986 resultados para PRASEODYMIUM FLUORIDES
Resumo:
The aim of this study was to evaluate the ability of conventional toothpastes (1100 ppm F) supplemented with sodium trimetaphosphate (TMP) in demineralization. Blocks of enamel were selected and then divided into seven experimental groups of 12: toothpaste without F and TMP (placebo), toothpaste with 1100 ppm F (1100), and toothpaste with 1100 ppm F supplemented with TMP-1 % (1100 1 % TMP), 3 % (1100 3 % TMP), 4.5 % (1100 4.5 % TMP), 6 % (1100 6 % TMP), and 9 % (1100 9 % TMP). Blocks were subjected to five pH cycles (demineralizing/remineralizing solutions) at 37 °C and treated with toothpaste slurries twice daily, after which the blocks were maintained for 2 days in fresh remineralizing solution. Following treatments, surface hardness (SHf) and cross-sectional hardness were determined for calculating the integrated loss of subsurface hardness (ΔKHN). The fluoride present in the enamel was also measured. The SHf and ΔKHN measurements showed that supplementation with 3 % TMP was the most effective (p < 0.001) and showed greater concentration of F in the enamel (p < 0.001). Addition of 3 % TMP to a conventional toothpaste (1100 ppm F) showed greater efficacy in reducing enamel demineralization. Fluoride toothpastes containing trimetaphosphate possess good anticaries potential required to reduce the prevalence of dental caries in high-risk patients.
Resumo:
To evaluate the effect of a fluoride dentifrice containing sodium hexametaphosphate (HMP) on enamel demineralization in situ. This double-blind and cross-over study consisted of 3 phases (7 days each) in which 12 volunteers wore intraoral appliances containing four enamel bovine blocks. Specimens were treated (3×/day) with placebo (no F or HMP), 1100ppm F (1100F) and 1100F plus HMP1% (1100F-HMP1%) toothpastes, and the cariogenic challenge was performed using a 30% sucrose solution (6×/day). Final surface hardness, the percentage of surface hardness loss (%SH), the integrated loss of subsurface hardness (ΔKHN), as well as enamel calcium (Ca), phosphorus (P) and firmly-bound fluoride (F) were determined. Also, biofilm formed on the blocks were analyzed for F, Ca, P and insoluble extracellular polysaccharide (EPS) concentrations. Data were submitted 1-way ANOVA, followed by Student-Newman-Keuls' test (p<0.05). 1100F-HMP1% promoted the lowest %SH and ΔKHN among all groups (p<0.001). The addition of HMP1% to 1100F did not enhance enamel F uptake, but significantly increased enamel Ca concentrations (p<0.001). Similar EPS concentrations were seen for 1100F-HMP1% and 1100F groups (p>0.05). All the groups were supersaturated with respect to HA. However, only 1100F-HMP1% group was supersaturated with respect to CaF2 (p<0.05). The ionic activities of F(-), CaF(+) and HF(0) for the 1100F-HMP1% group were the highest among all groups (p<0.001). The addition of HMP1% to a conventional toothpaste significantly reduces enamel demineralization in situ when compared to 1100F. This dentifrice could be a viable alternative to patients at high risk of caries.
Resumo:
This study evaluated the effect of fluoride gels, supplemented or not with sodium hexametaphosphate (HMP), on enamel erosive wear in situ. Twelve healthy volunteers wore palatal appliances containing four bovine enamel discs. Subjects were randomly allocated into four experimental phases (double-blind, crossover protocol) according to the gels: Placebo (no fluoride or HMP), 1% NaF, 2% NaF, and 1% NaF+9% HMP. Enamel discs were selected after polishing and surface hardness analysis, and treated only once with the respective gels prior to each experimental phase. Erosion (ERO) was performed by extra-oral immersion of the appliance in 0.05M citric acid, pH 3.2 (four times/day, five minutes each, 5 days). Additional abrasion (ERO+ABR) was produced on only two discs by toothbrushing with fluoridated dentifrice after ERO (four times/day, 30s, 5 days). The specimens were submitted to profilometry and hardness analysis. The results were analyzed by two-way ANOVA and the Student-Newman-Keuls test (p<0.05). The 1% NaF+9% HMP gel promoted significantly lower enamel wear for ERO compared to the other groups, being statistically lower than 1% NaF and Placebo for ERO+ABR. Similarly, the lowest values of integrated lesion area were found for 1% NaF+9% HMP and 2% NaF, respectively, for ERO and ERO+ABR. The addition of HMP to the 1% NaF gel promoted greater protective effect against ERO and ERO+ABR compared to the 1% NaF gel, achieving similar protective levels to those seen for the 2% NaF gel. Gel containing 1% NaF+9% HMP showed a high anti-erosive potential, being a safer alternative when compared to a conventional 2% NaF gel.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Objective: The objective of this study was to evaluate the effect of Er: YAG laser on the formation of CaF2, after the application of acidulated phosphate fluoride (APF), and its influence on the anti-cariogenic action in human dental enamel. Background Data: Er:YAG laser was designed to promote ablation of the enamel. However, the possibility of using this energy to increase the enamel's resistance to caries has hardly been explored, and neither has its interaction with the use of fluorides. Materials and Methods: One hundred and twenty blocks of enamel were allocated to four groups of 30 blocks each: (1) C, control group; (2) Er:YAG, laser; (3) APF; and (4) Er:YAG+APF. Of these, 80 blocks were submitted to pH cycling for 14 days. In the other 40 blocks, fluoride (CaF2) was measured before cycling. After pH cycling, surface microhardness (SMH), microhardness in cross-section (converted to mineral contents % vol. min.), and fluoride after cycling (40 blocks) were also determined. Results: SMH decreased in all groups. The control group showed the highest decrease, and Er:YAG+APF showed the lowest decrease (p < 0.05). Groups APF and Er:YAG showed the same results (p > 0.05). Mineral content at depths 10, 20, and 40 μm was lower in the control and Er:YAG groups, and higher in groups APF and Er:YAG+APF. CaF2 (μgF/cm2) deposited before pH cycling was higher in the APF group when compared to the Er:YAG+APF group. Control and Er:YAG groups showed the lowest values (p > 0.05). Conclusion: It was concluded that Er:YAG laser influenced the deposition of CaF2 on the enamel and showed a superficial anti-cariogenic action, but not in depth.
Resumo:
Fluoridation of water for human consumption is a method of caries prevention that brings great social benefit, if kept at optimal levels. The increase in the production of bottled water emphasizes the need to verify whether fluoride presence in these waters occurs in sufficient quantity to prevent decay, or if it represents a significant risk of fluorosis. Objective: to compare the concentrations of fluoride present in bottled water to those declared on the labels, and to make a critical analysis of legal norms on the subject. Materials and method: this was a cross-sectional study, through which 22 samples of bottled water sold in state of Ceará, Brazil, were analyzed. Analyses were performed in duplicate by the electrometric method, and results were compared to those printed on the labels. Detailed searches by laws, resolutions, ordinances, and other official documents in force, related to the topic were performed. Results: the fluoride concentrations found ranged from 0.01 to 0.36 mgF/l. Although 72.7% of the samples were classified as fluoridated, the fluoride concentrations observed were shown to be insufficient for caries prevention. As for the rules, situations where they are not clear or even divergent were found. Conclusion: the current legislation on the subject requires updates to become more objective and to create new criteria on the use of the term “fluoridated water”.
Resumo:
This in vitro study evaluated the demineralization around restorations class V made on the buccal and lingual surfaces of teeth when using different restorative materials. Thirty extracted teeth were randomly divided into 3 groups (n=10) according to the restorative material: Group I - Fuji II LC (GC America Inc., Alsip, Illinois, USA), Group II - Tetric (Ivoclar Vivadent AG, Schaan, Liechtenstein) and Group III - Chelon Fil (3M/ESPE., Seefeld, Germany). The teeth were submitted to a pH-cycling model associated to a thermocycling model. Sections were made and the specimens were analyzed under a polarized light microscopy as for the presence of demineralization. Measurements were performed and the results were subjected to statistical analysis using Anova and Tukey´s Test (α=0.05). Mean values of demineralization depth (µm) according to each positions showed that the demineralization was significantly reduced when Chelon Fil (Group III) was used for all depths, when compared to fluoridated resin materials. Also, it was verified that non-fluoridated resin material, composite resin Tetric, had the lowest inhibitory effect on the development of demineralization.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
This work describes the synthesis of five O-silyloxy-1,3-thiazoles and their use as fast-response turn-on probes for fluoride ion detection in polar aprotic solvents and in aqueous cetyltrimethylammonium bromide micellar medium. The fluoride-triggered deprotection of these silyl ethers results in ca. 180-nm shifts in the fluorescence emission wavelengths. All compounds are suitable for the detection of fluoride ions with a detection limit in DMSO of 107 mol?L1; derivatives containing a 2-pyridyl moiety in the thiazole system are more efficient than those with a 3- or 4-pyridyl moiety. Typical anionic interferents, such as acetate or chloride, are not detected by O-silyloxy-1,3-thiazoles, making these compounds very specific for fluoride.
Resumo:
Objectives: To conduct a controlled study contrasting titanium surface topography after procedures that simulated 10 years of brushing using toothpastes with or without fluoride. Methods: Commercially pure titanium (cp Ti) and Ti-6Al-4V disks (6 mm circle divide x 4 mm) were mirror-polished and treated according to 6 groups (n = 6) as a function of immersion (I) or brushing (B) using deionised water (W), fluoride-free toothpaste (T) and fluoride toothpaste (FT). Surface topography was evaluated at baseline (pretreatment) and post-treatment, using atomic force microscope in order to obtain three-dimensional images and mean roughness. Specimens submitted to immersion were submerged in the vehicles without brushing. For brushed specimens, procedures were conducted using a linear brushing machine with a soft-bristled toothbrush. Immersion and brushing were performed for 244 h. IFT and BFT samples were analysed under scanning electron microscope with Energy-Dispersive X-ray Spectroscopy (EDS). Pre and post-treatment values were compared using the paired Student T-test (alpha = .05). Intergroup comparisons were conducted using one-way ANOVA with Tukey post-test (alpha = .05). Results: cp Ti mean roughness (in nanometers) comparing pre and post-treatment were: IW, 2.29 +/- 0.55/2.33 +/- 0.17; IT, 2.24 +/- 0.46/2.02 +/- 0.38; IFT, 2.22 +/- 0.53/1.95 +/- 0.36; BW, 2.22 +/- 0.42/3.76 +/- 0.45; BT, 2.27 +/- 0.55/16.05 +/- 3.25; BFT, 2.27 +/- 0.51/22.39 +/- 5.07. Mean roughness (in nanometers) measured in Ti-6Al-4V disks (pre/post-treatment) were: IW, 1.79 +/- 0.25/2.01 +/- 0.25; IT, 1.61 +/- 0.13/1.74 +/- 0.19; IFT, 1.92 +/- 0.39/2.29 +/- 0.51; BW, 2.00 +/- 0.71/2.05 +/- 0.43; BT, 2.37 +/- 0.86/11.17 +/- 2.29; BFT, 1.83 +/- 0.50/15.73 +/- 1.78. No significant differences were seen after immersions (p > .05). Brushing increased the roughness of cp Ti and of Ti-6Al-4V (p < .01); cp Ti had topographic changes after BW, BT and BFT treatments whilst Ti-6Al-4V was significantly different only after BT and BTF. EDS has not detected fluoride or sodium ions on metal surfaces. Conclusions: Exposure to toothpastes (immersion) does not affect titanium per se; their use during brushing affects titanium topography and roughness. The associated effects of toothpaste abrasives and fluorides seem to increase roughness on titanium brushed surfaces. (C) 2012 Elsevier Ltd. All rights reserved.
Resumo:
Barium praseodymium tungstate (Ba1-xPr2x/3)WO4 crystals with (x = 0, 0.01, and 0.02) were prepared by the coprecipitation method. These crystals were structurally characterized by X-ray diffraction (XRD), Rietveld refinements, Fourier-transform Raman (FT-Raman) and Fourier-transform infrared (FT-IR) spectroscopies. The shape and size of these crystals were observed by field emission scanning electron microcopy (FE-SEM). Their optical properties were investigated by ultraviolet visible (UV-vis) absorption and photoluminescence (PL) measurements. Moreover, we have studied the photocatalytic (PC) activity of crystals for degradation of rhodamine B (RhB) dye. XRD patterns, Rietveld refinements data, FT-Raman and FT-IR spectroscopies indicate that all crystals exhibit a tetragonal structure without deleterious phases. FT-Raman spectra exhibited 13 Raman-active modes in a range from 50 to 1000 cm(-1), while FT-IR spectra have 8 infrared active modes in a range from 200 to 1050 cm(-1). FE-SEM images showed different shapes (bonbon-, spindle-, rice-and flake-like) as well as a reduction in the crystal size with an increase in Pr3+ ions. A possible growth process was proposed for these crystals. UV-vis absorption measurements revealed a decrease in optical band gap values with an increase of Pr3+ into the matrix. An intense green PL emission was noted for (Ba1-xPr2x/3)WO4 crystals (x = 0), while crystals with (x = 0.01 and 0.02) produced a reduction in the wide band PL emission and the narrow band PL emission which is related to f-f transitions from Pr3+ ions. High photocatalytic efficiency was verified for the bonbon-like BaWO4 crystals as a catalyst in the degradation of the RhB dye after 25 min under UV-light. Finally, we discuss possible mechanisms for PL and PC properties of these crystals.
Resumo:
Fluoridation of the public water supplies is recognized as among the top ten public health achievements of the twentieth century. However, the positive aspects of this measure depend on the maintenance of fluoride concentrations within adequate levels. To report the results of seven years of external control of the fluoride (F) concentrations in the public water supply in Bauru, SP, Brazil in an attempt to verify, on the basis of risk/benefit balance, whether the levels are appropriate. From March 2004 to February 2011, 60 samples were collected every month from the 19 supply sectors of the city, totaling 4,641 samples. F concentrations in water samples were determined in duplicate, using an ion-specific electrode (Orion 9609) coupled to a potentiometer after buffering with TISAB II. After the analysis, the samples were classified according to the best risk-benefit adjustment. Means (±standard deviation) of F concentrations ranged between 0.73±0.06 and 0.81±0.10 mg/L for the different sectors during the seven years. The individual values ranged between 0.03 and 2.63 mg/L. The percentages of the samples considered “low risk” for dental fluorosis development and of “maximum benefit” for dental caries prevention (0.55-0.84 mg F/L) in the first, second, third, fourth, fifth, sixth, and seventh years of the study were 82.0, 58.5, 37.4, 61.0, 89.9, 77.3, and 72.4%, respectively, and 69.0% for the entire period. Fluctuations of F levels were found in the public water supply in Bauru during the seven years of evaluation. These results suggest that external monitoring of water fluoridation by an independent assessor should be implemented in cities where there is adjusted fluoridation. This measure should be continued in order to verify that fluoride levels are suitable and, if not, to provide support for the appropriate adjustments
Resumo:
The effects of fluoride, which is present in different oral hygiene products, deserve more investigation because little is known about their impact on the surface of titanium, which is largely used in Implantology. This study evaluated the surface of commercially pure titanium (cpTi) after exposure to different concentrations of sodium fluoride (NaF). The hypothesis tested in this study was that different concentrations of NaF applied at different time intervals can affect the titanium surface in different ways. The treatments resulted in the following groups: GA (control): immersion in distilled water; GB: immersion in 0.05% NaF for 3 min daily; GC: immersion in 0.2% NaF for 3 min daily; GD: immersion in 0.05% NaF for 3 min every 2 weeks; and GE: immersion in 0.2% NaF for 3 min every 2 weeks. The experiment lasted 60 days. Roughness was measured initially and every 15 days subsequently up to 60 days. After 60 days, corrosion analysis and anodic polarization were done. The samples were examined by scanning electron microscopy (SEM). The roughness data were analyzed by ANOVA and there was no significant difference among groups and among time intervals. The corrosion data (i corr) were analyzed by the Mann-Whitney test, and significant differences were found between GA and GC, GB and GC, GC and GD, GC and GE. SEM micrographs showed that the titanium surface exposed to NaF presented corrosion that varied with the different concentrations. This study suggests that the use of 0.05% NaF solution on cpTi is safe, whereas the 0.2% NaF solution should be carefully evaluated with regard to its daily use.
Resumo:
Im Rahmen der vorliegenden Arbeit wurden eine Vielzahl optisch aktiver 1,2,6-trisubstituierte Piperidine stereoselekiv dargestellt. Bei der anschließenden Aza-Claisen-Umlagerunge wurden daraus chirale Azecinone (zyklische, ungesättigte, zehngliedrige Lactame) gebildet, die sich für die Totalsynthese u. a. von Clavepictin A eignen.rnrnDazu wurde zunächst über eine weitere zwitterionische Aza-Claisen-Umlagerung ein Dien aufgebaut, welches durch intramolekulare Grubbs-Metathese zum Piperidin geschlossen werden konnte. Daraus wurde ein Baikiain- sowie ein Pipecolinsäure-Derivat hergestellt.rnrnAuf einem weiteren Weg zu hochsubstituierten Piperidinen wurde eine von Katritzky et al. erarbeitete Synthese eines Bisaminals auf ihre Flexibilität bezüglich des Substitutionsmusters in 2- und 6-Position am Piperidinring durch eine Kaskade an Reduktionen und Grignard-Reaktionen zu stereoselektiv trisubstituierten 2-Vinyl-Piperidinen untersucht. rnrnDie anschließende zwitterionische Aza-Claisen-Umlagerung an diesen Vinyl-Piperidinen mit verschiedenen Säurefluoriden diente jeweils zur Überprüfung der Tauglichkeit der ausgewählten Reaktionswege zur Totalsynthese von Clavepictin. Durch Strukturbestimmung der gebildeten Azecinone mittels NOESY wurde der erwartete Chiralitätstransfer bei der Umlagerungsreaktion untersucht bzw. bestätigt.rnrnNebenbei wurde dabei ein Chinolizidin-Derivat gefunden, dessen Darstellung durch eine neuartige Dominoreaktion erklärt wurde und dessen Grundstruktur einen weiteren und ggf. kürzeren Syntheseweg zu Clavepictin A und seinen Derivaten zulassen sollte. rn
Resumo:
Die Analyse optischer Spektren liefert einen kernmodellunabhängigen Zugang zur Bestimmung der Kernspins, Ladungsradien und elektromagnetischen Momente von Atomkernen im Grundzustand und von langlebigen Isomeren. Eine der vielseitigsten Methoden zur optischen Spektroskopie an kurzlebigen Isotopen ist die kollineare Laserspektroskopie. Im Rahmen dieser Arbeit wurde zum einen die TRIGA-LASER Strahlstrecke am Institut für Kernchemie der Universität Mainz durch die Implementierung einer neuen offline Oberflächenionenquelle für hohe Verdampfungstemperaturen und eines Strahlanalysesystems weiterentwickelt. Zum anderen wurde kollineare Laserspektroskopie an kurzlebigen Praseodym- und Cadmiumisotopen an ISOLDE/CERN durchgeführt. Die neue Ionenquelle ermöglichte dabei den Test der kollinearen Laserspektroskopie an Praseodymionen am TRIGA-LASER Experiment. Die Spektroskopie der Prasdeodymionen motivierte sich aus der Beobachtung einer zeitlichen Modulation der EC-Zerfallsrate von wasserstoffähnlichem 140Pr58+. Für die Erklärung dieser sogenannten GSI Oszillationen wird unter anderem das magnetische Moment des Kerns benötigt, welches bislang noch nicht experimentell bestimmt wurde. Zudem wurde für wasserstoffähnliches 140Pr58+ überraschenderweise eine kleinere EC-Zerfallskonstante gemessen als für heliumähnliches 140Pr57+. Die Erklärung dieses Phänomens setzt ein positives magnetisches Moment voraus. Bei der Spektroskopie am COLLAPS Experiment wurden erstmals die magnetischen Momente von 135Pr, 136Pr und 137Pr vermessen. Aufgrund zu geringer Produktionsraten war die Spektroskopie des gewünschten Isotops 140Pr jedoch nicht erfolgreich. Die Untersuchung der Cadmiumisotope ist kernphysikalisch motiviert. In der Zinnregion erstrecken sich die Isotope über die beiden magischen Zahlen N=50 und N=82 bei gleichzeitiger Nähe des Z=50 Schalenabschlusses. Hier können verschiedene Kernmodelle getestet werden, die sich beispielsweise hinsichtlich der Stärke des N=82 Schalenabschlusses widersprechen. Diese Arbeit berichtet über erste Ergebnisse der Spektroskopie an Cadmiumatomen, die sich über die Isotope 106−124,126Cd sowie die zugehörigen langlebigen I=11/2− Isomere erstreckt. Die zuvor experimentell bekannten oder aus dem erweiterten Schalenmodell abgeleiteten Kernspins konnten für alle Isotope bis auf 119Cd bestätigt werden. Der Kernspin von 119Cd wurde eindeutig zu I=1/2 bestimmt. Die elektrischen Quadrupolmomente der Isomere zeigen ein bemerkenswert lineares Verhalten in Abhängigkeit von der Neutronenzahl und dies über die eigentliche Kapazität der 1h11/2 Unterschale hinaus. Die Änderungen der mittleren quadratischen Ladungsradien zeigen den auch an Indium- und Zinnisotopen beobachteten stetigen Verlauf. Der lineare Anteil passt sehr gut zu den Berechnung des Tröpfchenmodells in der Parametrisierung nach Berchidevsky und Tondeur. Die Differenzen der mittleren quadratischen Ladungsradien zwischen Grund- und isomeren Zustand der ungeraden Cadmiumisotope zeigen einen interessanten parabolischen Verlauf mit einem Minimum zwischen A=117 und A=119.