967 resultados para flow-through cell


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Molecular imprinting is a useful technique for the preparation of functional materials with molecular recognition properties. A Biomimetic Sensor Potentiometric System was developed for assessment of doxycycline (DOX) antibiotic. The molecularly imprinted polymer (MIP) was synthesized by using doxycycline as a template molecule, methacrylic acid (MAA) and/or acrylamide (AA) as a functional monomer and ethylene glycol dimethacrylat (EGDMA) as a cross-linking agent. The sensing elements were fabricated by the inclusion of DOX imprinted polymers in polyvinyl chloride (PVC) matrix. The sensors showed a high selectivity and a sensitive response to the template in aqueous system. Electrochemical evaluation of these sensors under static (batch) mode of operation reveals near-Nernstian response. MIP/MAA membrane sensor was incorporated in flow-through cells and used as detectors for flow injection analysis (FIA) of DOX. The method has the requisite accuracy, sensitivity and precision to assay DOX in tablets and biological fluids.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para obtenção do Grau de Mestre em Energias Renováveis – Conversão Eléctrica e Utilização Sustentáveis

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Abstract: INTRODUCTION: To provide information for cervical cancer screening and vaccination in Henan province, China, the distribution of human papillomavirus (HPV) was analyzed. METHODS: The HPV genotypes were detected using gene array and flow-through hybridization. RESULTS: Overall, 38.1% (1,536/4,033) of the women were human papillomavirus deoxyribonucleic acid (HPV DNA) positive. The prevalence of high-risk HPV types was 32.4%. HPV 16 was the most prevalent genotype (8.9%), followed by HPV 52 (5.8%) and HPV 58 (4.4%). CONCLUSIONS: The data support close surveillance of women for cervical cancer screening, and HPV prophylactic vaccines including HPV16, HPV 52, and HPV 58 might offer greater protection in this area.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Dissertação de mestrado integrado em Engenharia de Materiais

Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJECTIVE: To assess the feasibility and safety of coronary interventions performed through the radial artery. METHODS: We studied 103 patients with ages from 38 to 86 years (57±8.7), 90 (87%) males, and: radial pulse with a good amplitude, presence of ulnar pulse, a good collateral flow through the palmar arch assessed with the Allen's test. RESULTS: The vascular approach was obtained in 97 (94%) patients, 88 (91%) treated electively and 9 (9%) during acute myocardial infarction, for primary angioplasty; 56 (64%) unstable angina; 22 (25%) stable angina; 10 (11%) were asymptomatic, 6 referred for recanalization of chronic occlusion and 4 silent ischemia in the first week after acute myocardial infarction. We approached 107 arteries: anterior descending artery, 49 (46%); right coronary artery, 27 (25%); circumflex artery, 25 (23%); diagonal artery, 6 (6%); and 2 saphenous vein bypass grafts. We treated 129 lesions: 80 (62%) B2 type; 23 (18%) B1 type; 17 (13%) C type; and 9 (7%). A type. There were 70 stents , and 59 balloon angioplasties performed. Thirty-two (33%) patients used GP IIb/IIIa inhibitors. The mean duration of the elective procedure was 42.3±12.8 min. Success, correct stent deployment and residual lesion <20%, was reached in 100% of the lesions treated with stent implantation; arterial dilation with residual lesion <50% was obtained in 96% of the lesions treated with transluminal coronary angioplasty (TCA). Complications, were: 1 (1.0%) non-Q-wave acute myocardial infarction; 2 (2%) hematomas in the forearm; and 2 losses of radial pulse. CONCLUSION: Radial artery aproach is practical and safe for percutaneous coronary interventions there was a low incidence of complications.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

An algebraic decay rate is derived which bounds the time required for velocities to equilibrate in a spatially homogeneous flow-through model representing the continuum limit of a gas of particles interacting through slightly inelastic collisions. This rate is obtained by reformulating the dynamical problem as the gradient flow of a convex energy on an infinite-dimensional manifold. An abstract theory is developed for gradient flows in length spaces, which shows how degenerate convexity (or even non-convexity) | if uniformly controlled | will quantify contractivity (limit expansivity) of the flow.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Developing a predictive understanding of subsurface flow and transport is complicated by the disparity of scales across which controlling hydrological properties and processes span. Conventional techniques for characterizing hydrogeological properties (such as pumping, slug, and flowmeter tests) typically rely on borehole access to the subsurface. Because their spatial extent is commonly limited to the vicinity near the wellbores, these methods often cannot provide sufficient information to describe key controls on subsurface flow and transport. The field of hydrogeophysics has evolved in recent years to explore the potential that geophysical methods hold for improving the quantification of subsurface properties and processes relevant for hydrological investigations. This chapter is intended to familiarize hydrogeologists and water-resource professionals with the state of the art as well as existing challenges associated with hydrogeophysics. We provide a review of the key components of hydrogeophysical studies, which include: geophysical methods commonly used for shallow subsurface characterization; petrophysical relationships used to link the geophysical properties to hydrological properties and state variables; and estimation or inversion methods used to integrate hydrological and geophysical measurements in a consistent manner. We demonstrate the use of these different geophysical methods, petrophysical relationships, and estimation approaches through several field-scale case studies. Among other applications, the case studies illustrate the use of hydrogeophysical approaches to quantify subsurface architecture that influence flow (such as hydrostratigraphy and preferential pathways); delineate anomalous subsurface fluid bodies (such as contaminant plumes); monitor hydrological processes (such as infiltration, freshwater-seawater interface dynamics, and flow through fractures); and estimate hydrological properties (such as hydraulic conductivity) and state variables (such as water content). The case studies have been chosen to illustrate how hydrogeophysical approaches can yield insights about complex subsurface hydrological processes, provide input that improves flow and transport predictions, and provide quantitative information over field-relevant spatial scales. The chapter concludes by describing existing hydrogeophysical challenges and associated research needs. In particular, we identify the area of quantitative watershed hydrogeophysics as a frontier area, where significant effort is required to advance the estimation of hydrological properties and processes (and their uncertainties) over spatial scales relevant to the management of water resources and contaminants.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Durant el període de gaudiment de la beca, des del dia 9 de març del 2007 fins el dia 8 de març del 2010, s’han dut a terme diferents tipus d’experiments amb sistemes bidimensionals com són les monocapes de Langmuir. Inicialment es va començar per l’estudi i la caracterització d’aquests sistemes experimentals, tant en repòs com en dinàmic, com és l’estudi de la reposta col•lectiva molecular de dominis d’un azoderivat fotosensible al rotar el pla de polarització mentre es mante sota il•luminació constant i els estudis de sistemes bidimensionals al collapse que es poden relacionar a les propietats viscoplàstiques dels sòlids. Una altra via d’estudi és la reologia d’aquests sistemes bidimensionals quan flueixen a través de canals. Arrel del sistema experimental més simple, una monocapa fluint per un canal, s’ha observat i estudiat l’efecte coll d’ampolla. Un cop assolit i estudiat el sistema més senzill, s’han aplicat tècniques més complexes de fabricació per fotolitografia per fer fluir monocapes de Langmuir per circuits on hi ha un gran contrast de mullat. Un cop aquests circuits es van implementar satisfactòriament en un sistema pel control de fluxos bidimensionals, es posen de manifest les possibles aplicacions futures d’aquests sistemes per l’estudi i el desenvolupament de la microfluídica bidimensional.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

We present here an atypical finding during an elective repeat cesarean section. Despite urine flow through an indwelling bladder catheter, bladder remains distended during the whole procedure. Unexpected anatomical variations and malformations can make routine surgery challenging. Urinary tract anomalies should be suspected in cases of unexpected difficult bladder catheterization.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Background and aim: Neuropathic pain (NP) is a frequent and disabling disorder occurring as a consequence of a direct lesion of the nervous system and recurrently associated with a positive shift toward nervous system excitability. Peripheral nerve activity is mainly carried by voltage-gated sodium channels (VGSC), with Nav1.7 isoform being an important candidate since loss of function mutations of its gene is associated with congenital inability to experience pain. Interestingly, ubiquitin ligases from the Nedd4 family are well known proteins that regulate the turnover of many membrane proteins such as VGSC and we showed Nedd2-2 is downregualted in experimental models of chronic pain. The aim of this study was to investigate the importance of Nedd4-2 in the modulation of Nav1.7 at the membrane. Methods: In vitro: whole cell patch clamp on HEK293 cell line stably expressing Nav1.7 was used to record sodium currents (INa), where the peak current of INa reflects the quantity of functional Nav1.7 expressed at the membrane. The possibility that Nedd4-2 modulates the currents was assessed by investigating the effect of its cotransfection on INa. Biotinylation of cell surface was used to isolate membrane-targeted Nav1.7. Furthermore, as the interaction between Nedd4-2 and Nav isoforms was previously reported to rely on an xPPxYx sequence (PY-motif), we mutated this latter to study its impact in the specific interaction between Nav1.7 and Nedd4-2. GST-fusion proteins composed of the Nav1.7 c terminal 66 amino acids (wild-type or PY mutated) and GST were used to pull-down Nedd4-2 from lysates. Results: Co-transfection of Nav1.7 with Nedd4-2 reduced the Nav1.7 current amplitude by ~80% (n = 36, p <0.001), without modifying the biophysical properties of INa. In addition, we show that the quantity of Nav1.7 at the membrane was decreased when Nedd4-2 was present. This effect was dependent on the PY-motif since mutations in this sequence abolished the down-regulatory effect of Nedd4-2. The importance of this motif was further confirmed by pull down experiments since the PY mutant completely eliminate the interaction with Nedd4-2. Perspectives: Altogether, these results point to the importance of Nedd4-2 as a Nav1.7 regulator through cell surface modulation of this sodium channel. Further experiments in freshly dissociated neurons from wild type and Scn1bflox/Nedd4-2Cre mice are needed to confirm in vivo these preliminary data.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Introduction: Nasal continuous positive airways pressure (n-CPAP) is an effective treatment in premature infants with respiratory distress. The cardio-pulmonary interactions secondary to n-CPAP are well studied in adults, but less well described in premature infants. We postulated that there could be important interactions with regard to the patent ductus arteriosus (PDA). Methods: Prospective study, approved by the local ethic committee. Premature infants less than 32 weeks gestation, _7 days-old, needing n-CPAP for respiratory distress, but without the need of additional oxygen were included in the study. Every patient had a first echocardiography with n-CPAP and then n-CPAP was retrieved. 3 hours later the echocardiography was repeated by the same investigator and then the patient replaced on n-CPAP. Results: 14 premature newborn were included, mean gestational age of 28 _ 2 weeks, mean weight 1.1 _ 0.3 Kg and height 39 _ 3 cm. Echocardiographic measurements are depicted in Table 1. Significant finding were observed between measurement on n- CPAP or without n-CPAP: on end diastolic left ventricular diameter (12.8 _ 1.6 mm vs. 13.5 _ 2 mm), on end systolic left ventricular diameter (8.4 _ 1.3 mm vs. 9.1 _ 1.5 mm), left atrium diameter (8.9 _ 2.2 mm vs. 10.4 _ 2.5 mm), maximal velocity on tricuspid valve (46 _ 10 cm/s vs. 51 _ 9 cm/s), calculated Qp (3.7 _ 0.8 L/min/m2 vs. 4.3 _ 0.8 L/min/m2). Only three patients have demonstrated a PDA during the study. Conclusion: Positive end expiratory pressure (Peep) has hemodynamic effects which are: reduction of systemic and pulmonary venous return as shown by the changes on tricuspid valve inflow,on the calculated Qp and finally on the diameter of the left atrium and left ventricle.We found in premature infants the same hemodynamic effects than those described in adults but with lower Peep values. This could be due to the particular elasticity and weakness of the thoracic wall of premature infants. Interestingly the flow through a PDA seems also to be diminished with Peep, but the number of patients is insufficient to conclude. Further investigation will be needed to better understand these interactions. Table 1. Echocardiographic measurement (mean (SD)). With n-CPAP Without n-CPAP p value RV ED diameter (mm) 6.3 (1.7) 6.04 (1.1) NS LV ED diameter (mm) 12.8 (1.6) 13.5 (2.0) _0.05 LV ES diameter (mm) 8.4 (1.3) 9.1 (1.5) _0.05 SF (%) 34 (5) 33 (6) NS Ao valve diameter (mm) 7.4 (1.3) 7.4 (1.2) NS LA diameter (mm) 8.9 (2.2) 10.4 (2.5) _0.05 Vmax Ao (cm/s) 70 (16) 71 (18) NS Vmax PV (cm/s) 69 (15) 72 (16) NS Vmax TV (cm/s) 46 (10) 51 (9) _0.05 Vmax MV (cm/s) 53 (17) 54 (18) NS Qp (L/min/m2) 3.7 (0.8) 4.3 (0.8) _0.05 Qs (L/min/m2) 4.0 (0.8) 4.0 (0.7) NS Qp/Qs 0.92 (0.14) 1.09 (0.23) _0.05 RV: right ventricle, LV: left ventricle, ED: end diastolic, ES: end systolic, SF: shortening fraction,Ao: aortic valve, LA: left atrium,Vmax: maximum Doppler Velocity, Qp: pulmonary output, Qs: systemic output, NS: non significant.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Purpose To characterize in vitro the loadability, physical properties, and release of irinotecan and doxorubicin from two commercially available embolization microspheres. Materials and Methods DC Bead (500-700 μm) and Hepasphere (400-600 μm) microspheres were loaded with either doxorubicin or irinotecan solutions. Drug amount was quantified with spectrophotometry, bead elasticity was measured under compression, and bead size and loading homogeneity were assessed with microscopy image analysis. Drug release was measured over 1-week periods in saline by using a pharmacopeia flow-through method. Results Almost complete drug loading was obtained for both microsphere types and drugs. Doxorubicin-loaded DC Beads maintained their spherical shape throughout the release. In contrast, Hepaspheres showed less homogeneous doxorubicin loading and, after release, some fractured microspheres. Incomplete doxorubicin release was observed in saline over 1 week (27% ± 2 for DC beads and 18% ± 7 for Hepaspheres; P = .013). About 75% of this amount was released within 2.2 hours for both beads. For irinotecan, complete release was obtained for both types of beads, in a sustained manner over 2-3 hours for DC Beads, and in a significantly faster manner as a 7-minute burst for Hepaspheres. Conclusions The two drug-eluting microspheres could be efficiently loaded with both drugs. Incomplete doxorubicin release was attributed to strong drug-bead ionic interactions. Weaker interactions were observed with irinotecan, which led to faster drug release.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The paper proposes an approach aimed at detecting optimal model parameter combinations to achieve the most representative description of uncertainty in the model performance. A classification problem is posed to find the regions of good fitting models according to the values of a cost function. Support Vector Machine (SVM) classification in the parameter space is applied to decide if a forward model simulation is to be computed for a particular generated model. SVM is particularly designed to tackle classification problems in high-dimensional space in a non-parametric and non-linear way. SVM decision boundaries determine the regions that are subject to the largest uncertainty in the cost function classification, and, therefore, provide guidelines for further iterative exploration of the model space. The proposed approach is illustrated by a synthetic example of fluid flow through porous media, which features highly variable response due to the parameter values' combination.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Two common herbicides; isoproturon and bentazon, are strong skin irritants and cross the skin barrier easily. Assessment of percutaneous absorption of these substances is a very important step in the evaluation of any dermal or transdermal dose, especially among agricultural workers who frequently have dermal exposures during crop treatment. The aims of the study were to determine the permeation rate of human skin for both herbicides in vitro, and histologically evaluate skin damage due to irritation at different concentrations. Skin penetration was assessed using a dynamic flow-through in vitro penetration system and analysis were performed with ion trap LC-MS (acidified water: acetronitile, C18 column). Two concentrations of bentazon (75 and 150 μg/mL) and isoproturon (125 and 250 μg/mL) in saline solution were applied on excised human skin from several donors. Saline water was used as receptor fluid. Collection times were: 4, 8, and 24 hours. After the experiments, the skin was removed and examined by histopathology for apoptosis, acanthosis, acantholysis and epidermolysis. The skin permeation rate, J, was calculated from the slope of the cumulative amount permeated as a function of time. The lag time, tL, was assigned from the time-axis intercept of the extrapolation of this linearity. Our results showed that tL for bentazon and isoproturon for both concentrations tested were similar; 2, 1.5 hours, respectively. Bentazon had a lowerer J compared to isoproturon; 350, 600 ng/cm2/h, respectively. Some acanthosis was observed after 8 hours of exposure to either of the two substances. In conclusion, our in vitro experiments demonstrate that bentazon and isoproturon cross the skin barrier within 2 hours even at very low concentrations, and showed some signs of skin damage. Future tests involve concentrations found in commercial products.