881 resultados para Stop-motion


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We study the erratic displacement of spiral waves forced to move in a medium with random spatiotemporal excitability. Analytical work and numerical simulations are performed in relation to a kinematic scheme, assumed to describe the autowave dynamics for weakly excitable systems. Under such an approach, the Brownian character of this motion is proved and the corresponding dispersion coefficient is evaluated. This quantity shows a nontrivial dependence on the temporal and spatial correlation parameters of the external fluctuations. In particular, a resonantlike behavior is neatly evidenced in terms of the noise correlation time for the particular situation of spatially uniform fluctuations. Actually, this case turns out to be, to a large extent, exactly solvable, whereas a pair of dispersion mechanisms are discussed qualitatively and quantitatively to explain the results for the more general scenario of spatiotemporal disorder.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: MR tissue tagging allows the noninvasive assessment of the locally and temporally resolved motion pattern of the left ventricle. Alterations in cardiac torsion and diastolic relaxation of the left ventricle were studied in patients with aortic stenosis and were compared with those of healthy control subjects and championship rowers with physiological volume-overload hypertrophy. METHODS AND RESULTS: Twelve aortic stenosis patients, 11 healthy control subjects with normal left ventricular function, and 11 world-championship rowers were investigated for systolic and diastolic heart wall motion on a basal and an apical level of the myocardium. Systolic torsion and untwisting during diastole were examined by use of a novel tagging technique (CSPAMM) that provides access to systolic and diastolic motion data. In the healthy heart, the left ventricle performs a systolic wringing motion, with a counterclockwise rotation at the apex and a clockwise rotation at the base. Apical untwisting precedes diastolic filling. In the athlete's heart, torsion and untwisting remain unchanged compared with those of the control subjects. In aortic stenosis patients, torsion is significantly increased and diastolic apical untwisting is prolonged compared with those of control subjects or athletes. CONCLUSIONS: Torsional behavior as observed in pressure- and volume-overloaded hearts is consistent with current theoretical findings. A delayed diastolic untwisting in the pressure-overloaded hearts of the patients may contribute to a tendency toward diastolic dysfunction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The feasibility to measure brain perfusion using intravoxel incoherent motion (IVIM) MRI has been reported recently with currently clinically available technology. The method is intrinsically local and quantitative, but is contaminated by partial volume effects with cerebrospinal fluid (CSF). Signal from CSF can be suppressed by a 180° inversion recovery (180°-IR) magnetization preparation, but this also leads to strong suppression of blood and brain tissue signal. Here, we take advantage of the different T2 relaxations of blood and brain relative to CSF, and implement a T2 -prepared IVIM (T2prep IVIM) inversion recovery acquisition, which permits a recovery of between 43% and 57% of arterial and venous blood magnetization at excitation time compared with the theoretical recovery of between 27% and 30% with a standard 180°-IR. We acquired standard IVIM (IVIM), T2prep IVIM and dynamic susceptibility contrast (DSC) images at 3 T using a 32-multichannel receiver head coil in eight patients with known large high-grade brain tumors. We compared the contrast and contrast-to-noise ratio obtained in the corresponding cerebral blood volume images quantitatively, as well as subjectively by two neuroradiologists. Our findings suggest that quantitative cerebral blood volume contrast and contrast-to-noise ratio, as well as subjective lesion detection, contrast quality and diagnostic confidence, are increased with T2prep IVIM relative to IVIM and DSC.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Gastric cancer affects about one million people per year worldwide, being the second leading cause of cancer mortality. The study of its etiology remains therefore a global issue as it may allow the identification of major targets, besides eradication of Helicobacter pylori infection, for primary prevention. It has however received little attention, given its comparatively low incidence in most high-income countries. We introduce a consortium of epidemiological investigations named the 'Stomach cancer Pooling (StoP) Project'. Twenty-two studies agreed to participate, for a total of over 9000 cases and 23 000 controls. Twenty studies have already shared the original data set. Of the patients, 40% are from Asia, 43% from Europe, and 17% from North America; 34% are women and 66% men; the median age is 61 years; 56% are from population-based case-control studies, 41% from hospital-based ones, and 3% from nested case-control studies derived from cohort investigations. Biological samples are available from 12 studies. The aim of the StoP Project is to analyze the role of lifestyle and genetic determinants in the etiology of gastric cancer through pooled analyses of individual-level data. The uniquely large data set will allow us to define and quantify the main effects of each risk factor of interest, including a number of infrequent habits, and to adequately address associations in subgroups of the population, as well as interaction within and between environmental and genetic factors. Further, we will carry out separate analyses according to different histotypes and subsites of gastric cancer, to identify potential different risk patterns and etiological characteristics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: As no curative treatment for advanced pancreatic and biliary cancer with malignant ascites exists, new modalities possibly improving the response to available chemotherapies must be explored. This phase I study assesses the feasibility, tolerability and pharmacokinetics of a regional treatment of gemcitabine administered in escalating doses by the stop-flow approach to patients with advanced abdominal malignancies (adenocarcinoma of the pancreas, n = 8, and cholangiocarcinoma of the liver, n = 1). EXPERIMENTAL DESIGN: Gemcitabine at 500, 750 and 1,125 mg/m(2) was administered to three patients at each dose level by loco-regional chemotherapy, using hypoxic abdominal stop-flow perfusion. This was achieved by an aorto-caval occlusion by balloon catheters connected to an extracorporeal circuit. Gemcitabine and its main metabolite 2',2'-difluorodeoxyuridine (dFdU) concentrations were measured by high performance liquid chromatography with UV detection in the extracorporeal circuit during the 20 min of stop-flow perfusion, and in peripheral plasma for 420 min. Blood gases were monitored during the stop-flow perfusion and hypoxia was considered stringent if two of the following endpoints were met: pH </= 7.2, pO(2) nadir ratio </=0.70 or pCO(2) peak ratio >/=1.35. The tolerability of this procedure was also assessed. RESULTS: Stringent hypoxia was achieved in four patients. Very high levels of gemcitabine were rapidly reached in the extracorporeal circuit during the 20 min of stop-flow perfusion, with C (max) levels in the abdominal circuit of 246 (+/-37%), 2,039 (+/-77%) and 4,780 (+/-7.3%) mug/ml for the three dose levels 500, 750 and 1,125 mg/m(2), respectively. These C (max) were between 13 (+/-51%) and 290 (+/-12%) times higher than those measured in the peripheral plasma. Similarly, the abdominal exposure to gemcitabine, calculated as AUC(t0-20), was between 5.5 (+/-43%) and 200 (+/-66%)-fold higher than the systemic exposure. Loco-regional exposure to gemcitabine was statistically higher in presence of stringent hypoxia (P < 0.01 for C (max) and AUC(t0-20), both normalised to the gemcitabine dose). Toxicities were acceptable considering the complexity of the procedure and were mostly hepatic; it was not possible to differentiate the respective contributions of systemic and regional exposures. A significant correlation (P < 0.05) was found between systemic C (max) of gemcitabine and the nadir of both leucocytes and neutrophils. CONCLUSIONS: Regional exposure to gemcitabine-the current standard drug for advanced adenocarcinoma of the pancreas-can be markedly enhanced using an optimised hypoxic stop-flow perfusion technique, with acceptable toxicities up to a dose of 1,125 mg/m(2). However, the activity of gemcitabine under hypoxic conditions is not as firmly established as that of other drugs such as mitomycin C, melphalan or tirapazamine. Further studies of this investigational modality, but with bioreductive drugs, are therefore warranted first to evaluate the tolerance in a phase I study and later on to assess whether it does improve the response to chemotherapy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this note we prove an existence and uniqueness result for the solution of multidimensional stochastic delay differential equations with normal reflection. The equations are driven by a fractional Brownian motion with Hurst parameter H > 1/2. The stochastic integral with respect to the fractional Brownian motion is a pathwise Riemann¿Stieltjes integral.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We consider the Cauchy problem for a stochastic delay differential equation driven by a fractional Brownian motion with Hurst parameter H>¿. We prove an existence and uniqueness result for this problem, when the coefficients are sufficiently regular. Furthermore, if the diffusion coefficient is bounded away from zero and the coefficients are smooth functions with bounded derivatives of all orders, we prove that the law of the solution admits a smooth density with respect to Lebesgue measure on R.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Plant growth is tightly controlled through the integration of environmental cues with the physiological status of the seedling. A recent study now proposes a model explaining how the plant hormone ethylene triggers opposite growth responses depending on the light environment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To evaluate the feasibility of intravoxel incoherent motion (IVIM) perfusion measurements in the brain with currently available imaging systems. MATERIALS AND METHODS: We acquired high in-plane resolution (1.2 × 1.2 mm(2) ) diffusion-weighted images with 16 different values of b ranging from 0 to 900 s/mm(2) , in three orthogonal directions, on 3T systems with a 32-multichannel receiver head coil. IVIM perfusion maps were extracted by fitting a double exponential model of signal amplitude decay. Regions of interest were drawn in pathological and control regions, where IVIM perfusion parameters were compared to the corresponding dynamic susceptibility contrast (DSC) parameters. RESULTS: Hyperperfusion was found in the nonnecrotic or cystic part of two histologically proven glioblastoma multiforme and in two histologically proven glioma WHO grade III, as well as in a brain metastasis of lung adenocarcinoma, in a large meningioma, and in a case of ictal hyperperfusion. A monoexponential decay was found in a territory of acute ischemia, as well as in the necrotic part of a glioblastoma. The IVIM perfusion fraction f correlated well with DSC CBV. CONCLUSION: Our initial report suggests that high-resolution brain perfusion imaging is feasible with IVIM in the current clinical setting. J. Magn. Reson. Imaging 2014;39:624-632. © 2013 Wiley Periodicals, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Relaxation rates provide important information about tissue microstructure. Multi-parameter mapping (MPM) estimates multiple relaxation parameters from multi-echo FLASH acquisitions with different basic contrasts, i.e., proton density (PD), T1 or magnetization transfer (MT) weighting. Motion can particularly affect maps of the apparent transverse relaxation rate R2(*), which are derived from the signal of PD-weighted images acquired at different echo times. To address the motion artifacts, we introduce ESTATICS, which robustly estimates R2(*) from images even when acquired with different basic contrasts. ESTATICS extends the fitted signal model to account for inherent contrast differences in the PDw, T1w and MTw images. The fit was implemented as a conventional ordinary least squares optimization and as a robust fit with a small or large confidence interval. These three different implementations of ESTATICS were tested on data affected by severe motion artifacts and data with no prominent motion artifacts as determined by visual assessment or fast optical motion tracking. ESTATICS improved the quality of the R2(*) maps and reduced the coefficient of variation for both types of data-with average reductions of 30% when severe motion artifacts were present. ESTATICS can be applied to any protocol comprised of multiple 2D/3D multi-echo FLASH acquisitions as used in the general research and clinical setting.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Diffusion-weighting in magnetic resonance imaging (MRI) increases the sensitivity to molecular Brownian motion, providing insight in the micro-environment of the underlying tissue types and structures. At the same time, the diffusion weighting renders the scans sensitive to other motion, including bulk patient motion. Typically, several image volumes are needed to extract diffusion information, inducing also inter-volume motion susceptibility. Bulk motion is more likely during long acquisitions, as they appear in diffusion tensor, diffusion spectrum and q-ball imaging. Image registration methods are successfully used to correct for bulk motion in other MRI time series, but their performance in diffusion-weighted MRI is limited since diffusion weighting introduces strong signal and contrast changes between serial image volumes. In this work, we combine the capability of free induction decay (FID) navigators, providing information on object motion, with image registration methodology to prospectively--or optionally retrospectively--correct for motion in diffusion imaging of the human brain. Eight healthy subjects were instructed to perform small-scale voluntary head motion during clinical diffusion tensor imaging acquisitions. The implemented motion detection based on FID navigator signals is processed in real-time and provided an excellent detection performance of voluntary motion patterns even at a sub-millimetre scale (sensitivity≥92%, specificity>98%). Motion detection triggered an additional image volume acquisition with b=0 s/mm2 which was subsequently co-registered to a reference volume. In the prospective correction scenario, the calculated motion-parameters were applied to perform a real-time update of the gradient coordinate system to correct for the head movement. Quantitative analysis revealed that the motion correction implementation is capable to correct head motion in diffusion-weighted MRI to a level comparable to scans without voluntary head motion. The results indicate the potential of this method to improve image quality in diffusion-weighted MRI, a concept that can also be applied when highest diffusion weightings are performed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Portable (roll-out) stop signs are used at school crossings in over 300 cities in Iowa. Their use conforms to the Code of Iowa, although it is not consistent with the provisions of the Manual on Uniform Traffic Control Devices adopted for nationwide application. A survey indicated that most users in Iowa believe that portable stop signs provide effective protection at school crossings, and favor their continued use. Other non-uniform signs that fold or rotate to display a STOP message only during certain hours are used at school crossings in over 60 cities in Iowa. Their use does not conform to either the Code of Iowa or the Manual on Uniform Traffic Control Devices. Users of these devices also tend to favor their continued use. A survey of other states indicated that use of temporary devices similar to those used in Iowa is not generally sanctioned. Some unsanctioned use apparently occurs in several states, however. A different type of portable stop sign for school crossings is authorized and widely used in one state. Portable stop signs similar to those used in Iowa are authorized in another state, although their use is quite limited. A few reports in the literature reviewed for this research discussed the use of portable stop signs. The authors of these reports uniformly recommended against the use of portable or temporary traffic control devices. Various reasons for this recommendation were given, although data to support the recommendation were not offered. As part of this research, field surveys were conducted at 54 locations in 33 communities where temporary stop control devices were in use at school crossings. Research personnel observed the obedience to stop control and measured the vehicular delay incurred. Stopped delay averaged 1.89 seconds/entering vehicle. Only 36.6 percent of the vehicles were observed to come to a complete stop at the study locations controlled by temporary stop control devices. However, this level of obedience does not differ from that observed at intersections controlled by permanent stop signs. Accident experience was compiled for 76 intersections in 33 communities in Iowa where temporary stop signs were used and, for comparative purposes, at 76 comparable intersections having other forms of control or operating without stop control. There were no significant differences in accident experience An economic analysis of vehicle operating costs, delay costs, and other costs indicated that temporary stop control generated costs only about 12 percent as great as permanent stop control for a street having a school crossing. Midblock pedestrian-actuated signals were shown to be cost effective in comparison with temporary stop signs under the conditions of use assumed. Such signals could be used effectively at a number of locations where temporary stop signs are being used. The results of this research do not provide a basis for recommending that use of portable stop signs be prohibited. However, erratic patterns of use of these devices and inadequate designs suggest that improved standards for their use are needed. Accordingly, nine recommendations are presented to enhance the efficiency of vehicular flow at school crossings, without causing a decline in the level of pedestrian protection being afforded.