998 resultados para reliability algorithms


Relevância:

20.00% 20.00%

Publicador:

Resumo:

STUDY DESIGN: Reliability and case-control injury study. OBJECTIVES: 1) To determine if a novel device, designed to measure eccentric knee flexors strength via the Nordic hamstring exercise (NHE), displays acceptable test-retest reliability; 2) to determine normative values for eccentric knee flexors strength derived from the device in individuals without a history of hamstring strain injury (HSI) and; 3) to determine if the device could detect weakness in elite athletes with a previous history of unilateral HSI. BACKGROUND: HSIs and reinjuries are the most common cause of lost playing time in a number of sports. Eccentric knee flexors weakness is a major modifiable risk factor for future HSIs, however there is a lack of easily accessible equipment to assess this strength quality. METHODS: Thirty recreationally active males without a history of HSI completed NHEs on the device on 2 separate occasions. Intraclass correlation coefficients (ICCs), typical error (TE), typical error as a co-efficient of variation (%TE), and minimum detectable change at a 95% confidence interval (MDC95) were calculated. Normative strength data were determined using the most reliable measurement. An additional 20 elite athletes with a unilateral history of HSI within the previous 12 months performed NHEs on the device to determine if residual eccentric muscle weakness existed in the previously injured limb. RESULTS: The device displayed high to moderate reliability (ICC = 0.83 to 0.90; TE = 21.7 N to 27.5 N; %TE = 5.8 to 8.5; MDC95 = 76.2 to 60.1 N). Mean±SD normative eccentric flexors strength, based on the uninjured group, was 344.7 ± 61.1 N for the left and 361.2 ± 65.1 N for the right side. The previously injured limbs were 15% weaker than the contralateral uninjured limbs (mean difference = 50.3 N; 95% CI = 25.7 to 74.9N; P < .01), 15% weaker than the normative left limb data (mean difference = 50.0 N; 95% CI = 1.4 to 98.5 N; P = .04) and 18% weaker than the normative right limb data (mean difference = 66.5 N; 95% CI = 18.0 to 115.1 N; P < .01). CONCLUSIONS: The experimental device offers a reliable method to determine eccentric knee flexors strength and strength asymmetry and revealed residual weakness in previously injured elite athletes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The reliability analysis is crucial to reducing unexpected down time, severe failures and ever tightened maintenance budget of engineering assets. Hazard based reliability methods are of particular interest as hazard reflects the current health status of engineering assets and their imminent failure risks. Most existing hazard models were constructed using the statistical methods. However, these methods were established largely based on two assumptions: one is the assumption of baseline failure distributions being accurate to the population concerned and the other is the assumption of effects of covariates on hazards. These two assumptions may be difficult to achieve and therefore compromise the effectiveness of hazard models in the application. To address this issue, a non-linear hazard modelling approach is developed in this research using neural networks (NNs), resulting in neural network hazard models (NNHMs), to deal with limitations due to the two assumptions for statistical models. With the success of failure prevention effort, less failure history becomes available for reliability analysis. Involving condition data or covariates is a natural solution to this challenge. A critical issue for involving covariates in reliability analysis is that complete and consistent covariate data are often unavailable in reality due to inconsistent measuring frequencies of multiple covariates, sensor failure, and sparse intrusive measurements. This problem has not been studied adequately in current reliability applications. This research thus investigates such incomplete covariates problem in reliability analysis. Typical approaches to handling incomplete covariates have been studied to investigate their performance and effects on the reliability analysis results. Since these existing approaches could underestimate the variance in regressions and introduce extra uncertainties to reliability analysis, the developed NNHMs are extended to include handling incomplete covariates as an integral part. The extended versions of NNHMs have been validated using simulated bearing data and real data from a liquefied natural gas pump. The results demonstrate the new approach outperforms the typical incomplete covariates handling approaches. Another problem in reliability analysis is that future covariates of engineering assets are generally unavailable. In existing practices for multi-step reliability analysis, historical covariates were used to estimate the future covariates. Covariates of engineering assets, however, are often subject to substantial fluctuation due to the influence of both engineering degradation and changes in environmental settings. The commonly used covariate extrapolation methods thus would not be suitable because of the error accumulation and uncertainty propagation. To overcome this difficulty, instead of directly extrapolating covariate values, projection of covariate states is conducted in this research. The estimated covariate states and unknown covariate values in future running steps of assets constitute an incomplete covariate set which is then analysed by the extended NNHMs. A new assessment function is also proposed to evaluate risks of underestimated and overestimated reliability analysis results. A case study using field data from a paper and pulp mill has been conducted and it demonstrates that this new multi-step reliability analysis procedure is able to generate more accurate analysis results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dedicated Short Range Communication (DSRC) is the emerging key technology supporting cooperative road safety systems within Intelligent Transportation Systems (ITS). The DSRC protocol stack includes a variety of standards such as IEEE 802.11p and SAE J2735. The effectiveness of the DSRC technology depends on not only the interoperable cooperation of these standards, but also on the interoperability of DSRC devices manufactured by various manufacturers. To address the second constraint, the SAE defines a message set dictionary under the J2735 standard for construction of device independent messages. This paper focuses on the deficiencies of the SAE J2735 standard being developed for deployment in Vehicular Ad-hoc Networks (VANET). In this regard, the paper discusses the way how a Basic Safety Message (BSM) as the fundamental message type defined in SAE J2735 is constructed, sent and received by safety communication platforms to provide a comprehensive device independent solution for Cooperative ITS (C-ITS). This provides some insight into the technical knowledge behind the construction and exchange of BSMs within VANET. A series of real-world DSRC data collection experiments was conducted. The results demonstrate that the reliability and throughput of DSRC highly depend on the applications utilizing the medium. Therefore, an active application-dependent medium control measure, using a novel message-dissemination frequency controller, is introduced. This application level message handler improves the reliability of both BSM transmissions/receptions and the Application layer error handling which is extremely vital to decentralized congestion control (DCC) mechanisms.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Conjunctival ultraviolet autofluorescence (UVAF) photography was developed to detect and characterise pre-clinical sunlight-induced UV damage. The reliability of this measurement and its relationship to outdoor activity are currently unknown. METHODS: 599 people aged 16-85 years in the cross-sectional Norfolk Island Eye Study were included in the validation study. 196 UVAF individual photographs (49 people) and 60 UVAF photographs (15 people) of Norfolk Island Eye Study participants were used for intra- and inter-observer reliability assessment, respectively. Conjunctival UVAF was measured using UV photography. UVAF area was calculated using computerised methods by one grader on two occasions (intra-observer analysis) or two graders (inter-observer analysis). Outdoor activity category, during summer and winter separately, was determined with a UV questionnaire. Total UVAF equalled the area measured in four conjunctival areas (nasal/temporal conjunctiva of right and left eyes). RESULTS: Intra-observer (ρ_c=0.988, 95% CI 0.967 to 0.996, p<0.001), and inter-observer concordance correlation coefficients (ρ_c=0.924, 95% CI 0.870 to 0.956, p<0.001) of total UVAF exceeded 0.900. When grouped according to 10 mm(2) total UVAF increments, intra- and inter-observer reliability was very good (κ=0.81) and good (κ=0.71), respectively. Increasing time outdoors was strongly with increasing total UVAF in summer and winter (p(trend) <0.001). CONCLUSION: Intra- and inter-observer reliability of conjunctival UVAF is high. In this population, UVAF correlates strongly with the authors' survey-based assessment of time spent outdoors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Illumina's Infinium SNP BeadChips are extensively used in both small and large-scale genetic studies. A fundamental step in any analysis is the processing of raw allele A and allele B intensities from each SNP into genotype calls (AA, AB, BB). Various algorithms which make use of different statistical models are available for this task. We compare four methods (GenCall, Illuminus, GenoSNP and CRLMM) on data where the true genotypes are known in advance and data from a recently published genome-wide association study. Results In general, differences in accuracy are relatively small between the methods evaluated, although CRLMM and GenoSNP were found to consistently outperform GenCall. The performance of Illuminus is heavily dependent on sample size, with lower no call rates and improved accuracy as the number of samples available increases. For X chromosome SNPs, methods with sex-dependent models (Illuminus, CRLMM) perform better than methods which ignore gender information (GenCall, GenoSNP). We observe that CRLMM and GenoSNP are more accurate at calling SNPs with low minor allele frequency than GenCall or Illuminus. The sample quality metrics from each of the four methods were found to have a high level of agreement at flagging samples with unusual signal characteristics. Conclusions CRLMM, GenoSNP and GenCall can be applied with confidence in studies of any size, as their performance was shown to be invariant to the number of samples available. Illuminus on the other hand requires a larger number of samples to achieve comparable levels of accuracy and its use in smaller studies (50 or fewer individuals) is not recommended.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

How do agents with limited cognitive capacities flourish in informationally impoverished or unexpected circumstances? Aristotle argued that human flourishing emerged from knowing about the world and our place within it. If he is right, then the virtuous processes that produce knowledge, best explain flourishing. Influenced by Aristotle, virtue epistemology defends an analysis of knowledge where beliefs are evaluated for their truth and the intellectual virtue or competences relied on in their creation. However, human flourishing may emerge from how degrees of ignorance are managed in an uncertain world. Perhaps decision-making in the shadow of knowledge best explains human wellbeing—a Bayesian approach? In this dissertation I argue that a hybrid of virtue and Bayesian epistemologies explains human flourishing—what I term homeostatic epistemology. Homeostatic epistemology supposes that an agent has a rational credence p when p is the product of reliable processes aligned with the norms of probability theory; whereas an agent knows that p when a rational credence p is the product of reliable processes such that: 1) p meets some relevant threshold for belief (such that the agent acts as though p were true and indeed p is true), 2) p coheres with a satisficing set of relevant beliefs and, 3) the relevant set of beliefs is coordinated appropriately to meet the integrated aims of the agent. Homeostatic epistemology recognizes that justificatory relationships between beliefs are constantly changing to combat uncertainties and to take advantage of predictable circumstances. Contrary to holism, justification is built up and broken down across limited sets like the anabolic and catabolic processes that maintain homeostasis in the cells, organs and systems of the body. It is the coordination of choristic sets of reliably produced beliefs that create the greatest flourishing given the limitations inherent in the situated agent.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Nutrition screening is usually administered by nurses. However, most studies on nutrition screening tools have not used nurses to validate the tools. The 3-Minute Nutrition Screening (3-MinNS) assesses weight loss, dietary intake and muscle wastage, with the composite score of each used to determine risk of malnutrition. The aim of the study was to determine the validity and reliability of 3-MinNS administered by nurses, who are the intended assessors. Methods: In this cross sectional study, three ward-based nurses screened 121 patients aged 21 years and over using 3-MinNS in three wards within 24 hours of admission. A dietitian then assessed the patients’ nutritional status using Subjective Global Assessment within 48 hours of admission, whilst blinded to the results of the screening. To assess the reliability of 3-MinNS, 37 patients screened by the first nurse were re-screened by a second nurse within 24 hours, who was blinded to the results of the first nurse. The sensitivity, specificity and best cutoff score for 3-MinNS were determined using the Receiver Operator Characteristics Curve. Results: The best cutoff score to identify all patients at risk of malnutrition using 3-MinNS was three, with sensitivity of 89% and specificity of 88%. This cutoff point also identified all (100%) severely malnourished patients. There was strong correlation between 3-MinNS and SGA (r=0.78, p<0.001). The agreement between two nurses conducting the 3-MinNS tool was 78.3%. Conclusion: 3-Minute Nutrition Screening is a valid and reliable tool for nurses to identify patients at risk of malnutrition.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In most intent recognition studies, annotations of query intent are created post hoc by external assessors who are not the searchers themselves. It is important for the field to get a better understanding of the quality of this process as an approximation for determining the searcher's actual intent. Some studies have investigated the reliability of the query intent annotation process by measuring the interassessor agreement. However, these studies did not measure the validity of the judgments, that is, to what extent the annotations match the searcher's actual intent. In this study, we asked both the searchers themselves and external assessors to classify queries using the same intent classification scheme. We show that of the seven dimensions in our intent classification scheme, four can reliably be used for query annotation. Of these four, only the annotations on the topic and spatial sensitivity dimension are valid when compared with the searcher's annotations. The difference between the interassessor agreement and the assessor-searcher agreement was significant on all dimensions, showing that the agreement between external assessors is not a good estimator of the validity of the intent classifications. Therefore, we encourage the research community to consider using query intent classifications by the searchers themselves as test data.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Nutrition screening is usually administered by nurses. However, most studies on nutrition screening tools have not used nurses to validate the tools. The 3-Minute Nutrition Screening (3-MinNS) assesses weight loss, dietary intake and muscle wastage, with the composite score of each used to determine risk of malnutrition. The aim of the study was to determine the validity and reliability of 3-MinNS administered by nurses, who are the intended assessors. Methods In this cross sectional study, three ward-based nurses screened 121 patients aged 21 years and over using 3-MinNS in three wards within 24 hours of admission. A dietitian then assessed the patients’ nutritional status using Subjective Global Assessment within 48 hours of admission, whilst blinded to the results of the screening. To assess the reliability of 3-MinNS, 37 patients screened by the first nurse were re-screened by a second nurse within 24 hours, who was blinded to the results of the first nurse. The sensitivity, specificity and best cutoff score for 3-MinNS were determined using the Receiver Operator Characteristics Curve. Results The best cutoff score to identify all patients at risk of malnutrition using 3-MinNS was three, with sensitivity of 89% and specificity of 88%. This cutoff point also identified all (100%) severely malnourished patients. There was strong correlation between 3-MinNS and SGA (r=0.78, p<0.001). The agreement between two nurses conducting the 3-MinNS tool was 78.3%. Conclusion 3-Minute Nutrition Screening is a valid and reliable tool for nurses to identify patients at risk of malnutrition.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Despite the emerging use of treadmills integrated with pressure platforms as outcome tools in both clinical and research settings, published evidence regarding the measurement properties of these new systems is limited. This study evaluated the within– and between–day repeatability of spatial, temporal and vertical ground reaction forces measured by a treadmill system instrumented with a capacitance–based pressure platform. Methods Thirty three healthy adults (mean age, 21.5 ± 2.8 years; height, 168.4 ± 9.9 cm; and mass, 67.8 ± 18.6 kg), walked barefoot on a treadmill system (FDM–THM–S, Zebris Medical GmbH) on three separate occasions. For each testing session, participants set their preferred pace but were blinded to treadmill speed. Spatial (foot rotation, step width, stride and step length), temporal (stride and step times, duration of stance, swing and single and double support) and peak vertical ground reaction force variables were collected over a 30–second capture period, equating to an average of 52 ± 5 steps of steady–state walking. Testing was repeated one week following the initial trial and again, for a third time, 20 minutes later. Repeated measures ANOVAs within a generalized linear modelling framework were used to assess between–session differences in gait parameters. Agreement between gait parameters measured within the same day (session 2 and 3) and between days (session 1 and 2; 1 and 3) were evaluated using the 95% repeatability coefficient. Results There were statistically significant differences in the majority (14/16) of temporal, spatial and kinetic gait parameters over the three test sessions (P < .01). The minimum change that could be detected with 95% confidence ranged between 3% and 17% for temporal parameters, 14% and 33% for spatial parameters, and 4% and 20% for kinetic parameters between days. Within–day repeatability was similar to that observed between days. Temporal and kinetic gait parameters were typically more consistent than spatial parameters. The 95% repeatability coefficient for vertical force peaks ranged between ± 53 and ± 63 N. Conclusions The limits of agreement in spatial parameters and ground reaction forces for the treadmill system encompass previously reported changes with neuromuscular pathology and footwear interventions. These findings provide clinicians and researchers with an indication of the repeatability and sensitivity of the Zebris treadmill system to detect changes in common spatiotemporal gait parameters and vertical ground reaction forces.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE To compare different reliability coefficients (exact agreement, and variations of the kappa (generalised, Cohen's and Prevalence Adjusted and Biased Adjusted (PABAK))) for four physiotherapists conducting visual assessments of scapulae. DESIGN Inter-therapist reliability study. SETTING Research laboratory. PARTICIPANTS 30 individuals with no history of neck or shoulder pain were recruited with no obvious significant postural abnormalities. MAIN OUTCOME MEASURES Ratings of scapular posture were recorded in multiple biomechanical planes under four test conditions (at rest, and while under three isometric conditions) by four physiotherapists. RESULTS The magnitude of discrepancy between the two therapist pairs was 0.04 to 0.76 for Cohen's kappa, and 0.00 to 0.86 for PABAK. In comparison, the generalised kappa provided a score between the two paired kappa coefficients. The difference between mean generalised kappa coefficients and mean Cohen's kappa (0.02) and between mean generalised kappa and PABAK (0.02) were negligible, but the magnitude of difference between the generalised kappa and paired kappa within each plane and condition was substantial; 0.02 to 0.57 for Cohen's kappa and 0.02 to 0.63 for PABAK, respectively. CONCLUSIONS Calculating coefficients for therapist pairs alone may result in inconsistent findings. In contrast, the generalised kappa provided a coefficient close to the mean of the paired kappa coefficients. These findings support an assertion that generalised kappa may lead to a better representation of reliability between three or more raters and that reliability studies only calculating agreement between two raters should be interpreted with caution. However, generalised kappa may mask more extreme cases of agreement (or disagreement) that paired comparisons may reveal.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the field of diagnostics of rolling element bearings, the development of sophisticated techniques, such as Spectral Kurtosis and 2nd Order Cyclostationarity, extended the capability of expert users to identify not only the presence, but also the location of the damage in the bearing. Most of the signal-analysis methods, as the ones previously mentioned, result in a spectrum-like diagram that presents line frequencies or peaks in the neighbourhood of some theoretical characteristic frequencies, in case of damage. These frequencies depend only on damage position, bearing geometry and rotational speed. The major improvement in this field would be the development of algorithms with high degree of automation. This paper aims at this important objective, by discussing for the first time how these peaks can draw away from the theoretical expected frequencies as a function of different working conditions, i.e. speed, torque and lubrication. After providing a brief description of the peak-patterns associated with each type of damage, this paper shows the typical magnitudes of the deviations from the theoretical expected frequencies. The last part of the study presents some remarks about increasing the reliability of the automatic algorithm. The research is based on experimental data obtained by using artificially damaged bearings installed in a gearbox.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The overuse of antibiotics is becoming an increasing concern. Antibiotic resistance, which increases both the burden of disease, and the cost of health services, is perhaps the most profound impact of antibiotics overuse. Attempts have been made to develop instruments to measure the psychosocial constructs underlying antibiotics use, however, none of these instruments have undergone thorough psychometric validation. This study evaluates the psychometric properties of the Parental Perceptions on Antibiotics (PAPA) scales. The PAPA scales attempt to measure the factors influencing parental use of antibiotics in children. Methods: 1111 parents of children younger than 12 years old were recruited from primary schools’ parental meetings in the Eastern Province of Saudi Arabia from September 2012 to January 2013. The structure of the PAPA instrument was validated using Confirmatory Factor Analysis (CFA) with measurement model fit evaluated using the raw and scaled χ2, Goodness of Fit Index, and Root Mean Square Error of Approximation. Results: A five-factor model was confirmed with the model showing good fit. Constructs in the model include: Knowledge and Beliefs, Behaviors, Sources of information, Adherence, and Awareness about antibiotics resistance. The instrument was shown to have good internal consistency, and good discriminant and convergent validity. Conclusion: The availability of an instrument able to measure the psychosocial factors underlying antibiotics usage allows the risk factors underlying antibiotic use and overuse to now be investigated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The advances made within the aviation industry over the past several decades have significantly improved the availability, affordability and convenience of air travel and have been greatly beneficial in both social and economic terms. Air transport has developed into an irreplaceable service being relied on by millions of people each day and as such airports have become critical elements of national infrastructure to facilitate the movement of people and goods. As components of critical infrastructure (CI), airports are integral parts of a national economy supporting regional as well as national trade, commercial activity and employment. Therefore, any disruption or crisis which impacts the continuity of operations at airports can have significant negative consequences for the airport as a business, for the local economy and other nodes of transport infrastructure as well as for society. Due to the highly dynamic and volatile environment in which airports operate in, the aviation industry has faced many different challenges over the years ranging from terrorist attacks such as September 11, to health crises such as the SARS epidemic to system breakdowns such as the recent computer system outage at Virgin Blue Airlines in Australia. All these events have highlighted the vulnerability of airport systems to a range of disturbances as well as the gravity and widespread impact of any kind of discontinuity in airport functions. Such incidents thus emphasise the need for increasing resilience and reliability of airports and ensuring business continuity in the event of a crisis...