981 resultados para Mamas - Implantes articiais


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The short dental implants represent an option of previsible treatment, its main indication lives in the possibility of avoiding techniques surgical invasive. The literature in the display that the geometry of the implants is of vital importance, combined with wide diameters and surface treatment, mainly when the bone quality is unfavorable. The mechanical resistance can be enlarged, increasing the number of implants and being used the spliting among them. A rigorous protocol prosthodontist should be following with intention of to avoid oblique loads and to control habits parafuncionais. We aimed at to discuss, through a wide bibliographical revision the short dental implants, their characteristics and indications, giving emphasis to the aspects biomechanic of the same ones. Material and Method: The bases given: Pubmed, ISI and Dentistry Oral Science from 1990 to 2009, were consulted to identify researches related to the length of the dental implants, with emphasis to the considered short and the biomechanics related to the same ones. They were located 568 articles, being selected 69 that gathered the inclusion criteria. Result: Among these 69 selected, 26 articles agreed the evidence level. Conclusion: Inside of the limits of appraised data, it can be concluded that the short implants represent a good treatment alternative, especially for cases with reduced bone bed. However a rigorous indication protocol and use should be followed for warranty of the success of the treatment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to analyze the biomechanical interactions in bone tissue between short implants and implant-supported crowns with different heights. Two models were made using the programs InVesalius 3.0, Rhinoceros 4.0 and Solidworks 2010. The models were established from a bone block with the short implant (3.75 x 8.5 mm) with geometry Morse taper connection (MT). The height of the crown (cemented) was set at 10.0 mm and 15.00 mm. The models were processed by programs and 10 NEiNastran Femap 10.0. The force applied was 200N (vertical) and 100N (oblique). The results were plotted on maps Voltage Maximum Principal. Statistical analysis was performed using ANOVA. The results showed that the increase in crown height, increased stress concentration in the crown of 15 mm under oblique loading (p <0.001), the oblique loading has significantly expanded the area of stress concentration (p <0.001). Conclusion:the increase of the crown increased the stress concentration, being statistically significant for short implants Morse taper. The mesial and distal region had the highest concentration of stresses under oblique loading. The oblique loading was more harmful when compared with axial loading, being statistically significant.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of implants of greater length may be more favorable for the predictability of dental implants. This statement is relevant, since the cause of failures in dental implants are more related to biomechanical complications. The aim of this study was to evaluate the influence of increase of the length around the entire body of the implant. Six models were created with the presence of only one hexagonal implant (Master Screw connection, Implant Systems, São Paulo, Brazil) of 3.75 mm x 7.0 mm (Model A), 3.75 mm x 8.5 mm (Model B ), 3.75 mm x 10.0 mm (Model C) 3.75 mm x 11.5 mm (Model D) 3.75 mm x 13.0 mm (Model E) 3.75 mm x 15.0 mm (Model F) using the method of photoelasticity. The results were visualized through a qualitative analysis of stresses (number and intensity photoelastic fringes). The model A showed a pattern of less favorable stress distribution, the oblique loading was the most detrimental to the related structures. Conclusion: The increased length allowed for a better distribution of stresses. The oblique loading was more detrimental when compared to axial loading.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The literature has suggested that the association of removable partial dentures with dental implants can improve the quality of life of patients. Thus, the purpose of this study was to present a case report. This case report describes the development of a removable partial denture associated with dental implants bilaterally been monitored for 12 years, and the efficacy of the proposed treatment. The radiographic controls demonstrated no changes on bone tissue. The maxillary arch was rehabilitated with metal-free crowns. The patient was fully satisfied with this technique providing stability, esthetics, and proper function. It was concluded that the technique of using removable partial dentures associated with dental implants is viable and show the advantages of improved function, aesthetics and cost reductions in rehabilitation treatment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to evaluate the biomechanical behavior of different implant connection types, by means of three-dimensional finite element analysis. 3 Three-dimensional models were created with a graphic modeling software: SolidWorks 2006 and Rhinoceros 4.0, and InVesalius (CTI, São Paulo, Brasil), the bone was obtained by computerized tomography of a sagittal section of the molar region. The model was composed by bone block with an implant (4 x 10 mm) (Conexão Sistemas de Prótese, São Paulo), with different implant connections: external hex, internal hex and Morse-taper with the corresponding prosthetic component Ucla or Morse-taper abutment. The Three-dimensional models were transferred to finite element software Femap 10.0 (Siemens PLM Software Inc., CA, USA), to generate a mesh, boundary conditions and loading. An axial (200N) and oblique load (100N) was applied on the occlusal surface of the crowns. Analyses were performed using the finite element software NEiNastran 9.0 (Noran Engineering, Inc., USA) and transferred to the Femap 10.0 to obtain the results; after the results were visualized using von Mises stress maps and Maximum stress principal. The results showed the stress distribution was similar between models, with a little superiority of Morse-taper connection. It was concluded that: the three connection types were biomechanical viable; The Morse-taper connection presented the better internal stress distribution; there was not significant biomechanical differences on the bone.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The obstructive sleep apnea syndrome affects millions of people around the world. The mandibular repositioning devices have been indicated in cases of mild/moderate syndrome; however in edentulous patients its use is deficient since there is no retention. Therefore the objective of this study was to conduct a review on the use of this treatment method combined to osseointegrated implants. A search on the theme: Dental implant and sleep apnea syndromewas performed in the Medline/PubMed, ISI, Cochrane, Dentistry Oral Science, Clinical Trials, Controlled Trials, and Bireme-BvS, databases, and 22 articles were found. After anevaluation 2 studies were selected and the review was complemented with an analysis of randomized controlled trials in the previous seven bases using the key-words: Sleep apnea syndrome, Oral appliance and Randomized controlled trial. The search returned 37 articles, and after they were submitted to inclusion criteria 17 studies were selected. There are a small number of studies presenting the use of dental implants as a mean to assist the stabilization of the mandibular repositioning appliances; those that are available are case reports that focusing on the effectiveness of the technique. Studies examining the effect these appliances in dentate patients indicate improvement in the levels of apnea and snoring. The use of mandibular repositioning appliances in dentate patients is an effective technique in treatment of patients with obstructive sleep apnea syndrome mild/moderate. Randomized controlled trialsare required in order to enable an analysis of the use of mandibular repositioning devices with the aid of dental implants .

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The concept of switching platform is the use of an implant by platform wider than the abutment. Recently, researches have shown that this type of dental implant design tends to offer a higher preservation of crestal bone when compared to the traditional pattern of bone loss. The present study aims to perform a critical review on the switching platform concept establishing possible advantages of the technique. A search was performed on Medline/Pubmed about the topic “dental implant” and “platform switching”, and after applying inclusion criteria 40 studies were selected. The literature on longevity present prospective studies that show less bone loss, studies in biomechanics exhibit better or similar stress distribution around the bone crest, however, is not yet defined the role of the biological width. Thus, studies of longevity, and randomized prospective studies are of a great relevance to be performed in order to confirm the benefits of this technique and to establish a protocol indication. It is possible, based on this literature review, to conclude that longitudinal and randomized studies show that the platform switching implants have longevity and less bone loss. Biomechanically, the technique is possible.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this revision was to explore the concept of Platform Switching in implantology and its acting in the clinical practice. The concept of platform switching will be considered together with a revision of pertinent literature, with the purpose of providing guidelines based on scientific evidences. The following databases were used: Pubmed, Library Cochrane and ISI in the last 17 years. The inclusion approaches were: clinical articles, laboratorials and of revision on the topic, in English language. 41 articles were selected, using the describers "platform switching dental implants", "platform shifting and dental implants", "expanded platform dental implant". In accordance with this revision, implant them platform switching they present a rate of more favorable bony remodeling that you implant them conventional. This fact seems to be resulting of a group of biological factors and mechanics. The concept of platform switching has important relevance in the aesthetic area.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The oral rehabilitation now has a powerful ally: the dental implants. There is no denying the importance of the implant within the context of dental practice. Initially indicated for the rehabilitation of fully edentulous patients, now has gained growing space, with indications for partial edentulism, multiple unit, with high predictability of success in esthetic restorations, combined with the techniques of manipulation of soft tissues, and guided tissue regenerationearly prosthetic loading. But like any dental procedure, whether surgical or medical implantology is also subject to the occurrence of failures and complications. This paper aims to provide a review of the literature for discussion of these complications, their causes, their managements and proservation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Titanium dental implants have been common practice in the dental office, which can increases the number of allergic reactions to this material. Objectives: to alert dental surgeons and specialists of this possible phenomenon through a literature review. Material and methods: an electronic search at PubMed was performed with the keywords “dental implants”, “titanium”, and “allergy” from January 1990 to May 2013. Only articles published in the English language were included. Letters to editor were excluded. Results: from the 22 initially retrieved articles, only 7 were included, being 4 clinical case reports and 3 experimental studies. For clinical cases, the reactions included edema, erythema, exfoliative cheilitis, and eczema. Regarding experimental studies, skin rash and dermatitis were reported. A patch test was not used in two clinical reports. Only one study used histological analysis to attest the lack of allergic reactions. Conclusion: within the limits of the available literature, allergic reactions to titanium dental implants are extremely rare and seem to be related to the female gender. More controlled clinical studies are necessary to elucidate this question.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: The oral rehabilitation with dental implants is a very viable treatment modality for patients. Therefore the discovery of osseointegration, dentistry has reached the trigger with respect to treatment with a high predictability of success. For this various principles, since the surgical protocols, the choice of material and even the technique for the manufacture of implant-supported prosthesis influence a good prognosis for treatment. Objective: Therefore, it is proposed this study a literature review of the fundamentals of osseointegration, explaining the historical and technical parameters of implantology, focusing in what the literature currently is studying with more intensity, the acceleration of osseointegration. Conclusion:well conducted procedures promotes the best aimed success in implantology. Rough surfaces shows great are for implant-bone contact and better mechanical results. The bone quality is fundamental in results foresigh.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

When implants are installed immediately after tooth extraction may occur anchoring primary decreased, delay or failure of osseointegration process. This occurs because of the large interface between the surrounding walls of the socket and the surface of the implant. For reconstruction, replacement or filling of bone defects the solution can be obtained with the use of autogenous, heterogenous or allogeneic bone grafts. However, these grafts suffer certain drawbacks, particularly a high rate of donor site morbidity, limited amounts of available bone, and the additional operative time required for harvest. For these reasons, intensive efforts have been directed toward developing alternative substances for to either augment or substitute. In this paper, we will examine some of the commonly used materials : fibrin and calcium phosphate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Various surface treatments of dental implants have been developed in order to ensure anchorage to bone tissue, optimization of the determinants of electronic structure, crystallinity, composition and properties. Coating techniques have been proposed in order tocreate unionbiochemicalable to accelerate the early stages ofbone tissue, combining the positive properties of titanium and its alloys bioactivity of ceramic materials. This paper discusses protocol for handling the SBF coating of titanium alloys. The apatite phase nucleation occurs by immersing the substrate in synthetic solution simulating blood plasma (Simulated Body Fluid). The protocol allows manipulation of the SBF solution to establish guidelines regarding the usestreamlinedand organized to make practical application.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the last decade mini-screws have gained popularity in orthodontics field and a correct placement of mini-screws is a critical point to the success of the skeletal anchorage. A careful clinical and radiographic diagnostic before insertion mini-screw is an essential requirement to achieve the central point of the radicular septum. The correct application of these pre-surgical procedures should avoid possible iatrogenic damages in periodontal ligament, dental roots, nasomaxillary cavities, or even important vascular tissues. As of today, periapical radiographs is a regular pre surgical procedure during mini-screw insertion technique. Nevertheless, accurate execution of the radiographic parallax technique can offer to us useful and precise radiographic images, to decide the right local insertion of mini-screws in to the septum bone. The purpose of this paper is to describe the ¬application of new positioning circular guides in conjunction with a ¬parallax radiographic protocol before placement of orthodontic mini-screws.