952 resultados para Vertical positions


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cross-hole radar tomography is a useful tool for mapping shallow subsurface electrical properties viz. dielectric permittivity and electrical conductivity. Common practice is to invert cross-hole radar data with ray-based tomographic algorithms using first arrival traveltimes and first cycle amplitudes. However, the resolution of conventional standard ray-based inversion schemes for cross-hole ground-penetrating radar (GPR) is limited because only a fraction of the information contained in the radar data is used. The resolution can be improved significantly by using a full-waveform inversion that considers the entire waveform, or significant parts thereof. A recently developed 2D time-domain vectorial full-waveform crosshole radar inversion code has been modified in the present study by allowing optimized acquisition setups that reduce the acquisition time and computational costs significantly. This is achieved by minimizing the number of transmitter points and maximizing the number of receiver positions. The improved algorithm was employed to invert cross-hole GPR data acquired within a gravel aquifer (4-10 m depth) in the Thur valley, Switzerland. The simulated traces of the final model obtained by the full-waveform inversion fit the observed traces very well in the lower part of the section and reasonably well in the upper part of the section. Compared to the ray-based inversion, the results from the full-waveform inversion show significantly higher resolution images. At either side, 2.5 m distance away from the cross-hole plane, borehole logs were acquired. There is a good correspondence between the conductivity tomograms and the natural gamma logs at the boundary of the gravel layer and the underlying lacustrine clay deposits. Using existing petrophysical models, the inversion results and neutron-neutron logs are converted to porosity. Without any additional calibration, the values obtained for the converted neutron-neutron logs and permittivity results are very close and similar vertical variations can be observed. The full-waveform inversion provides in both cases additional information about the subsurface. Due to the presence of the water table and associated refracted/reflected waves, the upper traces are not well fitted and the upper 2 m in the permittivity and conductivity tomograms are not reliably reconstructed because the unsaturated zone is not incorporated into the inversion domain.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dual-energy X-ray absorptiometry (DXA) is commonly used in the care of patients for diagnostic classification of osteoporosis, low bone mass (osteopenia), or normal bone density; assessment of fracture risk; and monitoring changes in bone density over time. The development of other technologies for the evaluation of skeletal health has been associated with uncertainties regarding their applications in clinical practice. Quantitative ultrasound (QUS), a technology for measuring properties of bone at peripheral skeletal sites, is more portable and less expensive than DXA, without the use of ionizing radiation. The proliferation of QUS devices that are technologically diverse, measuring and reporting variable bone parameters in different ways, examining different skeletal sites, and having differing levels of validating data for association with DXA-measured bone density and fracture risk, has created many challenges in applying QUS for use in clinical practice. The International Society for Clinical Densitometry (ISCD) 2007 Position Development Conference (PDC) addressed clinical applications of QUS for fracture risk assessment, diagnosis of osteoporosis, treatment initiation, monitoring of treatment, and quality assurance/quality control. The ISCD Official Positions on QUS resulting from this PDC, the rationale for their establishment, and recommendations for further study are presented here.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The best indirect evidence that increased bone turnover contributes to fracture risk is the fact that most of the proven therapies for osteoporosis are inhibitors of bone turnover. The evidence base that we can use biochemical markers of bone turnover in the assessment of fracture risk is somewhat less convincing. This relates to natural variability in the markers, problems with the assays, disparity in the statistical analyses of relevant studies and the independence of their contribution to fracture risk. More research is clearly required to address these deficiencies before biochemical markers might contribute a useful independent risk factor for inclusion in FRAX(®).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This issue review provides background on the establishment of full-time-equivalent, or FTE, positions and examines how FTE positions are used in the state's budgeting process. This issue review also provides historical information regarding FTE positions and personnel costs and the current status and outlook of FTE positions and salary expenditures for fiscal year 2011. In addition, this issue review outlines the new requirements included in Senate File 2088, Government Reorganization Efficiency Act, that will impact FTE levels and expenditure of salary dollars for fiscal 2011.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the n{body problem a central con guration is formed when the position vector of each particle with respect to the center of mass is a common scalar multiple of its acceleration vector. Lindstrom showed for n = 3 and for n > 4 that if n ? 1 masses are located at xed points in the plane, then there are only a nite number of ways to position the remaining nth mass in such a way that they de ne a central con guration. Lindstrom leaves open the case n = 4. In this paper we prove the case n = 4 using as variables the mutual distances between the particles.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Measuring the height of the vertical jump is an indicator of the strength and power of the lower body. The technological tools available to measure the vertical jump are black boxes and are not open to third-party verification or adaptation. We propose the creation of a measurement system called Chronojump-Boscosystem, consisting of open hardware and free software. Methods: A microcontroller was created and validated using a square wave generator and an oscilloscope. Two types of contact platforms were developed using different materials. These platforms were validated by the minimum pressure required for activation at different points by a strain gauge, together with the on/off time of our platforms in respect of the Ergojump-Boscosystem platform by a sample of 8 subjects performing submaximal jumps with one foot on each platform. Agile methodologies were used to develop and validate the software. Results: All the tools fall under the free software / open hardware guidelines and are, in that sense, free. The microcontroller margin of error is 0.1%. The validity of the fiberglass platform is 0.95 (ICC). The management software contains nearly 113.000 lines of code and is available in 7 languages.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This issue review provides updated information on an issue review published in December 2010, concerning the full-time-equivalent, or FTE, positions in state government. The background information provides a general explanation and understanding of the various aspects of FTE positions. This issue review includes year-end FTE and salary data for fiscal year 2011 and compares the data to prior years.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Vertical delineators are intended to warn drivers of an approaching curve while providing them with a better appreciation of the sharpness of a curve. Drivers can then select an appropriate speed before entering the curve. Delineation can also provide continuous tracking information once drivers are within the curve to help position their vehicles within the travel lane while traversing the curve. The most common type of vertical delineation is post mounted delineators (PMDs). These devices are usually flexible or rigid posts with some amount of reflective surface mounted along the roadside to provide additional delineation. Another treatment that has been used is to provide additional delineation on chevron posts.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Risk factors for fracture can be purely skeletal, e.g., bone mass, microarchitecture or geometry, or a combination of bone and falls risk related factors such as age and functional status. The remit of this Task Force was to review the evidence and consider if falls should be incorporated into the FRAX® model or, alternatively, to provide guidance to assist clinicians in clinical decision-making for patients with a falls history. It is clear that falls are a risk factor for fracture. Fracture probability may be underestimated by FRAX® in individuals with a history of frequent falls. The substantial evidence that various interventions are effective in reducing falls risk was reviewed. Targeting falls risk reduction strategies towards frail older people at high risk for indoor falls is appropriate. This Task Force believes that further fracture reduction requires measures to reduce falls risk in addition to bone directed therapy. Clinicians should recognize that patients with frequent falls are at higher fracture risk than currently estimated by FRAX® and include this in decision-making. However, quantitative adjustment of the FRAX® estimated risk based on falls history is not currently possible. In the long term, incorporation of falls as a risk factor in the FRAX® model would be ideal.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: The overeruption of upper molars due to the premature loss of antagonist teeth can be treated with the help of miniscrews. The aim of this study was to evaluate the movement of a typodont molar according to the biomechanical approach used with miniscrews. Study design: The study was conducted with four plaster models filled with typodont wax. In each model we used one absolute anchorage on the palatal side and another on the buccal side in different positions, thus generating four different biomechanical systems. A force of 150 g was applied to each side of the resin tooth. Periapical radiographs were taken preintrusion and immediately after completion of the intrusion. Photographs were taken in both the sagittal and occlusal planes every 3 min. The radiographic films and photographs were measured and compared. Results: A vertical movement of the molar was observed in all the models, with system 4 showing the greatest movement. Rotation in the occlusal plane only occurred in system 2, while in system 1 there was a change in the axial axis of 37 degrees. Conclusions: The anchorage site and the combination of forces applied may determine the resulting tooth movement

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recent studies have started to use media data to measure party positions and issue salience. The aim of this article is to compare and cross-validate this alternative approach with the more commonly used party manifestos, expert judgments and mass surveys. To this purpose, we present two methods to generate indicators of party positions and issue salience from media coverage: the core sentence approach and political claims analysis. Our cross-validation shows that with regard to party positions, indicators derived from the media converge with traditionally used measurements from party manifestos, mass surveys and expert judgments, but that salience indicators measure different underlying constructs. We conclude with a discussion of specific research questions for which media data offer potential advantages over more established methods.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Vertical Clearance Log is prepared for the purpose of providing vertical clearance restrictions by route on the primary road system. This report is used by the Iowa Department of Transportation’s Motor Carrier Services to route oversize vehicles around structures with vertical restrictions too low for the cargo height. The source of the data is the Geographic Information Management System (GIMS) that is managed by the Office of Research & Analytics in the Performance & Technology Division. The data is collected by inspection crews and through the use of LiDAR technology to reflect changes to structures on the primary road system. This log is produced annually.