991 resultados para Goldoni, Carlo, 1707-1793


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, we present a computer simulation study of the ion binding process at an ionizable surface using a semi-grand canonical Monte Carlo method that models the surface as a discrete distribution of charged and neutral functional groups in equilibrium with explicit ions modelled in the context of the primitive model. The parameters of the simulation model were tuned and checked by comparison with experimental titrations of carboxylated latex particles in the presence of different ionic strengths of monovalent ions. The titration of these particles was analysed by calculating the degree of dissociation of the latex functional groups vs. pH curves at different background salt concentrations. As the charge of the titrated surface changes during the simulation, a procedure to keep the electroneutrality of the system is required. Here, two approaches are used with the choice depending on the ion selected to maintain electroneutrality: counterion or coion procedures. We compare and discuss the difference between the procedures. The simulations also provided a microscopic description of the electrostatic double layer (EDL) structure as a function of pH and ionic strength. The results allow us to quantify the effect of the size of the background salt ions and of the surface functional groups on the degree of dissociation. The non-homogeneous structure of the EDL was revealed by plotting the counterion density profiles around charged and neutral surface functional groups. © 2011 American Institute of Physics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sanktpeterburg 1794

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tutkielman päätavoitteena oli selvittää, miten Monte Carlo –simulointi soveltuu strategisten reaalioptioiden arvonmääritykseen. Tutkielman teoriaosuudessa käytiin läpi reaalioptioteoriaa ja Monte Carlo –simulointimenetelmää toiminta-analyyttisella tutkimusotteella. Tuloksena todettiin, että simulointimenetelmää on reaalioptioiden yhteydessä yleensä käytetty, kun muu menetelmä ei ole ollut mahdollinen. Tutkielman pääpaino on tapaustutkimukseen pohjautuvassa empiriaosuudessa, jossa rakennettiin päätöksentekometodologista tutkimusotetta seuraten simulointimalli, jolla tutkittiin Voest Alpine Stahl Ag:n vaihtoehtoisten hinnoittelustrategioiden taloudellista vaikutusta. Mallin rakentaminen perustui yrityksen tilinpäätösaineistoon. Havaittiin, ettei yritys ole valitsemansa strategian vuoksi juurikaan menettänyt tuottoja, mutta toisaalta pelkkä tilinpäätösaineisto ei riitä kovin luotettavaan tarkasteluun. Vuosikertomusten antaman tiedon pohjalta analysoitiin lisäksi yrityksen toiminnassa havaittuja reaalioptioita. Monte Carlo –simulointimenetelmä sopii reaalioptioiden arvonmääritykseen, mutta kriittisiä tekijöitä ovat mallin rakentaminen ja lähtötietojen oikeellisuus. Numeerisen mallin rinnalla on siksi aiheellista suorittaa myös laadullista reaalioptioanalyysia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The structure of the electric double layer in contact with discrete and continuously charged planar surfaces is studied within the framework of the primitive model through Monte Carlo simulations. Three different discretization models are considered together with the case of uniform distribution. The effect of discreteness is analyzed in terms of charge density profiles. For point surface groups,a complete equivalence with the situation of uniformly distributed charge is found if profiles are exclusively analyzed as a function of the distance to the charged surface. However, some differences are observed moving parallel to the surface. Significant discrepancies with approaches that do not account for discreteness are reported if charge sites of finite size placed on the surface are considered.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In radionuclide metrology, Monte Carlo (MC) simulation is widely used to compute parameters associated with primary measurements or calibration factors. Although MC methods are used to estimate uncertainties, the uncertainty associated with radiation transport in MC calculations is usually difficult to estimate. Counting statistics is the most obvious component of MC uncertainty and has to be checked carefully, particularly when variance reduction is used. However, in most cases fluctuations associated with counting statistics can be reduced using sufficient computing power. Cross-section data have intrinsic uncertainties that induce correlations when apparently independent codes are compared. Their effect on the uncertainty of the estimated parameter is difficult to determine and varies widely from case to case. Finally, the most significant uncertainty component for radionuclide applications is usually that associated with the detector geometry. Recent 2D and 3D x-ray imaging tools may be utilized, but comparison with experimental data as well as adjustments of parameters are usually inevitable.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This chapter presents possible uses and examples of Monte Carlo methods for the evaluation of uncertainties in the field of radionuclide metrology. The method is already well documented in GUM supplement 1, but here we present a more restrictive approach, where the quantities of interest calculated by the Monte Carlo method are estimators of the expectation and standard deviation of the measurand, and the Monte Carlo method is used to propagate the uncertainties of the input parameters through the measurement model. This approach is illustrated by an example of the activity calibration of a 103Pd source by liquid scintillation counting and the calculation of a linear regression on experimental data points. An electronic supplement presents some algorithms which may be used to generate random numbers with various statistical distributions, for the implementation of this Monte Carlo calculation method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: Avaliar a dose absorvida em folículos tireoidianos devido aos elétrons de baixa energia, como os elétrons Auger e os de conversão interna, além das partículas beta, para os radioisótopos de iodo (131I, 132I, 133I, 134I e 135I) usando o método Monte Carlo. MATERIAIS E MÉTODOS: O cálculo da dose foi feito ao nível folicular, simulando elétrons Auger, conversão interna e partículas beta, com o código MCNP4C. Os folículos (colóide e células foliculares) foram modelados como esferas, com diâmetros do colóide variando de 30 a 500 mm. A densidade considerada para os folículos foi a da água (1,0 g.cm-³). RESULTADOS: Considerando partículas de baixa energia, o percentual de contribuição do 131I na dose total absorvida pelo colóide é de aproximadamente 25%, enquanto os isótopos de meia-vida física curta apresentaram contribuição de 75%. Para as células foliculares, esse percentual é ainda maior, chegando a 87% para os iodos de meia-vida curta e 13% para o 131I. CONCLUSÃO: Com base nos resultados obtidos, pode-se mostrar a importância de se considerar partículas de baixa energia na contribuição para a dose total absorvida ao nível folicular (colóide e células foliculares) devido aos radioisótopos de iodo (131I, 132I, 133I, 134I e 135I).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: Determinar, por simulação Monte Carlo, os espectros de feixes de cobaltoterapia em profundidade na água e fatores de correção para doses absorvidas em dosímetros termoluminescentes de fluoreto de lítio. MATERIAIS E MÉTODOS: As simulações dos espectros secundários da fonte clínica de cobalto-60 foram realizadas com o código Monte Carlo PENELOPE, em diversas profundidades na água. Medidas experimentais de dose profunda foram obtidas com dosímetros termoluminescentes e câmara de ionização em condições de referência em radioterapia. Os fatores de correção para os dosímetros termoluminescentes foram obtidos através da razão entre as absorções relativas ao espectro de baixa energia e ao espectro total. RESULTADOS: A análise espectral em profundidade revelou a existência de espectros secundários de baixa energia responsáveis por uma parcela significativa da deposição de dose. Foram observadas discrepâncias de 3,2% nas doses medidas experimentalmente com a câmara de ionização e com os dosímetros termoluminescentes. O uso dos fatores de correção nessas medidas permitiu diminuir a discrepância entre as doses absorvidas para, no máximo, 0,3%. CONCLUSÃO: Os espectros simulados permitem o cálculo de fatores de correção para as leituras de dosímetros termoluminescentes utilizados em medidas de dose profunda, contribuindo para a redução das incertezas associadas ao controle de qualidade de feixes clínicos em radioterapia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nel contributo è pubblicata la prima redazione conosciuta dell'Orazione con cui Giovanni della Casa nel 1549 chiese all'imperatore Carlo V la restituzione di Piacenza ai Farnese, loro sottratta dopo l'uccisione di Pier Luigi nel 1547. L'edizione documenta l'elaborazione d'autore con un apparato evolutivo del testo trasmesso dal manoscritto Vaticano Chigiano O vi 80. This article provides an edition of the first known version of Giovanni della Casa's request to the Emperor Charles V (1549) for the restitution of Piacenza to the Farnese family after Pier Luigi's murder in 1547. This edition documents the Author's working out with an evolutional apparatus of the text transmitted by the manuscript Chigiano O vi 80.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract Objective: Derive filtered tungsten X-ray spectra used in digital mammography systems by means of Monte Carlo simulations. Materials and Methods: Filtered spectra for rhodium filter were obtained for tube potentials between 26 and 32 kV. The half-value layer (HVL) of simulated filtered spectra were compared with those obtained experimentally with a solid state detector Unfors model 8202031-H Xi R/F & MAM Detector Platinum and 8201023-C Xi Base unit Platinum Plus w mAs in a Hologic Selenia Dimensions system using a direct radiography mode. Results: Calculated HVL values showed good agreement as compared with those obtained experimentally. The greatest relative difference between the Monte Carlo calculated HVL values and experimental HVL values was 4%. Conclusion: The results show that the filtered tungsten anode X-ray spectra and the EGSnrc Monte Carlo code can be used for mean glandular dose determination in mammography.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Several authors in the 17th century used the atomic hypothesis to explain observable phenomena. This paper analyzes some ideas about chemical transformation proposed by the English physician Walter Charleton. In Physiologia Epicuro-Gassendo-Charltoniana (London, 1654), Charleton examined philosophical aspects of the atomic theory, and suggested that the best explanation for all natural phenomena would be only in terms of atoms and their motions. Sometimes, however, he had to attribute to the atoms some kind of "internal virtue", to explain more complex properties of the matter. His idea of "element", and the little use of experimentation and quantification, also limited the range of Charleton's theory.