983 resultados para Catheter ablation


Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To report feasibility and potential benefits of high-frequency jet ventilation (HFJV) in tumor ablations techniques in liver, kidney, and lung lesions. METHODS: This prospective study included 51 patients (14 women, mean age 66 years) bearing 66 tumors (56 hepatic, 5 pulmonary, 5 renal tumors) with a median size of 16 ± 8.7 mm, referred for tumor ablation in an intention-to-treat fashion before preoperative anesthesiology visit. Cancellation and complications of HFJV were prospectively recorded. Anesthesia and procedure duration, as well as mean CO2 capnea, were recorded. When computed tomography guidance was used, 3D spacial coordinates of an anatomical target <2 mm in diameter on 8 slabs of 4 slices of 3.75-mm slice thickness were registered. RESULTS: HFJV was used in 41 of 51 patients. Of the ten patients who were not candidate for HFJV, two patients had contraindication to HFJV (severe COPD), three had lesions invisible under HFJV requiring deep inspiration apnea for tumor targeting, and five patients could not have HFJV because of unavailability of a trained anesthetic team. No specific complication or hypercapnia related to HFJV were observed despite a mean anesthetic duration of 2 h and ventilation performed in procubitus (n = 4) or lateral decubitus (n = 6). Measured internal target movement was 0.3 mm in x- and y-axis and below the slice thickness of 3.75 mm in the z-axis in 11 patients. CONCLUSIONS: HFJV is feasible in 80 % of patients allowing for near immobility of internal organs during liver, kidney, and lung tumor ablation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background- Cardiac hypertrophy involves growth responses to a variety of stimuli triggered by increased workload. It is an independent risk factor for heart failure and sudden death. Mammalian target of rapamycin (mTOR) plays a key role in cellular growth responses by integrating growth factor and energy status signals. It is found in 2 structurally and functionally distinct multiprotein complexes called mTOR complex (mTORC) 1 and mTORC2. The role of each of these branches of mTOR signaling in the adult heart is currently unknown. Methods and Results- We generated mice with deficient myocardial mTORC1 activity by targeted ablation of raptor, which encodes an essential component of mTORC1, during adulthood. At 3 weeks after the deletion, atrial and brain natriuretic peptides and β-myosin heavy chain were strongly induced, multiple genes involved in the regulation of energy metabolism were altered, but cardiac function was normal. Function deteriorated rapidly afterward, resulting in dilated cardiomyopathy and high mortality within 6 weeks. Aortic banding-induced pathological overload resulted in severe dilated cardiomyopathy already at 1 week without a prior phase of adaptive hypertrophy. The mechanism involved a lack of adaptive cardiomyocyte growth via blunted protein synthesis capacity, as supported by reduced phosphorylation of ribosomal S6 kinase 1 and 4E-binding protein 1. In addition, reduced mitochondrial content, a shift in metabolic substrate use, and increased apoptosis and autophagy were observed. Conclusions- Our results demonstrate an essential function for mTORC1 in the heart under physiological and pathological conditions and are relevant for the understanding of disease states in which the insulin/insulin-like growth factor signaling axis is affected such as diabetes mellitus and heart failure or after cancer therapy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Exposure to urinary catheters is considered the most important risk factor for healthcare-associated urinary tract infection (UTI) and is associated with significant morbidity and substantial extra-costs. In this study, we assessed the impact of urinary catheterisation (UC) on symptomatic healthcare-associated UTI among hospitalized patients. METHODS: A nationwide period prevalence survey of healthcare-associated infections was conducted during 1 May to 30 June 2004 in 49 Swiss hospitals and included 8169 adult patients (4313 female; 52.8%) hospitalised in medical, surgical, intermediate, and intensive care wards. Additional data were collected on exposure to UC to investigate factors associated with UTI among hospitalised adult patients exposed and non-exposed to UC. RESULTS: 1917 (23.5%) patients were exposed to UC within the week prior to survey day; 126 (126/8169; 1.5%) developed UTI. Exposure to UC preceded UTI only in 73 cases (58%). By multivariate logistic regression analysis, UTI was independently associated with exposure to UC (odds ratio [OR], 3.9 [95% CI, 2.6-5.9]), female gender (OR, 2.1 [95% CI, 1.4-3.1]), an American Society of Anesthesiologists' score > 2 points (OR, 3.2 [95% CI, 1.1-9.4], and prolonged hospital stay >20 days (OR, 1.9 [95% CI, 1.4-3.2]. Further analysis showed that the only significant factor for UTI with exposure to UC use was prolonged hospital stay >40 days (OR, 2.9 [95% CI, 1.3-6.1], while female gender only showed a tendency (OR, 1.6 [95% CI, 1.0-2.7]. In the absence of exposure to UC, the only significant risk factor for UTI was female gender (OR, 3.3 [95% CI, 1.7-6.5]). CONCLUSIONS: Exposure to UC was the most important risk factor for symptomatic healthcare-associated UTI, but only concerned about half of all patients with UTI. Further investigation is warranted to improve overall infection control strategies for UTI.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: The measurement of cardiac output is a key element in the assessment of cardiac function. Recently, a pulse contour analysis-based device without need for calibration became available (FloTrac/Vigileo, Edwards Lifescience, Irvine, CA). This study was conducted to determine if there is an impact of the arterial catheter site and to investigate the accuracy of this system when compared with the pulmonary artery catheter using the bolus thermodilution technique (PAC). DESIGN: Prospective study. SETTING: The operating room of 1 university hospital. PARTICIPANTS: Twenty patients undergoing cardiac surgery. INTERVENTIONS: CO was determined in parallel by the use of the Flotrac/Vigileo systems in the radial and femoral position (CO_rad and CO_fem) and by PAC as the reference method. Data triplets were recorded at defined time points. The primary endpoint was the comparison of CO_rad and CO_fem, and the secondary endpoint was the comparison with the PAC. MEASUREMENTS AND MAIN RESULTS: Seventy-eight simultaneous data recordings were obtained. The Bland-Altman analysis for CO_fem and CO_rad showed a bias of 0.46 L/min, precision was 0.85 L/min, and the percentage error was 34%. The Bland-Altman analysis for CO_rad and PAC showed a bias of -0.35 L/min, the precision was 1.88 L/min, and the percentage error was 76%. The Bland-Altman analysis for CO_fem and PAC showed a bias of 0.11 L/min, the precision was 1.8 L/min, and the percentage error was 69%. CONCLUSION: The FloTrac/Vigileo system was shown to not produce exactly the same CO data when used in radial and femoral arteries, even though the percentage error was close to the clinically acceptable range. Thus, the impact of the introduction site of the arterial catheter is not negligible. The agreement with thermodilution was low.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Les infections liées aux accès vasculaires sont à l'origine d'une proportion importante des infections nosocomiales. Elles comprennent leur colonisation par des micro-organismes, les infections du site d'insertion et les bactériémies et fongémies qui leur sont associées ou attribuées. Une bactériémie complique l'insertion de 3 à 5 % des voies veineuses, correspondant à une incidence de 2 à 14 épisodes pour 1000 jourcathéters. Cette proportion ne représente toutefois que la partie visible de l'iceberg puisque la plupart des épisodes de sepsis clinique sans foyer infectieux associé sont également considérés comme liés aux accès vasculaires. Après un rappel de leur physiopathologie, cet article passe en revue les éléments importants pour leur prévention, y compris ceux concernant l'utilisation de cathéters imprégnés de désinfectants ou d'antibiotiques. Pour terminer, nous discutons en détail les stratégies préventives globales. Fondées sur la prise en compte d'un ensemble d'éléments spécifiques, ces approches sont centrées sur l'éducation du personnel au respect des règles d'hygiène de base et sur l'introduction de recommandations précises pour l'insertion et l'utilisation des accès vasculaires.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Alteplase has been shown to be effective in preventing central venous access clotting in patients on hemodialysis. Because of a high phosphorus content in its excipient, it can inadvertently contaminate blood samples, leading the physician in care of the patient to erroneously increase dialysis time or change diet in order to control the pseudo-hyperphosphatemia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The plume generated by ablation of hydroxyapatite targets under ArF excimer laser irradiation has been investigated by means of fast intensified CCD-imaging and optical emission spectroscopy. Results have shown that the plume splits into two plasma clouds as it expands. Time and spatial resolved spectra have revealed that under the experiment conditions emission is mostly due to calcium neutral atoms and calcium oxide molecular radicals. Imaging of the plume with the aid of bandpass filters has demonstrated that the emissive species in the larger and faster plasma cloud are calcium neutral atoms, whereas in the smaller and slower one they are calcium oxide molecular radicals

Relevância:

20.00% 20.00%

Publicador:

Resumo:

ArF excimer laser pulses (193 nm, 20 ns, 150 mJ) have been focused on a hydroxyapatite (HA) target in similar conditions to those normally used for thin film deposition. Fast intensified CCD images of HA laser ablation plumes have been taken in vacuum and under different water vapor pressures ranging from 0.01 mbar to 1 mbar. Images of HA ablation in vacuum have shown a plume freely expanding at a constant velocity of 2.3 106 cm/s. HA ablation under a water vapor pressure of 0.01 mbar has revealed an expansion behavior very similar to that of ablation in vacuum. Images taken under a water vapor pressure of 0.1 mbar have shown the formation of a shock structure in the plume. Finally, HA ablation under a water vapor pressure of 1 mbar has revealed the development of some irregularities in the shape of the plume.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The expansion dynamics of the ablation plume generated by KrF laser irradiation of hydroxyapatite targets in a 0.1 mbar water atmosphere has been studied by fast intensified charge coupled device imaging with the aid of optical bandpass filters. The aim of the filters is to isolate the emission of a single species, which allows separate analysis of its expansion. Images obtained without a filter revealed two emissive components in the plume, which expand at different velocities for delay times of up to 1.1 ¿s. The dynamics of the first component is similar to that of a spherical shock wave, whereas the second component, smaller than the first, expands at constant velocity. Images obtained through a 520 nm filter show that the luminous intensity distribution and evolution of emissive atomic calcium is almost identical to those of the first component of the total emission and that there is no contribution from this species to the emission from the second component of the plume. The analysis through a 780 nm filter reveals that atomic oxygen partially diffuses into the water atmosphere and that there is a contribution from this species to the emission from the second component. The last species studied here, calcium oxide, was analyzed by means of a 600 nm filter. The images revealed an intensity pattern more complex than those from the atomic species. Calcium oxide also contributes to the emission from the second component. Finally, all the experiments were repeated in a Ne atmosphere. Comparison of the images revealed chemical reactions between the first component of the plume and the water atmosphere.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes the development of a polyimide/SU-8 catheter-tip MEMS gauge pressure sensor. Finite element analysis was used to investigate critical parameters, impacting on the device design and sensing characteristics. The sensing element of the device was fabricated by polyimide-based micromachining on a flexible membrane, using embedded thin-film metallic wires as piezoresistive elements. A chamber containing this flexible membrane was sealed using an adapted SU-8 bonding technique. The device was evaluated experimentally and its overall performance compared with a commercial silicon-based pressure sensor. Furthermore, the device use was demonstrated by measuring blood pressure and heart rate in vivo.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION. Multimodal strategy targeted at prevention of catheter-related infection combine education to general measures of hygiene with specific guidelines for catheter insertion and dressing (1). OBJECTIVES. In this context, we tested the introduction of chlorhexidine(CHX)-impregnated sponges (2). METHODS. In our 32-beds mixed ICU, prospective surveillance of primary bacteremia and of microbiologically documented catheter-related bloodstream infections (CRBSI) is performed according to standardized definitions. New guidelines for central venous catheter (CVC) dressing combined a CHX-impregnated sponge (BioPatch_) with a transparent occlusive dressing (Tegaderm _) and planning for refection every 7 days. To contain costs, Biopatch_ was used only for internal jugular and femoral sites. Other elements of the prevention were not modified (overall compliance to hand hygiene 65-68%; non coated catheters except for burned patients [173 out of 9,542 patients];maximal sterile barriers for insertion; alcoholic solution ofCHXfor skin disinfection). RESULTS. Median monthly CVC-days increased from 710, to 749, 855 and 965 in 2006, 2007, 2008 and 2009, respectively (p\0.01). Following introduction of the new guidelines (4Q2007), the average monthly rate of infections decreased from 3.7 (95% CI: 2.6-4.8) episodes/1000 CVC-days over the 24 preceding months to 2.2 (95% CI: 1.5-2.8) over the 24 following months (p = 0.031). Dressings needed to be changed every 3-4 days. The decrease of catheter-related infections we observed in all consecutive admitted patients is comparable to that recently showed in a placeborandomized trial2. Further generalization to all CVC and arterial catheters access may be justified. CONCLUSIONS. Our data strongly suggest that combined with occlusive dressings, CHXimpregnated sponges for dressing of all CVC catheters inserted in internal jugular and/or femoral sites, significantly reduces the rate of primary bacteremia and CRBSI. REFERENCES. (1) Eggimann P, Harbarth S, Constantin MN, Touveneau S, Chevrolet JC, Pittet D. Impact of a prevention strategy targeted at vascular-access care on incidence of infections acquired in intensive care. Lancet 2000; 355:1864-1868. (2) Timsit JF, Schwebel C, Bouadma L, Geffroy A, Garrouste-Org, Pease S et al. Chlorhexidine- impregnated sponges and less frequent dressing changes for prevention of catheter-related infections in critically ill adults: a randomized controlled trial. JAMA 2009; 301(12):1231-1241.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectifs: To describe the technique and results of radiofrequency ablation (RFA) of small renal tumors.Matériels et méthodes: 28 patients with median age 79 years were treated with RFA for small renal exophytic tumor (median size 20 mm). Most patients were poor operative candidatesbecause of associated morbidity. Four patients were treated for biopsy proven papillary tumor, 7 for clear cell carcinoma, 2 for oncocytoma and one for renalhepatocellular metastasis. No biopsy sample was obtained for the others because of a typical radiological aspect of RCC.Résultats: All patients but one were treated successfully in one session under combined ultrasound and CT guidance using either Radionics 2000 cool-tip or Bostonscientific expandable needles, one was treated in two sessions. One Splenic, 3 colic and 1 pancreatic displacement with CO2 injection and one injection of G5%solution in the costo-phrenic recessus were done in order to protect adjacent organs. Two complications were observed, one splenic iatrogenic lesion treated byembolization and one renal pelvis stenosis treated with JJ stent. After a mean follow-up of 20 months, no patient developped local recurrence on MRI follow-up.Conclusion: RFA is a simple and efficient technique pending on strict selected criteria (small size < 3 cm and exophytic lesion). Long local control is obtained with minimalmorbidity.