862 resultados para HIGH-INTENSITY LASER


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The modulation instability (MI) is one of the main factors responsible for the degradation of beam quality in high-power laser systems. The so-called B-integral restriction is commonly used as the criteria for MI control in passive optics devices. For amplifiers the adiabatic model, assuming locally the Bespalov-Talanov expression for MI growth, is commonly used to estimate the destructive impact of the instability. We present here the exact solution of MI development in amplifiers. We determine the parameters which control the effect of MI in amplifiers and calculate the MI growth rate as a function of those parameters. The safety range of operational parameters is presented. The results of the exact calculations are compared with the adiabatic model, and the range of validity of the latest is determined. We demonstrate that for practical situations the adiabatic approximation noticeably overestimates MI. The additional margin of laser system design is quantified. © 2010 Optical Society of America.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Many applications of high-power laser diodes demand tight focusing. This is often not possible due to the multimode nature of semiconductor laser radiation possessing beam propagation parameter M2 values in double-digits. We propose a method of 'interference' superfocusing of high-M2 diode laser beams with a technique developed for the generation of Bessel beams based on the employment of an axicon fabricated on the tip of a 100 μm diameter optical fiber with highprecision direct laser writing. Using axicons with apex angle 140º and rounded tip area as small as 10 μm diameter, we demonstrate 2-4 μm diameter focused laser 'needle' beams with approximately 20 μm propagation length generated from multimode diode laser with beam propagation parameter M2=18 and emission wavelength of 960 nm. This is a few-fold reduction compared to the minimal focal spot size of 11 μm that could be achieved if focused by an 'ideal' lens of unity numerical aperture. The same technique using a 160º axicon allowed us to demonstrate few-μm-wide laser 'needle' beams with nearly 100 μm propagation length with which to demonstrate optical trapping of 5-6 μm rat blood red cells in a water-heparin solution. Our results indicate the good potential of superfocused diode laser beams for applications relating to optical trapping and manipulation of microscopic objects including living biological objects with aspirations towards subsequent novel lab-on-chip configurations.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

As part of the ultrafast charge dynamics initiated by high intensity laser irradiations of solid targets,high amplitude EM pulses propagate away from the interaction point and are transported along anystalks and wires attached to the target. The propagation of these high amplitude pulses along a thinwire connected to a laser irradiated target was diagnosed via the proton radiography technique,measuring a pulse duration of 20 ps and a pulse velocity close to the speed of light. The strongelectric field associated with the EM pulse can be exploited for controlling dynamically the protonbeams produced from a laser-driven source. Chromatic divergence control of broadband laser drivenprotons (upto 75% reduction in divergence of >5 MeV protons) was obtained by winding the supportingwire around the proton beam axis to create a helical coil structure. In addition to providingfocussing and energy selection, the technique has the potential to post-accelerate the transiting protonsby the longitudinal component of the curved electric field lines produced by the helical coil lens.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The V˙O2 slow component (V˙O2sc) that develops during high-intensity aerobic exercise is thought to be strongly associated with locomotor muscle fatigue. We sought to experimentally test this hypothesis by pre-fatiguing the locomotor muscles used during subsequent high-intensity cycling exercise. Over two separate visits, eight healthy male participants were asked to either perform a non-metabolically stressful 100 intermittent drop-jumps protocol (pre-fatigue condition) or rest for 33 min (control condition) according to a random and counterbalanced order. Locomotor muscle fatigue was quantified with 6-s maximal sprints at a fixed pedaling cadence of 90 rev·min−1. Oxygen kinetics and other responses (heart rate, capillary blood lactate concentration and rating of perceived exertion, RPE) were measured during two subsequent bouts of 6 min cycling exercise at 50% of the delta between the lactate threshold and V˙O2max determined during a preliminary incremental exercise test. All tests were performed on the same cycle ergometer. Despite significant locomotor muscle fatigue (P = 0.03), the V˙O2sc was not significantly different between the pre-fatigue (464 ± 301 mL·min−1) and the control (556 ± 223 mL·min−1) condition (P = 0.50). Blood lactate response was not significantly different between conditions (P = 0.48) but RPE was significantly higher following the pre-fatiguing exercise protocol compared with the control condition (P < 0.01) suggesting higher muscle recruitment. These results demonstrate experimentally that locomotor muscle fatigue does not significantly alter the V˙O2 kinetic response to high intensity aerobic exercise, and challenge the hypothesis that the V˙O2sc is strongly associated with locomotor muscle fatigue.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

It has been established that Wingate-based high-intensity training (HIT) consisting of 4 to 6 x 30-s all-out sprints interspersed with 4-min recovery is an effective training paradigm. Despite the increased utilisation of Wingate-based HIT to bring about training adaptations, the majority of previous studies have been conducted over a relatively short timeframe (2 to 6 weeks). However, activity during recovery period, intervention duration or sprint length have been overlooked. In study 1, the dose response of recovery intensity on performance during typical Wingate-based HIT (4 x 30-s cycle all-out sprints separated by 4-min recovery) was examined and active recovery (cycling at 20 to 40% of V̇O2peak) has been shown to improve sprint performance with successive sprints by 6 to 12% compared to passive recovery (remained still), while increasing aerobic contribution to sprint performance by ~15%. In the following study, 5 to 7% greater endurance performance adaptations were achieved with active recovery (40%V̇O2peak) following 2 weeks of Wingate-based HIT. In the final study, shorter sprint protocol (4 to 6 x 15-s sprints interspersed with 2 min of recovery) has been shown to be as effective as typical 30-s Wingate-based HIT in improving cardiorespiratory function and endurance performance over 9 weeks with the improvements in V̇O2peak being completed within 3 weeks, whereas exercise capacity (time to exhaustion) being increased throughout 9 weeks. In conclusion, the studies demonstrate that active recovery at 40% V̇O2peak significantly enhances endurance adaptations to HIT. Further, the duration of the sprint does not seem to be a driving factor in the magnitude of change with 15 sec sprints providing similar adaptations to 30 sec sprints. Taken together, this suggests that the arrangement of recovery mode should be considered to ensure maximal adaptation to HIT, and the practicality of the training would be enhanced via the reduction in sprint duration without diminishing overall training adaptations.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

High intensity leg cycle ergometry is a widely used method of measuring muscular performance during maximal exercise. Until recently, it was deemed to be a predominantly lower body activity; however, there is now evidence to suggest that the upper body could be making a significant contribution to power output, as demonstrated by the intense electrical activity of the forearm musculature. As high intensity cycle ergometry often is used to measure performance in untrained cyclists it is important they are given at least two familiarisation trials to ensure results are both reliable and reproducible. In addition, diurnal variations exist during a single high intensity bout of exercise. It is likely these daily fluctuations are influenced by a number of biochemical and physiological variables. The purpose of this article is to outline factors that contribute to our interpretation of data following high intensity cycle ergometry.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The phenomenon post activation potentiation (PAP) can be defined as an increase in muscle performance following a heavy contraction of a movement that utilizes the same muscle group (i.e. improved 20m sprint following a high intensity squat). However, research has yet to examine if heavy squats elicit PAP on the squat itself. Further, past studies have not yet analyzed if PAP is elicited at a moderate intensity (i.e. 60% one-repetition maximum-1RM).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this study was to quantify the metabolic equivalents (METs) of resistance exercise in obese patients with type 2 diabetes (T2DM) and healthy young subjects and to evaluate whether there were differences between sessions executed at low- versus high-intensity resistance exercise. Twenty obese patients with T2DM (62.9±6.1 years) and 22 young subjects (22.6±1.9 years) performed two training sessions: one at vigorous intensity (80% of 1-repetition maximum (1RM)) and one at moderate intensity (60% of 1RM). Both groups carried out three strength exercises with a 2-day recovery between sessions. Oxygen consumption was continuously measured 15 min before, during and after each training session. Obese T2DM patients showed lower METs values compared with young healthy participants at the baseline phase (F= 2043.86; P<0.01), during training (F=1140.59; P<0.01) and in the post-exercise phase (F=1012.71; P<0.01). No effects were detected in the group x intensity analysis of covariance. In this study, at both light-moderate and vigorous resistance exercise intensities, the METs value that best represented both sessions was 3 METs for the obese elderly T2DM patients and 5 METs for young subjects.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

高强度飞秒激光脉冲的腔外压缩是获得高次谐波阿秒脉冲驱动源的必要手段。实验研究了超强超短飞秒激光脉冲在经过块状介质后的光谱展宽和色散补偿压缩现象。单脉冲能量0.26mJ,脉宽50fs的激光脉冲经透镜在空气中聚焦后再入射到块状材料上,出射脉冲光谱被展宽到接近40nm。由于在块状材料中的自聚焦效应,出射光束质量变好并保持较小的空间啁啾。利用熔融石英棱镜对补偿带有正色散的出射脉冲,最后得到〉0.1mJ,19fs的压缩脉冲。利用SPIDER装置测量了出射脉冲的脉宽和光谱相位。整个系统的能量效率大约为35%,压缩后的