782 resultados para Displacement sensor
Resumo:
The determination of characteristic cardiac parameters, such as displacement, stress and strain distribution are essential for an understanding of the mechanics of the heart. The calculation of these parameters has been limited until recently by the use of idealised mathematical representations of biventricular geometries and by applying simple material laws. On the basis of 20 short axis heart slices and in consideration of linear and nonlinear material behaviour we have developed a FE model with about 100,000 degrees of freedom. Marching Cubes and Phong's incremental shading technique were used to visualise the three dimensional geometry. In a quasistatic FE analysis continuous distribution of regional stress and strain corresponding to the endsystolic state were calculated. Substantial regional variation of the Von Mises stress and the total strain energy were observed at all levels of the heart model. The results of both the linear elastic model and the model with a nonlinear material description (Mooney-Rivlin) were compared. While the stress distribution and peak stress values were found to be comparable, the displacement vectors obtained with the nonlinear model were generally higher in comparison with the linear elastic case indicating the need to include nonlinear effects.
Resumo:
OBJECTIVE: To test the accuracy of a new pulse oximeter sensor based on transmittance and reflectance. This sensor makes transillumination of tissue unnecessary and allows measurements on the hand, forearm, foot, and lower limb. DESIGN: Prospective, open, nonrandomized criterion standard study. SETTING: Neonatal intensive care unit, tertiary care center. PATIENTS: Sequential sample of 54 critically ill neonates (gestational age 27 to 42 wks; postnatal age 1 to 28 days) with arterial catheters in place. MEASUREMENTS AND MAIN RESULTS: A total of 99 comparisons between pulse oximetry and arterial saturation were obtained. Comparison of femoral or umbilical arterial blood with transcutaneous measurements on the lower limb (n = 66) demonstrated an excellent correlation (r2 = .96). The mean difference was +1.44% +/- 3.51 (SD) % (range -11% to +8%). Comparison of the transcutaneous values with the radial artery saturation from the corresponding upper limb (n = 33) revealed a correlation coefficient of 0.94 with a mean error of +0.66% +/- 3.34% (range -6% to +7%). The mean difference between noninvasive and invasive measurements was least with the test sensor on the hand, intermediate on the calf and arm, and greatest on the foot. The mean error and its standard deviation were slightly larger for arterial saturation values < 90% than for values > or = 90%. CONCLUSION: Accurate pulse oximetry saturation can be acquired from the hand, forearm, foot, and calf of critically ill newborns using this new sensor.
Resumo:
After a study of the population dynamics of Biomphalaria glabrata snails in several breeding places in the Dominican Republic, the snail Thiara granifera was introduced in some B. glabrata habitats. T. granifera became established in one point in one habitat in the townof Quisqueya, in the east of the country. Around this point of establishment 6 points were selected in order to observe the population dynamics of both species of snails and the chemical and biological characteristics at each point. Four of these points already harbored B. glabrata. One control point was selected also harboring B. glabrata. After 14 months of observations, the results showed that T. granifera was competing with and displacing B. glabrata. This competition does not seem to be competition for food or vital space. Rather, B. glabrata avoids the presence of T. granifera and moves away to new areas, and this is possibly due to a chemical substance(s) secreted by T. granifera or by physical contact with the large number of individuals of T. granifera.
Resumo:
Direct absolute dating of the Penninic Frontal Thrust tectonic motion is achieved using the Ar-40/Ar-39 technique in the Pelvoux Crystalline Massif (Western Alps). The dated phengites were formed syn-kinematically in shear zones. They underline the brittle-ductile stretching lineation, pressure-shadow fibres and slickensides consistent with underthrusting of the European continental slab below the propagating Penninic Thrust. Chlorite-phengite thermobarometry yields 10-15 km and T similar to 280 degrees C, while Ar-40/Ar-39 phengite ages mainly range between 34 and 30 Ma, with one younger age at 27 Ma. This Early Oligocene age range matches a major tectonic rearrangement of the Alpine chain. Preservation of prograde Ar-40/Ar-39 ages is ascribed to passive exhumation of the Pelvoux shear zone network, sandwiched between more external thrusts and the Penninic Front reactivated as an E-dipping detachment fault. Partial resetting in the Low Temperature part of argon spectra below 24 Ma is ascribed to brittle deformation and alteration of phengites.
Resumo:
Activation of the hepatoportal glucose sensors by portal glucose infusion leads to increased glucose clearance and induction of hypoglycemia. Here, we investigated whether glucagon-like peptide-1 (GLP-1) could modulate the activity of these sensors. Mice were therefore infused with saline (S-mice) or glucose (P-mice) through the portal vein at a rate of 25 mg/kg. min. In P-mice, glucose clearance increased to 67.5 +/- 3.7 mg/kg. min as compared with 24.1 +/- 1.5 mg/kg. min in S-mice, and glycemia decreased from 5.0 +/- 0.1 to 3.3 +/- 0.1 mmol/l at the end of the 3-h infusion period. Coinfusion of GLP-1 with glucose into the portal vein at a rate of 5 pmol/kg. min (P-GLP-1 mice) did not increase the glucose clearance rate (57.4 +/- 5.0 ml/kg. min) and hypoglycemia (3.8 +/- 0.1 mmol/l) observed in P-mice. In contrast, coinfusion of glucose and the GLP-1 receptor antagonist exendin-(9-39) into the portal vein at a rate of 0.5 pmol/kg. min (P-Ex mice) reduced glucose clearance to 36.1 +/- 2.6 ml/kg. min and transiently increased glycemia to 9.2 +/- 0.3 mmol/l at 60 min of infusion before it returned to the fasting level (5.6 +/- 0.3 mmol/l) at 3 h. When glucose and exendin-(9-39) were infused through the portal and femoral veins, respectively, glucose clearance increased to 70.0 +/- 4.6 ml/kg. min and glycemia decreased to 3.1 +/- 0.1 mmol/l, indicating that exendin-(9-39) has an effect only when infused into the portal vein. Finally, portal vein infusion of glucose in GLP-1 receptor(-/-) mice failed to increase the glucose clearance rate (26.7 +/- 2.9 ml/kg. min). Glycemia increased to 8.5 +/- 0.5 mmol/l at 60 min and remained elevated until the end of the glucose infusion (8.2 +/- 0.4 mmol/l). Together, our data show that the GLP-1 receptor is part of the hepatoportal glucose sensor and that basal fasting levels of GLP-1 sufficiently activate the receptor to confer maximum glucose competence to the sensor. These data demonstrate an important extrapancreatic effect of GLP-1 in the control of glucose homeostasis.
Resumo:
Recent evidence suggests the existence of a hepatoportal vein glucose sensor, whose activation leads to enhanced glucose use in skeletal muscle, heart, and brown adipose tissue. The mechanism leading to this increase in whole body glucose clearance is not known, but previous data suggest that it is insulin independent. Here, we sought to further determine the portal sensor signaling pathway by selectively evaluating its dependence on muscle GLUT4, insulin receptor, and the evolutionarily conserved sensor of metabolic stress, AMP-activated protein kinase (AMPK). We demonstrate that the increase in muscle glucose use was suppressed in mice lacking the expression of GLUT4 in the organ muscle. In contrast, glucose use was stimulated normally in mice with muscle-specific inactivation of the insulin receptor gene, confirming independence from insulin-signaling pathways. Most importantly, the muscle glucose use in response to activation of the hepatoportal vein glucose sensor was completely dependent on the activity of AMPK, because enhanced hexose disposal was prevented by expression of a dominant negative AMPK in muscle. These data demonstrate that the portal sensor induces glucose use and development of hypoglycemia independently of insulin action, but by a mechanism that requires activation of the AMPK and the presence of GLUT4.
Resumo:
Several species of snails, including Pomacea haustrum, Marisa cornuarietis and Helisoma duryi, have been identified as probable competitors and/or predators of planorbid intermediate hosts of Schistosoma. During the last few years, studies carried out in the Caribbean region have shown reductions and even disappearances of populations of Biomphalaria glabrata and B. straminea in breeding places where the snail Melanoides tuberculata was introduced. Observations made over a period of 10 years in two lakes close to Belo Horizonte, MG, showed that there were marked reductions in autochthonous populations of B. glabrata and B. straminea after the arrival of M. tuberculata, both Biomphalaria species disappearing completely after eight years.
Resumo:
El present treball és un estudi de l'estat de Sensor Web Enablement (SWE) aplicat a l'àmbit marí d'investigació oceanogràfica. Per assolir aquest objectiu s'han avaluat les diferents solucions d'arquitectura de sistemes més adients a la problemàtica indicada i s'ha dissenyat un client de Sensor Observation Service (SOS) per plataforma mòbil Android que permeti consultar la descripció del sensor (SensorML) i conjunts d'observacions mitjançant estàndards oberts de SWE i peticions web (SOAP). Els dissenys anteriorment indicats han permès que quedés palès l'ampli ventall de possibilitats i avantatges que s'obtenen pel fet d'emprar SWE, ja que ens permet integrar fàcilment les dades proporcionades pels sensors i les pròpies descripcions dels sensors en diferents entorns, tal i com és el cas del disseny presentat en Android, a través d'estàndards oberts independents de les múltiples especificacions de cada fabricant, en un entorn, com és l'àmbit de la investigació marina on hi ha una gran heterogeneïtat de sensors i protocols.
Resumo:
This work provides a general description of the multi sensor data fusion concept, along with a new classification of currently used sensor fusion techniques for unmanned underwater vehicles (UUV). Unlike previous proposals that focus the classification on the sensors involved in the fusion, we propose a synthetic approach that is focused on the techniques involved in the fusion and their applications in UUV navigation. We believe that our approach is better oriented towards the development of sensor fusion systems, since a sensor fusion architecture should be first of all focused on its goals and then on the fused sensors
Resumo:
We present a computer vision system that associates omnidirectional vision with structured light with the aim of obtaining depth information for a 360 degrees field of view. The approach proposed in this article combines an omnidirectional camera with a panoramic laser projector. The article shows how the sensor is modelled and its accuracy is proved by means of experimental results. The proposed sensor provides useful information for robot navigation applications, pipe inspection, 3D scene modelling etc
Resumo:
Catadioptric sensors are combinations of mirrors and lenses made in order to obtain a wide field of view. In this paper we propose a new sensor that has omnidirectional viewing ability and it also provides depth information about the nearby surrounding. The sensor is based on a conventional camera coupled with a laser emitter and two hyperbolic mirrors. Mathematical formulation and precise specifications of the intrinsic and extrinsic parameters of the sensor are discussed. Our approach overcomes limitations of the existing omni-directional sensors and eventually leads to reduced costs of production
Resumo:
Introduction : Le monitoring de la tension artérielle à domicile est recommandé par plusieurs guidelines et a été montré être faisable chez la personne âgée. Les manomètres au poignet ont récemment été proposés pour la mesure de la tension artérielle à domicile, mais leur précision n'a pas été au préalable évaluée chez les patients âgés. Méthode : Quarante-huit participants (33 femmes et 15 hommes, moyenne d'âge 81.3±8.0 ans) ont leur tension artérielle mesurée avec un appareil au poignet avec capteur de position et un appareil au bras dans un ordre aléatoire et dans une position assise. Résultats : Les moyennes de mesures de tension artérielle étaient systématiquement plus basses avec l'appareil au poignet par rapport à celui du bras pour la pression systolique (120.1±2.2 vs. 130.5±2.2 mmHg, P < 0.001, moyenneidéviation standard) et pour la pression diastolique (66.011.3 vs. 69.7±1.3 mmHg, P < 0.001). De plus, une différence de lOmmHg ou plus grande entre l'appareil au bras et au poignet était observée dans 54.2 et 18,8% des mesures systoliques et diastoliques respectivement. Conclusion : Comparé à l'appareil au bras, l'appareil au poignet avec capteur de position sous-estimait systématiquement aussi bien la tension artérielle systolique que diastolique. L'ampleur de la différence est cliniquement significative et met en doute l'utilisation de l'appareil au poignet pour monitorer la tension artérielle chez la personne âgée. Cette étude indique le besoin de valider les appareils de mesures de la tension artérielle dans tous les groupes d'âge, y compris les personnes âgées.
Resumo:
El grup de Visió per Computador i Robòtica (VICOROB) disposa de varis robotssubmarins per a la recerca i inspecció subaquàtica. Recentment s’ha adquiritun sensor sonar d’escombrat lateral el qual s’utilitza per realitzar imatgesacústiques del fons marí quan aquest es mou principalment a velocitat constanti mantenint el rumb.Els robots del grup VICOROB estan equipats amb diferents tipus de sensors icàmeres per analitzar el fons marí. Aquest sensors són de gran qualitat ipermeten conèixer de manera bastant satisfactòria l’entorn a les proximitats delrobot. Freqüentment però, aquest sensors estant sotmesos a diferentsrestriccions depenent de la seva naturalesa de funcionament, de tal maneraque es necessària la seva combinació per resoldre determinats problemes endiferents situacions.Amb aquest projecte, es pretén integrar un nou sistema de captura d’imatgessonores del fons marí, en un dels robots. Amb la integració d’aquest nousensor, s’espera obtenir una opció alternativa els sistemes actuals que puguiaportar informació addicional sobre el fons. Aquest sistema podrà ser utilitzatper realitzar tasques per les quals els altres sensors no estant preparats o béper complementar informació d’altres sensor
Resumo:
This paper explores the relationship between violence and displacement during civil war focusing on two different forms of population movements (i.e. incoming and outgoing), and two different forms of violence (i.e. direct and indirect). The paper explores the relationship between displacement and violence at the local level in the context of a civil war fought conventionally using fine-grained data from 1,062 municipalities of the region of Catalonia during the Spanish Civil War (1936-1939). First, the paper suggests that exogenous and endogenous to the war factors combine to generate patterns of resettlement. Second, the evidence indicates that, in acivil war context, refugee flows and violence are interrelated in multiple ways: the arrival of internal refugees in a locality promotes the perpetration of direct violence against civilians; this, in turn, triggers the departure of people from the locality when the other group approaches. Third, indirect violence (i.e. bombings) shows to be the most significant factor accounting for external displacement at the local level, suggesting that bombing can serve as a strong signal for civilians of the type of armed group they are facing. Finally, the Spanish case suggests that the demographic changes provoked by displacement, combined with the lethality of the conflict, are likely to have long-term political consequences.