999 resultados para Gemstone Team SOLAR CAMPUS


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The thrust towards energy conservation and reduced environmental footprint has fueled intensive research for alternative low cost sources of renewable energy. Organic photovoltaic cells (OPVs), with their low fabrication costs, easy processing and flexibility, represent a possible viable alternative. Perylene diimides (PDIs) are promising electron-acceptor candidates for bulk heterojunction (BHJ) OPVs, as they combine higher absorption and stability with tunable material properties, such as solubility and position of the lowest unoccupied molecular orbital (LUMO) level. A prerequisite for trap free electron transport is for the LUMO to be located at a level deeper than 3.7 eV since electron trapping in organic semiconductors is universal and dominated by a trap level located at 3.6 eV. Although the mostly used fullerene acceptors in polymer:fullerene solar cells feature trap-free electron transport, low optical absorption of fullerene derivatives limits maximum attainable efficiency. In this thesis, we try to get a better understanding of the electronic properties of PDIs, with a focus on charge carrier transport characteristics and the effect of different processing conditions such as annealing temperature and top contact (cathode) material. We report on a commercially available PDI and three PDI derivatives as acceptor materials, and its blends with MEH-PPV (Poly[2-methoxy 5-(2-ethylhexyloxy)-1,4-phenylenevinylene]) and P3HT (Poly(3-hexylthiophene-2,5-diyl)) donor materials in single carrier devices (electron-only and hole-only) and in solar cells. Space-charge limited current measurements and modelling of temperature dependent J-V characteristics confirmed that the electron transport is essentially trap-free in such materials. Different blend ratios of P3HT:PDI-1 (1:1) and (1:3) show increase in the device performance with increasing PDI-1 ratio. Furthermore, thermal annealing of the devices have a significant effect in the solar cells that decreases open-circuit voltage (Voc) and fill factor FF, but increases short-circuit current (Jsc) and overall device performance. Morphological studies show that over-aggregation in traditional donor:PDI blend systems is still a big problem, which hinders charge carrier transport and performance in solar cells.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

RESUMOEste trabalho visa preliminarmente estudar a irradiância total entre 300 e 1100 nm, assim como a razão vermelho-vermelho extremo que chegam ao solo de um trecho de floresta primária e de uma clareira. As áreas selecionadas estão localizadas numa região próxima a cidade de Tucurui, Estado do Pará, Brasil.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Medidas de radiação solar global foram executadas dentro e fora de mata tropical úmida de terra firme durante o dia 07 de novembro de 1986, em Tucuruí, Pará. As intensidades de radiação solar incidentes em 3 sensores instalados aleatoriamente no chão da floresta e um sensor localizado em área aberta (sensor padrão) são avaliadas e intercomparadas. A radiação média que atinge o chão da floreeta foi 4.7% da radiação incidente em área aberta adjacente à floresta. As diferenças entre as medidas dos sensores da mata e o padrão pode ser atribuída à distribuição espacial heterogênea da radiação solar que alcança o chão da floresta.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Taking into account the fact that the sun’s radiation is estimated to be enough to cover 10.000 times the world’s total energy needs (BRAKMANN & ARINGHOFF, 2003), it is difficult to understand how solar photovoltaic systems (PV) are still such a small part of the energy source matrix across the globe. Though there is an ongoing debate as to whether energy consumption leads to economic growth or whether it is the other way around, the two variables appear correlated and it is clear that ensuring the availability of energy to match a country’s growth targets is one of the prime concerns for any government. The topic of centralized vs distributed electricity generation is also approached, especially in what regards the latter fit to developing countries needs, namely the lack of investment capabilities and infrastructure, scattered population, and other factors. Finally, Brazil’s case is reviewed, showing that the current cost of electricity from the grid versus the cost from PV solutions still places an investment of this nature with 9 to 16 years to reach breakeven (from a 25 year panel lifespan), which is too high compared to the required 4 years for most Brazilians. Still, recently passed legislation opened the door, even if unknowingly, to the development of co-owned solar farms, which could reduce the implementation costs by as much as 20% and hence reduce the number of years to breakeven by 3 years.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Um tratamento do regime de radiação no interior de florestas em conexão com a inversão de modelos matemáticos para estimar as características da vegetação (densidade de área foliar, LAI, etc.) é apresentado e discutido neste estudo. Medidas de radiação solar (PAR) realizadas no período de janeiro a abril de 1994 na Reserva Florestal Ducke (Manaus, AM) foram utilizadas para testar o algoritmo resultante e a distribuição vertical de área foliar para a vegetação local foi estabelecida.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study examines the direct and indirect effects of humble leadership on team voice. Although the relationship between leadership styles and voice is widely investigated, humble leadership and team voice, both relatively new constructs, remained out of sight. Drawing upon social interdependence theory, information exchange, team psychological safety, and team-efficacy are proposed to mediate the relationship between humble leadership and team voice. Research is conducted at the team-level analysis and involved 209 team members from 52 teams in 21 companies collected through a snowball sample. Results were provided by the SPSS macro PROCESS using the regression-based approach and bootstrapping techniques. Findings showed that humble leadership is positively related to team voice. Furthermore, findings supported the mediating effect of information exchange. However, no support was given for the mediating effects of team psychological safety and team-efficacy. Theoretical and practical implications of the findings are addressed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Um método de inversão de modelo físico de penetração de radiação solar em meio vegetal para estimar o índice de área foliar(IAF) é apresentado e testado neste trabalho para diferentes tipos de vegetação, como uma alternativa aos experimentos destrutivos, trabalhosos e de difícil implementação em coberturas florestais. Os dados de radiação foram obtidos durante o período seco de 1996 na Estação Experimental da Embrapa, (BR 174 - km 54, 2º 31' S, 60º 01' O), Manaus, Brasil. O método produziu valores de IAF convergentes entre as classes de radiação adotadas, com estimativas mais estáveis para ocasiões em que há predomínio de luz difusa. A aplicação do procedimento de inversão deu origem aos seguintes valores de índice de área foliar e respectivos incrementos anuais: 3,5 (0,35.ano-1) para a vegetação secundária intacta; 2,0 (0,5.ano-1) para o sistema agroflorestal com palmeiras; e 1,6 (0,4.ano-1) para o sistema agroflorestal multiestratificado.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Solar photovoltaic systems are an increasing option for electricity production, since they produce electrical energy from a clean renewable energy resource, and over the years, as a result of the research, their efficiency has been increasing. For the interface between the dc photovoltaic solar array and the ac electrical grid is necessary the use of an inverter (dc-ac converter), which should be optimized to extract the maximum power from the photovoltaic solar array. In this paper is presented a solution based on a current-source inverter (CSI) using continuous control set model predictive control (CCS-MPC). All the power circuits and respective control systems are described in detail along the paper and were tested and validated performing computer simulations. The paper shows the simulation results and are drawn several conclusions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a critical and quantitative analysis of the influence of the Power Quality in grid connected solar photovoltaic microgeneration installations. First are introduced the main regulations and legislation related with the solar photovoltaic microgeneration, in Portugal and Europe. Next are presented Power Quality monitoring results obtained from two residential solar photovoltaic installations located in the north of Portugal, and is explained how the Power Quality events affect the operation of these installations. Afterwards, it is described a methodology to estimate the energy production losses and the impact in the revenue caused by the abnormal operation of the electrical installation. This is done by comparing the amount of energy that was injected into the power grid with the theoretical value of energy that could be injected in normal conditions. The performed analysis shows that Power Quality severally affects the solar photovoltaic installations operation. The losses of revenue in the two monitored installations M1 and M2 are estimated in about 27% and 22%, respectively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents the proposal of a three phase current source shunt active power filter (CS-SAPF) with photovoltaic grid interface. The proposed system combines the compensation of reactive power and harmonics with the injection of energy from a solar photovoltaic array into the electrical power grid. The proposed equipment presents the advantage of giving good use to the current source inverter, even when the solar photovoltaic array is not producing energy. The paper describes the control system of the CS SAPF, the energy injection control strategy, and the current harmonics and power factor compensation strategy. Simulation results to assess the performance of the proposed system are also presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work presents an improved model to solve the non-emergency patients transport (NEPT) service issues given the new rules recently established in Portugal. The model follows the same principle of the Team Orienteering Problem by selecting the patients to be included in the routes attending the maximum reduction in costs when compared with individual transportation. This model establishes the best sets of patients to be transported together. The model was implemented in AMPL and a compact formulation was solved using NEOS Server. A heuristic procedure based on iteratively solving Orienteering Problems is presented, and this heuristic provides good results in terms of accuracy and computation time. Euclidean instances as well as asymmetric real data gathered from Google maps were used, and the model has a promising performance mainly with asymmetric cost matrices.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A ocorrência de radiação solar em meio florestal e a sua relação com a distribuição espacial dos elementos vegetais são investigadas neste trabalho. Técnicas experimentais de amostragem de radiação no interior de coberturas vegetais de grande porte são desenvolvidas e testadas, tendo como base dispositivos de suporte móveis constituídos por reticulados modulares suspensos na parte superior das grandes árvores, que permitem a disposição dos sensores de radiação em diferentes níveis de uma mesma vertical e a replicação das medidas em diferentes verticais no interior da cobertura. As medidas de radiação solar foram realizadas no sítio experimental da Reserva Florestal Ducke (02°56' S; 59°57' W), Manaus — Brasil, no período de 29 de outubro a 11 de dezembro de 1998. A inversão de modelo físico de radiação permitiu o estabelecimento da função de densidade de área foliar para a vegetação do local. Os valores obtidos para o índice de área foliar (IAF) nas três verticais em condições de radiação difusa foram 6,6, 6,3 e 6,2.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A atenuação de radiação solar em meio vegetal e sua relação com a distribuição espacial dos elementos vegetais são estudadas neste trabalho. Técnicas experimentais de amostragem de radiação no interior de coberturas vegetais de grande porte são utilizadas, tendo como base dispositivos de suporte móveis constituídos por reticulados modulares suspensos na parte superior das grandes árvores, que permitem a disposição dos sensores de radiação em diferentes níveis de uma mesma vertical no interior da cobertura. As medidas de radiação solar foram realizadas no sítio experimental da Reserva Florestal Jaru (10°05' S; 61°55' W), Ji-Paraná - Brasil, no período de 30 de outubro a 24 de novembro de 1999. A inversão de modelo físico de radiação permitiu o estabelecimento da função de densidade de área foliar com um valor médio de índice de área foliar IAF de 5,6 para a vegetação do local.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Neste estudo, a distribuição vertical de área foliar em floresta é investigada em conexão com o regime de radiação, usando as medidas de radiação solar realizadas no período de julho a novembro de 2001, na Reserva Biológica do Cuieiras - Manaus ZF2, km 14 e km 34, na Amazônia Central. Técnicas experimentais de amostragem de radiação no interior de coberturas vegetais de grande porte são utilizadas, com dispositivos de suporte móveis constituídos por reticulados modulares, que permitem a disposição dos sensores de radiação em diferentes níveis de uma mesma vertical no interior da cobertura. Inversão de modelos radiativos em coberturas vegetais densas permite as análises sobre a distribuição vertical de área foliar. A variabilidade espacial de área foliar (IAF, função a(z)) é estabelecida para os dois sítios experimentais a partir de medidas de radiação solar, individualizadas em três verticais em cada um desses locais. O índice de área foliar total médio (IAF) da vegetação local para o sítio experimental do km 14 alcançou o valor de 6,4 e para o sítio experimental do km 34 o valor de 6,1. Uma análise comparativa é desenvolvida sobre distribuições verticais de área foliar obtidas em sítios experimentais da Amazônia, usando o mesmo sistema de medidas de radiação solar.