806 resultados para Lente intraocular difractiva
Resumo:
Purpose - To investigate if the accuracy of intraocular pressure (IOP) measurements using rebound tonometry over disposable hydrogel (etafilcon A) contact lenses (CL) is affected by the positive power of the CLs. Methods - The experimental group comprised 26 subjects, (8 male, 18 female). IOP measurements were undertaken on the subjects’ right eyes in random order using a Rebound Tonometer (ICare). The CLs had powers of +2.00 D and +6.00 D. Measurements were taken over each contact lens and also before and after the CLs had been worn. Results - The IOP measure obtained with both CLs was significantly lower compared to the value without CLs (t test; p < 0.001) but no significant difference was found between the two powers of CLs. Conclusions - Rebound tonometry over positive hydrogel CLs leads to a certain degree of IOP underestimation. This result did not change for the two positive lenses used in the experiment, despite their large difference in power and therefore in lens thickness. Optometrists should bear this in mind when measuring IOP with the rebound tonometer over plus power contact lenses.
Resumo:
Purpose: To examine visual outcomes following bilateral implantation of the FineVision trifocal intraocular lens (IOL; PhysIOL, Liège, Belgium). Methods: 26 patients undergoing routine cataract surgery were implanted bilaterally with the FineVision Trifocal IOL and followed up post-operatively for 3 months. The FineVision optic features a combination of 2 diffractive structures, resulting in distance, intermediate (+1.75 D add) and near vision (+3.50 D add) zones. Apodization of the optic surface increases far vision dominance with pupil aperture. Data collected at the 3 month visit included uncorrected and corrected distance (CDVA) and near vision; subjective refraction; defocus curve testing (photopic and mesopic); contrast sensitivity (CSV-1000); halometry glare testing and a questionnaire (NAVQ) to gauge near vision function and patient satisfaction. Results: The cohort comprised 15 males and 11 females, aged 52.5–82.4 years (mean 70.6 ± 8.2 years). Mean post-operative UDVA was 0.22 ± 0.14 logMAR, with a mean spherical equivalent refraction of +0.02 ± 0.35 D. Mean CDVA was 0.13 ± 0.10 logMAR monocularly, and 0.09 ± 0.07 logMAR binocularly. Defocus curve testing showed an extensive range of clear vision in both photopic and mesopic conditions. Patients showed high levels of satisfaction with their near vision (mean ± 0.9 ± 0.6, where 0 = completely satisfied, and 4 = completely unsatisfied) and demonstrated good spectacle independence. Conclusion: The FineVision IOL can be considered in patients seeking spectacle dependence following cataract surgery, and provide good patient satisfaction with uncorrected vision.
Resumo:
PURPOSE: To describe changes in intraocular pressure (IOP) in the 'alternative treatments to Inhibit VEGF in Age-related choroidal Neovascularisation (IVAN)' trial (registered as ISRCTN92166560). DESIGN: Randomised controlled clinical trial with factorial design. PARTICIPANTS: Patients (n=610) with treatment naïve neovascular age-related macular degeneration were enrolled and randomly assigned to receive either ranibizumab or bevacizumab and to two regimens, namely monthly (continuous) or as needed (discontinuous) treatment. METHODS: At monthly visits, IOP was measured preinjection in both eyes, and postinjection in the study eye. OUTCOME MEASURES: The effects of 10 prespecified covariates on preinjection IOP, change in IOP (postinjection minus preinjection) and the difference in preinjection IOP between the two eyes were examined. RESULTS: For every month in trial, there was a statistically significant rise in both the preinjection IOP and the change in IOP postinjection during the time in the trial (estimate 0.02 mm Hg, 95% CI 0.01 to 0.03, p<0.001 and 0.03 mm Hg, 95% CI 0.01 to 0.04, p=0.002, respectively). There was also a small but significant increase during the time in trial in the difference in IOP between the two eyes (estimate 0.01 mm Hg, 95% CI 0.005 to 0.02, p<0.001). There were no differences between bevacizumab and ranibizumab for any of the three outcomes (p=0.93, p=0.22 and p=0.87, respectively). CONCLUSIONS: Anti-vascular endothelial growth factor agents induce increases in IOP of small and uncertain clinical significance.
Resumo:
Mémoire numérisé par la Direction des bibliothèques de l'Université de Montréal.
Resumo:
Purpose: To determine whether the ‘through-focus’ aberrations of a multifocal and accommodative intraocular lens (IOL) implanted patient can be used to provide rapid and reliable measures of their subjective range of clear vision. Methods: Eyes that had been implanted with a concentric (n = 8), segmented (n = 10) or accommodating (n = 6) intraocular lenses (mean age 62.9 ± 8.9 years; range 46-79 years) for over a year underwent simultaneous monocular subjective (electronic logMAR test chart at 4m with letters randomised between presentations) and objective (Aston open-field aberrometer) defocus curve testing for levels of defocus between +1.50 to -5.00DS in -0.50DS steps, in a randomised order. Pupil size and ocular aberration (a combination of the patient’s and the defocus inducing lens aberrations) at each level of blur was measured by the aberrometer. Visual acuity was measured subjectively at each level of defocus to determine the traditional defocus curve. Objective acuity was predicted using image quality metrics. Results: The range of clear focus differed between the three IOL types (F=15.506, P=0.001) as well as between subjective and objective defocus curves (F=6.685, p=0.049). There was no statistically significant difference between subjective and objective defocus curves in the segmented or concentric ring MIOL group (P>0.05). However a difference was found between the two measures and the accommodating IOL group (P<0.001). Mean Delta logMAR (predicted minus measured logMAR) across all target vergences was -0.06 ± 0.19 logMAR. Predicted logMAR defocus curves for the multifocal IOLs did not show a near vision addition peak, unlike the subjective measurement of visual acuity. However, there was a strong positive correlation between measured and predicted logMAR for all three IOLs (Pearson’s correlation: P<0.001). Conclusions: Current subjective procedures are lengthy and do not enable important additional measures such as defocus curves under differently luminance or contrast levels to be assessed, which may limit our understanding of MIOL performance in real-world conditions. In general objective aberrometry measures correlated well with the subjective assessment indicating the relative robustness of this technique in evaluating post-operative success with segmented and concentric ring MIOL.
Resumo:
Mémoire numérisé par la Direction des bibliothèques de l'Université de Montréal.
Resumo:
Purpose. To compare the intraocular pressure (IOP) before and after Laser In Situ Keratomileusis (LASIK), measured by Diaton, Perkins, and noncontact air pulse tonometers. Methods. Fifty-seven patients with a mean age of 34.88 were scheduled for myopia LASIK treatment. Spherical equivalent refraction (SER), corneal curvature (K), and central corneal thickness (CCT) and superior corneal thickness (SCT) were obtained before and after LASIK surgery. IOP values before and after surgery were measured using Diaton, Perkins, and noncontact air pulse tonometers. Results. The IOP values before and after LASIK surgery using Perkins tonometer and air tonometers were statistically significant (). However, no significant differences were found () for IOP values measured with Diaton tonometer. CCT decreases significantly after surgery () but no statistical differences were found in SCT (). Correlations between pre- and postsurgery were found for all tonometers used, with and for the air pulse tonometer, and for Perkins, and and for Diaton. Conclusion. Transpalpebral tonometry may be useful for measuring postsurgery IOP after myopic LASIK ablation because this technique is not influenced by the treatment.
Resumo:
Tesis (Médico Veterinario). -- Universidad de La Salle. Facultad de Ciencias Agropecuarias. Programa de Medicina Veterinaria, 2014
Resumo:
The crystalline lens allows the eye to focus on near and far objects. During the aging process, it loses its ability to focus and often becomes cloudy during cataract formation. At this point, traditional medical therapy replaces the lens with an artificial replacement lens. Although replacement lenses for the crystalline lens have been implanted since 1949 for cataract surgery, none of the FDA-approved lenses mimic the anatomy of the natural lens. Hence, they are not able to focus in a manner similar to the youthful lens. Instead, they function in a manner similar to the aged lens and only provide vision at a single distance or at a very limited range of focal distances. Patients with the newest implants are often obliged to use reading glasses when using near vision, or suffer from optical aberrations, halos, or glare. Therefore, there is a need to provide youthful vision after lens surgery in terms of focusing ability, accurate optical power, and sharp focus without distortion or optical aberrations.
This thesis presents an approach to restoring youthful vision after lens replacement. An intraocular lens (IOL) that can provide accurate visual acuity along with focusing ability is proposed. This IOL relies on the natural anatomy and physiology of the eye, and therefore is actuated in a manner identical to the natural lens. In addition, the lens has the capability for adjustment during or after implantation to provide high-acuity vision throughout life.
The natural anatomy and physiology of the eye is described, along with lens replacement surgery. A lens design is proposed to address the unmet need of lens-replacement patients. Specific care in the design is made for small surgical incisions, high visual acuity, adjustable acuity over years, and the ability to focus similar to the natural lens. Methods to test the IOL using human donor tissue are developed based upon prior experiments on the ex vivo natural lens. These tools are used to demonstrate efficacy of the newly developed accommodating intraocular lens.
To further demonstrate implant feasibility, materials and processes for building the lens are evaluated for biocompatibility, endurance, repeatable manufacture, and stability. The lens biomechanics are determined after developing an artificial anatomy testing setup inspired by the natural anatomy of the human focusing mechanism. Finally, based upon a mechanical and optical knowledge of the lens, several improved lens concepts are proposed and demonstrated for efficacy.
Resumo:
Background In recent years new models of intraocular lenses are appearing on the market to reduce requirements for additional optical correction. The purpose of this study is to assess visual outcomes following bilateral cataract surgery and the implant of a FineVision® trifocal intraocular lens (IOL). Methods Prospective, nonrandomized, observational study. Vision was assessed in 44 eyes of 22 patients (mean age 68.4 ± 5.5 years) before and 3 months after surgery. Aberrations were determined using the Topcon KR-1 W wave-front analyzer. LogMAR visual acuity was measured at distance (corrected distance visual acuity, CDVA 4 m), intermediate (distance corrected intermediate visual acuity, DCIVA 60 cm) and near (distance corrected near visual acuity, DCNVA 40 cm). The Pelli-Robson letter chart and the CSV-1000 test were used to estimate contrast sensitivity (CS). Defocus curve testing was performed in photopic and mesopic conditions. Adverse photic phenomena were assessed using the Halo v1.0 program. Results Mean aberration values for a mesopic pupil diameter were: total HOA RMS: 0.41 ± 0.30 μm, coma: 0.32 ± 0.22 μm and spherical aberration: 0.21 ± 0.20 μm. Binocular logMAR measurements were: CDVA −0.05 ± 0.05, DCIVA 0.15 ± 0.10, and DCNVA 0.06 ± 0.10. Mean Pelli-Robson CS was 1.40 ± 0.14 log units. Mean CSV100 CS for the 4 frequencies examined (A: 3 cycles/degree (cpd), B: 6 cpd, C: 12 cpd, D: 18 cpd) were 1.64 ± 0.14, 1.77 ± 0.18, 1.44 ± 0.24 and 0.98 ± 0.24 log units, respectively. Significant differences were observed in defocus curves for photopic and mesopic conditions (p < 0.0001). A mean disturbance index of 0.28 ± 0.22 was obtained. Conclusions Bilateral FineVision IOL implant achieved a full range of adequate vision, satisfactory contrast sensitivity, and a lack of significant adverse photic phenomena. Trial registration Eudract Clinical Trials Registry Number: 2014-003266-2.
Resumo:
Tesis inédita presentada en la Universidad Europea de Madrid. Facultad de Ciencias de la Salud. Programa de Doctorado en Ciencias de la Visión
Resumo:
O presente trabalho pretende lançar luzes sobre as mulheres especiais estão na criação romanesca machadiana, pois não faltam as mulheres dissimuladas nem as mulheres ambíguas, nem sensuais e muito menos as astuciosas. Elas não têm a fragilidade da mulher romântica, nem a desenvoltura da mulher contemporânea. Geralmente são mulheres maduras, balzaquianas, e se são jovens amadurecem muito cedo sob a lente machadiana.