947 resultados para Test method
Resumo:
1. Cluster analysis of reference sites with similar biota is the initial step in creating River Invertebrate Prediction and Classification System (RIVPACS) and similar river bioassessment models such as Australian River Assessment System (AUSRIVAS). This paper describes and tests an alternative prediction method, Assessment by Nearest Neighbour Analysis (ANNA), based on the same philosophy as RIVPACS and AUSRIVAS but without the grouping step that some people view as artificial. 2. The steps in creating ANNA models are: (i) weighting the predictor variables using a multivariate approach analogous to principal axis correlations, (ii) calculating the weighted Euclidian distance from a test site to the reference sites based on the environmental predictors, (iii) predicting the faunal composition based on the nearest reference sites and (iv) calculating an observed/expected (O/E) analogous to RIVPACS/AUSRIVAS. 3. The paper compares AUSRIVAS and ANNA models on 17 datasets representing a variety of habitats and seasons. First, it examines each model's regressions for Observed versus Expected number of taxa, including the r(2), intercept and slope. Second, the two models' assessments of 79 test sites in New Zealand are compared. Third, the models are compared on test and presumed reference sites along a known trace metal gradient. Fourth, ANNA models are evaluated for western Australia, a geographically distinct region of Australia. The comparisons demonstrate that ANNA and AUSRIVAS are generally equivalent in performance, although ANNA turns out to be potentially more robust for the O versus E regressions and is potentially more accurate on the trace metal gradient sites. 4. The ANNA method is recommended for use in bioassessment of rivers, at least for corroborating the results of the well established AUSRIVAS- and RIVPACS-type models, if not to replace them.
Resumo:
The object of this study is to assess informative possibilities of some technical indicators of the Test of Photos of Professions (BBT - Berufsbilder test), a projective method to clarify professional inclination, proposed by Martin Achtnich. This psychological evaluation technique is composed of 96 photos of professionals, performing various types of activities. The test subject classifies the photos into three groups: positive (agreeable), negative (disagreeable) and indifferent (neutral). Among those chosen positively, five preferences are chosen and a story is developed that includes them, an activity that is requested two times during the Vocational Guidance process: in the beginning (or middle) and at the end of the intervention. In this study, 160 stories were created by 80 youths, between 15 and 20 years of age, in public and private schools in a mid-sized Brazilian city. The stories were compared in three analytical categories: protagonist, professional conflict and resolution. The results were submitted to Wilcoxon nonparametric statistical analysis (p < .05), significant and relevant indicators of resolution being found in the process of occupational choice. This technical resource was shown, from this empirical evidence, to be promising for use in evaluation of intervention processes of Vocational Guidance.
Resumo:
The role of catecholamines in the control of the GnRH pulse generator is unclear as studies have relied on the use of peripheral or intracerebroventricular injections, which lack specificity in relation to the anatomical site of action. Direct brain site infusions have been used, however, these are limited by the ability to accurately target small brain regions. One such area of interest in the control of GnRH is the median eminence and arcuate nucleus within the medial basal hypothalamus. Here we describe a method of stereotaxically targeting this area in a large animal (sheep) and an infusion system to deliver drugs into unrestrained conscious animals. To test our technique we infused the dopamine agonist, quinpirole or vehicle into the medial basal hypothalamus of ovariectomised ewes. Quinpirole significantly suppressed LH pulsatility only in animals with injectors located close to the lateral median eminence. This in vivo result supports the hypothesis that dopamine inhibits GnRH secretion by presynaptic inhibition in the lateral median eminence. Also infusion of quinpirole into the medial basal hypothalamus suppressed prolactin secretion providing in vivo evidence that is consistent with the hypothesis that there are stimulatory autoreceptors on tubero-infundibular dopamine neurons. (C) 1997 Elsevier Science B.V.
Resumo:
Smoothing the potential energy surface for structure optimization is a general and commonly applied strategy. We propose a combination of soft-core potential energy functions and a variation of the diffusion equation method to smooth potential energy surfaces, which is applicable to complex systems such as protein structures; The performance of the method was demonstrated by comparison with simulated annealing using the refinement of the undecapeptide Cyclosporin A as a test case. Simulations were repeated many times using different initial conditions and structures since the methods are heuristic and results are only meaningful in a statistical sense.
Resumo:
Background: The 6-minute walk test (6MWT) is a well-known instrument for assessing the functional capacity of a variety of groups, including the obese. It is a simple, low-cost and easily applied method to objectively assess the level of exercise capacity. The aim of the present study was to study the functional capacity of a severely obese population before and after bariatric surgery. Methods: A total of 51 patients were studied. Of the 51 patients, 86.2% were women, and the mean age was 40.9 +/- 9.2 years. All 51 patients were evaluated preoperatively and 49 were evaluated 7-12 months postoperatively. The initial body mass index was 51.1 +/- 9.2 kg/m(2), and the final body mass index was 28.2 +/- 8.1 kg/m(2). All patients underwent Roux-en-Y gastric bypass. The 6MWT was performed in a hospital corridor, with patients attempting to cover as much distance as they could, walking back and forth for as long as possible within 6 minutes at their regular pace. The total distance, Borg Scale of perceived exhaustion, modified Borg dyspnea scale for shortness of breath, and physical complaints at the end of the test were recorded. In addition, the heart rate and respiratory frequency were assessed before and after the test. Results: The tolerance was good, and no injuries occurred at either evaluation. The patients` mean distance for the 6MWT was 381.9 +/- 49.3 m before surgery and 467.8 +/- 40.3 m after surgery (p < .0001). Similar results were observed for the other parameters assessed. Conclusion: The 6MWT provided useful information about the functional status of the obese patients undergoing bariatric surgery. A simple, safe, and powerful method to assess functional capacity of severely obese patients, the 6MWT is an objective test that might replace the conventional treadmill test for these types of patients. (Surg Obes Relat Dis 2009;5:540-543.) (C) 2009 American Society for Metabolic and Bariatric Surgery. All rights reserved.
Resumo:
Background/Aims: While laboratory methods for the detection of testicular tissue are well standardized, currently there is no available test to demonstrate the presence of ovarian tissue. We evaluated the effectiveness of gonadal stimulation with luteinizing hormone (LH)/follicle-stimulating hormone (FSH) for the detection of ovarian tissue in patients with disorders of sex development (DSD). Methods: Ten patients with congenital adrenal hyperplasia (CAH) as ovarian-positive controls, 10 with cryptorchidism (ovarian-negative controls), 13 patients with DSD of no defined etiology and 7 patients with ovotesticular DSD (true hermaphroditism, TH) were included in the study. They underwent a daily injection of both LH and FSH on 3 consecutive days. LH, FSH, estradiol, testosterone and inhibin A were measured before treatment, 24 h after the 1st dose and 24 h after the 3rd dose. Results: Estradiol increased in all CAH and TH patients, with a median value of 155.1 and 92.6 pg/ml, respectively, after the 3rd injection. Inhibin A also increased in all CAH and TH patients, with a median value of 70.4 and 32.2 pg/ml, respectively, after the 3rd injection. There was no change in these hormones in the other groups. Conclusion: The LH/FSH stimulation test might be a useful method to detect the presence of ovarian tissue. Copyright (C) 2009 S. Karger AG, Basel
Resumo:
Objective: Several limitations of published bioelectrical impedance analysis (BIA) equations have been reported. The aims were to develop in a multiethnic, elderly population a new prediction equation and cross-validate it along with some published BIA equations for estimating fat-free mass using deuterium oxide dilution as the reference method. Design and setting: Cross-sectional study of elderly from five developing countries. Methods: Total body water (TBW) measured by deuterium dilution was used to determine fat-free mass (FFM) in 383 subjects. Anthropometric and BIA variables were also measured. Only 377 subjects were included for the analysis, randomly divided into development and cross-validation groups after stratified by gender. Stepwise model selection was used to generate the model and Bland Altman analysis was used to test agreement. Results: FFM = 2.95 - 3.89 (Gender) + 0.514 (Ht(2)/Z) + 0.090 (Waist) + 0.156 (Body weight). The model fit parameters were an R(2), total F-Ratio, and the SEE of 0.88, 314.3, and 3.3, respectively. None of the published BIA equations met the criteria for agreement. The new BIA equation underestimated FFM by just 0.3 kg in the cross-validation sample. The mean of the difference between FFM by TBW and the new BIA equation were not significantly different; 95% of the differences were between the limits of agreement of -6.3 to 6.9 kg of FFM. There was no significant association between the mean of the differences and their averages (r = 0.008 and p = 0.2). Conclusions: This new BIA equation offers a valid option compared with some of the current published BIA equations to estimate FFM in elderly subjects from five developing countries.
Resumo:
We examined the correlation between results obtained from the in vivo Draize test for ocular irritation and in vitro results obtained from the sheep red blood cell (RBC) haemolytic assay, which assesses haemolysis and protein denaturation in erythrocytes, induced by cosmetic products. We sought to validate the haemolytic assay as a preliminary test for identifying highly-irritative products, and also to evaluate the in vitro test as alternative assay for replacement of the in vivo test. In vitro and in vivo analyses were carried out on 19 cosmetic products, in order to correlate the lesions in the ocular structures with three in vitro parameters: (i) the extent of haemolysis (H50); (ii) the protein denaturation index (131); and (iii) the H50/DI ratio, which reflects the irritation potential (IP). There was significant correlation between maximum average scores (MAS) and the parameters determined in vitro (r = 0.752-0.764). These results indicate that the RBC assay is a useful and rapid test for use as a screening method to assess the IP of cosmetic products, and for predicting the IP value with a high level of concordance (94.7%). The assay showed high sensitivity and specificity rates of 91.6% and 100%, respectively.
Resumo:
A nongravimetric acetyl bromide lignin (ABL) method was evaluated to quantify lignin concentration in a variety of plant materials. The traditional approach to lignin quantification required extraction of lignin with acidic dioxane and its isolation from each plant sample to construct a standard curve via spectrophotometric analysis. Lignin concentration was then measured in pre-extracted plant cell walls. However, this presented a methodological complexity because extraction and isolation procedures are lengthy and tedious, particularly if there are many samples involved. This work was targeted to simplify lignin quantification. Our hypothesis was that any lignin, regardless of its botanical origin, could be used to construct a standard curve for the purpose of determining lignin concentration in a variety of plants. To test our hypothesis, lignins were isolated from a range of diverse plants and, along with three commercial lignins, standard curves were built and compared among them. Slopes and intercepts derived from these standard curves were close enough to allow utilization of a mean extinction coefficient in the regression equation to estimate : lignin concentration in any plant, independent of its botanical origin. Lignin quantification by use of a common regression equation obviates the steps of lignin extraction, isolation, and standard curve construction, which substantially expedites the ABL method. Acetyl bromide lignin method is a fast, convenient analytical procedure that may routinely be used to quantify lignin.
Resumo:
Purpose: To assess the effects of three different dental adhesive systems on the formation of secondary root caries, in vitro, with a standardized interfacial gap in a filled cavity model. Methods: 40 sound human molars were selected and randomly assigned to four experimental groups: Clearfil SE Bond (CSEB), Xeno III (X-III), Scotchbond Multi-Purpose Plus (SBMP) and negative control (NC) without an adhesive system. After the standardized Class V cavity preparations on the buccal and lingual surfaces, restorations were placed with resin composite (Filtek Z250) using a standardized interfacial gap, using a 3 x 2 mm piece of 50 mu m metal matrix. The teeth were sterilized with gamma irradiation and exposed to a cariogenic challenge using a bacterial system with Streptococcus mutans. Depth and extension of wall lesions formed and the depth of outer lesions were measured by software coupled with light microscopy. Results: For wall lesion extension the ANOVA test showed differences between groups except between X-HI and SBMP (P= 0.294). The Tukey`s test of confidence intervals indicated smaller values for the CSEB group than for the others. For wall lesion depth the CSEB group also presented the smallest mean values of wall lesion depth when compared to the others (P< 0.0001) for all comparisons using Tukey`s test. Regarding outer lesion depth, all adhesives showed statistically similar behavior. SEM evaluation of the morphologic appearance of caries lesions confirmed the statistical results showing small caries lesion development for cavities restored with CSEB adhesive system, which may suggest that this adhesive system interdiffusion zone promoted a good interaction with subjacent dentin protecting the dental tissues from recurrent caries. (Am J Dent 2010;23:93-97).
Resumo:
Objective. The goal of this paper is to undertake a literature search collecting all dentin bond strength data obtained for six adhesives with four tests ( shear, microshear, tensile and microtensile) and to critically analyze the results with respect to average bond strength, coefficient of variation, mode of failure and product ranking. Method. A PubMed search was carried out for the years between 1998 and 2009 identifying publications on bond strength measurements of resin composite to dentin using four tests: shear, tensile, microshear and microtensile. The six adhesive resins were selected covering three step systems ( OptiBond FL, Scotch Bond Multi-Purpose Plus), two-step (Prime & Bond NT, Single Bond, Clear. l SE Bond) and one step (Adper Prompt L Pop). Results. Pooling results from 147 references showed an ongoing high scatter in the bond strength data regardless which adhesive and which bond test was used. Coefficients of variation remained high (20-50%) even with the microbond test. The reported modes of failure for all tests still included high number of cohesive failures. The ranking seemed to be dependant on the test used. Significance. The scatter in dentin bond strength data remains regardless which test is used confirming Finite Element Analysis predicting non-uniform stress distributions due to a number of geometrical, loading, material properties and specimens preparation variables. This reopens the question whether, an interfacial fracture mechanics approach to analyze the dentin - adhesive bond is not more appropriate for obtaining better agreement among dentin bond related papers. (C) 2009 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Resumo:
This study evaluated the effect of the C-factor and dentin preparation method (DPM) in the bond strength (BS) of a mild self-etch adhesive; the study also observed the SEM superficial aspects of the corresponding smear layer. For purposes of this study, 25 molars (n=5) were used in a bond strength test. The molars were divided into two parts (buccal and lingual): one part received a Class V cavity (C-factor=3) and the other received a flat surface (C-factor=0) with the same bur type (coarse diamond or carbide bur and fine diamond or carbide bur), both within the same dentin depth. Five teeth were prepared with wet 60-grit and 600-grit SiC papers. After restoration with Clearfil SE Bond, microtensile beans (0.8 mm(2)) were prepared and tested after 24 hours in a universal testing machine (0.5 mm/minute). An additional two teeth for each DPM were prepared for SEM evaluation of the smear layer superficial aspects. The BS values were submitted to one-way ANOVA, considering only the DPM (flat surfaces) and two-way ANOVA (C-Factor x DPM, considering only burs) with p=0.05. Although the DPM in the flat surfaces was not significant, the standard deviations of carbide bur-prepared specimens were markedly lower. The BS was significantly lower in cavities. The fine carbide bur presented the most favorable smear layer aspect. It was concluded that different dentin preparation methods could not prevent the adverse effect in bond strength of a high C-factor. A coarse cut carbide bur should be avoided prior to a mild self-etch adhesive, because it adversely affected bond strength. In contrast, a fine cut carbide bur provided the best combination: high bond strength with low variability, which suggests a more reliable bond strength performance.
Resumo:
In this paper we present the composite Euler method for the strong solution of stochastic differential equations driven by d-dimensional Wiener processes. This method is a combination of the semi-implicit Euler method and the implicit Euler method. At each step either the semi-implicit Euler method or the implicit Euler method is used in order to obtain better stability properties. We give criteria for selecting the semi-implicit Euler method or the implicit Euler method. For the linear test equation, the convergence properties of the composite Euler method depend on the criteria for selecting the methods. Numerical results suggest that the convergence properties of the composite Euler method applied to nonlinear SDEs is the same as those applied to linear equations. The stability properties of the composite Euler method are shown to be far superior to those of the Euler methods, and numerical results show that the composite Euler method is a very promising method. (C) 2001 Elsevier Science B.V. All rights reserved.
Resumo:
Purpose: The aim of this study was to assess the accuracy of a (CO2)-C-13 breath test for the prediction of short-duration energy expenditure. Methods: Eight healthy volunteers walked at 1.5 km.h(-1) for 60 min followed by 60-min recovery. During this time, the energy cost of physical activity was measured via respiratory calorimetry and a C-13 bicarbonate breath test. A further eight subjects were tested using the same two methods during a 60-min cycle at 0.5 kp. 30 ipm followed by a 60-min recovery. The rate of appearance of (CO2)-C-13, (RaCO2) was measured and the mean ratio, (V) over dot CO2/RaCO2 was used to calculate energy expenditure using the isotopic approach. Results: As would be expected, there was a significant difference in the energy cost of walking and cycling using both methods (P < 0.05). However. no significant differences were observed between respiratory calorimetry and the isotope method for measurement of energy expenditure while walking or cycling. Conclusions: These data suggest that the C-13 breath test is a valid method that can be used to measure the energy cost of short duration physical activity in a field setting.
Resumo:
We have developed a highly sensitive cytolysis test, the fluorolysis assay, as a simple nonradioactive and inexpensive alternative to the standard Cr-51-release assay. P815 cells were stably transfected with a plasmid expressing the enhanced green fluorescent protein (EGFP) gene. These target cells were coated with or without cognate peptide or anti-CD3 Ab and then incubated with CD8(+) T cells to allow antigen-specific or nonspecific lysis. The degree of target cell lysis was measured using flow cytometry to count the percentage of viable propidium iodide(-) EGFP(+) cells, whose numbers were standardized to a reference number of fluorochrome-linked beads. By using small numbers of target cells (200-800 per reaction) and extended incubation times (up to 2 days), the antigen-specific cytolytic activity of one to two activated CD8(+) T cells of a CTL line could be detected. The redirected fluorolysis assay also measured the activity of very few ( greater than or equal to6) primary CD8(+) T cells following polyclonal activation. Importantly, antigen-specific lysis by small numbers ( greater than or equal to 25) of primary CD8(+) T cells could be directly measured ex vivo. This exquisite sensitivity of the fluorolysis assay, which was at least 8-33-folds higher than an optimized 51 Cr-release assay, allows in vitro and ex vivo studies of immune responses that would otherwise not be possible due to low CTL numbers or frequencies. (C) 2002 Elsevier Science B.V. All rights reserved.