946 resultados para partial least square (PLS)
Resumo:
In this work, it was developed and validated methodologies that were based on the use of Infrared Spectroscopy Mid (MIR) combined with multivariate calibration Square Partial Least (PLS) to quantify adulterants such as soybean oil and residual soybean oil in methyl and ethyl palm biodiesels in the concentration range from 0.25 to 30.00 (%), as well as to determine methyl and ethyl palm biodiesel content in their binary mixtures with diesel in the concentration range from 0.25 to 30.00 (%). The prediction results showed that PLS models constructed are satisfactory. Errors Mean Square Forecast (RMSEP) of adulteration and content determination showed values of 0.2260 (%), with mean error (EM) with values below 1.93 (%). The models also showed a strong correlation between actual and predicted values, staying above 0.99974. No systematic errors were observed, in accordance to ASTM E1655- 05. Thus the built PLS models, may be a promising alternative in the quality control of this fuel for possible adulterations or to content determination.
Resumo:
Considering the social and economic importance that the milk has, the objective of this study was to evaluate the incidence and quantifying antimicrobial residues in the food. The samples were collected in dairy industry of southwestern Paraná state and thus they were able to cover all ten municipalities in the region of Pato Branco. The work focused on the development of appropriate models for the identification and quantification of analytes: tetracycline, sulfamethazine, sulfadimethoxine, chloramphenicol and ampicillin, all antimicrobials with health interest. For the calibration procedure and validation of the models was used the Infrared Spectroscopy Fourier Transform associated with chemometric method based on Partial Least Squares regression (PLS - Partial Least Squares). To prepare a work solution antimicrobials, the five analytes of interest were used in increasing doses, namely tetracycline from 0 to 0.60 ppm, sulfamethazine 0 to 0.12 ppm, sulfadimethoxine 0 to 2.40 ppm chloramphenicol 0 1.20 ppm and ampicillin 0 to 1.80 ppm to perform the work with the interest in multiresidues analysis. The performance of the models constructed was evaluated through the figures of merit: mean square error of calibration and cross-validation, correlation coefficients and offset performance ratio. For the purposes of applicability in this work, it is considered that the models generated for Tetracycline, Sulfadimethoxine and Chloramphenicol were considered viable, with the greatest predictive power and efficiency, then were employed to evaluate the quality of raw milk from the region of Pato Branco . Among the analyzed samples by NIR, 70% were in conformity with sanitary legislation, and 5% of these samples had concentrations below the Maximum Residue permitted, and is also satisfactory. However 30% of the sample set showed unsatisfactory results when evaluating the contamination with antimicrobials residues, which is non conformity related to the presence of antimicrobial unauthorized use or concentrations above the permitted limits. With the development of this work can be said that laboratory tests in the food area, using infrared spectroscopy with multivariate calibration was also good, fast in analysis, reduced costs and with minimum generation of laboratory waste. Thus, the alternative method proposed meets the quality concerns and desired efficiency by industrial sectors and society in general.
Resumo:
Dissertação (mestrado)—Universidade de Brasília, Instituto de Química, Programa de Pós-Graduação em Química, 2015.
Resumo:
The aim of this study was to compare REML/BLUP and Least Square procedures in the prediction and estimation of genetic parameters and breeding values in soybean progenies. F(2:3) and F(4:5) progenies were evaluated in the 2005/06 growing season and the F(2:4) and F(4:6) generations derived thereof were evaluated in 2006/07. These progenies were originated from two semi-early, experimental lines that differ in grain yield. The experiments were conducted in a lattice design and plots consisted of a 2 m row, spaced 0.5 m apart. The trait grain yield per plot was evaluated. It was observed that early selection is more efficient for the discrimination of the best lines from the F(4) generation onwards. No practical differences were observed between the least square and REML/BLUP procedures in the case of the models and simplifications for REML/BLUP used here.
Resumo:
Natural products have widespread biological activities, including inhibition of mitochondrial enzyme systems. Some of these activities, for example cytotoxicity, may be the result of alteration of cellular bioenergetics. Based on previous computer-aided drug design (CADD) studies and considering reported data on structure-activity relationships (SAR), an assumption regarding the mechanism of action of natural products against parasitic infections involves the NADH-oxidase inhibition. In this study, chemometric tools, such as: Principal Component Analysis (PCA), Consensus PCA (CPCA), and partial least squares regression (PLS), were applied to a set of forty natural compounds, acting as NADH-oxidase inhibitors. The calculations were performed using the VolSurf+ program. The formalisms employed generated good exploratory and predictive results. The independent variables or descriptors having a hydrophobic profile were strongly correlated to the biological data.
Resumo:
Quality control of toys for avoiding children exposure to potentially toxic elements is of utmost relevance and it is a common requirement in national and/or international norms for health and safety reasons. Laser-induced breakdown spectroscopy (LIBS) was recently evaluated at authors` laboratory for direct analysis of plastic toys and one of the main difficulties for the determination of Cd. Cr and Pb was the variety of mixtures and types of polymers. As most norms rely on migration (lixiviation) protocols, chemometric classification models from LIBS spectra were tested for sampling toys that present potential risk of Cd, Cr and Pb contamination. The classification models were generated from the emission spectra of 51 polymeric toys and by using Partial Least Squares - Discriminant Analysis (PLS-DA), Soft Independent Modeling of Class Analogy (SIMCA) and K-Nearest Neighbor (KNN). The classification models and validations were carried out with 40 and 11 test samples, respectively. Best results were obtained when KNN was used, with corrected predictions varying from 95% for Cd to 100% for Cr and Pb. (C) 2011 Elsevier B.V. All rights reserved.
Resumo:
A novel flow-based strategy for implementing simultaneous determinations of different chemical species reacting with the same reagent(s) at different rates is proposed and applied to the spectrophotometric catalytic determination of iron and vanadium in Fe-V alloys. The method relies on the influence of Fe(II) and V(IV) on the rate of the iodide oxidation by Cr(VI) under acidic conditions, the Jones reducing agent is then needed Three different plugs of the sample are sequentially inserted into an acidic KI reagent carrier stream, and a confluent Cr(VI) solution is added downstream Overlap between the inserted plugs leads to a complex sample zone with several regions of maximal and minimal absorbance values. Measurements performed on these regions reveal the different degrees of reaction development and tend to be more precise Data are treated by multivariate calibration involving the PLS algorithm The proposed system is very simple and rugged Two latent variables carried out ca 95% of the analytical information and the results are in agreement with ICP-OES. (C) 2010 Elsevier B V. All rights reserved.
Resumo:
Chlorpheniramine maleate (CLOR) enantiomers were quantified by ultraviolet spectroscopy and partial least squares regression. The CLOR enantiomers were prepared as inclusion complexes with beta-cyclodextrin and 1-butanol with mole fractions in the range from 50 to 100%. For the multivariate calibration the outliers were detected and excluded and variable selection was performed by interval partial least squares and a genetic algorithm. Figures of merit showed results for accuracy of 3.63 and 2.83% (S)-CLOR for root mean square errors of calibration and prediction, respectively. The ellipse confidence region included the point for the intercept and the slope of 1 and 0, respectively. Precision and analytical sensitivity were 0.57 and 0.50% (S)-CLOR, respectively. The sensitivity, selectivity, adjustment, and signal-to-noise ratio were also determined. The model was validated by a paired t test with the results obtained by high-performance liquid chromatography proposed by the European pharmacopoeia and circular dichroism spectroscopy. The results showed there was no significant difference between the methods at the 95% confidence level, indicating that the proposed method can be used as an alternative to standard procedures for chiral analysis.
Resumo:
In this note we show by counter-example that the direct product of two weak uniquely completable partial latin squares is not necessarily a uniquely completable partial latin square. This counter-example rejects a conjecture by Gower (see [3]) on the direct product of two uniquely completable partial latin squares.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
O objetivo deste estudo é o desenvolvimento e validação de métodos espectroscópicos (espectroscopia NIR) que possam vir a substituir os métodos químicos convencionais, para quantificação de grupos hidróxilo em resinas alquídicas. As resinas alquídicas estudadas neste trabalho são normalmente utilizadas em sistemas de revestimento de dois componentes, em que os seus grupos hidróxilo reagem com pré-polímeros de isocianato para formar revestimentos de alta dureza. Por este motivo e por questões processuais ligadas à estequiometria da reação existente na aplicação referida, é extremamente importante a quantificação destes grupos. O método mais comum de quantificação de grupos hidróxilo é conhecido como método de titulação. Este é um método demorado, pois cada medição implica um procedimento experimental de cerca de duas horas, para além de ser muito dispendioso, a nível económico. Foram estudadas as influências da temperatura, heterogeneidade e nível de enchimento da célula na recolha do espectro. As conclusões dos estudos mencionados levaram à fixação de um tempo ideal de permanência da célula dentro da câmara do espectrofotómetro antes da medição do espectro. Para além disto, conclui-se que para lotes standard, a heterogeneidade não é uma variável significativa. O nível da célula deve ser mantido constante. Os métodos desenvolvidos, baseados na norma de qualidade ISO 15063:2011, foram construídos a partir de algoritmos de Partial Least Squares Regression (PLS), utilizando um equipamento NIRVIS, Büchi©. Foram obtidos bons coeficientes de regressão linear para a Resina A (R2>0,9). Quanto aos restantes resultados, estes indicam a possibilidade de aplicação em resinas do mesmo tipo. Este método proporciona resultados 8 vezes mais rápidos e com custos em material que representam 1% do método standard.
Resumo:
O objetivo deste estudo é o desenvolvimento e validação de métodos espectroscópicos (espectroscopia NIR) que possam vir a substituir os métodos químicos convencionais, para quantificação de grupos hidróxilo em resinas alquídicas. As resinas alquídicas estudadas neste trabalho são normalmente utilizadas em sistemas de revestimento de dois componentes, em que os seus grupos hidróxilo reagem com pré-polímeros de isocianato para formar revestimentos de alta dureza. Por este motivo e por questões processuais ligadas à estequiometria da reação existente na aplicação referida, é extremamente importante a quantificação destes grupos. O método mais comum de quantificação de grupos hidróxilo é conhecido como método de titulação. Este é um método demorado, pois cada medição implica um procedimento experimental de cerca de duas horas, para além de ser muito dispendioso, a nível económico. Foram estudadas as influências da temperatura, heterogeneidade e nível de enchimento da célula na recolha do espectro. As conclusões dos estudos mencionados levaram à fixação de um tempo ideal de permanência da célula dentro da câmara do espectrofotómetro antes da medição do espectro. Para além disto, conclui-se que para lotes standard, a heterogeneidade não é uma variável significativa. O nível da célula deve ser mantido constante. Os métodos desenvolvidos, baseados na norma de qualidade ISO 15063:2011, foram construídos a partir de algoritmos de Partial Least Squares Regression (PLS), utilizando um equipamento NIRVIS, Büchi©. Foram obtidos bons coeficientes de regressão linear para a Resina A (R2>0,9). Quanto aos restantes resultados, estes indicam a possibilidade de aplicação em resinas do mesmo tipo. Este método proporciona resultados 8 vezes mais rápidos e com custos em material que representam 1% do método standard.
Resumo:
Os estudos da satisfação e lealdade do cliente em ambiente Business-to-Business têm emergido devido ao interesse práctico e académico. Recorreu-se a um caso práctico de uma empresa de software internacional, ESRI, a operar em Portugal com modelo de negócio B2B e comportamento de compra extensivo. Desenvolveu-se um modelo estrutural com 11 variáveis latentes: lealdade; satisfação; imagem; atmosfera; cooperação; adaptação; processos; tecnologia; orientação ao cliente; competências; colaboradores e comunicação. Foram analisadas 304 respostas ao questionário de satisfação e de seguida aplicou-se o modelo a seis grupos de clientes segmentados de acordo com a contribuição do cliente para as receitas e o comportamento no processo de decisão de compra. Recorreu-se a modelos SEM (Structural Equation Modelling) com estimação dos parâmetros através da metodologia PLS (partial Least Squares). Os resultados mostram nos seis segmentos, que os valores da empresa, a cooperação através da competência dos colaboradores e da orientação ao cliente e a tecnologia são factores mais importantes para a satisfação e lealdade dos clientes.
Resumo:
Mestrado em Contabilidade, Fiscalidade e Finanças Empresariais