750 resultados para mechanical stiffness


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The dynamics of mechanical milling in a vibratory mill have been studied by means of mechanical vibration, shock measurements, computer simulation and microstructural evolution measurements. Two distinct modes of ball motion during milling, periodic and chaotic vibration, were observed. Mill operation in the regime of periodic vibration, in which each collision provides a constant energy input to milled powders, enabled a quantitative description of the effect of process parameters on system dynamics. An investigation of the effect of process parameters on microstructural development in an austenitic stainless steel showed that the impact force associated with collision events is an important process parameter for characterizing microstructural evolution. (C) 1997 Elsevier Science S.A.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This investigation focused on the finite element analyses of elastic and plastic properties of aluminium/alumina composite materials with ultrafine microstructure. The commonly used unit cell model was used to predict the elastic properties. By combining the unit cell model with an indentation model, coupled with experimental indentation measurements, the plastic properties of the composites and the associated strengthening mechanism within the metal matrix material were investigated. The grain size of the matrix material was found to be an important factor influencing the mechanical properties of the composites studied. (C) 1997 Elsevier Science S.A.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Prone position may delay the development of ventilator-induced lung injury (VILI), but the mechanisms require better elucidation. In experimental mild acute lung injury (ALI), arterial oxygen partial pressure (Pa(O2)), lung mechanics and histology, inflammatory markers [interleukin (IL)-6 and IL-1 beta], and type III procollagen (PCIII) mRNA expressions were analysed in supine and prone position. Wistar rats were randomly divided into two groups. In controls, saline was intraperitoneally injected while ALI was induced by paraquat. After 24-h, the animals were mechanically ventilated for 1-h in supine or prone positions. In ALI, prone position led to a better blood flow/tissue ratio both in ventral and dorsal regions and was associated with a more homogeneous distribution of alveolar aeration/tissue ratio reducing lung static elastance and viscoelastic pressure, and increasing end-expiratory lung volume and Pa(O2). PCIII expression was higher in the ventral than dorsal region in supine position, with no regional changes in inflammatory markers. In conclusion, prone position may protect the lungs against VILI, thus reducing pulmonary stress and strain. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: Uncertainties about the numerous degrees of freedom in ventilator settings leave many unanswered questions about the biophysical determinants of lung injury. We investigated whether mechanical ventilation with high air flow could yield lung mechanical stress even in normal animals. Design. Prospective, randomized, controlled experimental study. Setting: University research laboratory. Subjects. Thirty normal male Wistar rats (180-230 g). Interventions: Rats were ventilated for 2 hrs with tidal volume of 10 mL/kg and either with normal inspiratory air flow (V`) of 10 mL/s (F10) or high V` of 30 mL/s (F30). In the control group, animals did not undergo mechanical ventilation. Because high flow led to elevated respiratory rate (200 breaths/min) and airway peak inspiratory pressure (PIP,aw = 17 cm H2O), two additional groups were established to rule out the potential contribution of these variables: a) normal respiratory rate = 100 breaths/min and V` = 30 mL/sec; and b) PIP,aw = 17 cm H2O and V` 10 mL/sec. Measurements and Main Results: Lung mechanics and histology (light and electron microscopy), arterial blood gas analysis, and type III procollagen messenger RNA expression in lung tissue were analyzed. Ultrastructural microscopy was similar in control and F10 groups. High air flow led to increased lung plateau and peak pressures, hypoxemia, alveolar hyperinflation and collapse, pulmonary neutrophilic infiltration, and augmented type III procollagen messenger RNA expression compared with control rats. The reduction of respiratory rate did not modify the morphofunctional behavior observed in the presence of increased air flow. Even though the increase in peak pressure yielded mechanical and histologic changes, type III procollagen messenger RNA expression remained unaltered. Conclusions: Ventilation with high inspiratory air flow may lead to high tensile and shear stresses resulting in lung functional and morphologic compromise and elevation of type III procollagen messenger RNA expression.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND The impact of increased central arterial stiffness as a predictor of morbidity and mortality, independently of other cardiovascular (CV) risk factors, has been established. The main aim of the present work was to investigate the association of ethnicity on arterial stiffness in different ethnic groups from the Brazilian population. METHODS A total of 1,427 individuals from the general population were randomly selected from the Vitoria City metropolitan area and 588 Amerindians from a native community in Brazil. The ethnicity of the general population was classified by a standard questionnaire as Caucasian descent, African descent, or Mulattos (considered racially mixed subjects). Pulse wave velocity (PWV) was measured with a noninvasive automatic device (Complior, Colson; Garges les Gonesses, France). RESULTS Hemodynamic data of PWV, systolic blood pressure (SBP), diastolic blood pressure (DBP), and mean blood pressure (MBP) was higher in African descent individuals than in the other groups (P < 0.001). These results were still observed after adjustment for age and mean arterial pressure (P < 0.001). In addition, studying only normotensive individuals, PWV adjusted levels were higher in African descent individuals, and lower in Amerindians when compared with other ethnic groups (P < 0.01), showing, without the possible confounder effects of time and severity of hypertension or medication use, that PWV is associated with ethnicity in our population. CONCLUSION The study of different ethnic groups from a highly admixtured population was able to demonstrate an association between ethnicity and arterial stiffness.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To evaluate the effects of different mechanical ventilation (MV) strategies on the mucociliary system. Experimental study. Twenty-seven male New Zealand rabbits. After anesthesia, animals were tracheotomized and ventilated with standard ventilation [tidal volume (Vt) 8 ml/kg, positive end expiratory pressure (PEEP) 5 cmH(2)O, flow 3 L/min, FiO(2) 0.4] for 30 min. Next, animals were randomized into three groups and ventilated for 3 h with low volume (LV): Vt 8 ml/kg, PEEP 5 cmH(2)O, flow 3 L/min (n = 6); high volume (HV): Vt 16 ml/kg, PEEP 5 cmH(2)O, flow 5 L/min (n = 7); or high pressure (HP): Ppeak 30 cmH(2)O, PEEP 12 cmH(2)O (n = 8). Six animals (controls) were ventilated for 10 min with standard ventilation. Vital signals, blood lactate, and respiratory system mechanics were verified. Tracheal tissue was collected before and after MV. Lung and tracheal tissue sections were stained to analyze inflammation and mucosubstances by the point-counting method. Electron microscopy verified tracheal cell ultrastructure. In situ tracheal ciliary beating frequency (CBF), determined using a videoscopic technique, and tracheal mucociliary transport (TMCT), assessed by stereoscopic microscope, were evaluated before and after MV. Respiratory compliance decreased in the HP group. The HV and HP groups showed higher lactate levels after MV. Macroscopy showed areas of atelectasis and congestion on HV and HP lungs. Lung inflammatory infiltrate increased in all ventilated groups. Compared to the control, ventilated animals also showed a reduction of total and acid mucus on tracheal epithelium. Under electron microscopy, injury was observed in the ciliated cells of the HP group. CBF decreased significantly after MV only in the HP group. TMCT did not change significantly in the ventilated groups. Different MV strategies induce not only distal lung alterations but also morphological and physiological tracheal alterations leading to mucociliary system dysfunction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Cardiovascular diseases (CVD) are the main cause of death and disability in developed countries. In most cases, the progress of CVD is influenced by environmental factors and multifactorial inheritance. The purpose of this study was to investigate the association between APOE genotypes, cardiovascular risk factors, and a noninvasive measure of arterial stiffness in the Brazilian population. Methods: A total of 1493 urban Brazilian individuals were randomly selected from the general population of the Vitoria City Metropolitan area. Genetic analysis of the APOE polymorphism was conducted by PCR-RFLP and pulse wave velocity analyzed with a noninvasive automatic device. Results: Age, gender, body mass index, triglycerides, creatinine, uric acid, blood glucose, blood pressure phenotypes were no different between epsilon 2, epsilon 3 and epsilon 4 alleles. The epsilon 4 allele was associated with higher total-cholesterol (p < 0.001), LDL-C (p < 0.001), total-cholesterol/HDL-C ratio (p < 0.001), LDL/HDL-C ratio (p < 0.001), lower HDL-C values (p < 0.001) and higher risk to obesity (OR = 1.358, 95% CI = 1.019-1.811) and hyperuricemia (OR = 1.748, 95% CI = 1.170-2.611). Nevertheless, pulse wave velocity (p = 0.66) measures were no different between genotypes. The significant association between APOE genotypes and lipid levels persisted after a 5-year follow-up interval, but no interaction between time and genotype was observed for lipids longitudinal behavior. Conclusion: The epsilon 4 allele of the APOE gene is associated with a worse lipid profile in the Brazilian urban population. In our relatively young sample, the observed effect of APOE genotype on lipid levels was not translated into significant effects in arterial wall stiffness.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Obstructive sleep apnea (OSA) is an established cause of hypertension However, it is not clear whether the frequency of masked hypertension in patients with OSA and whether OSA have an independent role on arterial stiffness taking into account ambulatory blood pressure (BP) monitoring (ABPM) METHODS We evaluated 61 male normotensive participants as determined by casual clinic BP level <140/90 mm Hg without clinical evidence of cardiovascular disease and on no medications (43 patients with moderate-to-severe OSA (apnea-hypopnea index (AHI) >= 15 events/hour by polysomnography) and 18 age- and body mass index-matched controls without OSA (AHl <5 events/hour)) Pulse wave velocity (PWV), an index of arterial stiffness, and 24-h ABPM were performed in a blinded fashion Masked hypertension was defined when abnormal daytime ABPM was >= 135 or >= 85 mm Hg RESULTS The AHI and lowest oxygen saturation were 26 +/- 16 and 90 +/- 2 vs 528 +/- 210 events/hour and 75 +/- 10% for controls and OSA patients, respectively, P < 0 001. Compared with controls, patients with OSA had higher office systolic BP (113 +/- 9 vs 118 +/- 10 mm Hg, P=0 05) and a higher unadjusted proportion of masked hypertension (2 controls (11.1%)vs 13 patients (30 2%), P < 005) PWV was 87 +/- 0.7, 9.4 +/- 1.0, and 10.6 +/- 1.1 m/s in the control, OSA without and with masked hypertension groups, respectively (P < 0 01 for each comparison) Multiple regression showed that systolic daytime ABPM and the lowest oxygen saturation were independently related to PWV (adjusted R(2) = 0 34, P < 0 01) CONCLUSIONS Patients with OSA presented a higher unadjusted rate of masked hypertension than matched controls. Lowest oxygen saturation has an independent association with arterial stiffness

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To compare mechanical and ethanol epithelial removal with respect to myofibroblast development and haze formation after photorefractive keratectomy (PRK). METHODS: Seventeen rabbits underwent mechanical or ethanol debridement, and the opposite eye of each rabbit served as an unwounded control. In both groups, the epithelium was removed with a spatula and discarded. A -9.00-diopter PRK was performed in each eye. The level of haze in each cornea at 4 weeks was graded at the slit-lamp microscope according to the Fantes scale. Myofibroblast generation was detected with immunocytochemistry for alpha-smooth muscle actin (alpha-SMA) and cells were quantitatively analyzed. RESULTS: No difference was noted between the two groups in alpha-SMA + myofibroblasts 4 weeks after surgery (43.6 +/- 2.0/400X field and 45.7 +/- 4.8/400X field in ethanol and mechanical groups, respectively) (P=.10). A slight difference was noted but did not reach statistical significance with regard to stromal haze between ethanol and mechanical groups (2.0 +/- 0.5 and 2.3 +/- 0.4, respectively, P=.063). The ethanol and mechanical groups were statistically different when compared to controls regarding stromal haze and alpha-SMA+ cells (P <.0001 for all comparisons). CONCLUSIONS:No difference was noted in clinical haze or myofibroblast generation between corneas that had PRK with mechanical,or ethanol epithelial debridement. [J Refract Surg., 2008;24:923-927.]

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To compare the triggering performance of mid-level ICU mechanical ventilators with a standard ICU mechanical ventilator. Design: Experimental bench study. Setting: The respiratory care laboratory of a university-affiliated teaching hospital. Subject: A computerized mechanical lung model, the IngMar ASL5000. Interventions: Ten mid-level ICU ventilators were compared to an ICU ventilator at two levels of lung model effort, three combinations of respiratory mechanics (normal, COPD and ARDS) and two modes of ventilation, volume and pressure assist/control. A total of 12 conditions were compared. Measurements and main results: Performance varied widely among ventilators. Mean inspiratory trigger time was < 100 ms for only half of the tested ventilators. The mean inspiratory delay time (time from initiation of the breath to return of airway pressure to baseline) was longer than that for the ICU ventilator for all tested ventilators except one. The pressure drop during triggering (Ptrig) was comparable with that of the ICU ventilator for only two ventilators. Expiratory Settling Time (time for pressure to return to baseline) had the greatest variability among ventilators. Conclusions: Triggering differences among these mid-level ICU ventilators and with the ICU ventilator were identified. Some of these ventilators had a much poorer triggering response with high inspiratory effort than the ICU ventilator. These ventilators do not perform as well as ICU ventilators in patients with high ventilatory demand.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives. The aim of this study was to evaluate the effect of thermal and mechanical cycling alone or in combination, on the flexural strength of ceramic and metallic frameworks cast in gold alloy or titanium. Methods. Metallic frameworks (25 mm x 3 mm x 0.5 mm) (N = 96) cast in gold alloy or commercial pure titanium (Ti cp) were obtained using acrylic templates. They were airborne particle-abraded with 150 mu m aluminum oxide at the central area of the frameworks (8 mm x 3 mm). Bonding agent and opaque were applied on the particle-abraded surfaces and the corresponding ceramic for each metal was fired onto them. The thickness of the ceramic layer was standardized by positioning the frameworks in a metallic template (height: I mm). The specimens from each ceramic-metal combination (N = 96, n = 12 per group) were randomly assigned into four experimental fatigue conditions, namely water storage at 37 degrees C for 24 h (control group), thermal cycling (3000 cycles, between 4 and 55 degrees C, dwell time: 10 s), mechanical cycling (20,000 cycles under 10 N load, immersion in distilled water at 37 degrees C) and, thermal and mechanical cycling. A flexural strength test was performed in a universal testing machine (crosshead speed: 1.5 mm/min). Data were statistically analyzed using two-way ANOVA and Tukey`s test (alpha = 0.05). Results. The mean flexural strength values for the ceramic-gold alloy combination (55 +/- 7.2MPa) were significantly higher than those of the ceramic-Ti cp combination (32 +/- 6.7 MPa) regardless of the fatigue conditions performed (p < 0.05). Mechanical and thermo-mechanical fatigue decreased the flexural strength results significantly for both ceramic-gold alloy (52 +/- 6.6 and 53 +/- 5.6 MPa, respectively) and ceramic-Ti cp combinations (29 +/- 6.8 and 29 +/- 6.8 MPa, respectively) compared to the control group (58 +/- 7.8 and 39 SA MPa, for gold and Ti cp, respectively) (p < 0.05) (Tukey`s test). While ceramic-Ti cp combinations failed adhesively at the metal-opaque interface, gold alloy frameworks exhibited a residue of ceramic material on the surface in all experimental groups. Significance. Mechanical and thermo-mechanical fatigue conditions decreased the flexural strength values for both ceramic-gold alloy and ceramic-Ti cp combinations with the results being significantly lower for the latter in all experimental conditions. (C) 2007 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Methods We analyzed the influence of conjugated equine estrogen (CEE) and raloxifene on arterial stiffness. Sixty-seven healthy, normotensive women 1-10 years into menopause were assigned to receive oral placebo, conjugated equine estrogen 0.625mg, or raloxifene 60mg. Arterial stiffness was evaluated by measuring the carotid-femoral and femoral-dorsalis pedis pulse wave velocity (CF PWV, FP PWV). Systolic pressure augmentation index (AI) at the carotid artery was obtained with applanation tonometry. Results Arterial stiffness was not affected by any treatment regimen: placebo (CF PWV before vs. after: 644 vs. 626 cm/s, p = 0.09; FP PWV before vs. after: 1006 vs. 1012 cm/s, p = 0.77; AI before vs. after = 30 vs. 29%, p = 0.55), CEE (CF PWV before vs. after: 642 vs. 600 cm/s, p = 0.11; FP PWV before vs. after: 952 vs. 971 cm/s, p = 0.66; AI before vs. after: 25 vs. 32%, p = 0.82), and raloxifene (CF PWV before vs. after: 636 vs. 601 cm/s, p = 0.12; FP PWV before vs. after: 964 vs. 941 cm/s, p = 0.62; AI before vs. after: 25 vs. 25%, p = 0.65). A correlation occurred between basal stiffness and the degree of reduction in indexes measured, indicating that the higher the basal stiffness, the greater the degree of reduction, particularly in the CEE group: CF PWV (r = -0.602, p = 0.001); FP PWV (r = -0.455, p = 0.022); AI (r = -0.410, p = 0.042). Conclusions Conjugated equine estrogen and raloxifene do not seem to affect arterial stiffness of healthy normotensive women less than 10 years since menopause. Reduction in arterial stiffness seems related to its basal level.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We assess the effects of chemical processing, ethylene oxide sterilization, and threading on bone surface and mechanical properties of bovine undecalcified bone screws. In addition, we evaluate the possibility of manufacturing bone screws with predefined dimensions. Scanning electronic microscopic images show that chemical processing and ethylene oxide treatment causes collagen fiber amalgamation on the bone surface. Processed screws hold higher ultimate loads under bending and torsion than the in natura bone group, with no change in pull-out strength between groups. Threading significantly reduces deformation and bone strength under torsion. Metrological data demonstrate the possibility of manufacturing bone screws with standardized dimensions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Because of the scarcity of information about the comparison of training to sedentarism beforehand immobilization and rehabilitation through muscle mechanical properties, the present work investigates this theme. Seventy rats were divided into 7 groups: 1-control (C); 2-trained (T); 3-sedentary (S); 4-trained and immobilized (TI); 5-sedentary and immobilized (SI); 6-trained, immobilized and rehabilitated (TIR); 7-sedentary, immobilized and rehabilitated (SIR). Interventions: Swimming training; Sedentarism (reduced size cages); Cast immobilization (pelvic limb) and water rehabilitation. Load at the limit of proportionality (LLP), maximum limit load (MLL) and stiffness (St) were the mechanical properties determined after a mechanical test of traction of the gastrocnemius. The training improved all mechanical properties when compared to sedentarism. After immobilization, LLP and MLL were reduced in TI and SI. However, there was no difference in St between C and TI. Additionally, TI showed improved MLL when compared to SI. The comparison of TI and TIR showed significant melioration in all properties after remobilization. SIR showed an improvement only in MLL when compared to SI. Significant melioration in LLP and St was observed in TIR compared to SIR. We demonstrated that the training before immobilization and rehabilitation had a positive effect on the muscle mechanical behavior compared to sedentarism. This analysis is of fundamental importance because it helps characterize the muscle tissue under different functional demands.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background. A variety of techniques can be used to achieve stabilization of femoral valgus osteotomies in children, but what is lacking is a versatile fixation system that associates stability and versatility at different ages and for different degrees of deformity. Methods. Mechanical tests of three configurations used to fix femoral valgus osteotomies, based oil the tension band wire principle, were carried out. A 30 degrees wedge valgus osteotomy was performed at the subtrochanteric level in 60 swine femurs and fixed with three different systems. In Group 1, two Kirschner wires (K wire) were introduced from the tip of the greater trochanter to the medial cortex, crossing the osteotomy. A flexible steel wire was anchored to the K wires into holes in the lateral cortex and tightened to form a tension band. The same setup was used in Group 2, but two additional smooth K wires were inserted into the lateral surface of the greater trochanter and driven to the femoral head with the distal extremities bent and tied around tile bone shaft. In Group 3, the fixation was similar to that in Group 2, but tile ascending K wires were introduced below the osteotomy level, crossing the osteotonly. Mechanical tests in bending-compression and torsion were used to access the stability. Findings. The torsional relative stiffness was 116% greater for Group 3 (0.27 N m/degree) and no significant difference was found between Group 1 (0.10 N m/degree) and Group 2 (0.12 N m/degree). The average torque was 103% higher for Group 3 (1.86 N m). Stiffness in bending-compression was significantly higher in Group 3 (508 x 10(3) N/m) than in Group 1 (211 x 10(3) N/m) and Group 2 (219 x 10(3) N/m). Interpretation. Fixation as used in Group 3 was significantly more stable, both in torsion and bending-compression tests, than tile other two techniques. (c) 2007 Elsevier Ltd. All rights reserved.