984 resultados para Oral Medicine


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective. The objective of this study was to evaluate the immunolocalization of bone morphogenetic protein 2 (BMP-2) after autogenous block grafting covered or not with an e-PTFE membrane. Study Design. Forty-eight rats were divided into 2 groups, autogenous block graft (B) and autogenous block graft + e-PTFE membrane (MB), and were evaluated by immunohistochemistry at baseline and 3, 7, 14, 21, and 45 days. Results. The largest number of positive cells in the recipient bed was observed after 3 days in both groups. At the graft border, the largest number of positive cells was seen after 7 days in group B and after 14 days in group MB. The highest proportion of staining in the graft was observed after 3 days in group B and after 21 days in group MB. Conclusions. High proportions of stain were related to intense revascularization and osteogenesis. Except for the interface, BMP-2 staining occurred later in group MB than in group B in all structures analyzed. (Oral Surg Oral Med Oral Pathol Oral Radiol 2012;113:533-541)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective. The objective of this preliminary study was to evaluate the expression of matrix metalloproteinases (MMPs), tissue inhibitors of metalloproteinases (TIMPs) and growth factors in keratocystic odontogenic tumors (KOTs). Study Design. The expression of MMPs, TIMPs, growth factors, and the extracellular signal-regulated kinase (ERK) 1/2 signaling pathway were assessed by immunohistochemistry in 15 cases of KOT and 4 cases of calcifying cystic odontogenic tumor (CCOT). Results. KOT samples expressed significantly higher amounts of MMPs, TIMPs, growth factors, epidermal growth factor receptor (EGFR), and ERK compared with CCOT samples, with the exception of MMP-2 and TIMP-1. Conclusions. MMP-9, TIMP-2, EGF and transforming growth factor alpha act together and likely regulate the proliferation and aggressiveness of KOT. ERK-1/2 serves as the transducer of signals generated by these proteins, which signal through the common receptor, EGFR. This process may be related to the increased proliferation and aggressiveness observed in KOT. (Oral Surg Oral Med Oral Pathol Oral Radiol 2012;114:487-496)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective. The aim of this study was to evaluate the need for antibiotic prescription in third molar surgery. Study design. A double-blind randomized study was carried out with 71 patients from CODONT (Dentistry Center of the Police of Sao Paulo). Amoxicillin, clindamycin, or no medication was administered for 7 days immediately after surgery. The participants evaluated the presence of pain, edema, interincisal distance (ID), presence of infection, Pell and Gregory classification, rescue analgesia, osteotomy, and odontosection. Results. There was no difference (P < .05) between antibiotics and control over the surgery duration, dose, visual analog scale (VAS), ID, and edema, yet significant differences were seen over time for VAS, edema, and ID. Conclusions. Antibiotic prescription should not be indicated in all clinical conditions, yet it is necessary to correctly evaluate factors such as systemic condition of the patient, skill of the operator, and contamination of the surgical environment. (Oral Surg Oral Med Oral Pathol Oral Radiol 2012; 114(suppl 5):S26-S31)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective. Patients (n = 110) free of antibiotics, operated on by 3 surgeons ranging in clinical experiences, were evaluated for infection. Study Design. In the preoperative period and during the second and seventh postoperative days, the following parameters were analyzed: pain, infection, swelling, trismus, body temperature, C-reactive protein levels (CRP), and salivary neutrophil counts (SNC). During surgery, the following parameters were analyzed: systolic, diastolic, and mean arterial pressure; oximetry; heart rate; anesthesia quality; local anesthetic amount; bleeding; surgery difficulty; and surgery duration. Results. There were some differences in the surgery duration, local anesthetic amount, anesthesia quality, bleeding, pain experienced, trismus, CRP, and SNC, and no changes in hemodynamic parameters, rescue analgesic medication, wound healing, swelling, body temperature, confirmed case of dry socket, or any other type of local infection. Particularly, no systemic infections were found after lower third molar removal (LTMR). Conclusions. This study suggests that antibiotic prescriptions are unnecessary after LTMR when preoperative infections are absent. (Oral Surg Oral Med Oral Pathol Oral Radiol 2012;114(suppl 5):S199-S208)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective. Lower third molar removal provides a clinical model for studying analgesic drugs. The present study's aim was to compare the clinical efficacy of sublingual ketorolac and sublingual piroxicam in managing pain, trismus and swelling after lower third molar extraction in adult volunteers. Study Design. In this double-blinded, randomized, crossover investigation, 47 volunteers received for 4 days ketorolac sublingually (10 mg 4 times daily) and piroxicam sublingually (20 mg once daily) during 2 separate appointments after lower third molar extraction of symmetrically positioned lower third molars. A surgeon evaluated objective parameters (surgery duration, mouth opening, rescue analgesic medication, and facial swelling) and volunteers documented subjective parameters (postoperative pain and global evaluation), comparing postoperative results for a total of 7 days after surgery. The means of the objective and subjective parameters were compared for statistical significance (P < .05). Results. Volunteers reported low pain scores during the postoperative period when treated with either sublingual ketorolac or piroxicam. Also, volunteers ingested similar amounts of analgesic rescue medication (paracetamol) when they received either drug sublingually (P > .05). Additionally, values for mouth openings measured just before surgery and immediately after suture removal 7 days later were similar among volunteers (P > .05), and the type of nonsteroidal antiinflammatory drug (NSAID) used in this study showed no significant differences between swellings on the second or seventh days after surgery (P > .05). Conclusions. Pain, trismus, and swelling after lower third molar extraction, independent of surgical difficulty, were successfully controlled by sublingual ketorolac (10 mg 4 times daily) or sublingual piroxicam (20 mg once daily), and no significant differences were observed between the NSAIDs evaluated. (Oral Surg Oral Med Oral Pathol Oral Radiol 2012;114:27-34)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Despite its importance, implant removal torque can be assessed at present only after implantation. This paper presents a new technique to help clinicians preoperatively evaluate implant stability.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The present study validated the accuracy of data from a self-reported questionnaire on smoking behaviour with the use of exhaled carbon monoxide (CO) level measurements in two groups of patients. Group 1 included patients referred to an oral medicine unit, whereas group 2 was recruited from the daily outpatient service. All patients filled in a standardized questionnaire regarding their current and former smoking habits. Additionally, exhaled CO levels were measured using a monitor. A total of 121 patients were included in group 1, and 116 patients were included in group 2. The mean value of exhaled CO was 7.6 ppm in the first group and 9.2 ppm in the second group. The mean CO values did not statistically significantly differ between the two groups. The two exhaled CO level measurements taken for each patient exhibited very good correlation (Spearman's coefficient of 0.9857). Smokers had a mean difference of exhaled CO values of 13.95 ppm (p < 0.001) compared to non-smokers adjusted for the first or second group. The consumption of one additional pack year resulted in an increase in CO values of 0.16 ppm (p = 0.003). The consumption of one additional cigarette per day elevated the CO measurements by 0.88 ppm (p < 0.001). Based on these results, the correlations between the self-reported smoking habits and exhaled CO values are robust and highly reproducible. CO monitors may offer a non-invasive method to objectively assess current smoking behaviour and to monitor tobacco use cessation attempts in the dental setting.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVE: To find out whether conventional periapical radiographs can be used to determine the risk of creating an oroantral communication (OAC) while performing periapical surgery on maxillary premolars and molars. STUDY DESIGN: One hundred thirteen periapical radiographs of maxillary premolars and molars with periapical radiolucencies indicating chronic apical periodontitis were retrospectively analyzed and classified. The surgery reports were evaluated for occurrence of perforation of the maxillary sinus and postoperative complications. RESULTS: Perforation of the sinus membrane (also referred to as the Schneiderian membrane) occurred in 12 cases (9.6%). Exposure of the membrane without rupture occurred in 15 cases (12%). It was found that the distance between the apex or the periapical lesion and the sinus floor did not serve as a predictor of a possible sinus membrane rupture. On the other hand, if the radiograph showed a distinct distance between the lesion and the sinus floor, there was an 82.5% probability that OAC would not occur. Additionally, a blurred radiographic outline of the periapical lesion did not indicate an increased risk of sinus membrane rupture. CONCLUSION: Conventional periapical radiographs cannot be used as predictors for perforation of the maxillary sinus during periapical surgery. However, radiographs with a specific distance between the periapical lesion and the sinus floor point toward a very low risk of accidental sinus perforation during periapical surgery.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVES: To compare the outcome of arthroscopic lysis and lavage of TMJ with internal derangement of Wilkes stages II, III, IV, and V. STUDY DESIGN: Arthroscopic lysis and lavage was performed in 45 TMJ of 39 patients with internal derangement. The cases were divided into 4 groups corresponding to Wilkes stages II, III, IV, and V. Two parameters were compared pre- and postoperatively: pain and mouth opening. Statistical significance was determined using the chi(2) test. RESULTS: Overall success rate was 86.7% (Wilkes stage II 90.9%, Wilkes stage III 92.3%, Wilkes stage IV 84.6%, Wilkes stage V 75%). There were no statistically significant differences between the success rates for Wilkes stages II, III, IV, and V. CONCLUSION: Arthroscopic lysis and lavage should be performed as a standard operation for internal derangement of the TMJ after failure of conservative treatment in all Wilkes stages.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVE: The aim of this study was to evaluate soft tissue image quality of a mobile cone-beam computed tomography (CBCT) scanner with an integrated flat-panel detector. STUDY DESIGN: Eight fresh human cadavers were used in this study. For evaluation of soft tissue visualization, CBCT data sets and corresponding computed tomography (CT) and magnetic resonance imaging (MRI) data sets were acquired. Evaluation was performed with the help of 10 defined cervical anatomical structures. RESULTS: The statistical analysis of the scoring results of 3 examiners revealed the CBCT images to be of inferior quality regarding the visualization of most of the predefined structures. Visualization without a significant difference was found regarding the demarcation of the vertebral bodies and the pyramidal cartilages, the arteriosclerosis of the carotids (compared with CT), and the laryngeal skeleton (compared with MRI). Regarding arteriosclerosis of the carotids compared with MRI, CBCT proved to be superior. CONCLUSIONS: The integration of a flat-panel detector improves soft tissue visualization using a mobile CBCT scanner.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective. The purpose of this study was to determine the dose profile of the Cranex Tome radiography unit and compare it with that of the Scanora machine.Study design. The radiation dose delivered by the Cranex Tome radiography unit during the cross-sectional mode was determined. Single tooth gaps in regions 3 (16) and 30 (46) were simulated. Dosimetry was carried out with 2 phantoms, a head and neck phantom and a full-body phantom loaded with 142 thermoluminescent dosimeters (TLD) and 280 TLD, respectively; all locations corresponded to radiosensitive organs or tissues. The recorded local mean organ doses were compared with those measured in another study evaluating the Scanora machine.Results. Generally, dose values from the Cranex Tome radiography unit reached only 50% to 60% of the values measured for the Scanora machine. The effective dose was calculated as 0.061 mSv and 0.04 mSv for tooth regions 3 (16) and 30 (46), respectively. Corresponding values for the Scanora machine were 0.117 mSv and 0.084 mSv.Conclusion. Cross-sectional imaging in the molar region of the upper and the lower jaw can be performed with the Cranex Tome unit, which delivers only approximately half of the dose that the Scanora machine delivers.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Dose reduction in digital panoramic radiography was studied. Intentional underexposure was performed with the Orthophos DS while six different human mandibles were radiographed. Exposure settings were 69 kV/15 mA (standard), 64 kV/16 mA, and 60 kV/16 mA. Standardized spherical defects, each either 1 or 1.25 mm in diameter, were simulated in 288 of 432 images, and seven observers decided whether defects were present or not. Areas under the receiver operating characteristics curves were calculated. They showed no significant differences in the detectability of the 1-mm defect at 69, 64, or 60 kV. For the 1.25-mm defect, no difference was found between the 69 and 60 kV images, but a statistically significant different detectability was found for 64 kV images in comparison with both 69 and 60 kV images. A dose reduction of up to 43% was ascertained with a Pedo-RT-Humanoid phantom when panoramic radiography was performed at 60 kV/16 mA. The conclusion is that with the Orthophos DS, it seems possible to reduce the dose rate of x-rays without loss of diagnostic quality in the case of radiolucent changes.