893 resultados para Operating Room
Resumo:
In this work, alpha-Co(OH)(2) is electrodeposited onto carbon nanofoam forming a composite electrode operating in a potential window of 2 V in aqueous medium. Prior to electrodeposition, the carbon nanofoam substrate is subjected to a functionalization process, which leads to an increase of about 40% in its specific capacitance value. Formation of cobalt hydroxide clusters onto the functionalized carbon nanofoam by pulse electrodeposition further enhances the specific capacitance of the electrode. The combination of these factors with an enlarged working potential window, results in a material with specific capacitance close to 300 F g(-1) at current density of 1 A g(-1), considering the total mass loading of the composite. This suggests the potential application of the prepared composites in high energy density electrochemical supercapacitors. (c) 2015 Elsevier B.V. All rights reserved.
Resumo:
According to the hedonic price method, a price of a good is related with the characteristics or the services it provides. Within this framework, the aim of this study it is to examine the effect on room rates of different characteristics of hotels in and around the city of Porto, such as star category, size, room and service quality, hotel facilities and location. It was estimated a hedonic price function, using data for 51 hotels. The results enable to identify the attributes that are important to consumers and hoteliers and to which extent. This information can be used by hotel managers to define a price strategy and helpful in new investment decisions.
Resumo:
No âmbito do desenvolvimento da dissertação do Mestrado de Engenharia Eletrotécnica – Sistemas Elétricos de Energia, surgiu a oportunidade de participar no desenvolvimento de um projeto integrante numa subestação de energia. O presente caso de estudo tem em vista a resolução de condicionantes na conceção desta subestação, tais como cumprir requisitos estéticos projetando todo o tipo de equipamentos dentro de edifícios, a ventilação das salas de transformação assim como insonorização de todo o ruído produzido de forma a cumprir os limites legais e não perturbar a vizinhança. A presente subestação de energia está situada numa zona urbana da cidade de Leiria, localidade de Parceiros, dando origem ao nome Subestação de Energia de Parceiros. Esta subestação pertence ao cliente Energias de Portugal, conhecida como EDP, e visa o melhoramento da distribuição do serviço eléctrico. As tradicionais subestações de energia, com aparência bastante desenquadrada dos meios urbanos, representam um entrave ao nível da aproximação destes centros de produção energética às zonas urbanas, comprometendo a melhoria da rede elétrica. Desta forma, foi implementada a tecnologia Gas-Insolated Switchgear e permite o enquadramento destes centros energéticos em zonas urbanas, constituindo mais um edifício urbano na zona onde se insere. Esta substitui os convencionais barramentos existentes nos Parques Exteriores de Aparelhagem das subestações e apresenta-se com dimensões muito reduzidas quando comparadas com as estruturas instaladas nestes parques. Dado que esta tecnologia é desenvolvida no sentido de permitir a construção destes centros energéticos em zonas urbanas, podem ser alojadas dentro de edifícios produzindo assim vantagens ao nível estético, não perturbando a paisagem. Dado que os principais equipamentos de funcionamento na subestação de Parceiros, nomeadamente o Transformador de Potência, se encontram instalados num edifício completamente fechado, foram construídas duas salas de ventilação, na parte superior deste edifício, cada uma adjacente a uma sala de transformação. O transformador instalado possui elevadas dimensões, pesando 53000 kg e contendo 11000 kg de óleo que em estado normal de funcionamento circula por quase todo o interior da máquina a elevadas temperaturas, provocando um aquecimento elevado no interior do edifício o que condiciona o bom funcionamento do transformador. Para ultrapassar esta condicionante foi realizado um estudo de um sistema de ventilação capaz de avaliar e controlar os valores térmicos existentes e proceder à circulação de ar, que será movimentado ou bloqueado, recorrendo a um sistema autónomo, mantendo a temperatura ideal nas salas de transformação. Este autómato é o cérebro de toda a cadeia lógica que, mediante as leituras efetuadas irá dar ordens de atuação aos diversos equipamentos. Apesar dos TP estarem protegidos dentro do edifício, estes produzem um maior ruído. A necessidade da existência do referido sistema de ventilação das divisões de funcionamento destas máquinas, implica a utilização de aparelhos que, apesar da sua evolução tecnológica os torna cada vez menos ruidosos, mas geram sempre alguma perturbação, o que pode representar um problema no cumprimento do regulamento geral do ruído.
Resumo:
A Work Project, presented as part of the requirements for the Award of a Masters Degree in Finance from the NOVA – School of Business and Economics
Resumo:
Dissertação para obtenção do Grau de Mestre em Engenharia Electrotécnica e de Computadores
Resumo:
A Work Project, presented as part of the requirements for the Award of a Masters Degree in Finance from the NOVA – School of Business and Economics
Resumo:
A Work Project, presented as part of the requirements for the Award of a Masters Degree in Economics from the NOVA – School of Business and Economics
Resumo:
A Work Project, presented as part of the requirements for the Award of a Masters Degree in Management from the NOVA – School of Business and Economics
Resumo:
NSBE - UNL
Resumo:
Research literature and regulators are unconditional in pointing the disclosure of operating cash flow through direct method a section of unique information. Besides the intuitive facet, it is also consistent in forecasting future operating cash flows and a cohesive piece to financial statement puzzle. Bearing this in mind, I produce an analysis on the usefulness and predictive ability on the disclosure of gross cash receipts and payments over the disclosure of reconciliation between net income and accruals for two markets with special features, Portugal and Spain. Results validate the usefulness of direct method format in predicting future operating cash flow. Key
Resumo:
Hypertonic solutions have been studied extensively in the treatment of hypovolemic shock, both in experimental and clinical models. Safety, efficacy, and long-term effects on animals and patients have been evaluated. The present article reviews indications, safety, mortality rates, and outcome in patients with hemorrhagic hypovolemic shock who were treated after admission with a hypertonic/hyperoncotic solution under strict observation in the emergency room.
Resumo:
Since the last decade of the twentieth century, the healthcare industry is paying attention to the environmental impact of their buildings and therefore new regulations, policy goals and Buildings Sustainability Assessment (HBSA) methods are being developed and implemented. At the present, healthcare is one of the most regulated industries and it is also one of the largest consumers of energy per net floor area. To assess the sustainability of healthcare buildings it is necessary to establish a set of benchmarks related with their life-cycle performance. They are both essential to rate the sustainability of a project and to support designers and other stakeholders in the process of designing and operating a sustainable building, by allowing the comparison to be made between a project and the conventional and best market practices. This research is focused on the methodology to set the benchmarks for resources consumption, waste production, operation costs and potential environmental impacts related to the operational phase of healthcare buildings. It aims at contributing to the reduction of the subjectivity found in the definition of the benchmarks used in Building Sustainability Assessment (BSA) methods, and it is applied in the Portuguese context. These benchmarks will be used in the development of a Portuguese HBSA method.
Resumo:
We investigate the long-term performance of cross-delisted firms from U.S. stock markets. Using a sample of foreign firms listed and delisted from U.S. stock exchange markets over 2000-2012, we examine the operating performance and the long-run stock returns performance of firms post-cross-delisting. Our results suggest that cross-delisted firms have less growth opportunities than matched cross-listed firms in the long run. Moreover, firms that cross-delist after the passage of Rule 12h-6 of 2007 exhibit a significant decline in operating performance. In contrast, before the adoption of the Rule 12h-6, cross-delisted firms seem to be affected by the cost of a U.S. listing in the precross -delisting period. In addition, we provide evidence that cross-delisted firms underperform their cross-listed peers; cross-delisted firms experience negative average abnormal returns, especially in the post-delisting period.
Resumo:
Dissertação de mestrado em Bioinformática
Resumo:
OBJECTIVE: Describe suicide attempts assisted in an emergency room (ER) and acute substance consumption or dependence on these individuals. METHODS: Descriptive epidemiologic study was carried out during one year, evaluating suicide attempts assisted at Embu das Artes ER, São Paulo, Brazil. Patients were scheduled to a non structured psychiatric interview. Main outcomes measures were: socio demographic data, suicide attempt method, drugs or alcohol acute use in the six hours prior to attempt, patients with ICD-10 substance dependence diagnosis. The descriptive analyses and chi-square test (p < 0.05) were used to verify associations between the variables studied. RESULTS: sample was formed of 80 patients, mean age of 26.9 years (SD = 8.91), predominantly female (72.5%) and 21.2% adolescents. Most suicide attempts were made through medicine ingestion (62.5%). Approximately 21.2% and 7.5% related to have used alcohol and an illicit drug respectively within 6 hours prior to attempt and 10% were found to be substance dependent. All substance dependents had attempted suicide previously (p-value = 0.4). There was a significant association between suicide attempt through medicine ingestion and psychiatric treatment history (p = 0.02). CONCLUSION: More national studies are necessary to consider the role of alcohol and drug in suicide attempts assisted in ER, especially in chemical dependents whose suicidal behavior is relevant.