969 resultados para Generation Y


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Programa de doctorado: Ingeniería de Telecomunicación Avanzada

Relevância:

30.00% 30.00%

Publicador:

Resumo:

[ES]Estudio, diseño y desarrollo de un prototipo de videojuego, usando Unity3D y C# como herramientas principales. Dos técnicas de generación procedimental se han usado para generar casi todo el contenido del prototipo: Perlin Noise y BSP.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Máster Universitario en Eficiencia Energética (SIANI)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The latest-generation Amplatzer vascular plug (AVP), the AVP 4, is designed for embolization of smaller vessels without a sheath or guiding catheter. This study evaluated the AVP 4 in peripheral vascular embolization.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to demonstrate that the prevention of early scaffold area shrinkage of the ABSORB BVS (Rev.1.1, Abbott Vascular, Santa Clara, California) was sustained and not simply delayed by a few months.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study is to assess the serial changes in strut apposition and coverage of the bioresorbable vascular scaffolds (BVS) and to relate this with the presence of intraluminal masses at 6 months with optical coherence tomography (OCT).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The herd prevalence of third-generation cephalosporin-resistant Escherichia coli (3GC-R-Ec) was determined for broilers (25.0% [95% confidence interval (CI) 17.6-33.7%]), pigs (3.3% [(95% CI 0.4-11.5%]), and cattle (3.9% [95% CI 0.5-13.5%]), using a sampling strategy that was representative of the livestock population slaughtered in Switzerland between October 2010 and April 2011. The 3GC-R-Ec isolates were characterized by the measurement of the MICs of various antibiotics, microarray analyses, analytical isoelectric focusing, polymerase chain reaction and DNA sequencing for bla genes, pulsed-field gel electrophoresis (PFGE), and multilocus sequence typing. CMY-2 (n = 12), CTX-M-1 (n = 11), SHV-12 (n = 5), TEM-52 (n = 3), CTX-M-15 (n = 2), and CTX-M-3 (n = 1) producers were found. The majority of CMY-2 producers fell into 1 PFGE cluster, which predominantly contained ST61, whereas the CTX-M types were carried by heterogeneous clones of E. coli, as shown by the numerous PFGE profiles and STs that were found. This is the first national Swiss study that focuses on the spread of 3GC-R Enterobacteriaceae among slaughtered animals.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Custom modes at a wavelength of 1064 nm were generated with a deformable mirror. The required surface deformations of the adaptive mirror were calculated with the Collins integral written in a matrix formalism. The appropriate size and shape of the actuators as well as the needed stroke were determined to ensure that the surface of the controllable mirror matches the phase front of the custom modes. A semipassive bimorph adaptive mirror with five concentric ring-shaped actuators and one defocus actuator was manufactured and characterised. The surface deformation was modelled with the response functions of the adaptive mirror in terms of an expansion with Zernike polynomials. In the experiments the Nd:YAG laser crystal was quasi-CW pumped to avoid thermally induced distortions of the phase front. The adaptive mirror allows to switch between a super-Gaussian mode, a doughnut mode, a Hermite-Gaussian fundamental beam, multi-mode operation or no oscillation in real time during laser operation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES: We sought to determine both the procedural performance and safety of percutaneous implantation of the second (21-French [F])- and third (18-F)-generation CoreValve aortic valve prosthesis (CoreValve Inc., Irvine, California). BACKGROUND: Percutaneous aortic valve replacement represents an emerging alternative therapy for high-risk and inoperable patients with severe symptomatic aortic valve stenosis. METHODS: Patients with: 1) symptomatic, severe aortic valve stenosis (area <1 cm2); 2) age > or =80 years with a logistic EuroSCORE > or =20% (21-F group) or age > or =75 years with a logistic EuroSCORE > or =15% (18-F group); or 3) age > or =65 years plus additional prespecified risk factors were included. Introduction of the 18-F device enabled the transition from a multidisciplinary approach involving general anesthesia, surgical cut-down, and cardiopulmonary bypass to a truly percutaneous approach under local anesthesia without hemodynamic support. RESULTS: A total of 86 patients (21-F, n = 50; 18-F, n = 36) with a mean valve area of 0.66 +/- 0.19 cm2 (21-F) and 0.54 +/- 0.15 cm2 (18-F), a mean age of 81.3 +/- 5.2 years (21-F) and 83.4 +/- 6.7 years (18-F), and a mean logistic EuroSCORE of 23.4 +/- 13.5% (21-F) and 19.1 +/- 11.1% (18-F) were recruited. Acute device success was 88%. Successful device implantation resulted in a marked reduction of aortic transvalvular gradients (mean pre 43.7 mm Hg vs. post 9.0 mm Hg, p < 0.001) with aortic regurgitation grade remaining unchanged. Acute procedural success rate was 74% (21-F: 78%; 18-F: 69%). Procedural mortality was 6%. Overall 30-day mortality rate was 12%; the combined rate of death, stroke, and myocardial infarction was 22%. CONCLUSIONS: Treatment of severe aortic valve stenosis in high-risk patients with percutaneous implantation of the CoreValve prosthesis is feasible and associated with a lower mortality rate than predicted by risk algorithms.