831 resultados para Direct Analysis Method
Resumo:
In the last decade, Object Based Image Analysis (OBIA) has been accepted as an effective method for processing high spatial resolution multiband images. This image analysis method is an approach that starts with the segmentation of the image. Image segmentation in general is a procedure to partition an image into homogenous groups (segments). In practice, visual interpretation is often used to assess the quality of segmentation and the analysis relies on the experience of an analyst. In an effort to address the issue, in this study, we evaluate several seed selection strategies for an automatic image segmentation methodology based on a seeded region growing-merging approach. In order to evaluate the segmentation quality, segments were subjected to spatial autocorrelation analysis using Moran's I index and intra-segment variance analysis. We apply the algorithm to image segmentation using an aerial multiband image.
Resumo:
Apresenta-se neste trabalho um estudo teórico-experimental sobre a instabilidade de perfis formados a frio submetidos à flexão. A instabilidade distorcional se faz comum na presença de tensões de compressão atuando sobre perfis enrijecidos e fabricados com aços de elevada resistência mecânica. A parte teórica abrange os métodos de cálculo analíticos e numéricos para a análise de instabilidade distorcional de perfis de seção aberta formados a frio. Na parte experimental inclui-se o estudo de perfis formados a frio com seções do tipo U enrijecidos submetidos aos ensaios à flexão. Nestes ensaios variou-se a altura de alma e espessura de chapa procurando-se abranger maior número de condições geométricas para análise da estabilidade distorcional. Inclui-se também a análise de instabilidade numérica dos perfis do programa experimental através do método de resistência direta via método das faixas finitas. Com base nos resultados experimentais, numéricos e na análise teórica do problema, verificou-se o procedimento adotado pela NBR14762/2001 e efetuou-se comparação entre curvas de resistência propostas para o dimensionamento de perfis formados a frio à flexão. Foi verificado que o fenômeno de instabilidade distorcional pode ser o estado limite último crítico para o dimensionamento dos perfis formados a frio.
Resumo:
Estima-se que 52% da população mundial faz uso de álcool, sendo a droga mais consumida no mundo. Ao usuário, o álcool torna-se prejudicial devido às consequências nos níveis biológicos, sociais e funcionais. Assim, a redução do uso abusivo da substância é um dos objetivos da Organização Mundial de Saúde (OMS) e uma das prioridades na agenda de saúde pública mundial. No Brasil, a Política do Ministério da Saúde para a Atenção Integral aos Usuários de Álcool e Outras Drogas teve como objetivo a criação de uma rede de atenção integral a eles - a RAPS (Rede de Atenção Psicossocial). A RAPS é considerada um grande avanço da Reforma Psiquiátrica, já que integra os diversos pontos de atenção disponíveis no Sistema Único de Saúde (SUS). Um dos pontos da RAPS é a Atenção Básica (AB), que através da atuação das equipes da Estratégia Saúde da Família (ESF) tem a possibilidade de monitoração, prevenção do uso e colaboração na reinserção social dos usuários de álcool e outras drogas devido à proximidade e criação de vínculo entre o serviço e usuário. Para que o vínculo seja estabelecido o Agente Comunitário de Saúde (ACS) é a peça fundamental, visto que conhece a comunidade e reconhece suas necessidades, além de ser a figura que medeia as relações entre a equipe de saúde e os usuários. Assim sendo, o objetivo deste estudo foi descrever e analisar o discurso de ACS sobre o uso de álcool e a assistência prestada na AB. Trata-se de um estudo qualitativo de teor descritivo, cuja pesquisa ocorreu em cinco municípios da região central do Estado de Santa Catarina. Foram realizadas entrevistas semiestruturadas, analisadas através do método da Análise de Conteúdo. A análise das entrevistas resultou na formulação de duas categorias e quatro subcategorias empíricas. Os resultados evidenciaram que os ACS percebem o consumo de álcool como inerente a população em virtude da cultura caracterizada pelo consumo habitual e festivo da droga. Eles percebem que o uso do álcool torna-se um problema quanto à definição social atribuída pela comunidade, ressaltando as consequências para a família e outras perdas vivenciadas pelos usuários com base nas repercussões sociais. Quanto à assistência prestada por eles aos usuários de álcool, os resultados indicaram uma prática desprovida de instrumentos ou habilidades para a abordagem adequada do uso, evidenciando uma prática infundada pelos ACS. A prática está pautada também nas crenças em relação aos usuários de álcool, que estão muito ligadas aos estigmas relacionados a estes usuários em geral e não em evidências científicas. Conclui-se que a partir do conhecimento das percepções e práticas deste profissional, é possível direcionar ações que potencialize a prática dos ACS, já que são profissionais com grandes possibilidades de atuação diante da prevenção e tratamento do abuso de álcool e reabilitação social do usuário
Resumo:
Uma grande diversidade de macrofibras poliméricas para reforço de concreto se encontram disponibilizadas hoje em dia. Por natureza estas fibras apresentam grande diversidade de características e propriedades. Estas variações afetam sua atuação como reforço no concreto. No entanto, não há normas brasileiras sobre o assunto e as metodologias de caracterização de normas estrangeiras apresentam divergências. Algumas normas definem que a caracterização do comportamento mecânico deva ser feita nos fios originais e outras que se devam utilizar métodos definidos para caracterização de materiais metálicos. A norma EN14889-2:2006 apresenta maior abrangência, mas deixa dúvidas quanto à adequação dos critérios de caracterização geométrica das fibras e não define um método de ensaio específico para sua caracterização mecânica. Assim, há a necessidade de estabelecimento de uma metodologia que permita a realização de um programa de controle de qualidade da fibra nas condições de emprego. Esta metodologia também proporcionaria uma forma de caracterização do material para estudos experimentais, o que permitiria maior fundamentação científica desses trabalhos que, frequentemente, fundamentam-se apenas em dados dos fabricantes. Assim, foi desenvolvido um estudo experimental focando a caracterização de duas macrofibras poliméricas disponíveis no mercado brasileiro. Focou-se o estudo na determinação dos parâmetros geométricos e na caracterização mecânica através da determinação da resistência à tração e avaliação do módulo de elasticidade. Na caracterização geométrica foi adotada como referência a norma europeia EN14889-2:2006. As medições do comprimento se efetuaram por dois métodos: o método do paquímetro e o método de análise de imagens digitais, empregando um software para processamento das imagens. Para a medição do diâmetro, além das metodologias mencionadas, foi usado o método da densidade. Conclui-se que o método do paquímetro, com o cuidado de esticar previamente as macrofibras, e o método das imagens digitais podem ser igualmente utilizados para medir o comprimento. Já parar determinar o diâmetro, recomenda-se o método da densidade. Quanto à caracterização mecânica, foi desenvolvida uma metodologia própria a partir de informações obtidas de outros ensaios. Assim, efetuaram-se ensaios de tração direta nas macrofibras coladas em molduras de tecido têxtil. Complementarmente, foi avaliado também o efeito do contato abrasivo das macrofibras com os agregados durante a mistura em betoneira no comportamento mecânico do material. Também se avaliou o efeito do método de determinação da área da seção transversal nos resultados medidos no ensaio de tração da fibra. Conclui-se que o método proposto para o ensaio de tração direta da fibra é viável, especialmente para a determinação da resistência à tração. O valor do módulo de elasticidade, por sua vez, acaba sendo subestimado. A determinação da área da seção da fibra através do método da densidade forneceu também os melhores resultados. Além disso, comprovou-se que o atrito das fibras com o agregado durante a mistura compromete o comportamento mecânico, reduzindo tanto a resistência quanto o módulo de elasticidade. Assim, pode-se afirmar que a metodologia proposta para o controle geométrico e mecânico das macrofibras poliméricas é adequada para a caracterização do material.
Resumo:
Background: The Clinical Learning Environment, Supervision and Nurse Teacher scale is a reliable and valid instrument to evaluate the quality of the clinical learning process in international nursing education contexts. Objectives: This paper reports the development and psychometric testing of the Spanish version of the Clinical Learning Environment, Supervision and Nurse Teacher scale. Design: Cross-sectional validation study of the scale. Setting: 10 public and private hospitals in the Alicante area, and the Faculty of Health Sciences (University of Alicante, Spain). Participants: 370 student nurses on clinical placement (January 2011–March 2012). Methods: The Clinical Learning Environment, Supervision and Nurse Teacher scale was translated using the modified direct translation method. Statistical analyses were performed using PASW Statistics 18 and AMOS 18.0.0 software. A multivariate analysis was conducted in order to assess construct validity. Cronbach’s alpha coefficient was used to evaluate instrument reliability. Results: An exploratory factorial analysis identified the five dimensions from the original version, and explained 66.4% of the variance. Confirmatory factor analysis supported the factor structure of the Spanish version of the instrument. Cronbach’s alpha coefficient for the scale was .95, ranging from .80 to .97 for the subscales. Conclusion: This version of the Clinical Learning Environment, Supervision and Nurse Teacher scale instrument showed acceptable psychometric properties for use as an assessment scale in Spanish-speaking countries.
Resumo:
In vitro evolution imitates the natural evolution of genes and has been very successfully applied to the modification of coding sequences, but it has not yet been applied to promoter sequences. We propose an alternative method for functional promoter analysis by applying an in vitro evolution scheme consisting of rounds of error-prone PCR, followed by DNA shuffling and selection of mutant promoter activities. We modified the activity in embryogenic sugarcane cells of the promoter region of the Goldfinger isolate of banana streak virus and obtained mutant promoter sequences that showed an average mutation rate of 2.5% after applying one round of error-prone PCR and DNA shuffling. Selection and sequencing of promoter sequences with decreased or unaltered activity allowed us to rapidly map the position of one cis-acting element that influenced promoter activity in embryogenic sugarcane cells and to discover neutral mutations that did not affect promoter Junction. The selective-shotgun approach of this promoter analysis method immediately after the promoter boundaries have been defined by 5' deletion analysis dramatically reduces the labor associated with traditional linker-scanning deletion analysis to reveal the position of functional promoter domains. Furthermore, this method allows the entire promoter to be investigated at once, rather than selected domains or nucleotides, increasing the, prospect of identifying interacting promoter regions.
Resumo:
In this work, we propose an improvement of the classical Derjaguin-Broekhoff-de Boer (DBdB) theory for capillary condensation/evaporation in mesoporous systems. The primary idea of this improvement is to employ the Gibbs-Tolman-Koenig-Buff equation to predict the surface tension changes in mesopores. In addition, the statistical film thickness (so-called t-curve) evaluated accurately on the basis of the adsorption isotherms measured for the MCM-41 materials is used instead of the originally proposed t-curve (to take into account the excess of the chemical potential due to the surface forces). It is shown that the aforementioned modifications of the original DBdB theory have significant implications for the pore size analysis of mesoporous solids. To verify our improvement of the DBdB pore size analysis method (IDBdB), a series of the calcined MCM-41 samples, which are well-defined materials with hexagonally ordered cylindrical mesopores, were used for the evaluation of the pore size distributions. The correlation of the IDBdB method with the empirically calibrated Kruk-Jaroniec-Sayari (KJS) relationship is very good in the range of small mesopores. So, a major advantage of the IDBdB method is its applicability for small mesopores as well as for the mesopore range beyond that established by the KJS calibration, i.e., for mesopore radii greater than similar to4.5 nm. The comparison of the IDBdB results with experimental data reported by Kruk and Jaroniec for capillary condensation/evaporation as well as with the results from nonlocal density functional theory developed by Neimark et al. clearly justifies our approach. Note that the proposed improvement of the classical DBdB method preserves its original simplicity and simultaneously ensures a significant improvement of the pore size analysis, which is confirmed by the independent estimation of the mean pore size by the powder X-ray diffraction method.
Resumo:
Since 1996 direct femtosecond inscription in transparent dielectrics has become the subject of intensive research. This enabling technology significantly expands the technological boundaries for direct fabrication of 3D structures in a wide variety of materials. It allows modification of non-photosensitive materials, which opens the door to numerous practical applications. In this work we explored the direct femtosecond inscription of waveguides and demonstrated at least one order of magnitude enhancement in the most critical parameter - the induced contrast of the refractive index in a standard borosilicate optical glass. A record high induced refractive contrast of 2.5×10-2 is demonstrated. The waveguides fabricated possess one of the lowest losses, approaching level of Fresnel reflection losses at the glassair interface. High refractive index contrast allows the fabrication of curvilinear waveguides with low bend losses. We also demonstrated the optimisation of the inscription regimes in BK7 glass over a broad range of experimental parameters and observed a counter-intuitive increase of the induced refractive index contrast with increasing translation speed of a sample. Examples of inscription in a number of transparent dielectrics hosts using high repetition rate fs laser system (both glasses and crystals) are also presented. Sub-wavelength scale periodic inscription inside any material often demands supercritical propagation regimes, when pulse peak power is more than the critical power for selffocusing, sometimes several times higher than the critical power. For a sub-critical regime, when the pulse peak power is less than the critical power for self-focusing, we derive analytic expressions for Gaussian beam focusing in the presence of Kerr non-linearity as well as for a number of other beam shapes commonly used in experiments, including astigmatic and ring-shaped ones. In the part devoted to the fabrication of periodic structures, we report on recent development of our point-by-point method, demonstrating the shortest periodic perturbation created in the bulk of a pure fused silica sample, by using third harmonics (? =267 nm) of fundamental laser frequency (? =800 nm) and 1 kHz femtosecond laser system. To overcome the fundamental limitations of the point-by-point method we suggested and experimentally demonstrated the micro-holographic inscription method, which is based on using the combination of a diffractive optical element and standard micro-objectives. Sub-500 nm periodic structures with a much higher aspect ratio were demonstrated. From the applications point of view, we demonstrate examples of photonics devices by direct femtosecond fabrication method, including various vectorial bend-sensors fabricated in standard optical fibres, as well as a highly birefringent long-period gratings by direct modulation method. To address the intrinsic limitations of femtosecond inscription at very shallow depths we suggested the hybrid mask-less lithography method. The method is based on precision ablation of a thin metal layer deposited on the surface of the sample to create a mask. After that an ion-exchange process in the melt of Ag-containing salts allows quick and low-cost fabrication of shallow waveguides and other components of integrated optics. This approach covers the gap in direct fs inscription of shallow waveguide. Perspectives and future developments of direct femtosecond micro-fabrication are also discussed.
Resumo:
This article is aimed primarily at eye care practitioners who are undertaking advanced clinical research, and who wish to apply analysis of variance (ANOVA) to their data. ANOVA is a data analysis method of great utility and flexibility. This article describes why and how ANOVA was developed, the basic logic which underlies the method and the assumptions that the method makes for it to be validly applied to data from clinical experiments in optometry. The application of the method to the analysis of a simple data set is then described. In addition, the methods available for making planned comparisons between treatment means and for making post hoc tests are evaluated. The problem of determining the number of replicates or patients required in a given experimental situation is also discussed. Copyright (C) 2000 The College of Optometrists.
Resumo:
Recently, we introduced a new 'GLM-beamformer' technique for MEG analysis that enables accurate localisation of both phase-locked and non-phase-locked neuromagnetic effects, and their representation as statistical parametric maps (SPMs). This provides a useful framework for comparison of the full range of MEG responses with fMRI BOLD results. This paper reports a 'proof of principle' study using a simple visual paradigm (static checkerboard). The five subjects each underwent both MEG and fMRI paradigms. We demonstrate, for the first time, the presence of a sustained (DC) field in the visual cortex, and its co-localisation with the visual BOLD response. The GLM-beamformer analysis method is also used to investigate the main non-phase-locked oscillatory effects: an event-related desynchronisation (ERD) in the alpha band (8-13 Hz) and an event-related synchronisation (ERS) in the gamma band (55-70 Hz). We show, using SPMs and virtual electrode traces, the spatio-temporal covariance of these effects with the visual BOLD response. Comparisons between MEG and fMRI data sets generally focus on the relationship between the BOLD response and the transient evoked response. Here, we show that the stationary field and changes in oscillatory power are also important contributors to the BOLD response, and should be included in future studies on the relationship between neuronal activation and the haemodynamic response. © 2005 Elsevier Inc. All rights reserved.
Resumo:
Purpose: To determine the most appropriate analysis technique for the differentiation of multifocal intraocular lens (MIOL) designs using defocus curve assessment of visual capability.Methods:Four groups of fifteen subjects were implanted bilaterally with either monofocal intraocular lenses, refractive MIOLs, diffractive MIOLs, or a combination of refractive and diffractive MIOLs. Defocus curves between -5.0D and +1.5D were evaluated using an absolute and relative depth-of-focus method, the direct comparison method and a new 'Area-of-focus' metric. The results were correlated with a subjective perception of near and intermediate vision. Results:Neither depth-of-focus method of analysis were sensitive enough to differentiate between MIOL groups (p>0.05). The direct comparison method indicated that the refractive MIOL group performed better at +1.00, -1.00 and -1.50 D and worse at -3.00, -3.50, -4.00 and -5.00D compared to the diffractive MIOL group (p
Resumo:
The concept of a task is fundamental to the discipline of ergonomics. Approaches to the analysis of tasks began in the early 1900's. These approaches have evolved and developed to the present day, when there is a vast array of methods available. Some of these methods are specific to particular contexts or applications, others more general. However, whilst many of these analyses allow tasks to be examined in detail, they do not act as tools to aid the design process or the designer. The present thesis examines the use of task analysis in a process control context, and in particular the use of task analysis to specify operator information and display requirements in such systems. The first part of the thesis examines the theoretical aspect of task analysis and presents a review of the methods, issues and concepts relating to task analysis. A review of over 80 methods of task analysis was carried out to form a basis for the development of a task analysis method to specify operator information requirements in industrial process control contexts. Of the methods reviewed Hierarchical Task Analysis was selected to provide such a basis and developed to meet the criteria outlined for such a method of task analysis. The second section outlines the practical application and evolution of the developed task analysis method. Four case studies were used to examine the method in an empirical context. The case studies represent a range of plant contexts and types, both complex and more simple, batch and continuous and high risk and low risk processes. The theoretical and empirical issues are drawn together and a method developed to provide a task analysis technique to specify operator information requirements and to provide the first stages of a tool to aid the design of VDU displays for process control.
Resumo:
The thesis presents new methodology and algorithms that can be used to analyse and measure the hand tremor and fatigue of surgeons while performing surgery. This will assist them in deriving useful information about their fatigue levels, and make them aware of the changes in their tool point accuracies. This thesis proposes that muscular changes of surgeons, which occur through a day of operating, can be monitored using Electromyography (EMG) signals. The multi-channel EMG signals are measured at different muscles in the upper arm of surgeons. The dependence of EMG signals has been examined to test the hypothesis that EMG signals are coupled with and dependent on each other. The results demonstrated that EMG signals collected from different channels while mimicking an operating posture are independent. Consequently, single channel fatigue analysis has been performed. In measuring hand tremor, a new method for determining the maximum tremor amplitude using Principal Component Analysis (PCA) and a new technique to detrend acceleration signals using Empirical Mode Decomposition algorithm were introduced. This tremor determination method is more representative for surgeons and it is suggested as an alternative fatigue measure. This was combined with the complexity analysis method, and applied to surgically captured data to determine if operating has an effect on a surgeon’s fatigue and tremor levels. It was found that surgical tremor and fatigue are developed throughout a day of operating and that this could be determined based solely on their initial values. Finally, several Nonlinear AutoRegressive with eXogenous inputs (NARX) neural networks were evaluated. The results suggest that it is possible to monitor surgeon tremor variations during surgery from their EMG fatigue measurements.
Resumo:
In this thesis, standard algorithms are used to carry out the optimisation of cold-formed steel purlins such as zed, channel and sigma sections, which are assumed to be simply supported and subjected to a gravity load. For zed, channel and sigma section, the local buckling, distortional buckling and lateral-torsional buckling are considered respectively herein. Currently, the local buckling is based on the BS 5950-5:1998 and EN 1993-1-3:2006. The distortional buckling is calculated by the direct strength method employing the elastic distortional buckling which is calculated by three available approaches such as Hancock (1995), Schafer and Pekoz (1998), Yu (2005). In the optimisation program, the lateral-torsional buckling based on BS 5950-5:1998, AISI and analytical model of Li (2004) are investigated. For the optimisation program, the programming codes are written for optimisation of channel, zed and sigma beam. The full study has been coded into a computer-based analysis program (MATLAB).
Resumo:
Visual field assessment is a core component of glaucoma diagnosis and monitoring, and the Standard Automated Perimetry (SAP) test is considered up until this moment, the gold standard of visual field assessment. Although SAP is a subjective assessment and has many pitfalls, it is being constantly used in the diagnosis of visual field loss in glaucoma. Multifocal visual evoked potential (mfVEP) is a newly introduced method used for visual field assessment objectively. Several analysis protocols have been tested to identify early visual field losses in glaucoma patients using the mfVEP technique, some were successful in detection of field defects, which were comparable to the standard SAP visual field assessment, and others were not very informative and needed more adjustment and research work. In this study, we implemented a novel analysis approach and evaluated its validity and whether it could be used effectively for early detection of visual field defects in glaucoma. OBJECTIVES: The purpose of this study is to examine the effectiveness of a new analysis method in the Multi-Focal Visual Evoked Potential (mfVEP) when it is used for the objective assessment of the visual field in glaucoma patients, compared to the gold standard technique. METHODS: 3 groups were tested in this study; normal controls (38 eyes), glaucoma patients (36 eyes) and glaucoma suspect patients (38 eyes). All subjects had a two standard Humphrey visual field HFA test 24-2 and a single mfVEP test undertaken in one session. Analysis of the mfVEP results was done using the new analysis protocol; the Hemifield Sector Analysis HSA protocol. Analysis of the HFA was done using the standard grading system. RESULTS: Analysis of mfVEP results showed that there was a statistically significant difference between the 3 groups in the mean signal to noise ratio SNR (ANOVA p<0.001 with a 95% CI). The difference between superior and inferior hemispheres in all subjects were all statistically significant in the glaucoma patient group 11/11 sectors (t-test p<0.001), partially significant 5/11 (t-test p<0.01) and no statistical difference between most sectors in normal group (only 1/11 was significant) (t-test p<0.9). sensitivity and specificity of the HAS protocol in detecting glaucoma was 97% and 86% respectively, while for glaucoma suspect were 89% and 79%. DISCUSSION: The results showed that the new analysis protocol was able to confirm already existing field defects detected by standard HFA, was able to differentiate between the 3 study groups with a clear distinction between normal and patients with suspected glaucoma; however the distinction between normal and glaucoma patients was especially clear and significant. CONCLUSION: The new HSA protocol used in the mfVEP testing can be used to detect glaucomatous visual field defects in both glaucoma and glaucoma suspect patient. Using this protocol can provide information about focal visual field differences across the horizontal midline, which can be utilized to differentiate between glaucoma and normal subjects. Sensitivity and specificity of the mfVEP test showed very promising results and correlated with other anatomical changes in glaucoma field loss.