970 resultados para CLINICAL MEASUREMENT


Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES:: This study was designed to apply the rapid Elecsys(R) S100 immunoassay for real-time measurement of S100 protein serum levels indicating acute brain damage in patients undergoing carotid artery stenting (CAS) or endarterectomy (CEA). DESIGN AND METHODS:: Data of 14 CAS patients were compared to those of 43 CEA and 14 control patients undergoing coronary angiography (CA). S100 serum levels were measured by the full-automatic Elecsys(R) S100 immunoassay and compared to those obtained by the well-established LIA-mat(R) S100 system. RESULTS:: In contrast to CAS and CA patients, median S100 serum levels of CEA patients significantly increased to 0.24 ng/mL before declamping, but subsequently returned to baseline. Three CEA patients with neurological deficits showed sustained elevated S100 levels 6 h after extubation. Absolute S100 values were not significantly different between the two methods. Bland-Altman plot analyses displayed a good agreement, mostly indicating slightly smaller values applying the Elecsys(R) S100 system. CONCLUSIONS:: The Elecsys(R) S100 system appears to be suitable for rapid real-time detection of neurological deficits in patients undergoing CAS and CEA. Persistent elevations of Elecsys(R) S100 levels during CEA were associated with prolonged neurological disorders, whereas transient increases seem to represent impaired blood-brain barrier integrity without neurological deficits.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We propose a new method for fitting proportional hazards models with error-prone covariates. Regression coefficients are estimated by solving an estimating equation that is the average of the partial likelihood scores based on imputed true covariates. For the purpose of imputation, a linear spline model is assumed on the baseline hazard. We discuss consistency and asymptotic normality of the resulting estimators, and propose a stochastic approximation scheme to obtain the estimates. The algorithm is easy to implement, and reduces to the ordinary Cox partial likelihood approach when the measurement error has a degenerative distribution. Simulations indicate high efficiency and robustness. We consider the special case where error-prone replicates are available on the unobserved true covariates. As expected, increasing the number of replicate for the unobserved covariates increases efficiency and reduces bias. We illustrate the practical utility of the proposed method with an Eastern Cooperative Oncology Group clinical trial where a genetic marker, c-myc expression level, is subject to measurement error.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: Nitric oxide (NO), one of the most powerful endogenous vasodilators, is thought to play a major role in the development of delayed vasospasm in patients with subarachnoid hemorrhage (SAH). However, the role of the production of cerebral NO in patients with SAH is not known. In other SAH studies, NO metabolites such as nitrite and nitrate have been demonstrated to be decreased in cerebrospinal fluid and in plasma. METHODS: In this study, a microdialysis probe was used, along with a multiparameter sensor, to measure NO metabolites, brain tissue oxygen tension, brain tissue carbon dioxide tension, and pH in the cortex of patients with severe SAH who were at risk for developing secondary brain damage and vasospasm. NO metabolites, glucose, and lactate were analyzed in the dialysates to determine the time course of NO metabolite changes and to test the interrelationship between the analytes and clinical variables. RESULTS: Brain tissue oxygen tension was strongly correlated to dialysate nitrate and nitrite (r2 = 0.326; P < 0.001); however, no correlation was noted between brain tissue oxygen tension and NO metabolites in cerebrospinal fluid (r2 = 0.018; P = 0.734). No significant correlation between NO production, brain tissue carbon dioxide tension, and dialysate glucose and lactate was observed. CONCLUSION: Cerebral ischemia and compromised substrate delivery are often responsible for high morbidity rates and poor outcomes after SAH. The relationship between brain tissue oxygen and cerebral NO metabolites that we demonstrate suggests that substrate delivery and NO are linked in the pathophysiology of vasospasm after SAH.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: The interrupter technique is increasingly used in preschool children to assess airway resistance (Rint). Use of a bacterial filter is essential for prevention of cross-infection in a clinical setting. It is not known how large an effect this extra resistance and compliance exert upon interrupter measurements, especially on obstructive airways and in smaller children. We aim to determine the contribution of the filter to Rint, in a sample of children attending lung function testing at an asthma clinic. METHODS: Interrupter measurements were performed according to ATS/ERS guidelines during quiet normal breathing at an expiratory flow trigger of 200 ml s(-1), with the child seated upright with cheeks supported and wearing a nose clip. A minimum of 10 interrupter measurements was made with and without a bacterial filter. Spirometric and plethysmographic tests were also performed. RESULTS: A small but significant difference (0.12 (95% CI 0.06-0.17) kPa s L(-1), P = 0.0002) with 2x SD of 0.34 kPa s L(-1) was observed between Rint with and without filter in 39 children, with a large spread. This difference was not dependent on Rint magnitude, age or height, nor on lung function parameters (effective resistance, forced expiratory volume in 1 sec, and maximal expiratory flow at 50% of expired vital capacity). CONCLUSIONS: A bacterial filter causes a small difference but is not clinically significant, with a wide spread comparable to the variability of the technique and recommended cut-offs for assessing repeatability and bronchodilation. Age, height or severity of obstruction need not be corrected for in general.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: We determined and compared urethral pressure measurements using air charged and microtip catheters in a prospective, single-blind, randomized trial. MATERIALS AND METHODS: A consecutive series of 64 women referred for urodynamic investigation underwent sequential urethral pressure measurements using an air charged and a microtip catheter in randomized order. Patients were blinded to the type and sequence of catheter used. Agreement between the 2 catheter systems was assessed using the Bland and Altman 95% limits of agreement method. RESULTS: Intraclass correlation coefficients of air charged and microtip catheters for maximum urethral closure pressure at rest were 0.97 and 0.93, and for functional profile length they were 0.9 and 0.78, respectively. Pearson's correlation coefficients and Lin's concordance coefficients of air charged and microtip catheters were r = 0.82 and rho = 0.79 for maximum urethral closure pressure at rest, and r = 0.73 and rho = 0.7 for functional profile length, respectively. When applying the Bland and Altman method, air charged catheters gave higher readings than microtip catheters for maximum urethral closure pressure at rest (mean difference 7.5 cm H(2)O) and functional profile length (mean difference 1.8 mm). There were wide 95% limits of agreement for differences in maximum urethral closure pressure at rest (-24.1 to 39 cm H(2)O) and functional profile length (-7.7 to 11.3 mm). CONCLUSIONS: For urethral pressure measurement the air charged catheter is at least as reliable as the microtip catheter and it generally gives higher readings. However, air charged and microtip catheters cannot be used interchangeably for clinical purposes because of insufficient agreement. Hence, clinicians should be aware that air charged and microtip catheters may yield completely different results, and these differences should be acknowledged during clinical decision making.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Epidemiological data on halitosis are rare. In this study we evaluated the prevalence of halitosis in the population of the city of Bern, Switzerland, using a standardized questionnaire and clinical examination. First of all, a standardized questionnaire was filled out by all 419 participants. In the clinical examination, 'objective' values for halitosis were gathered through two different organoleptic assessments and by the measurement of volatile sulfur compounds (VSC). Additionally, tongue coating and the modified periodontal screening index (PSI) were evaluated for each participant. The questionnaire revealed that 32% of all subjects sometimes or often experienced halitosis. The organoleptic evaluation (grade 0-5) identified 48 persons with grade 3 and higher. Measurement of VSC identified 117 subjects (28%) with readings of >or= 75 parts per billion (ppb). Tongue coating, modified PSI, and smoking were significantly associated with higher organoleptic scores, and tongue coating and smoking were associated with higher VSC values. For about one-third of the Bernese city population, halitosis seems to pose an oral health problem. Only a weak correlation between self-reported halitosis and either organoleptic or VSC measurements could be detected.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Sound epidemiologic data on halitosis are rare. We evaluated the prevalence of halitosis in a young male adult population in Switzerland using a standardized questionnaire and clinical examination. METHODS: Six hundred twenty-six Swiss Army recruits aged 18 to 25 years (mean: 20.3 years) were selected as study subjects. First, a standardized questionnaire focusing on dental hygiene, self-reported halitosis, smoking, and alcohol consumption was filled out by all participants. In the clinical examination, objective values for the presence of halitosis were gathered through an organoleptic assessment of the breath odor and the measurement of volatile sulfur compounds (VSCs). Additionally, tongue coating, plaque index, and probing depths were evaluated for each recruit. RESULTS: The questionnaire revealed that only 17% of all included recruits had never experienced halitosis. The organoleptic evaluation (grades 0 to 3) identified eight persons with grade 3, 148 persons with grade 2, and 424 persons with grade 1 or 0. The calculation of the Pearson correlation coefficient to evaluate the relationship among the three methods of assessing halitosis revealed little to no correlation. The organoleptic score showed high reproducibility (kappa = 0.79). Tongue coating was the only influencing factor found to contribute to higher organoleptic scores and higher VSC values. CONCLUSIONS: Oral malodor seemed to pose an oral health problem for about one-fifth of 20-year-old Swiss males questioned. No correlation between self-reported halitosis and organoleptic or VSC measurements could be detected. Although the organoleptic method described here offers a high reproducibility, the lack of correlation between VSC values and organoleptic scores has to be critically addressed. For further studies assessing new organoleptic scores, a validated index should always be included as a direct control.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Because of the important morbidity and mortality associated with osteoporosis, it is essential to detect subjects at risk by screening methods, such as bone quantitative ultrasounds (QUSs). Several studies showed that QUS could predict fractures. None, however, compared prospectively different QUS devices, and few data of quality controls (QCs) have been published. The Swiss Evaluation of the Methods of Measurement of Osteoporotic Fracture Risk is a prospective multicenter study that compared three QUSs for the assessment of hip fracture risk in a population of 7609 women age >/=70 yr. Because the inclusion phase lasted 20 mo, and because 10 centers participated in this study, QC became a major issue. We therefore developed a QC procedure to assess the stability and precision of the devices, and for their cross-calibration. Our study focuses on the two heel QUSs. The water bath system (Achilles+) had a higher precision than the dry system (Sahara). The QC results were highly dependent on temperature. QUS stability was acceptable, but Sahara must be calibrated regularly. A sufficient homogeneity among all the Sahara devices could be demonstrated, whereas significant differences were found among the Achilles+ devices. For speed of sound, 52% of the differences among the Achilles+ was explained by the water s temperature. However, for broadband ultrasound attenuation, a maximal difference of 23% persisted after adjustment for temperature. Because such differences could influence measurements in vivo, it is crucial to develop standardized phantoms to be used in prospective multicenter studies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate the agreement of blood pressure measurements and hypertension scores obtained by use of 3 indirect arterial blood pressure measurement devices in hospitalized dogs. Design-Diagnostic test evaluation. ANIMALS: 29 client-owned dogs. PROCEDURES: 5 to 7 consecutive blood pressure readings were obtained from each dog on each of 3 occasions with a Doppler ultrasonic flow detector, a standard oscillometric device (STO), and a high-definition oscillometric device (HDO). RESULTS: When the individual sets of 5 to 7 readings were evaluated, the coefficient of variation for systolic arterial blood pressure (SAP) exceeded 20% for 0% (Doppler), 11 % (STO), and 28% (HDO) of the sets of readings. After readings that exceeded a 20% coefficient of variation were discarded, repeatability was within 25 (Doppler), 37 (STO), and 39 (HDO) mm Hg for SAP. Correlation of mean values among the devices was between 0.47 and 0.63. Compared with Doppler readings, STO underestimated and HDO overestimated SAP. Limits of agreement between mean readings of any 2 devices were wide. With the hypertension scale used to score SAP, the intraclass correlation of scores was 0.48. Linear-weighted inter-rater reliability between scores was 0.40 (Doppler vs STO), 0.38 (Doppler vs HDO), and 0.29 (STO vs HDO). CONCLUSIONS AND CLINICAL RELEVANCE: Results of this study suggested that no meaningful clinical comparison can be made between blood pressure readings obtained from the same dog with different indirect blood pressure measurement devices.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Identifying and comparing different steady states is an important task for clinical decision making. Data from unequal sources, comprising diverse patient status information, have to be interpreted. In order to compare results an expressive representation is the key. In this contribution we suggest a criterion to calculate a context-sensitive value based on variance analysis and discuss its advantages and limitations referring to a clinical data example obtained during anesthesia. Different drug plasma target levels of the anesthetic propofol were preset to reach and maintain clinically desirable steady state conditions with target controlled infusion (TCI). At the same time systolic blood pressure was monitored, depth of anesthesia was recorded using the bispectral index (BIS) and propofol plasma concentrations were determined in venous blood samples. The presented analysis of variance (ANOVA) is used to quantify how accurately steady states can be monitored and compared using the three methods of measurement.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The objective of the study was to determine if there are sex-based differences in the prevalence and clinical outcomes of subclinical peripheral artery disease (PAD). We evaluated the sex-specific associations of ankle-brachial index (ABI) with clinical cardiovascular disease outcomes in 2797 participants without prevalent clinical PAD and with a baseline ABI measurement in the Health, Aging, and Body Composition study. The mean age was 74 years, 40% were black, and 52% were women. Median follow-up was 9.37 years. Women had a similar prevalence of ABI < 0.9 (12% women versus 11% men; P = 0.44), but a higher prevalence of ABI 0.9-1.0 (15% versus 10%, respectively; P < 0.001). In a fully adjusted model, ABI < 0.9 was significantly associated with higher coronary heart disease (CHD) mortality, incident clinical PAD and incident myocardial infarction in both women and men. ABI < 0.9 was significantly associated with incident stroke only in women. ABI 0.9-1.0 was significantly associated with CHD death in both women (hazard ratio 4.84, 1.53-15.31) and men (3.49, 1.39-8.72). However, ABI 0.9-1.0 was significantly associated with incident clinical PAD (3.33, 1.44-7.70) and incident stroke (2.45, 1.38-4.35) only in women. Subclinical PAD was strongly associated with adverse CV events in both women and men, but women had a higher prevalence of subclinical PAD.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The planning of refractive surgical interventions is a challenging task. Numerical modeling has been proposed as a solution to support surgical intervention and predict the visual acuity, but validation on patient specific intervention is missing. The purpose of this study was to validate the numerical predictions of the post-operative corneal topography induced by the incisions required for cataract surgery. The corneal topography of 13 patients was assessed preoperatively and postoperatively (1-day and 30-day follow-up) with a Pentacam tomography device. The preoperatively acquired geometric corneal topography – anterior, posterior and pachymetry data – was used to build patient-specific finite element models. For each patient, the effects of the cataract incisions were simulated numerically and the resulting corneal surfaces were compared to the clinical postoperative measurements at one day and at 30-days follow up. Results showed that the model was able to reproduce experimental measurements with an error on the surgically induced sphere of 0.38D one day postoperatively and 0.19D 30 days postoperatively. The standard deviation of the surgically induced cylinder was 0.54D at the first postoperative day and 0.38D 30 days postoperatively. The prediction errors in surface elevation and curvature were below the topography measurement device accuracy of ±5μm and ±0.25D after the 30-day follow-up. The results showed that finite element simulations of corneal biomechanics are able to predict post cataract surgery within topography measurement device accuracy. We can conclude that the numerical simulation can become a valuable tool to plan corneal incisions in cataract surgery and other ophthalmosurgical procedures in order to optimize patients' refractive outcome and visual function.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: We investigated the psychometric properties of a short questionnaire for combined assessment of different perceived stress management skills in the general population and tested whether scores relate to physiological stress reactivity. METHODS: For psychometric evaluation, we determined the factor structure of the questionnaire and investigated its measurement invariance in the participant groups and over time in three different independent samples representing the general population (total N=332). Reliability was tested by estimating test-retest reliability, internal consistency, and item reliabilities. We examined convergent and criterion validity using selected criterion variables. For endocrine validation, 35 healthy non-smoking and medication-free men in a laboratory study and 35 male and female employees in a workplace study underwent an acute standardized psychosocial stress task. We assessed stress management skills and measured salivary cortisol before and several times up to 60 min (workplace study) and 120 min (laboratory study) after stress. Potential confounders were controlled. RESULTS: The factor structure of the questionnaire consists of five scales reflecting acceptably distinct stress management skills such as cognitive strategies, use of social support, relaxation strategies, anger regulation, and perception of bodily tension. This factor structure was stable across participant groups and over time. Internal consistencies, item reliabilities, and test-retest reliabilities met established statistical requirements. Convergent and criterion validity were also established. In both endocrine validation studies, higher stress management skills were independently associated with lower cortisol stress reactivity (p's<.029). CONCLUSIONS: Our findings suggest that the questionnaire has good psychometric properties and that it relates to subjective psychological and objective physiological stress indicators. Therefore, the instrument seems a suitable measure for differential assessment of stress management skills in the general population.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The ACTH receptor (MC2R) is expressed predominantly in the adrenal cortex, but is one of five G protein-coupled, seven-transmembrane melanocortin receptors (MCRs), all of which bind ACTH to some degree. Testing of MC2R activity is difficult because most cells express endogenous MCRs; hence, ACTH will elicit background activation of assayable reporter systems. Inactivating mutations of MC2R lead to hereditary unresponsiveness to ACTH, also known as familial glucocorticoid deficiency (FGD). These patients are usually seen in early childhood with very low cortisol concentrations, normal mineralocorticoids, hyperpigmentation, and increased bodily growth. Several MC2R mutations have been reported in FGD, but assays of the activities of these mutants are cumbersome. We saw two patients with typical clinical findings of FGD. Genetic analysis showed that patient 1 was homozygous for the mutation R137W, and patient 2 was a compound heterozygote for S74I and Y254C. We tested the activity of these mutations in OS-3 cells, which are unresponsive to ACTH but have intact downstream cAMP signal transduction. OS-3 cells transfected with a cAMP-responsive luciferase reporter plasmid (pCREluc) were unresponsive to ACTH, but cotransfection with a vector expressing human MC2R increased luciferase activity more than 40-fold. Addition of ACTH to cells cotransfected with the pCREluc reporter and wild-type MC2R activated luciferase expression with a 50% effective concentration of 5.5 x 10(-9) M ACTH, which is similar to previously reported values. By contrast, the MC2R mutant R137W had low activity, and the S74I or Y254C mutants elicited no measurable response. This assay provides excellent sensitivity in an easily assayed transient transfection system, providing a more rapid and efficient measurement of ACTH receptor activity.