789 resultados para ESR DOSIMETRY
Resumo:
Intensity Modulated Radiotherapy (IMRT) is a technique introduced to shape more precisely the dose distributions to the tumour, providing a higher dose escalation in the volume to irradiate and simultaneously decreasing the dose in the organs at risk which consequently reduces the treatment toxicity. This technique is widely used in prostate and head and neck (H&N) tumours. Given the complexity and the use of high doses in this technique it’s necessary to ensure as a safe and secure administration of the treatment, through the use of quality control programmes for IMRT. The purpose of this study was to evaluate statistically the quality control measurements that are made for the IMRT plans in prostate and H&N patients, before the beginning of the treatment, analysing their variations, the percentage of rejected and repeated measurements, the average, standard deviations and the proportion relations.
Resumo:
Pretendeu-se contribuir para um melhor entendimento sobre a discussão patente ao redor da Diretiva EMF 2004/40/CE que limita a exposição dos profissionais aos campos eletromagnéticos (CEM) utilizados em Ressonância Magnética (RM). A aplicabilidade da RM será posta em causa se forem impostos, na prática clínica, os limites expressos na diretiva. Foi explorada a evidência científica, sobre a controvérsia gerada em torno do tema. Analisaram-se guidelines, leis e documentos oficiais e foi aplicado um inquérito a 11 grupos profissionais envolvidos na problemática, distribuídos por vários países. Foi construído o diagrama do campo de forças utilizando a aplicação Policymaker K4 health® afim de se especular sobre influências, forças, poder e estratégias desenvolvidas que possam restringir ou facilitar a aplicação da Diretiva. Verificou-se que 62% dos inquiridos desconhece a Diretiva e o seu conteúdo bem como a posição da Sociedade Europeia de Radiologia (ESR) e 69% dos inquiridos não tem acompanhado os desenvolvimentos do tema. Referem não ter conhecimento da ocorrência de incidentes, para além do efeito míssil e do aquecimento devido a Radiofrequência – Specific Absortion Ratio (SAR). Consideram que o impacto político da Diretiva será neutro, mas o impacto clínico e económico serão negativos. Existe uma subestimação geral desta controvérsia e um não reconhecimento das consequências que a aplicação da Diretiva poderá ter na prática clínica. Admite-se o desenvolvimento de estratégias de pressão e influência para com o poder legislativo da Comissão Europeia e do Conselho, quanto a esta matéria.
Resumo:
Atualmente a Tomografia Computorizada (TC) é o método de imagem que mais contribui para a dose coletiva resultante de exposições médicas. Este estudo pretende determinar os valores de Índice de Dose de TC (CTDI) e produto dose-comprimento (DLP) para os exames de crânio e tórax em adultos num equipamento de TC multidetetores; e efetuar uma análise objetiva e subjetiva da qualidade da imagem. Determinaram-se os valores de CTDI e DLP utilizando uma câmara de ionização e fantomas de crânio e tórax. Efetuou-se ainda uma análise objetiva e subjetiva da qualidade da imagem com o fantoma Catphan® 500 e observadores, respetivamente. Os resultados obtidos foram superiores relativamente às Guidelines europeias no protocolo de crânio (CTDIvol = 80,13 mGy e DLP = 1209,22 mGy.cm) e inferiores no protocolo de tórax (CTDIvol = 8,37 mGy e DLP = 274,71 mGy.cm). Na análise objetiva da qualidade da imagem, à exceção da resolução de baixo contraste no protocolo de crânio, todos os outros critérios analisados estavam em conformidade com a legislação. Na análise subjetiva da qualidade da imagem existiu uma diferença estatisticamente significativa entre as classificações atribuídas pelos observadores às imagens nos parâmetros avaliados (p = 0,000-0,005).
Resumo:
Mestrado em Medicina Nuclear - Ramo de especialização: Radiofarmácia
Resumo:
Mestrado em Radioterapia
Resumo:
Mestrado em Radiações Aplicadas às Tecnologias da Saúde- Ramo de especialização: Terapia com Radiações
Resumo:
X-ray fluoroscopy is essential in both diagnosis and medical intervention, although it may contribute to significant radiation doses to patients that have to be optimised and justified. Therefore, it is crucial to the patient to be exposed to the lowest achievable dose without compromising the image quality. The purpose of this study was to perform an analysis of the quality control measurements, particularly dose rates, contrast and spatial resolution of Portuguese fluoroscopy equipment and also to provide a contribution to the establishment of reference levels for the equipment performance parameters. Measurements carried out between 2007 and 2013 on 143 fluoroscopy equipment distributed by 34 nationwide health units were analysed. The measurements suggest that image quality and dose rates of Portuguese equipment are congruent with other studies, and in general, they are as per the Portuguese law. However, there is still a possibility of improvements intending optimisation at a national level.
Resumo:
The discovery of X-rays was undoubtedly one of the greatest stimulus for improving the efficiency in the provision of healthcare services. The ability to view, non-invasively, inside the human body has greatly facilitated the work of professionals in diagnosis of diseases. The exclusive focus on image quality (IQ), without understanding how they are obtained, affect negatively the efficiency in diagnostic radiology. The equilibrium between the benefits and the risks are often forgotten. It is necessary to adopt optimization strategies to maximize the benefits (image quality) and minimize risk (dose to the patient) in radiological facilities. In radiology, the implementation of optimization strategies involves an understanding of images acquisition process. When a radiographer adopts a certain value of a parameter (tube potential [kVp], tube current-exposure time product [mAs] or additional filtration), it is essential to know its meaning and impact of their variation in dose and image quality. Without this, any optimization strategy will be a failure. Worldwide, data show that use of x-rays has been increasingly frequent. In Cabo Verde, we note an effort by healthcare institutions (e.g. Ministry of Health) in equipping radiological facilities and the recent installation of a telemedicine system requires purchase of new radiological equipment. In addition, the transition from screen-films to digital systems is characterized by a raise in patient exposure. Given that this transition is slower in less developed countries, as is the case of Cabo Verde, the need to adopt optimization strategies becomes increasingly necessary. This study was conducted as an attempt to answer that need. Although this work is about objective evaluation of image quality, and in medical practice the evaluation is usually subjective (visual evaluation of images by radiographer / radiologist), studies reported a correlation between these two types of evaluation (objective and subjective) [5-7] which accredits for conducting such studies. The purpose of this study is to evaluate the effect of exposure parameters (kVp and mAs) when using additional Cooper (Cu) filtration in dose and image quality in a Computed Radiography system.
Resumo:
Purpose: To compare image quality and effective dose when the 10 kVp rule is applied with manual and AEC mode in PA chest X-ray. Methods and Materials: A total of 68 images (with and without lesions) were acquired of an anthropomorphic chest phantom in a Wolverson Arcoma X-ray unit. The images were evaluated against a reference image using image quality criteria and the 2 alternative forced choice (2 AFC) method by five radiographers. The effective dose was calculated using PCXMC software using the exposure parameters and DAP. The exposure index (lgM) was recorded. Results: Exposure time decreases considerably when applying the 10 kVp rule in manual mode (50%-28%) compared to AEC mode (36%-23%). Statistical differences for effective dose between several AEC modes were found (p=0.002). The effective dose is lower when using only the right AEC ionization chamber. Considering image quality, there are no statistical differences (p=0.348) between the different AEC modes for images with no lesions. Using a higher kVp value the lgM values will also increase. The lgM values showed significant statistical differences (p=0.000). The image quality scores did not present statistically significant differences (p=0.043) for the images with lesions when comparing manual with AEC modes. Conclusion: In general, the dose is lower in the manual mode. By using the right AEC ionising chamber the effective dose will be the lowest in comparison to other ionising chambers. The use of the 10 kVp rule did not affect the detectability of the lesions.
Resumo:
Introduction: multimodality environment; requirement for greater understanding of the imaging technologies used, the limitations of these technologies, and how to best interpret the results; dose optimization; introduction of new techniques; current practice and best practice; incidental findings, in low-dose CT images obtained as part of the hybrid imaging process, are an increasing phenomenon with advancing CT technology; resultant ethical and medico-legal dilemmas; understanding limitations of these procedures important when reporting images and recommending follow-up; free-response observer performance study was used to evaluate lesion detection in low-dose CT images obtained during attenuation correction acquisitions for myocardial perfusion imaging, on two hybrid imaging systems.
Resumo:
A TC é um valioso método diagnóstico radiológico. O exame TC pode expor o paciente a uma dose elevada de exposição à radiação, causando risco acrescido. Uma das possíveis soluções para a redução da dose é o uso de técnicas de reconstrução iterativa (IR) em vez das reconstruções tradicionais (FBP). Com base nas suas capacidades de redução de ruído na imagem, a IR pode ter o potencial de reduzir significativamente a dose em pacientes submetidos a TC sem prejudicar a qualidade de imagem. Manter a qualidade de imagem clínica com um nível de qualidade aceitável e expondo o paciente à menor dose possível.
Resumo:
Resumo - O avanço tecnológico e científico no campo da Medicina tem favorecido a aplicação das radiações ionizantes nas áreas da Medicina Nuclear, Radiologia, Radioterapia e noutras especialidades relacionadas com a medicina de intervenção, como a Cardiologia. As Organizações de Saúde, com profissionais com risco de exposição a radiações ionizantes, são responsáveis, legislativamente, por assegurar a sua vigilância. Certificando a observação controlada das doses de exposição, os profissionais são monitorizados com dosímetros individuais e submetidos a vigilância médica. As leituras de dosímetria individual destes profissionais, originam por vezes, nos próprios, desconfianças e incertezas quanto aos valores medidos. Objectivo: avaliar o grau de confiança dos profissionais de saúde, expostos a radiações ionizantes, no sistema de monitorização individual. Metodologia: estudo observacional do tipo analítico- transversal, por questionário. Amostra de 190 Técnicos de Diagnóstico e Terapêutica de Cardiopneumologia, Medicina Nuclear, Radiologia, Radioterapia, expostos a radiações ionizantes, que exercem a sua actividade profissional em hospitais do concelho de Lisboa. Resultados: 51,1% dos Técnicos de Diagnóstico e Terapêutica não confiam nas leituras dos dosímetros, não se determinou uma relação estatisticamente significativa entre essa confiança, o tipo de dosímetro e a empresa que realiza as leituras. A confiança é maior nos que exercem em Organizações de Saúde públicas. 40,2% das Organizações de Saúde apresentam plano de vigilância médica, constatando-se uma falta de conformidade entre os Técnicos de Diagnóstico e Terapêutica, nalguns hospitais, relativamente à existência desse plano no respectivo hospital. A margem de erro associado ao estudo é de 5,09%, com um nível de confiança de 95%. -----------Abstract - The technological and scientific advances in the field of medicine has encouraged the application of ionizing radiation with a considerable positive contribution in the areas of Nuclear Medicine, Radiology, Radiotherapy and other specialties related to medical intervention like Cardiology. The Health Organizations that arise the risk of occupational exposure to ionizing radiation and is their responsibility to ensure monitoring, according the law. To ensure the monitoring of controlled doses of exposure, the exposed works use an individual dosimeter and undergo medical supervision. The individual dosimetry readings of health-care professionals, is sometimes questionable for themselves, arising distrust and uncertainty about the values measured. Objective: evaluate the degree of confidence of health professionals, exposed to radiation, on the system of individual monitoring. Methods: Observational study of cross-type analysis by questionnaire. Sample of 190 of technologists of Cardiopneumology, Nuclear Medicine, Radiology, Radiotherapy, exposed to ionizing radiation, which work in hospitals on the region of Lisbon. Results: 51.1% of technologists does not rely on the readings of their dosimeters, and wasn’t determined a statistically significant relationship between this trust, the type of dosimeter and the company that makes the readings(s) of their(s) dosimeter(s). The confidence in the readings is higher in public Health Organizations. 40.2% of the Health Organizations have medical monitoring plan and there is a disagreement between technologists, in some hospitals, relatively to the existence of this plan in their hospital. It was estimated that the u
Resumo:
Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para obtenção do grau de Mestre em Engenharia Biomédica
Resumo:
Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para obtenção do grau de Mestre em Engenharia Biomédica
Resumo:
Uma nova tecnologia, os EDLC, também denominados por supercondensadores, tem-se tornado numa importante e aliciante área de interesse. Estes regem-se pelos mesmos princípios fundamentais dos condensadores clássicos, no entanto possibilitam receber capacidades superiores, devido a uma maior área de superfície e a um dielétrico menos espesso. Esta particularidade permite obter uma maior densidade energética, comparativamente com os condensadores clássicos e uma maior densidade de potência, comparativamente com as baterias. Consequentemente a utilização de supercondensadores tem aumentado, representando já uma alternativa fiável, segura e amiga do ambiente, em detrimento das baterias comuns. Assim, este projeto tem como principais objetivos, identificar os diferentes tipos de supercondensadores, apresentar as vantagens de cada tipo e explorar a sua resposta, quer no domínio das frequências quer no domínio dos tempos, e por fim modelá-los recorrendo a componentes elétricos clássicos, nomeadamente resistências e condensadores. A modelação foi realizada recorrendo ao MALTAB, através da função de minimização fminunc e foram construídos quatro modelos equivalentes, com o objetivo de modelar a resposta dos vários EDLC analisados. Por escassez de tempo o principal foco de análise recaiu sobre o EDLC de 0,022 F.