996 resultados para rod-cone interaction


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Travelling by public transport is usually regarded as boring and uninteresting. Refraining from talking to the stranger next to you may be due to limitations that are self-imposed and further corroborated by social expectations and cultural norms that govern behaviour in public space. Our design research into passenger interactions on board of urban commuter trains has informed the development of the TrainRoulette prototype – a mobile app for situated, real-time chats between train passengers. We study the impact of our design intervention on shaping perceptions of the train journey experience. Moreover, we are interested in the implications of such ICT-mediated interactions within train journeys for stimulating social offline interactions and new forms of passenger engagement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Road safety barriers are used to redirect traffic at roadside work-zones. When filled with water, these barriers are able to withstand low to moderate impact speeds up to 50kmh-1. Despite this feature, Portable Water-filled barriers (PWFB) face challenges such as large lateral displacements, tearing and breakage during impact; especially at higher speeds. This study explores the use of composite action to enhance the crashworthiness of PWFBs and enable their usage at higher speeds. Initially, energy absorption capability of water in PWFB is investigated. Then, composite action of the PWFB with the introduction of steel frame is considered to evaluate its enhanced impact performance. Findings of the study show that the initial height of the impact must be lower than the free surface level of water in a PWFB in order for the water to provide significant crash energy absorption. In general, an impact of a road barrier with 80% filled is a good estimation. Furthermore, the addition of a composite structure greatly reduces the probability of tearing by decreasing the strain and impact energy transferred to the shell container. This allows the water to remain longer in the barrier to absorb energy via inertial displacements and sloshing response. Information from this research will aid in the design of new generation roadside safety structures aimed to increase safety in modern roadways.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this thesis, three mathematical models describing the growth of solid tumour incorporating the host tissue and the immune system response are developed and investigated. The initial model describes the dynamics of the growing tumour and immune response before being extended in the second model by introducing a time-varying dendritic cell-based treatment strategy. Finally, in the third model, we present a mathematical model of a growing tumour using a hybrid cellular automata. These models can provide information to pre-experimental work to assist in designing more effective and efficient laboratory experiments related to tumour growth and interactions with the immune system and immunotherapy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The interaction of water with the fluorine-covered (001) surface of anatase titanium dioxide (TiO2) has been studied within the framework of density functional theory (DFT). Our results show that water dissociation is unfavorable due to repulsive interactions between surface fluorine and oxygen. We also found that the reaction of hydrofluoric acid with a surface hydroxyl group to form a surface Ti–F bond is exothermic, while the removal of fluorine from the surface needs additional energy of about half an eV. Therefore, water molecules are predicted to remain intact at the interface with the F-terminated anatase (001).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: The motivation for developing megavoltage (and kilovoltage) cone beam CT (MV CBCT) capabilities in the radiotherapy treatment room was primarily based on the need to improve patient set-up accuracy. There has recently been an interest in using the cone beam CT data for treatment planning. Accurate treatment planning, however, requires knowledge of the electron density of the tissues receiving radiation in order to calculate dose distributions. This is obtained from CT, utilising a conversion between CT number and electron density of various tissues. The use of MV CBCT has particular advantages compared to treatment planning with kilovoltage CT in the presence of high atomic number materials and requires the conversion of pixel values from the image sets to electron density. Therefore, a study was undertaken to characterise the pixel value to electron density relationship for the Siemens MV CBCT system, MVision, and determine the effect, if any, of differing the number of monitor units used for acquisition. If a significant difference with number of monitor units was seen then pixel value to ED conversions may be required for each of the clinical settings. The calibration of the MV CT images for electron density offers the possibility for a daily recalculation of the dose distribution and the introduction of new adaptive radiotherapy treatment strategies. Methods: A Gammex Electron Density CT Phantom was imaged with the MVCB CT system. The pixel value for each of the sixteen inserts, which ranged from 0.292 to 1.707 relative electron density to the background solid water, was determined by taking the mean value from within a region of interest centred on the insert, over 5 slices within the centre of the phantom. These results were averaged and plotted against the relative electron densities of each insert with a linear least squares fit was preformed. This procedure was performed for images acquired with 5, 8, 15 and 60 monitor units. Results: The linear relationship between MVCT pixel value and ED was demonstrated for all monitor unit settings and over a range of electron densities. The number of monitor units utilised was found to have no significant impact on this relationship. Discussion: It was found that the number of MU utilised does not significantly alter the pixel value obtained for different ED materials. However, to ensure the most accurate and reproducible MV to ED calibration, one MU setting should be chosen and used routinely. To ensure accuracy for the clinical situation this MU setting should correspond to that which is used clinically. If more than one MU setting is used clinically then an average of the CT values acquired with different numbers of MU could be utilized without loss in accuracy. Conclusions: No significant differences have been shown between the pixel value to ED conversion for the Siemens MV CT cone beam unit with change in monitor units. Thus as single conversion curve could be utilised for MV CT treatment planning. To fully utilise MV CT imaging for radiotherapy treatment planning further work will be undertaken to ensure all corrections have been made and dose calculations verified. These dose calculations may be either for treatment planning purposes or for reconstructing the delivered dose distribution from transit dosimetry measurements made using electronic portal imaging devices. This will potentially allow the cumulative dose distribution to be determined through the patient’s multi-fraction treatment and adaptive treatment strategies developed to optimize the tumour response.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Road safety barriers are used to redirect traffic at roadside work-zones. When filled with water, these barriers are able to withstand low to moderate impact speeds up to 50kmh-1. Despite this feature, there are challenges when using portable water-filled barriers (PWFBs) such as large lateral displacements as well as tearing and breakage during impact, especially at higher speeds. In this study, the authors explore the use of composite action to enhance the crashworthiness of PWFBs and enable their use at higher speeds. Initially, we investigated the energy absorption capability of water in PWFB. Then, we considered the composite action of a PWFB with the introduction of a steel frame to evaluate its impact on performance. Findings of the study show that the initial height of impact must be lower than the free surface level of water in a PWFB for the water to provide significant crash energy absorption. In general, impact of a road barrier that is 80% filled is a good estimation. Furthermore, the addition of a composite structure greatly reduces the probability of tearing by decreasing the strain and impact energy transferred to the shell container. This allows the water to remain longer in the barrier to absorb energy via inertial displacement and sloshing response. Information from this research will aid in the design of next generation roadside safety structures aimed to increase safety on modern roadways.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Flat-detector, cone-beam computed tomography (CBCT) has enormous potential to improve the accuracy of treatment delivery in image-guided radiotherapy (IGRT). To assist radiotherapists in interpreting these images, we use a Bayesian statistical model to label each voxel according to its tissue type. Methods: The rich sources of prior information in IGRT are incorporated into a hidden Markov random field (MRF) model of the 3D image lattice. Tissue densities in the reference CT scan are estimated using inverse regression and then rescaled to approximate the corresponding CBCT intensity values. The treatment planning contours are combined with published studies of physiological variability to produce a spatial prior distribution for changes in the size, shape and position of the tumour volume and organs at risk (OAR). The voxel labels are estimated using the iterated conditional modes (ICM) algorithm. Results: The accuracy of the method has been evaluated using 27 CBCT scans of an electron density phantom (CIRS, Inc. model 062). The mean voxel-wise misclassification rate was 6.2%, with Dice similarity coefficient of 0.73 for liver, muscle, breast and adipose tissue. Conclusions: By incorporating prior information, we are able to successfully segment CBCT images. This could be a viable approach for automated, online image analysis in radiotherapy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hyperhomocysteinemia (hHcy) has been associated with an increased risk of cardiovascular disease and stroke. Essential hypertension (EH), a polygenic condition, has also been associated with increased risk of cardiovascular related disorders. To investigate the role of the homocysteine (Hcy) metabolism pathway in hypertension we conducted a case-control association study of Hcy pathway gene variants in a cohort of Caucasian hypertensives and age- and sex-matched normotensives. We genotyped two polymorphisms in the methylenetetrahydrofolate reductase gene (MTHFR C677T and MTHFR A1298C), one polymorphism in the methionine synthase reductase gene (MTRR A66G), and one polymorphism in the methylenetetrahydrofolate dehydrogenase 1 gene (MTHFD1 G1958A) and assessed their association with hypertension using chi-square analysis. We also performed a multifactor dimensionality reduction (MDR) analysis to investigate any potential epistatic interactions among the four polymorphisms and EH. None of the four polymorphisms was significantly associated with EH and although we found a moderate synergistic interaction between MTHFR A1298C and MTRR A66G, the association of the interaction model with EH was not statistically significant (

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Migraine is a common neurological condition with a complex mode of inheritance. Steroid hormones have long been implicated in migraine, although their role remains unclear. Our investigation considered that genes involved in hormonal pathways may play a role in migraine susceptibility. We therefore investigated the androgen receptor (AR) CAG repeat, and the progesterone receptor (PR) PROGINS insert by cross-sectional association analysis. The results showed no association with the AR CAG repeat in our study group of 275 migraineurs and 275 unrelated controls. Results of the PR PROGINS analysis showed a significant difference in the same cohort, and in an independent follow-up study population of 300 migraineurs and 300 unrelated controls. Analysis of the genotypic risk groups of both populations together indicated that individuals who carried the PROGINS insert were 1.8 times more likely to suffer migraine. Interaction analysis of the PROGINS variant with our previously reported associated ESR1 594A variant showed that individuals who possessed at least one copy of both risk alleles were 3.2 times more likely to suffer migraine. Hence, variants of these steroid hormone receptor genes appear to act synergistically to increase the risk of migraine by a factor of three.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Drawing on three case studies of work in the fields of participatory design, interaction design and electronic arts, we reflect on the implications of these studies for haptic interface research. We propose three themes: gestural; emergent; and expressive; as signposts for a program of research into haptic interaction that could point the way towards novel approaches to haptic interaction and move us from optic to haptic ways of seeing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cone-beam computed tomography (CBCT) has enormous potential to improve the accuracy of treatment delivery in image-guided radiotherapy (IGRT). To assist radiotherapists in interpreting these images, we use a Bayesian statistical model to label each voxel according to its tissue type. The rich sources of prior information in IGRT are incorporated into a hidden Markov random field model of the 3D image lattice. Tissue densities in the reference CT scan are estimated using inverse regression and then rescaled to approximate the corresponding CBCT intensity values. The treatment planning contours are combined with published studies of physiological variability to produce a spatial prior distribution for changes in the size, shape and position of the tumour volume and organs at risk. The voxel labels are estimated using iterated conditional modes. The accuracy of the method has been evaluated using 27 CBCT scans of an electron density phantom. The mean voxel-wise misclassification rate was 6.2\%, with Dice similarity coefficient of 0.73 for liver, muscle, breast and adipose tissue. By incorporating prior information, we are able to successfully segment CBCT images. This could be a viable approach for automated, online image analysis in radiotherapy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Myopia (short-sightedness) is a common ocular disorder of children and young adults. Studies primarily using animal models have shown that the retina controls eye growth and the outer retina is likely to have a key role. One theory is that the proportion of L (long-wavelength-sensitive) and M (medium-wavelength-sensitive) cones is related to myopia development; with a high L/M cone ratio predisposing individuals to myopia. However, not all dichromats (persons with red-green colour vision deficiency) with extreme L/M cone ratios have high refractive errors. We predict that the L/M cone ratio will vary in individuals with normal trichromatic colour vision but not show a systematic difference simply due to refractive error. The aim of this study was to determine if L/M cone ratios in the central 30° are different between myopic and emmetropic young, colour normal adults. Information about L/M cone ratios was determined using the multifocal visual evoked potential (mfVEP). The mfVEP can be used to measure the response of visual cortex to different visual stimuli. The visual stimuli were generated and measurements performed using the Visual Evoked Response Imaging System (VERIS 5.1). The mfVEP was measured when the L and M cone systems were separately stimulated using the method of silent substitution. The method of silent substitution alters the output of three primary lights, each with physically different spectral distributions to control the excitation of one or more photoreceptor classes without changing the excitation of the unmodulated photoreceptor classes. The stimulus was a dartboard array subtending 30° horizontally and 30° vertically on a calibrated LCD screen. The m-sequence of the stimulus was 215-1. The N1-P1 amplitude ratio of the mfVEP was used to estimate the L/M cone ratio. Data were collected for 30 young adults (22 to 33 years of age), consisting of 10 emmetropes (+0.3±0.4 D) and 20 myopes (–3.4±1.7 D). The stimulus and analysis techniques were confirmed using responses of two dichromats. For the entire participant group, the estimated central L/M cone ratios ranged from 0.56 to 1.80 in the central 3°-13° diameter ring and from 0.94 to 1.91 in the more peripheral 13°-30° diameter ring. Within 3°-13°, the mean L/M cone ratio of the emmetropic group was 1.20±0.33 and the mean was similar, 1.20±0.26, for the myopic group. For the 13°-30° ring, the mean L/M cone ratio of the emmetropic group was 1.48±0.27 and it was slightly lower in the myopic group, 1.30±0.27. Independent-samples t-test indicated no significant difference between the L/M cone ratios of the emmetropic and myopic group for either the central 3°-13° ring (p=0.986) or the more peripheral 13°-30° ring (p=0.108). The similar distributions of estimated L/M cone ratios in the sample of emmetropes and myopes indicates that there is likely to be no association between the L/M cone ratio and refractive error in humans.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Executive Summary This project has commenced an exploration of learning and information experiences in the QUT Cube. Understanding learning in this environment has the potential to inform current implementations and future project development. In this report, we present early findings from the first phase of an investigation into what makes learning possible in the context of a giant interactive multi-media display such as the QUT Cube, which is an award-winning configuration that hosts several projects.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

With this special issue, we draw attention to the growing and diverse field of HCI researchers exploring the interstices of food, technology and everyday practices. This special issue builds on the CHI workshop of the same name (Comber et al., 2012a), where we brought together the community of researchers that take food as a point from which to understand people and design technology. The workshop aimed to ‘to attend to the practical and theoretical difficulties in designing for human–food interactions in everyday life’ identifying four thematic areas of food practices – health and wellbeing; sustainability; food experiences; and alternative food cultures. These practical and theoretical difficulties are evident in the papers that we present here, though the distinction between our four themes, premised by complexities of food practices, is a little less evident. Thus, in the papers that follow we explore how the social, technological, cultural and methodological intertwine in the field of human–food interaction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Portable water-filled barriers (PWFB) are roadside structures used to separate moving traffic from work-zones. Numerical PWFB modelling is preferred in the design stages prior to actual testing. This paper aims to study the fluid-structure interaction of PWFB under vehicular impact using several methods. The strategy to treat water as non-structural mass was proposed and the errors were investigated. It was found that water can be treated with the FEA-NSM model for velocities higher than 80kmh-1. However, full SPH/FEA model is still the best treatment for water and necessary for lower impact velocities. The findings in this paper can be used as guidelines for modelling and designing PWFB.