933 resultados para Groundwater flow, Well flow, Analytical solution, Unconfined flow, Imaginary error function
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Pós-graduação em Agronomia (Irrigação e Drenagem) - FCA
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The term model refers to any representation of a real system. The use of models in Hydrogeology can be valuable predictive tools for management of groundwater resources. The numeric models of groundwater flow, object of this study, consist on a set of differential equations that describe the water flow in the porous medium. In this context, numeric simulations were made for a sub-basin located at Cara Preta farm – Santa Rita do Passa Quatro – SP. The aquifer at the local is composed by rocks of Pirambóia Formation, which is part of Guarani Aquifer System. It was developed a conceptual model from previous studies in the area, and from that, simulations were made through the software Visual Modflow®. The conceptual model established previously was considered consistent through the results of simulation.
Resumo:
Pós-graduação em Geociências e Meio Ambiente - IGCE
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Geophysical survey is an important method for investigation of contaminated areas used in the characterization of contrasting physical properties in the presence of pollutants. This work applied the geophysical methods of Electrical Resistivity and Self Potential in waste landfill, located in Caçapava do Sul city, RS. The landfill is located over fractured metamorphic rocks. Eight lines of electrical profiling with 288 measures of self potential were done. In addition, 83 measurements of direction and dip of fractures were taken. The application of spontaneous potential method permitted to detect the direction of groundwater flow. The electrical resistivity measurements allowed the identification of low-intensity anomalies associated with the presence of leachate. There is a relationship between anomalous zones and the directions of fractures.
Resumo:
The numeric simulation is an important tool applied in understanding the dynamics of groundwater flow. In a hydrogeological model the processes responsible for groundwater flow are described by numerical formulations that allow the simplification, representation and understanding of the dynamics of the Aquifer System. In this work, a steady state groundwater flow simulation of Urucuia Aquifer System (UAS) part of the Corrente river basin was conducted, using the finite element method through software FEFLOW, to understand the dynamics of groundwater flow and quantify the hydrologic balance. The aquifer system Urucuia lodges in the São Francisco hydrogeological province and corresponds to a set of interconnected aquifers that occur in rocks from Urucuia group in the Urucuia sub-basin described by Campos e Dardenne (1997). The system is a porous media one, in a shape of a thick table mountain, consisting essentially of sandstones. The Corrente river basin is located in UAS in Western State of Bahia and it's one of the main units to maintaining permanent flow (Q95) and average natural flow of the São Francisco river. The simulation performed in this work obtained the following results for the modelled region: horizontal hydraulic conductivity of 3 x 10-4 m/s and vertical one 6 x 10-5 m/s; maximum recharge of 345 mm and minimum of 85 mm/a. It was concluded that: (1) regional groundwater flow has eastbound; with an exception of the extreme northeast portion, where the flow has opposite direction; (2) there are smaller water side dividers with an approximate direction EW, that guide the flow of water to the drainage that cut the aquifer; and (3) the UAS at Corrente river basin can be understood as a free regional aquifer system, isotropic and homogeneous. Regionally, the small lithological variations present in the Urucuia group can be neglected and do not exhibit significant influences on the dynamics of ground water flow
Resumo:
A contaminated site from a downstream municipal solid waste disposal site in Brazil was investigated by using a 3D resistivity and induced polarization (IP) imaging technique. This investigation purpose was to detect and delineate contamination plume produced by wastes. The area was selected based on previous geophysical investigations, and chemical analyses carried out in the site, indicating the presence of a contamination plume in the area. Resistivity model has successfully imaged waste presence (rho < 20 Omega m), water table depth, and groundwater flow direction. A conductive anomaly (rho < 20 Omega m) outside wastes placement was interpreted as a contamination plume. Chargeability model was also able to imaging waste presence (m > 31 mV/V), water table depth, and groundwater flow direction. A higher chargeability zone (m > 31 mV/V) outside wastes placement and following conductive anomaly was interpreted as a contamination plume. Normalized chargeability (MN = m/rho) confirmed polarizable zone, which could be an effect of a salinity increase (contamination plume), and the clay presence in the environment.
Resumo:
Abstract Introduction We conducted the present study to examine the effects of hypertonic saline solution (7.5%) on cardiovascular function and splanchnic perfusion in experimental sepsis. Methods Anesthetized and mechanically ventilated mongrel dogs received an intravenous infusion of live Escherichia coli over 30 minutes. After 30 minutes, they were randomized to receive lactated Ringer's solution 32 ml/kg (LR; n = 7) over 30 minutes or 7.5% hypertonic saline solution 4 ml/kg (HS; n = 8) over 5 minutes. They were observed without additional interventions for 120 minutes. Cardiac output (CO), mean arterial pressure (MAP), portal and renal blood flow (PBF and RBF, respectively), gastric partial pressure of CO2 (pCO2; gas tonometry), blood gases and lactate levels were assessed. Results E. coli infusion promoted significant reductions in CO, MAP, PBF and RBF (approximately 45%, 12%, 45% and 25%, respectively) accompanied by an increase in lactate levels and systemic and mesenteric oxygen extraction (sO2ER and mO2ER). Widening of venous-arterial (approximately 15 mmHg), portal-arterial (approximately 18 mmHg) and gastric mucosal-arterial (approximately 55 mmHg) pCO2 gradients were also observed. LR and HS infusion transiently improved systemic and regional blood flow. However, HS infusion was associated with a significant and sustained reduction of systemic (18 ± 2.6 versus 38 ± 5.9%) and mesenteric oxygen extraction (18.5 ± 1.9 versus 36.5 ± 5.4%), without worsening other perfusional markers. Conclusion A large volume of LR or a small volume of HS promoted similar transient hemodynamic benefits in this sepsis model. However, a single bolus of HS did promote sustained reduction of systemic and mesenteric oxygen extraction, suggesting that hypertonic saline solution could be used as a salutary intervention during fluid resuscitation in septic patients.
Resumo:
RESUMEN. Se ha llevado a cabo un modelo de flujo de aguas subterráneas en la desembocadura del Barranco de La Aldea (Gran Canaria). El área fue discretizada tridimensionalmente en celdas de 50x50 m considerando 3 capas. La capa superior está constituida por materiales sedimentarios y volcánicos (aluvial, derrubios de ladera y basaltos alterados) y las capas intermedia e inferior por basaltos. Se ha realizado un modelo en régimen estacionario simulando el año hidrológico medio 1991/92 y transitorio para el período de 1991/92-1998/99. Los límites norte, sur y este se han definido como bordes impermeables, la línea de costa se ha definido como nivel constante y la cabecera del barranco se ha simulado mediante un tramo de caudal prefijado representando el aporte de la cuenca alta del barranco. Las entradas en la zona son: recarga por lluvia, retornos de riego, pérdidas en la red de abastecimiento, cabecera del barranco principal y desde la zona de intra-caldera. Las salidas son: bombeos y descarga al mar. El borde inferior se define por el flujo nulo en el contacto entre los basaltos alterados y sin alterar. En el cauce de los barrancos se ha impuesto una condición de dren y las extracciones se han localizado según los datos obtenidos de las captaciones de la zona. Los parámetros resultantes de la calibración del modelo, en particular, la transmisividad, son del mismo orden que los obtenidos en estudios previos modelo. Por otro lado, los niveles calculados y observados presentan un buen ajuste y el balance hídrico resulta consistente. ABSTRACT. A groundwater flow model in La Aldea ravine lower part (Gran Canaria) has been developed. The zone has been tridimensionally discretized as cells of 50 x 50 m considering 3 layers. The superficial layer is formed by sedimentary and volcanic materials (Alluvial, screes and altered basalts) and the intermediate and lower layers are basalts. The model has been developed in stationary state for the average hydrologic year 1991/92 and in transitory state for the period of 1991/92-1998/99. The North, South and East limits have been defined as null flow boundary conditions, the coast line has been defined as constant level and the ravine bed at the east has been defined as a constant flow, representing the contribution from the upper ravine basin. Recharge is a result of rainfall, irrigation returns, supply network leaks and inflow from the intra-caldera zone. Discharge takes place by pumping wells and flows towards the sea. The bottom surface is defined as a null flow condition in the limit between altered and unaltered basalts. A drain condition has been imposed in the ravine and the pumping wells extraction has been located. The simulation results indicate that the transmisivities obtained in previous works present the same order of magnitude than the obtained in the model and the calculated levels are in good agreement with the observed levels measurements.
Resumo:
[ES] El sector Noreste de la Isla de Gran Canaria muestra un sistema de flujo del agua subterránea de cumbre a costa, con desviaciones hacia el fondo del profundo barranco Guiniguada, donde posiblemente estaban los antiguos nacientes, hoy captados por pozos. Existen en la zona 234 captaciones, fundamentalmente pozos de gran diámetro, de los que 140 están en uso, explotándose la Fm. Sálica a cotas bajas y los materiales del Grupo Roque Nublo a cotas elevadas. La salinidad crece de cumbre a costa por mayor efecto del aerosol marino y menor recarga. La recarga media puede variar desde menos de 20 mm/a en zonas bajas hasta más de 500 mm/a en cumbres, lo que puede suponer de 30 a 50 hm3/año que fluyen por la base de las formaciones volcánicas recientes y el techo de las mas antiguas. Los elevados contenidos en nitrato son atribuibles a la gran superficie cultivada. Cabe que la contaminación continúe creciendo pues parte del NO3 puede estar aún avanzado verticalmente por la gruesa zona no saturada.
Resumo:
Beside the traditional paradigm of "centralized" power generation, a new concept of "distributed" generation is emerging, in which the same user becomes pro-sumer. During this transition, the Energy Storage Systems (ESS) can provide multiple services and features, which are necessary for a higher quality of the electrical system and for the optimization of non-programmable Renewable Energy Source (RES) power plants. A ESS prototype was designed, developed and integrated into a renewable energy production system in order to create a smart microgrid and consequently manage in an efficient and intelligent way the energy flow as a function of the power demand. The produced energy can be introduced into the grid, supplied to the load directly or stored in batteries. The microgrid is composed by a 7 kW wind turbine (WT) and a 17 kW photovoltaic (PV) plant are part of. The load is given by electrical utilities of a cheese factory. The ESS is composed by the following two subsystems, a Battery Energy Storage System (BESS) and a Power Control System (PCS). With the aim of sizing the ESS, a Remote Grid Analyzer (RGA) was designed, realized and connected to the wind turbine, photovoltaic plant and the switchboard. Afterwards, different electrochemical storage technologies were studied, and taking into account the load requirements present in the cheese factory, the most suitable solution was identified in the high temperatures salt Na-NiCl2 battery technology. The data acquisition from all electrical utilities provided a detailed load analysis, indicating the optimal storage size equal to a 30 kW battery system. Moreover a container was designed and realized to locate the BESS and PCS, meeting all the requirements and safety conditions. Furthermore, a smart control system was implemented in order to handle the different applications of the ESS, such as peak shaving or load levelling.