smooth the systematic differences among the results.