988 resultados para Electrochemical Testing


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recent studies have shown that, besides the well-recognized T3 and T4 hormones, there are other relevant thyroid hormones circulating in the human body. In particular, this is the case for 3-iodothyronamine (T1AM) and thyronamine (T0AM). One of the reasons for the lack of studies showing their precise importance is the absence of analytical methodologies available. Herein, for the first time, T1AM and T0AM are electrochemically characterized. T0AM was sensed by means of a glassy carbon electrode; furthermore, T1AM was sensed both with a graphitic surface (oxidatively) as well as with mercury (reductively). For both compounds, after oxidation, it was possible to observe the reversible redox reaction concerning the benzoquinone/hydroquinone couple, thus increasing the specificity of the electroanalysis. Therefore, this work provides the basis for an ‘at-point-of-use’ electrochemical strip test for T1AM and T0AM.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A candidin, which is a suspension of killed yeast cells, is commonly used for intradermal tests of delayed hypersensitivity, to evaluate the immunological cellular competence of the patient, when the test is applied along with other similar tests. When working with a cellular antigen, the histopathology of positive skin tests reveals a cellular infiltrate which not only presents a characteristic hypersensitivity reaction but also a neutrophilic abscess in the central part. This research presents the results of a comparison between the yeast cell suspension and the polysaccharide antigens, both obtained from the same strains of Candida albicans. The results obtained by skin tests in one hundred individuals were 61.0% with the polysaccharide antigen and 69.0% with the yeast cell suspension antigen. Concordant results concerning the two antigens were observed in 82.0% of the individuals. The discussion section presents an assumption to explain the differences of positivity obtained with the two antigens. We conclude that the polysaccharide antigen can be utilized in the intradermal test of delayed hypersensitivity to Candida albicans.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thesis submitted to the Universidade Nova de Lisboa, Faculdade de Ciências e Tecnologia for the degree of Doctor of Philosophy in Environmental Sciences

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Based on the difficulties experienced in the treatment of chromoblastomycosis, 12 primary human isolates of F. pedrosoi, were tested for their in vitro susceptibility to various antimycotics. We adapted the recommendations of the NCCLS for yeasts and followed the indications for mold testing from other authors in order to determine their MIC’s and the MLC’s. It was found that a significant proportion of the isolates were resistant to 3 of the 4 antimycotics tested, as revealed by high MIC values, as follows: 33% were resistant to amphotericin B (AMB), 58.3% to 5 fluocytosine (5 FC) and 66.7% to fluconazole (FLU). Contrarywise, none of the isolates proved resistant to itraconazole (ITZ). Determination of the MLC’s revealed that a larger proportion of the isolates were not killed by AMB, 5 FC (91.7%), FLU (100%) or even, ITZ (41.7%). These data indicate that it would be desirable to determine the susceptibility of F. pedrosoi before initiating therapy, in order to choose the more effective antifungal and avoid clinical failure

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertation presented to obtain the PhD degree in Biology/Molecular Biology by Universidade Nova de Lisboa, Instituto de Tecnologia Química e Biológica

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A comparison of the Etest and the reference broth macrodilution susceptibility test for fluconazole, ketoconazole, itraconazole and amphotericin B was performed with 59 of Candida species isolated from the oral cavities of AIDS patients. The Etest method was performed according to the manufacturer's instructions, and the reference method was performed according to National Committee for Clinical Laboratory Standards document M27-A guidelines. Our data showed that there was a good correlation between the MICs obtained by the Etest and broth dilution methods. When only the MIC results at ± 2 dilutions for both methods were considered, the agreement rates were 90.4% for itraconazole, ketoconazole and amphotericin B and 84.6% for fluconazole of the C. albicans tested. In contrast, to the reference method, the Etest method classified as susceptible three fluconazole-resistant isolates and one itraconazole-resistant isolate, representing four very major errors. These results indicate that Etest could be considered useful for antifungal sensitivity evaluation of yeasts in clinical laboratories.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new immunosensor is presented for human chorionic gonadotropin (hCG), made by electrodepositing chitosan/gold-nanoparticles over graphene screen-printed electrode (SPE). The antibody was covalently bound to CS via its Fc-terminal. The assembly was controlled by electrochemical Impedance Spectroscopy (EIS) and followed by Fourier Transformed Infrared (FTIR). The hCG-immunosensor displayed linear response against the logarithm-hCG concentration for 0.1–25 ng/mL with limit of detection of 0.016 ng/mL. High selectivity was observed in blank urine and successful detection of hCG was also achieved in spiked samples of real urine from pregnant woman. The immunosensor showed good detection capability, simplicity of fabrication, low-cost, high sensitivity and selectivity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Chemical sensors and biosensors are widely used to detect various kinds of protein target biomolecules. Molecularly Imprinted Polymers (MIPs) have raised great interest in this area, because these act as antibody-like recognition materials, with high affinity to the template molecule. Compared to natural antibodies, these are also of lower cost and higher stability. There are different types of supports used to carry MIP materials, mostly of these made of gold, favourably assembled on a Screen Printed Electrode (SPE) strategy. For this work a new kind of support for the sensing layer was developed: conductive paper. This support was made by modifying first cellulose paper with paraffin wax (to make it waterproof), and casting a carbon-ink on it afterwards, to turn it conductive. The SPAM approach previously reported in1 was employed herein to assemble to MIP sensing material on the conductive paper. The selected charged monomers were (vinylbenzyl) trimethlammonium chloride (positive charge) or vinylbenzoic acid (negative charge), used to generate binding positions with single-type charge (positive or negative). The non-specific binding area of the MIP layer was assembled by chronoamperometry-assisted polymerization (at 1 V, for 60, 120 or 180 seconds) of vinylbenzoate, cross-linked with ethylene glycol vinyl ether. The BSA biomolecules lying within the polymeric matrix were removed by Proteinase K action. All preparation stages of the MIP assembly were followed by FTIR, Raman spectroscopy and, electrochemical analysis. In general, the best results were obtained for longer polymerization times and positively charged binding sites (which was consistent with a negatively-charged protein under physiological pH, as BSA). Linear responses against BSA concentration ranged from 0.005 to 100 mg/mL, in PBS buffer standard solutions. The sensor was further calibrated in standard solutions that were prepared in synthetic or real urine, and the analytical response became more sensitive and stable. Compared to the literature, the detection capability of the developed device is better than most of the reported electrodes. Overall, the simplicity, low cost and good analytical performance of the BSA SPE device, prepared with positively charged binding positions, seems a suitable approach for practical application in clinical context. Further studies with real samples are required, as well as gathering with electronic-supporting devices to allow on-site readings.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Biosensors have opened new horizons in biomedical analysis, by ensuring increased assay speed and flexibility, and allowing point-of-care applications, multi-target analyses, automation and reduced costs of testing. This has been a result of many studies merging nanotechnology with biochemistry over the years, thereby enabling the creation of more suitable environments to biological receptors and their substitution by synthetic analogue materials. Sol-gel chemistry, among other materials, is deeply involved in this process. Sol-gel processing allows the immobilization of organic molecules, biomacromolecules and cells maintaining their properties and activities, permitting their integration into different transduction devices, of electrochemical or optical nature, for single or multiple analyses. Sol-gel also allows to the production of synthetic materials mimicking the activity of natural receptors, while bringing advantages, mostly in terms of cost and stability. Moreover, the biocompatibility of sol-gel materials structures of biological nature allowed the use of these materials in emerging in vivo applications. In this chapter, biosensors for biomedical applications based on sol-gel derived composites are presented, compared and described, along with current emerging applications in vivo, concerning drug delivery or biomaterials. Sol-gel materials are shown as a promising tool for current, emerging and future medical applications. - See more at: http://www.eurekaselect.com/127191/article#sthash.iPqqyhox.dpuf

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel reusable molecularly imprinted polymer (MIP) assembled on a polymeric layer of carboxylated poly(vinyl chloride) (PVCsingle bondCOOH) for myoglobin (Myo) detection was developed. This polymer was casted on the gold working area of a screen printed electrode (Au-SPE), creating a novel disposable device relying on plastic antibodies. Electrochemical impedance spectroscopy (EIS), cyclic voltammetry (CV) and Fourier transform infrared spectroscopy (FTIR) studies confirmed the surface modification. The MIP/Au-SPE devices displayed a linear behaviour in EIS from 0.852 to 4.26 μg mL−1, of positive slope 6.50 ± 1.48 (kΩ mL μg−1). The limit of detection was 2.25 μg mL−1. Square wave voltammetric (SWV) assays were made in parallel and showed linear responses between 1.1 and 2.98 μg mL−1. A current decrease was observed against Myo concentration, producing average slopes of −0.28 ± 0.038 μA mL μg−1. MIP/Au-SPE also showed good results in terms of selectivity. The error% found for each interfering species were 7% for troponin T (TnT), 11% for bovine serum albumin (BSA) and 2% for creatine kinase MB (CKMB), respectively. Overall, the technical modification over the Au-SPE was found a suitable approach for screening Myo in biological fluids.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel surface molecularly-imprinted (MI) material to detect myoglobin (Myo) using gold screen printed electrodes (SPE) was developed. The sensitive detection was carry out by introducing a carboxylic polyvinyl chloride (PVC-COOH) layer on gold SPE surface. Myo was attached to the surface of gold SPE/PVC-COOH and the vacant spaces around it were filled by polymerizing acrylamide and N,N-methylenebisacrylamide (cross-linker). This polymerization was initiated by ammonium persulphate. After removing the template, the obtained material was able to rebind Myo and discriminate it among other interfering species. Various characterization techniques including electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV) confirmed the surface modification. This sensor seemed a promising tool for screening Myo in point-of-care.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação apresentada para a obtenção do Grau de Doutor em Química Sustentável pela Universidade Nova de Lisboa, Faculdade de Ciências e Tecnologia

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIMS: Protocols using sublingual nitrates have been increasingly used to improve diagnostic accuracy of head-up tilt testing (HUT). Nevertheless, exaggerated responses to nitrates have been frequently described, particularly in elderly patients. The aim of this article is to evaluate, in an elderly population with unexplained syncope, whether the impact of sublingual nitroglycerin (NTG) used as a provocative agent is dose-dependent. METHODS AND RESULTS: One hundred and twenty consecutive elderly patients submitted to HUT using NTG after an asymptomatic drug-free phase were studied. Patients were divided into three groups according to the NTG dosage: 500, 375 and 250 microg. The test was considered positive when there was reproduction of symptoms with bradycardia and/or arterial hypotension. A gradual decrease in the blood pressure after NTG was considered an exaggerated response to nitrates. There were no differences in the clinical characteristics of the different subgroups. A positive test was obtained in 50% of the patients in each group. The rate of exaggerated responses was identical in all groups and ranged between 15 and 17%. CONCLUSION: In an elderly population with syncope of unknown origin submitted to HUT, the response to NTG is not dose-dependent, and no difference was found in the rate of exaggerated responses to nitrates with different NTG dosages.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A gold nanoparticle-coated screen-printed carbon electrode was used as the transducer in the development of an electrochemical immunosensor for Ara h 1 (a major peanut allergen) detection in food samples. Gold nanoparticles (average diameter=32 nm) were electrochemically generated on the surface of screen-printed carbon electrodes. Two monoclonal antibodies were used in a sandwich-type immunoassay and the antibody–antigen interaction was electrochemically detected through stripping analysis of enzymatically (using alkaline phosphatase) deposited silver. The total time of the optimized immunoassay was 3 h 50 min. The developed immunosensor allowed the quantification of Ara h 1 between 12.6 and 2000 ng/ml, with a limit of detection of 3.8 ng/ml, and provided precise (RSD <8.7%) and accurate (recovery >96.6%) results. The immunosensor was successfully applied to the analysis of complex food matrices (cookies and chocolate), being able to detect Ara h 1 in samples containing 0.1% of peanut.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An "in-house" RT-PCR method was developed that allows the simultaneous detection of the RNA of the Hepatitis C Virus (HCV) and an artificial RNA employed as an external control. Samples were analyzed in pools of 6-12 donations, each donation included in two pools, one horizontal and one vertical, permitting the immediate identification of a reactive donation, obviating the need for pool dismembering. The whole process took 6-8 hours per day and results were issued in parallel to serology. The method was shown to detect all six HCV genotypes and a sensitivity of 500 IU/mL was achieved (95% hit rate). Until July 2005, 139,678 donations were tested and 315 (0.23%) were found reactive for HCV-RNA. Except for five false-positives, all 310 presented the corresponding antibody as well, so the yield of NAT-only donations was zero, presenting a specificity of 99.83%. Detection of a window period donation, in the population studied, will probably demand testing of a larger number of donations. International experience is showing a rate of 1:200,000 - 1:500,000 of isolated HCV-RNA reactive donations.