973 resultados para inter-agency collaboration


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Oncologic outcomes in men with radiation-recurrent prostate cancer (PCa) treated with salvage radical prostatectomy (SRP) are poorly defined. Objective: To identify predictors of biochemical recurrence (BCR), metastasis, and death following SRP to help select patients who may benefit from SRP. Design, setting, and participants: This is a retrospective, international, multi-institutional cohort analysis. There was amedian follow-up of 4.4 yr following SRP performed on 404 men with radiation-recurrent PCa from 1985 to 2009 in tertiary centers. Intervention: Open SRP. Measurements: BCR after SRP was defined as a serum prostate-specific antigen (PSA) >= 0.1 or >= 0.2 ng/ml (depending on the institution). Secondary end points included progression to metastasis and cancerspecific death. Results and limitations: Median age at SRP was 65 yr of age, and median pre-SRP PSA was 4.5 ng/ml. Following SRP, 195 patients experienced BCR, 64 developed metastases, and 40 died from PCa. At 10 yr after SRP, BCR-free survival, metastasis-free survival, and cancer-specific survival (CSS) probabilities were 37% (95% confidence interval [CI], 31-43), 77% (95% CI, 71-82), and 83% (95% CI, 76-88), respectively. On preoperative multivariable analysis, pre-SRP PSA and Gleason score at postradiation prostate biopsy predicted BCR (p = 0.022; global p < 0.001) and metastasis (p = 0.022; global p < 0.001). On postoperative multivariable analysis, pre-SRP PSA and pathologic Gleason score at SRP predicted BCR (p = 0.014; global p < 0.001) and metastasis (p < 0.001; global p < 0.001). Lymph node involvement (LNI) also predicted metastasis (p = 0.017). The main limitations of this study are its retrospective design and the follow-up period. Conclusions: In a select group of patients who underwent SRP for radiation-recurrent PCa, freedom from clinical metastasis was observed in > 75% of patients 10 yr after surgery. Patients with lower pre-SRP PSA levels and lower postradiation prostate biopsy Gleason score have the highest probability of cure from SRP. (C) 2011 European Association of Urology. Published by Elsevier B. V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim was to investigate inter-tester and intra-tester reliability and parallel reliability between a visual assessment method and a method using a pachymeter for locating the mid-point of the patella in determining the medial/lateral patella orientation. Fifteen asymptomatic subjects were assessed and the mid-point of the patella was determined by both methods on two separate occasions two weeks apart. Inter-tester reliability was obtained by ANOVA and by intraclass correlation coefficient (ICC); intra-tester reliability was obtained by a paired t-test and ICC; and parallel reliability was obtained by Pearson`s Correlation and ICC, for the measurement on the first and second evaluations. There was acceptable inter-tester agreement (p = 0.490) and reliability for the visual inspection (ICC = 0.747) and for the pachymeter (ICC = 0.716) at the second evaluation. The inter-tester reliability in the first evaluation was unacceptable (visual ICC = 0.604; pachymeter ICC = 0.612). Although there was statistical similarity between measurements for the first and second evaluations for all testers, intra-tester reliability was not acceptable for both methods: visual (examiner 1 ICC = 0.175; examiner 2 ICC = 0.189; examiner 3 ICC = 0.155) and pachymeter (examiner 1 ICC = 0.214; examiner 2 ICC = 0.246; examiner 3 ICC = 0.069). Parallel reliability gave a perfect correlation at the first evaluation (r=0.828; p<0.001) and at the second (r=0.756; p<0.001) and reliability was between acceptable and very good (ICC = [0.748-0.813]). Both visual and pachymeter methods provide reliable and similar medial/lateral patella orientation and are reliable between different examiners, but the results between the two assessments at 2 weeks` interval demonstrated an unacceptable reliability. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Intervertebral cervical disc herniation (CDH) is a relatively common disorder that can coexist with degenerative changes to worsen cervicogenic myelopathy. Despite the frequent disc abnormalities found in asymptomatic populations, magnetic resonance imaging (MRI) is considered excellent at detecting cervical spine myelopathy (CSM) associated with disc abnormality. The objective of this study was to investigate the intra- and inter-observer reliability of MRI detection of CSM in subjects who also had co-existing intervertebral disc abnormalities. Materials and methods: Seven experienced radiologists reviewed twice the MRI of 10 patients with clinically and/or imaging determined myelopathy. MRI assessment was performed individually, with and without operational guidelines. A Fleiss Kappa statistic was used to evaluate the intra- and inter-observer agreement. Results: The study found high intra-observer percent agreement but relatively low Kappa values on selected variables. Inter-observer reliability was also low and neither observation was improved with operational guidelines. We believe that those low values may be associated with the base rate problem of Kappa. Conclusion: In conclusion, this study demonstrated high intra-observer percent agreement in MR examination for intervertebral disc abnormalities in patients with underlying cervical myelopathy, but differing levels of intra- and inter-observer Kappa agreement among seven radiologists. (c) 2007 Elsevier Ireland Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present study aimed to assess the reliability of intra and inter-examiner subacromial impingement index (SII) measures obtained from radiographs. Thirty-six individuals were enrolled and divided into two groups: control group, composed of 18 volunteers in good general health without shoulder problems, and a group of 18 patients with subacromial impingement syndrome (SIS). Radiographic images were taken with the dominant upper limb in neutral rotation, while the volunteers held their arm at 90A degrees of abduction in the frontal plane. The beam of radiation at 30A degrees craniocaudal inclination was used to provide an antero-posterior image view. Three blinded examiners each performed three measurements from the subacromial space (SS) and the anatomical neck of the humerus (NH). The SII was calculated as the ratio of the SS and the NH measures. The mean values of SII were compared using t-tests. The intra-class correlation coefficient (ICC) was used to assess intra- and inter-examiner reliability of the measures. The mean values of SII were greater for the control group (0.12) than for the SIS group (0.08; p = 0.0071). SII measurements showed excellent intra (0.96-0.99) and inter-examiner reliability (0.94) for both the control and SIS group. The results of this study show the potential use of the SII; a greater mean value for the control group compared to the SIS group and excellent reliability for intra- and inter-examiner measurement. Validation studies of the index should be conducted to correlate the index with clinical findings from subacromial impingement syndrome.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This essay recognises the power of reading and intertextuality (embedding texts within texts) in fiction targeted at girls and young women.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective To evaluate the inter-rater reliability of the modified Oxford Grading Scale and the Peritron manometer. Design All participants were evaluated twice, first by one examiner and 30 days later by a second examiner. Measurements of vaginal squeeze pressure were compared with the results from the palpation test. Participants Nineteen women with a mean age of 23.7 years (range 21 to 28 years). Results Inter-rater reliability for vaginal palpation was fair (kappa = 0.33, 95% confidence interval 0.09 to 0.57). Using the Peritron manometer, the difference between examiners was less than 10 cmH(2)O in 11 of the 19 (58%) cases. The palpation test did not differentiate between weak, moderate, good and strong muscle contractions. This study found fair inter-rater reliability for the modified Oxford Grading Scale and moderate inter-rater reliability for the Peritron manometer. Conclusions The inter-rater reliability of vaginal squeeze pressure measurement using the Peritron manometer is acceptable and can be used in re-evaluations performed by different examiners in clinical practice. However, for research purposes, the ideal situation would be for a single examiner to assess and re-assess the subject. Vaginal palpation is important in the clinical assessment of correctness of a pelvic floor muscle contraction, but this study does not support the use of the modified Oxford Grading Scale as a reliable and valid method to measure and differentiate pelvic floor muscle strength. (C) 2010 Chartered Society of Physiotherapy. Published by Elsevier Ltd. All rights reserved.