998 resultados para TISSUE DOPPLER VELOCITY
Resumo:
INTRODUCTION Although several parameters have been proposed to predict the hemodynamic response to fluid expansion in critically ill patients, most of them are invasive or require the use of special monitoring devices. The aim of this study is to determine whether noninvasive evaluation of respiratory variation of brachial artery peak velocity flow measured using Doppler ultrasound could predict fluid responsiveness in mechanically ventilated patients. METHODS We conducted a prospective clinical research in a 17-bed multidisciplinary ICU and included 38 mechanically ventilated patients for whom fluid administration was planned due to the presence of acute circulatory failure. Volume expansion (VE) was performed with 500 mL of a synthetic colloid. Patients were classified as responders if stroke volume index (SVi) increased >or= 15% after VE. The respiratory variation in Vpeakbrach (DeltaVpeakbrach) was calculated as the difference between maximum and minimum values of Vpeakbrach over a single respiratory cycle, divided by the mean of the two values and expressed as a percentage. Radial arterial pressure variation (DeltaPPrad) and stroke volume variation measured using the FloTrac/Vigileo system (DeltaSVVigileo), were also calculated. RESULTS VE increased SVi by >or= 15% in 19 patients (responders). At baseline, DeltaVpeakbrach, DeltaPPrad and DeltaSVVigileo were significantly higher in responder than nonresponder patients [14 vs 8%; 18 vs. 5%; 13 vs 8%; P < 0.0001, respectively). A DeltaVpeakbrach value >10% predicted fluid responsiveness with a sensitivity of 74% and a specificity of 95%. A DeltaPPrad value >10% and a DeltaSVVigileo >11% predicted volume responsiveness with a sensitivity of 95% and 79%, and a specificity of 95% and 89%, respectively. CONCLUSIONS Respiratory variations in brachial artery peak velocity could be a feasible tool for the noninvasive assessment of fluid responsiveness in patients with mechanical ventilatory support and acute circulatory failure. TRIAL REGISTRATION ClinicalTrials.gov ID: NCT00890071.
Resumo:
AIM: Patients with non-insulin-dependent diabetes mellitus (NIDDM) are at increased cardiovascular risk due to an accelerated atherosclerotic process. The present study aimed to compare skin microvascular function, pulse wave velocity (PWV), and a variety of hemostatic markers of endothelium injury [von Willebrand factor (vWF), plasminogen activator inhibitor-1 (PAI-1), tissue plasminogen activator (t-PA), tissue factor pathway inhibitor (TFPI), and the soluble form of thrombomodulin (s-TM)] in patients with NIDDM. METHODS: 54 patients with NIDDM and 38 sex- and age-matched controls were studied. 27 diabetics had no overt micro- and/or macrovascular complications, while the remainder had either or both. The forearm skin blood flow was assessed by laser-Doppler imaging, which allowed the measurement of the response to iontophoretically applied acetylcholine (endothelium-dependent vasodilation) and sodium nitroprusside (endothelium-independent vasodilation), as well as the reactive hyperemia triggered by the transient occlusion of the circulation. RESULTS: Both endothelial and non-endothelial reactivity were significantly blunted in diabetics, regardless of the presence or the absence of vascular complications. Plasma vWF, TFPI and s-TM levels were significantly increased compared with controls only in patients exhibiting vascular complications. Concentrations of t-PA and PAI-1 were significantly increased in the two groups of diabetics versus controls. CONCLUSION: In NIDDM, both endothelium-dependent and -independent microvascular skin reactivity are impaired, whether or not underlying vascular complications exist. It also appears that microvascular endothelial dysfunction is not necessarily associated in NIDDM with increased circulating levels of hemostatic markers of endothelial damage known to reflect a hypercoagulable state.
Resumo:
OBJECTIVE: Absent or reverse end-diastolic flow (Doppler II/III) in umbilical artery is correlated with poor perinatal outcome, particularly in intrauterine growth restricted (IUGR) fetuses. The optimal timing of delivery is still controversial. We studied the short- and long-term morbidity and mortality among these children associated with our defined management. STUDY DESIGN: Sixty-nine IUGR fetuses with umbilical Doppler II/III were divided into three groups; Group 1, severe early IUGR, no therapeutic intervention (n = 7); Group 2, fetuses with pathological biophysical profile, immediate delivery (n = 35); Group 3, fetuses for which expectant management had been decided (n = 27). RESULTS: In Group 1, stillbirth was observed after a mean delay of 6.3 days. Group 2 delivered at an average of 31.6 weeks and two died in the neonatal period (6%). In Group 3 after a mean delay of 8 days, average gestational age at delivery was 31.7 weeks; two intra uterine and four perinatal deaths were observed (22%). Long-term follow-up revealed no sequelae in 25/31 (81%) and 15/18 (83%), and major handicap occurred in 1 (3%) and 2 patients (11%), respectively, for Groups 2 and 3. CONCLUSION: Fetal mortality was observed in 22% of this high risk group. After a mean period of follow-up of 5 years, 82% of infants showed no sequelae. According to our management, IUGR associated with umbilical Doppler II or III does not show any benefit from an expectant management in term of long-term morbidity.
Resumo:
Background. Age is an important risk factor for perioperative cerebral complications such as stroke, postoperative cognitive dysfunction, and delirium. We explored the hypothesis that intraoperative cerebrovascular autoregulation is less efficient and brain tissue oxygenation lower in elderly patients, thus, increasing the vulnerability of elderly brains to systemic insults such as hypotension.Methods. We monitored intraoperative cerebral perfusion in 50 patients aged 18-40 and 77 patients >65 yr at two Swiss university hospitals. Mean arterial pressure (MAP) was measured continuously using a plethysmographic method. An index of cerebrovascular autoregulation (Mx) was calculated based on changes in transcranial Doppler flow velocity due to changes in MAP. Cerebral oxygenation was assessed by the tissue oxygenation index (TOI) using near-infrared spectroscopy. End-tidal CO(2), O(2), and sevoflurane concentrations and peripheral oxygen saturation were recorded continuously. Standardized anaesthesia was administered in all patients (thiopental, sevoflurane, fentanyl, atracurium).Results. Autoregulation was less efficient in patients aged >65 yr [by 0.10 (SE 0.04; P=0.020)] in a multivariable linear regression analysis. This difference was not attributable to differences in MAP, end-tidal CO2, or higher doses of sevoflurane. TOI was not significantly associated with age, sevoflurane dose, or Mx but increased with increasing flow velocity [by 0.09 (SE 0.04; P=0.028)] and increasing MAP [by 0.11 (SE 0.05; P=0.043)].Conclusions. Our results do not support the hypothesis that older patients' brains are more vulnerable to systemic insults. The difference of autoregulation between the two groups was small and most likely clinically insignificant.
Resumo:
We present the dynamic velocity profiles of a Newtonian fluid (glycerol) and a viscoelastic Maxwell fluid (CPyCl-NaSal in water) driven by an oscillating pressure gradient in a vertical cylindrical pipe. The frequency range explored has been chosen to include the first three resonance peaks of the dynamic permeability of the viscoelastic-fluid¿pipe system. Three different optical measurement techniques have been employed. Laser Doppler anemometry has been used to measure the magnitude of the velocity at the center of the liquid column. Particle image velocimetry and optical deflectometry are used to determine the velocity profiles at the bulk of the liquid column and at the liquid-air interface respectively. The velocity measurements in the bulk are in good agreement with the theoretical predictions of a linear theory. The results, however, show dramatic differences in the dynamic behavior of Newtonian and viscoelastic fluids, and demonstrate the importance of resonance phenomena in viscoelastic fluid flows, biofluids in particular, in confined geometries.
Resumo:
BACKGROUND: Angiographic studies suggest that acute vasospasm within 48 h of aneurysmal subarachnoid hemorrhage (SAH) predicts symptomatic vasospasm. However, the value of transcranial Doppler within 48 h of SAH is unknown. METHODS: We analyzed 199 patients who had at least 1 middle cerebral artery (MCA) transcranial Doppler examination within 48 h of SAH onset. Abnormal MCA mean blood flow velocity (mBFV) was defined as >90 cm/s. Delayed cerebral ischemia (DCI) was defined as clinical deterioration or radiological evidence of infarction due to vasospasm. RESULTS: Seventy-six patients (38%) had an elevation of MCA mBFV >90 cm/s within 48 h of SAH onset. The predictors of elevated mBFV included younger age (OR = 0.97 per year of age, p = 0.002), admission angiographic vasospasm (OR = 5.4, p = 0.009) and elevated white blood cell count (OR = 1.1 per 1,000 white blood cells, p = 0.003). Patients with elevated mBFV were more likely to experience a 10 cm/s fall in velocity at the first follow-up than those with normal baseline velocities (24 vs. 10%, p < 0.01), suggestive of resolving spasm. DCI developed in 19% of the patients. An elevated admission mBFV >90 cm/s during the first 48 h (adjusted OR = 2.7, p = 0.007) and a poor clinical grade (Hunt-Hess score 4 or 5, OR = 3.2, p = 0.002) were associated with a significant increase in the risk of DCI. CONCLUSION: Early elevations of mBFV correlate with acute angiographic vasospasm and are associated with a significantly increased risk of DCI. Transcranial Doppler ultrasound may be an early useful tool to identify patients at higher risk to develop DCI after SAH.
Resumo:
We present a full field laser Doppler imaging instrument, which enables real-time in vivo assessment of blood flow in dermal tissue and skin. This instrument monitors the blood perfusion in an area of about 50 cm(2) with 480 × 480 pixels per frame at a rate of 12-14 frames per second. Smaller frames can be monitored at much higher frame rates. We recorded the microcirculation in healthy skin before, during and after arterial occlusion. In initial clinical case studies, we imaged the microcirculation in burned skin and monitored the recovery of blood flow in a skin flap during reconstructive surgery indicating the high potential of LDI for clinical applications. Small animal imaging in mouse ears clearly revealed the network of blood vessels and the corresponding blood perfusion.
Resumo:
Background: It is unknown whether cerebral perfusion in geriatric and younger patients under general anaesthesia differs. Methods: We compared 2 groups of patients undergoing elective major non-cardiac surgery under standardized general anaesthesia (thiopental, sevoflurane, fentanyl, atracurium). Group 1: 18-40 yrs (n = 20), Group 2: >65 yrs (n = 37). Cerebral perfusion was investigated with transcranial Doppler and near-infrared spectroscopy (NIRS). Arterial blood pressure was monitored continuously with a Finapres device. Mx, an index allowing continuous monitoring of cerebrovascular autoregulation based on the changes in mean arterial blood pressure (MAP) and cerebral blood flow velocity was calculated. Data are shown as mean } SD. Results: MAP (86 } 9.6 vs 79 } 10.9 mm Hg, p = 0.02), end-tidal concentration of sevoflurane (1.9 } 0.3 vs 1.6 } 0.3%, p <0.01), and the cerebral tissue oxygenation index measured by NIRS (72 } 4 vs 68 } 5%, p = 0.01), were significantly lower in Group 2. The end-tidal concentration of O2 was significantly higher in Group 2 (46 } 4 vs 48 } 4% p = 0.04). There were no significant differences between Group 1 and 2 for cerebral blood flow velocity (41 } 10 vs 43 } 18 cm/s), end tidal CO2 (4.7 } 0.3 vs 4.6 } 0.3 kPa) and cerebrovascular autoregulation (Mx 0.42 } 0.2 vs 0.48 } 0.2). In Group 1 35% and in Group 2 43% of the patients had an index of autoregulation suggesting disturbed cerebrovascular autoregulation (p = n.s.). Conclusions: In elderly patients under general anaesthesia with sevoflurane the cerebral tissue oxygenation index was significantly lower than in younger patients despite higher end-tidal oxygen concentrations. Our data suggest subtle differences in cerebral perfusion between geriatric and younger
Resumo:
OBJECTIVE: Transcranial Doppler (TCD) is widely used to monitor the temporal course of vasospasm after subarachnoid hemorrhage (SAH), but its ability to predict clinical deterioration or infarction from delayed cerebral ischemia (DCI) remains controversial. We sought to determine the prognostic utility of serial TCD examination after SAH. METHODS: We analyzed 1877 TCD examinations in 441 aneurysmal SAH patients within 14 days of onset. The highest mean blood flow velocity (mBFV) value in any vessel before DCI onset was recorded. DCI was defined as clinical deterioration or computed tomographic evidence of infarction caused by vasospasm, with adjudication by consensus of the study team. Logistic regression was used to calculate adjusted odds ratios for DCI risk after controlling for other risk factors. RESULTS: DCI occurred in 21% of patients (n = 92). Multivariate predictors of DCI included modified Fisher computed tomographic score (P = 0.001), poor clinical grade (P = 0.04), and female sex (P = 0.008). After controlling for these variables, all TCD mBFV thresholds between 120 and 180 cm/s added a modest degree of incremental predictive value for DCI at nearly all time points, with maximal sensitivity by SAH day 8. However, the sensitivity of any mBFV more than 120 cm/s for subsequent DCI was only 63%, with a positive predictive value of 22% among patients with Hunt and Hess grades I to III and 36% in patients with Hunt and Hess grades IV and V. Positive predictive value was only slightly higher if mBFV exceeded 180 cm/s. CONCLUSION: Increased TCD flow velocities imply only a mild incremental risk of DCI after SAH, with maximal sensitivity by day 8. Nearly 40% of patients with DCI never attained an mBFV more than 120 cm/s during the course of monitoring. Given the poor overall sensitivity of TCD, improved methods for identifying patients at high risk for DCI after SAH are needed.
Resumo:
AbstractObjective:Longitudinal study with B-mode ultrasonography and Doppler ultrasonography of maternal kidneys and liver in low-risk pregnancy, to establish and quantify normality parameters, correlating them with physiological changes.Materials and Methods:Twenty-five pregnant women were assessed and selected to participate in the study, each of them undergoing four examinations at the first, second, third trimesters and postpartum.Results:Findings during pregnancy were the following: increased renal volume, pyelocaliceal dilatation with incidence of 45.4% in the right kidney, and 9% in the left kidney; nephrolithiasis, 18.1% in the right kidney, 13.6% in the left kidney. With pyelocaliceal dilatation, mean values for resistivity index were: 0.68 for renal arteries; 0.66 for segmental arteries; 0.64 for interlobar arteries; 0.64 for arcuate arteries. Without pyelocaliceal dilatation, 0.67 for renal arteries; 0.64 for segmental arteries; 0.63 for interlobar arteries; and 0.61 for arcuate arteries. Portal vein flow velocities presented higher values in pregnancy, with mean value for maximum velocity of 28.9 cm/s, and 22.6 cm/s postpartum. The waveform pattern of the right hepatic vein presented changes persisting in the postpartum period in 31.8% of the patients. Cholelithiasis was observed in 18.1% of the patients.Conclusion:Alterations in renal volume, pyelocaliceal dilatation, nephrolithiasis, cholelithiasis, changes in portal vein flow velocity, alterations in waveform pattern of the right hepatic vein, proved to be significant.
Resumo:
This study aimed to assess whether there are differences in Doppler velocimetry parameters between different sizes. Twenty dogs were equally divided into small and large groups used in this study. The dogs were evaluated using Triplex ultrasound. Testicular artery was located by Colour Doppler in the spermatic cord, marginal to the testes and intratesticular segments and then, spectral Doppler were used to calculate: peak systolic velocity (PSV), end diastolic velocity (EDV), resistance index (RI) and pulsatility index (PI). The mean testicular volume in the left side was significantly higher than the right side, in both groups. Doppler examination showed higher velocities (EDV) at spermatic cord in large dogs; marginal to the testes was observed higher velocities in small dogs; intratesticular region no differences were observed (P < 0.05) and within the groups differences between segments of the artery were also observed for each parameter. The results showed that there are differences in Doppler velocimetry parameters between different sizes.
Resumo:
Borderline hypertension (BH) has been associated with an exaggerated blood pressure (BP) response during laboratory stressors. However, the incidence of target organ damage in this condition and its relation to BP hyperreactivity is an unsettled issue. Thus, we assessed the Doppler echocardiographic profile of a group of BH men (N = 36) according to office BP measurements with exaggerated BP in the cycloergometric test. A group of normotensive men (NT, N = 36) with a normal BP response during the cycloergometric test was used as control. To assess vascular function and reactivity, all subjects were submitted to the cold pressor test. Before Doppler echocardiography, the BP profile of all subjects was evaluated by 24-h ambulatory BP monitoring. All subjects from the NT group presented normal monitored levels of BP. In contrast, 19 subjects from the original BH group presented normal monitored BP levels and 17 presented elevated monitored BP levels. In the NT group all Doppler echocardiographic indexes were normal. All subjects from the original BH group presented normal left ventricular mass and geometrical pattern. However, in the subjects with elevated monitored BP levels, fractional shortening was greater, isovolumetric relaxation time longer, and early to late flow velocity ratio was reduced in relation to subjects from the original BH group with normal monitored BP levels (P<0.05). These subjects also presented an exaggerated BP response during the cold pressor test. These results support the notion of an integrated pattern of cardiac and vascular adaptation during the development of hypertension.
Resumo:
Although echocardiography has been used in rats, few studies have determined its efficacy for estimating myocardial infarct size. Our objective was to estimate the myocardial infarct size, and to evaluate anatomic and functional variables of the left ventricle. Myocardial infarction was produced in 43 female Wistar rats by ligature of the left coronary artery. Echocardiography was performed 5 weeks later to measure left ventricular diameter and transverse area (mean of 3 transverse planes), infarct size (percentage of the arc with infarct on 3 transverse planes), systolic function by the change in fractional area, and diastolic function by mitral inflow parameters. The histologic measurement of myocardial infarction size was similar to the echocardiographic method. Myocardial infarct size ranged from 4.8 to 66.6% when determined by histology and from 5 to 69.8% when determined by echocardiography, with good correlation (r = 0.88; P < 0.05; Pearson correlation coefficient). Left ventricular diameter and mean diastolic transverse area correlated with myocardial infarct size by histology (r = 0.57 and r = 0.78; P < 0.0005). The fractional area change ranged from 28.5 ± 5.6 (large-size myocardial infarction) to 53.1 ± 1.5% (control) and correlated with myocardial infarct size by echocardiography (r = -0.87; P < 0.00001) and histology (r = -0.78; P < 00001). The E/A wave ratio of mitral inflow velocity for animals with large-size myocardial infarction (5.6 ± 2.7) was significantly higher than for all others (control: 1.9 ± 0.1; small-size myocardial infarction: 1.9 ± 0.4; moderate-size myocardial infarction: 2.8 ± 2.3). There was good agreement between echocardiographic and histologic estimates of myocardial infarct size in rats.
Resumo:
The severity of left ventricular (LV) dysfunction in rats with myocardial infarction (MI) varies widely. Because homogeneity in baseline parameters is essential for experimental investigations, a study was conducted to establish whether Doppler echocardiography (DE) could accurately identify animals with high LV end-diastolic pressure as a marker of LV dysfunction soon after MI. Direct measurements of LV end-diastolic pressure were made and DE was performed simultaneously 1 week after surgically induced MI (N = 16) or sham-operation (N = 17) in female Wistar rats (200 to 250 g). The ratio of peak early (E) to late (A) diastolic LV filling velocities and the ratio of E velocity to peak early (Em) diastolic myocardial velocity were the best predictors of high LV end-diastolic pressure (>12 mmHg) soon after MI. Cut-off values of 1.77 for the E/A ratio (P = 0.001) identified rats with elevated LV end-diastolic pressure with 90% sensitivity and 80% specificity. Cut-off values of 20.4 for the E/Em ratio (P = 0.0001) identified rats with elevated LV end-diastolic pressure with 81.8% sensitivity and 80% specificity. Moreover, E/A and E/Em ratios were the only echocardiographic parameters independently associated with LV end-diastolic pressure in multiple linear regression analysis. Therefore, DE identifies rats with high LV end-diastolic pressure soon after MI. These findings have implications for using serial DE in animal selection and in the assessment of their response to experimental therapies.
Resumo:
Although enteropathogenic Escherichia coli (EPEC) are well-recognized diarrheal agents, their ability to translocate and cause extraintestinal alterations is not known. We investigated whether a typical EPEC (tEPEC) and an atypical EPEC (aEPEC) strain translocate and cause microcirculation injury under conditions of intestinal bacterial overgrowth. Bacterial translocation (BT) was induced in female Wistar-EPM rats (200-250 g) by oroduodenal catheterization and inoculation of 10 mL 10(10) colony forming unit (CFU)/mL, with the bacteria being confined between the duodenum and ileum with ligatures. After 2 h, mesenteric lymph nodes (MLN), liver and spleen were cultured for translocated bacteria and BT-related microcirculation changes were monitored in mesenteric and abdominal organs by intravital microscopy and laser Doppler flow, respectively. tEPEC (N = 11) and aEPEC (N = 11) were recovered from MLN (100%), spleen (36.4 and 45.5%), and liver (45.5 and 72.7%) of the animals, respectively. Recovery of the positive control E. coli R-6 (N = 6) was 100% for all compartments. Bacteria were not recovered from extraintestinal sites of controls inoculated with non-pathogenic E. coli strains HB101 (N = 6) and HS (N = 10), or saline. Mesenteric microcirculation injuries were detected with both EPEC strains, but only aEPEC was similar to E. coli R-6 with regard to systemic tissue hypoperfusion. In conclusion, overgrowth of certain aEPEC strains may lead to BT and impairment of the microcirculation in systemic organs.