984 resultados para one-phase water flow


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The present study evaluated stress indicators in pacu exposed to ammonia in water under the following conditions: without NH4Cl (0.00 g/L); with 0.0078 g NH4Cl/L; and with 0.078 g NH4Cl/L (pH 8.3 and 27 ºC). After the salt dilution the water flow was interrupted and reestablished in 24 hours. Sampling occurred prior to the addition of NH4Cl (control) and after 12, 24 and 48 hours. Glycaemia increased only in fish with the highest salt concentration when compared with group control, regardless of time, and at 24 hours, regardless of treatment. Plasma ammonia, highest in fish exposed to the highest NH4Cl concentration, decreased progressively up to 48 hours. Plasma chloride only decreased in fish not exposed to salt when compared with control and osmolality increased after 24 hours. Hematocrit (Ht), number and volume of erythrocytes and hemoglobin did not change when NH4Cl was added; Ht decrease was reported after 12 hours, but it was not followed by the other blood parameters. The results show tolerance of the pacu to ammonia in the environment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Our aim was to assess the importance of dunging gutters filled with water in finishing barns for the prevalence of pigs shedding Salmonella enterica. Some finishing barns in Brazil are provided with a dunging-gutter system which consists of a continuous water flow at the back of solid-floored adjacent pens. Because there is transfer of faecal material between adjacent pens by water in this system and the faecal-oral route of transmission is so important for enteric pathogens, we tested the hypothesis that the presence of this kind of dunging-gutter system in finishing barns affects the prevalence of slaughter-age pigs shedding salmonella organisms in their faeces. The cross-sectional study was conducted on six farms each having barns with and barns without a dunging-gutter system. Breeding, management, nutritional and seasonal factors were similar in both barns on each farm. The two systems did not differ in prevalence of pigs shedding salmonella organisms. Five S. enterica scrotypes were isolated: S. Agona, S. Javiana, S. Rissen, S. Sandiego and S. Senftenberg. (C) 2002 Elsevier B.V. B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The usual programs for load flow calculation were in general developped aiming the simulation of electric energy transmission, subtransmission and distribution systems. However, the mathematical methods and algorithms used by the formulations were based, in majority, just on the characteristics of the transmittion systems, which were the main concern focus of engineers and researchers. Though, the physical characteristics of these systems are quite different from the distribution ones. In the transmission systems, the voltage levels are high and the lines are generally very long. These aspects contribute the capacitive and inductive effects that appear in the system to have a considerable influence in the values of the interest quantities, reason why they should be taken into consideration. Still in the transmission systems, the loads have a macro nature, as for example, cities, neiborhoods, or big industries. These loads are, generally, practically balanced, what reduces the necessity of utilization of three-phase methodology for the load flow calculation. Distribution systems, on the other hand, present different characteristics: the voltage levels are small in comparison to the transmission ones. This almost annul the capacitive effects of the lines. The loads are, in this case, transformers, in whose secondaries are connected small consumers, in a sort of times, mono-phase ones, so that the probability of finding an unbalanced circuit is high. This way, the utilization of three-phase methodologies assumes an important dimension. Besides, equipments like voltage regulators, that use simultaneously the concepts of phase and line voltage in their functioning, need a three-phase methodology, in order to allow the simulation of their real behavior. For the exposed reasons, initially was developped, in the scope of this work, a method for three-phase load flow calculation in order to simulate the steady-state behaviour of distribution systems. Aiming to achieve this goal, the Power Summation Algorithm was used, as a base for developing the three phase method. This algorithm was already widely tested and approved by researchers and engineers in the simulation of radial electric energy distribution systems, mainly for single-phase representation. By our formulation, lines are modeled in three-phase circuits, considering the magnetic coupling between the phases; but the earth effect is considered through the Carson reduction. It s important to point out that, in spite of the loads being normally connected to the transformer s secondaries, was considered the hypothesis of existence of star or delta loads connected to the primary circuit. To perform the simulation of voltage regulators, a new model was utilized, allowing the simulation of various types of configurations, according to their real functioning. Finally, was considered the possibility of representation of switches with current measuring in various points of the feeder. The loads are adjusted during the iteractive process, in order to match the current in each switch, converging to the measured value specified by the input data. In a second stage of the work, sensibility parameters were derived taking as base the described load flow, with the objective of suporting further optimization processes. This parameters are found by calculating of the partial derivatives of a variable in respect to another, in general, voltages, losses and reactive powers. After describing the calculation of the sensibility parameters, the Gradient Method was presented, using these parameters to optimize an objective function, that will be defined for each type of study. The first one refers to the reduction of technical losses in a medium voltage feeder, through the installation of capacitor banks; the second one refers to the problem of correction of voltage profile, through the instalation of capacitor banks or voltage regulators. In case of the losses reduction will be considered, as objective function, the sum of the losses in all the parts of the system. To the correction of the voltage profile, the objective function will be the sum of the square voltage deviations in each node, in respect to the rated voltage. In the end of the work, results of application of the described methods in some feeders are presented, aiming to give insight about their performance and acuity

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The usual programs for load flow calculation were in general developped aiming the simulation of electric energy transmission, subtransmission and distribution systems. However, the mathematical methods and algorithms used by the formulations were based, in majority, just on the characteristics of the transmittion systems, which were the main concern focus of engineers and researchers. Though, the physical characteristics of these systems are quite different from the distribution ones. In the transmission systems, the voltage levels are high and the lines are generally very long. These aspects contribute the capacitive and inductive effects that appear in the system to have a considerable influence in the values of the interest quantities, reason why they should be taken into consideration. Still in the transmission systems, the loads have a macro nature, as for example, cities, neiborhoods, or big industries. These loads are, generally, practically balanced, what reduces the necessity of utilization of three-phase methodology for the load flow calculation. Distribution systems, on the other hand, present different characteristics: the voltage levels are small in comparison to the transmission ones. This almost annul the capacitive effects of the lines. The loads are, in this case, transformers, in whose secondaries are connected small consumers, in a sort of times, mono-phase ones, so that the probability of finding an unbalanced circuit is high. This way, the utilization of three-phase methodologies assumes an important dimension. Besides, equipments like voltage regulators, that use simultaneously the concepts of phase and line voltage in their functioning, need a three-phase methodology, in order to allow the simulation of their real behavior. For the exposed reasons, initially was developped, in the scope of this work, a method for three-phase load flow calculation in order to simulate the steady-state behaviour of distribution systems. Aiming to achieve this goal, the Power Summation Algorithm was used, as a base for developping the three phase method. This algorithm was already widely tested and approved by researchers and engineers in the simulation of radial electric energy distribution systems, mainly for single-phase representation. By our formulation, lines are modeled in three-phase circuits, considering the magnetic coupling between the phases; but the earth effect is considered through the Carson reduction. Its important to point out that, in spite of the loads being normally connected to the transformers secondaries, was considered the hypothesis of existence of star or delta loads connected to the primary circuit. To perform the simulation of voltage regulators, a new model was utilized, allowing the simulation of various types of configurations, according to their real functioning. Finally, was considered the possibility of representation of switches with current measuring in various points of the feeder. The loads are adjusted during the iteractive process, in order to match the current in each switch, converging to the measured value specified by the input data. In a second stage of the work, sensibility parameters were derived taking as base the described load flow, with the objective of suporting further optimization processes. This parameters are found by calculating of the partial derivatives of a variable in respect to another, in general, voltages, losses and reactive powers. After describing the calculation of the sensibility parameters, the Gradient Method was presented, using these parameters to optimize an objective function, that will be defined for each type of study. The first one refers to the reduction of technical losses in a medium voltage feeder, through the installation of capacitor banks; the second one refers to the problem of correction of voltage profile, through the instalation of capacitor banks or voltage regulators. In case of the losses reduction will be considered, as objective function, the sum of the losses in all the parts of the system. To the correction of the voltage profile, the objective function will be the sum of the square voltage deviations in each node, in respect to the rated voltage. In the end of the work, results of application of the described methods in some feeders are presented, aiming to give insight about their performance and acuity

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A critical problem in mature gas wells is the liquid loading. As the reservoir pressure decreases, gas superficial velocities decreases and the drag exerted on the liquid phase may become insufficient to bring all the liquid to the surface. Liquid starts to drain downward, flooding the well and increasing the backpressure which decreases the gas superficial velocity and so on. A popular method to remedy this problem is the Plunger Lift. This method consists of dropping the "plunger"to the bottom of the tubing well with the main production valve closed. When the plunger reaches the well bottom the production valve is opened and the plunger carry the liquid to the surface. However, models presented in literature for predicting the behavior in plunger lift are simplistic, in many cases static (not considering the transient effects). Therefore work presents the development and validation of a numerical algorithm to solve one-dimensional compressible in gas wells using the Finite Volume Method and PRIME techniques for treating coupling of pressure and velocity fields. The code will be then used to develop a dynamic model for the plunger lift which includes the transient compressible flow within the well

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The high concentration of residual oil is one of the greatest problems found in petroleum mature fields. In these reservoirs, different enhanced oil recovery methods (EOR) can be used, highlighting the microemulsion injection. The microemulsion has showed to be efficient in petroleum recovery due to its ability to promote an efficient displacement of the petroleum, acting directly in the residual oil. In this way, this research has as objective the study of microemulsion systems obtained using a commercial surfactant (TP), determining microemulsion thermal stabilities and selecting points inside the pseudoternary phases diagram, evaluating its efficiencies and choosing the best system, that has the following composition: TP as surfactant (S), isopropyl alcohol as co-surfactant (C), kerosene as oil phase, water as aqueous phase, C/S ratio = 1, and 5% sodium p-toluenesulfonate as hydrotope; being observed the following parameters for the selection of the best pseudoternary phases diagram: C/S ratio, co-surfactant nature and addition of hydrotope to the system. The efficiency in petroleum recovery was obtained using two sandstone formation systems: Assu and Botucatu. The study of thermal stabilities showed that as the concentration of active matter in the system increased, the thermal stability also increased. The best thermal stability was obtained using point F (79.56 0C). The system that presented the best recovery percentile between the three selected (3) was composed by: 70% C/S, 2% kerosene and 28% water, with 94% of total recovery efficiency and 60% with microemulsion injection, using the Botucatu formation, that in a general way presented greater efficiencies as compared with the Assu one (81.3% of total recovery efficiency and 38.3% with microemulsion injection)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The main objective of this research was the development and characterization of conventional and modified cationic asphalt emulsions. The asphalt emulsions were developed by using the Petroleum Asphalt Cement (CAP 50-70) from Fazenda Belém (Petrobras -Aracati-Ce). The first step in this research was the development of the oil phase (asphalt + solvent) and the aqueous phase (water + emulsifying agent + acid + additives), separately. During the experiments for the obtaining of the conventional asphalt emulsion, the concentration of each constituent was evaluated. For the obtaining of the oil phase, kerosene was used as solvent at 15 and 20 wt.%. For the development of the aqueous phase, the emulsifying agent was used at 0.3 and 3.0 wt.%, whereas the acid and the additive were set at 0.3 wt.%. The percentage of asphalt in the asphalt emulsion was varied in 50, 55, and 60 wt.% and the heating temperature was set at 120 °C. The aqueous phase in the asphalt emulsion was varied from 16.4 to 34.1 wt.% and the heating temperature was set at 60 °C. After the obtaining of the oil and the aqueous phases, they were added at a colloidal mill, remaining under constant stirring and heating during 15 minutes. Each asphalt emulsion was evaluated considering: sieve analysis, Saybolt Furol viscosity, pH determination, settlement and storage stability, residue by evaporation, and penetration of residue. After the characterization of conventional emulsions, it was chosen the one that presented all properties in accordance with Brazilian specifications (DNER-EM 369/97). This emulsion was used for the development of all modified asphalt emulsions. Three polymeric industrial residues were used as modifier agents: one from a clothing button industry (cutouts of clothing buttons) and two from a footwear industry (cutouts of sandals and tennis shoes soles), all industries located at Rio Grande do Norte State (Brazil).The polymeric residues were added into the asphalt emulsion (1 to 6 wt.%) and the same characterization rehearsals were accomplished. After characterization, it were developed the cold-mix asphalts. It was used the Marshall mix design. For cold-mix asphalt using the conventional emulsion, it was used 5, 6 and 7 wt.% asphalt emulsion. The conventional mixtures presented stability values according Brazilian specification (DNER-369/97). For mixtures containing asphalt modified emulsions, it was observed that the best results were obtained with emulsions modified by button residue

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Waste stabilization ponds (WSP) have been widely used for sewage treatment in hot climate regions because they are economic and environmentally sustainable. In the present study a WSP complex comprising a primary facultative pond (PFP) followed by two maturation ponds (MP-1 and MP-2) was studied, in the city of Natal-RN. The main objective was to study the bio-degradability of organic matter through the determination of the kinetic constant k throughout the system. The work was carried out in two phases. In the first, the variability in BOD, COD and TOC concentrations and an analysis of the relations between these parameters, in the influent raw sewage, pond effluents and in specific areas inside the ponds was studied. In the second stage, the decay rate for organic matter (k) was determined throughout the system based on BOD tests on the influent sewage, pond effluents and water column samples taken from fixed locations within the ponds, using the mathematical methods of Least Squares and the Thomas equation. Subsequently k was estimated as a function of a hydrodynamic model determined from the dispersion number (d), using empirical methods and a Partial Hydrodynamic Evaluation (PHE), obtained from tracer studies in a section of the primary facultative pond corresponding to 10% of its total length. The concentrations of biodegradable organic matter, measured as BOD and COD, gradually reduced through the series of ponds, giving overall removal efficiencies of 71.95% for BOD and of 52.45% for COD. Determining the values for k, in the influent and effluent samples of the ponds using the mathematical method of Least Squares, gave the following values respectively: primary facultative pond (0,23 day-1 and 0,09 day-1), maturation 1 (0,04 day-1 and 0,03 day-1) and maturation 2 (0,03 day-1 and 0,08 day-1). When using the Thomas method, the values of k in the influents and effluents of the ponds were: primary facultative pond (0,17 day-1 and 0,07 day-1), maturation 1 (0,02 day-1 and 0,01 day-1) and maturation 2 (0,01 day-1 and 0,02 day-1). From the Partial Hydrodynamic Evaluation, in the first section of the facultative pond corresponding to 10% of its total length, it can be concluded from the dispersion number obtained of d = 0.04, that the hydraulic regime is one of dispersed flow with a kinetic constant value of 0.20 day-1

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The spatial variability of mechanical resistance to penetration (PR) and gravimetric moisture (GM) was studied at a depth of 0-0.40 m, in a ferralsol cropped with corn, and under conventional tillage in llha Solteira, Brazil (latitude 20 degrees 17'S, and longitude 52 degrees 25'W). The purpose of this study was to analyse and to try explaining the spatial variability of the mentioned soil physical properties using geostatistics. Soil data was collected at points arranged on the nodes of a mesh with 97 points. Geostatistics was used to analyse the spatial variability of PR and GM at four depths: 0-0. 1, 0.1-0.2, 0.2-0.3 and 0.3-0.4 m. PR showed a higher variability of data, with coefficients of variation of 52.39, 30.54, 16.91, and 15.18%, from the surface layers to the deepest layers. The values of the coefficients of variation for GM were lower: 9.99, 5.13, 5.59, and 5.69%. Correlation between GM and PR for the same soil layers was low. Penetration resistance showed spatial structure only in the 0.30-0.40 m layer, while gravimetric moisture showed spatial structure at all depths except for 0-0. 10 m. All the models of fitted semivariograms were spherical and exponential, with ranges of 10-80 m. Data for the variable 'GM' in the 0.20-0.30 and 0.30-0.40 m layers revealed a trend in data attributed to the occurrence of subsurface water flow. (C) 2005 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Hydrogeological prospecting in Northeast Brazil and in other crystalline terrains has been developed on the basis of structural and regional geology concepts that date back to the 50-60 decades and, as such, demand a natural re-evaluation and update. In this kind of terrain, the percolation and accumulation of ground water are controlled by fractures and other types of discontinuities, such as foliations and geological contacts that, through weathering, impart porosity and permeability to the rocks, allowing water flow and storage. Several factors should be considered in the process of locating water wells, as discussed in the literature. Among these, the kind of structures, fracture geometry (including aperture and connectivity) and their geological and chronological context. It is important to correlate fracture systems with the regional neotectonic framework. Fractures at low angle (sub parallel) with the principal stress axis (s1) are those which tend to open (actually they work as tension joints) and, in principle, would present major hydric potential; in the opposite side, fractures at high angle to s1 would behave as closed by a compressional component. Fractures diagonal to the compression and tension axes correspond to shear fractures and, due to their connectivity with second fractures, are also important in terms of hydric potential. Uplift followed by terrain denudation leads to decompression and a general tendency to open (aided by weathering processes) fractures and other rock discontinuities, at different orientations. Low angle fractures, formed in this context, are equally important to increase connectivity, collection of water and recharge of the aquifer systems. In a general way, an opening component (neotectonic or by terrain decompression) and several models to increase fracture connectivity correlate with a greater hydric potential of these structures. Together with parallel research, this thesis addresses models of ground water occurrence in crystalline terrains, either improving well established concepts like the (Riacho-Fenda model), but also stressing other possibilities, like the role of alluvium and paleo-regoliths (the Calha Elúvio-Aluvionar model) and of strongly altered, permo-porous zones placed at variable depths below the present surface, flanking several types of discontinuities, especially interconnected fracture arrays (the Bolsões de Intemperismo model). Different methodological approaches are also discussed in order to improve success rates in the location of water wells in crystalline terrains. In this methodological review, a number of case studies were selected in the eastern domain of the State of Rio Grande do Norte, involving the localities of Santa Cruz, Santo Antônio, Serrinha, Nova Cruz, Montanhas, Lagoa de Pedras and Lagoa Salgada. Besides the neotectonic analysis of brittle structures, this Thesis addresses the validation of remote sensing as a tool for ground water prospecting. Several techniques were tested in order to detect and select areas with higher potential for ground water accumulation, using Landsat 5-TM and RADARSAT images, besides conventional aerial photos. A number of filters were tested to emphasize lineaments in the images, improving their discrimination, to identify areas with higher overburden humidity, which could reflect subsurface water accumulation, as well as alluvium and other sedimentary covers that might act as recharge zones. The work started with a regional analysis with the orbital images, followed by analysis of aerial photos, up to a detailed structural study of rock exposures in the terrain. This last step involved the analysis of outcrops surrounding wells (in a ray of approximately 10 to 100 m) with distinct productivities, including dry examples. At the level required for detail, it was not possible to accomplish a statistical approach using the available well data catalogs, which lack the desired specific information. The methodology worked out in this Thesis must undergo a testing phase through location of new water wells. An increase in the success rates as desired will led to a further consolidation step with wider divulgation of the methodology to private companies and governmental agencies involved in ground water prospecting in crystalline terrains

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A new numerical methodology for thermal performance calculation in cross-flow heat exchangers is developed. Effectiveness-number of transfer units (epsilon-NTU) data for several standard and complex flow arrangements are obtained using this methodology. The results are validated through comparison with analytical solutions for one-pass cross-flow heat exchangers with one to four rows and with approximate series solution for an unmixed-unmixed heat exchanger, obtaining in all cases very small errors. New effectiveness data for some complex configurations are provided. (c) 2005 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The water produced by the Cristais River Drinking Water Treatment Plant (CR-DWTP) repeatedly produced mutagenic responses that could not be explained by the presence of disinfection byproducts (DBPs) generated by the reaction of humic acids and chlorine. In order to determine the possible role of chlorinated dye products in this mutagenic activity, solutions of a black dye commercial product (BDCP) composed of C. I. Disperse Blue 373, C. I. Disperse Orange 37, C. I. Disperse Violet 93, and chemically reduced BDCP (R-BDCP) were chlorinated in a manner similar to that used by the CR-DWTP. The resulting solutions were extracted with XAD-4 along with one drinking water sample collected from the CR-DWTP. All extracts showed mutagenic activity in the Salmonella/microsome assay. Dye components of the BDCP as well as its reduced chlorinated (Cl-R-BDCP) derivative were detected in the drinking water sample by analysis with a high performance liquid chromatography/diode array detector (HPLC/DAD). The mutagenicity results of these products suggest that they are, at least in part, accounting for the mutagenic activity detected in the drinking water samples from the Cristais River. The data obtained in this study have environmental and health implications because the chlorination of the BDCP and the R-BDCP leads to the formation of mutagenic compounds (Cl-BDCP and Cl-R-BDCP), which are potentially important disinfection byproducts that can contaminate the drinking water as well as the environment.