954 resultados para Shoulder injuries


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dr. Narakas intended to study a series of 61 cases of shoulder sequelae of obstetric palsy. His vast experience would have enriched our clinical knowledge of this ailment. The authors carry on with that study to clarify his therapeutic approach and share the benefit of his experience.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Accurate assessment of glenoid inclination is of interest for a variety of conditions and procedures. The purpose of this study was to develop an accurate and reproducible measurement for glenoid inclination on standardized anterior-posterior (AP) radiographs and on computed tomography (CT) images. MATERIALS AND METHODS: Three consistently identifiable angles were defined: Angle α by line AB connecting the superior and inferior glenoid tubercle (glenoid fossa) and the line identifying the scapular spine; angle β by line AB and the floor of the supraspinatus fossa; angle γ by line AB and the lateral margin of the scapula. Experimental study: these 3 angles were measured in function of the scapular position to test their resistance to rotation. Conventional AP radiographs and CT scans were acquired in extension/flexion and internal/external rotation in a range up to ±40°. Clinical study: the inter-rater reliability of all angles was assessed on AP radiographs and CT scans of 60 patients (30 with proximal humeral fractures, 30 with osteoarthritis) by 2 independent observers. RESULTS: The experimental study showed that angle α and β have a resistance to rotation of up to ±20°. The deviation from neutral position was not more than ±10°. The results for the inter-rater reliability analyzed by Bland-Altman plots for the angle β fracture group were (mean ± standard deviation) -0.1 ± 4.2 for radiographs and -0.3 ± 3.3 for CT scans; and for the osteoarthritis group were -1.2 ± 3.8 for radiographs and -3.0 ± 3.6 for CT scans. CONCLUSION: Angle β is the most reproducible measurement for glenoid inclination on conventional AP radiographs, providing a resistance to positional variability of the scapula and a good inter-rater reliability.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The combined action of nisin and lactacin F, two bacteriocins produced by lactic acid bacteria, is additive. In this report, the basis of this effect is examined. Channels formed by lactacin F were studied by experiments using planar lipid bilayers, and bactericidal effects were analyzed by flow cytometry. Lactacin F produced pores with a conductance of 1 ns in black lipid bilayers in 1 mM KClat 10 mV at 20°C. Pore formation was strongly dependent on voltage. Although lactacin F formed pores at very low potential (10 mV), the dependence was exponentialabov e 40 mV. The injuries induced by nisin and lactacin F in the membranes of Lactobacillus helveticus produced different flow cytometric profiles. Probably, when both bacteriocins are present, each acts separately; their cooperation may be due to an increase in the number of single membrane injuries

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In cases of ligature strangulation, the importance of distinguishing self-inflicted death from homicide is crucial. This entails objective scene investigation, autopsy and anamnesis in order to elucidate the manner of death correctly. The authors report a case of unplanned complex suicide by means of self-strangulation and multiple sharp force injury. The use of more than one suicide method, consecutively--termed unplanned complex suicide--gives this case particular significance. A brief discussion on this uncommon method of suicide is presented, particularly relevant to the attending forensic physician. In addition, a short overview of the entity of complex suicide is given.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Between 1976 and 1991, we observed lesions of the small bowel or colon in 39 patients having sustained blunt abdominal trauma. 70% of the patients presented with concomitant injuries. Except for 3 cases, all the patients presented with abdominal pain on admission. All the patients were operated on. The delay between admission and operation varied between a few minutes and 48 hours. Indication was hemoperitoneum, peritonitis or progressive abdominal pain. Overall morbidity is high, often related to associated disease. 4 patients died (mortality 10%), including 2 patients with isolated intestinal trauma who were operated on after 20 and 36 hours. Due to the lack of specific laboratory or X-ray test, we suggest a high index of suspicion for bowel lesions in blunt abdominal trauma, especially in unconscious patients. Close observation is mandatory. Indication for laparotomy must not be delayed if any doubt exists regarding the integrity of hollow viscus.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIM: The aim of our study was to compare traumatic injuries observed after cardiopulmonary resuscitation (CPR) by means of standard (manual) or assisted (mechanical) chest compression by Lund University Cardiopulmonary Assist System, 2nd generation (LUCAS?2) device. METHODS: A retrospective study was conducted including cases from 2011 to 2013, analysing consecutive autopsy reports in two groups of patients who underwent medicolegal autopsy after unsuccessful CPR. We focused on traumatic injuries from dermal to internal trauma, collecting data according to a standardised protocol. RESULTS: The study group was comprised of 26 cases, while 32 cases were included in the control group. Cardiopulmonary resuscitation performed by LUCAS?2 was longer than manual CPR performed in control cases (study group: mean duration 51.5 min; controls 29.4 min; p = 0.004). Anterior chest lesions (from bruises to abrasions) were described in 18/26 patients in the LUCAS?2 group and in 6/32 of the control group. A mean of 6.6 rib fractures per case was observed in the LUCAS?2 group, but this was only 3.1 in the control group (p = 0.007). Rib fractures were less frequently observed in younger patients. The frequency of sternal factures was similar in both groups. A few trauma injuries to internal organs (mainly cardiac, pulmonary and hepatic bruises), and some petechiae (study 46 %; control 41 %; p = 0.79) were recorded in both groups. CONCLUSION: LUCAS?2-CPR is associated with more rib fractures than standard CPR. Typical round concentric skin lesions were observed in cases of mechanical reanimation. No life-threatening injuries were reported. Petechiae were common findings.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: The impacts of humeral offset and stem design after reverse shoulder arthroplasty (RSA) have not been well-studied, particularly with regard to newer stems which have a lower humeral inclination. The purpose of this study was to analyze the effect of different humeral stem designs on range of motion and humeral position following RSA. METHODS: Using a three-dimensional computer model of RSA, a traditional inlay Grammont stem was compared to a short curved onlay stem with different inclinations (155°, 145°, 135°) and offset (lateralised vs medialised). Humeral offset, the acromiohumeral distance (AHD), and range of motion were evaluated for each configuration. RESULTS: Altering stem design led to a nearly 7-mm change in humeral offset and 4 mm in the AHD. Different inclinations of the onlay stems had little influence on humeral offset and larger influence on decreasing the AHD. There was a 10° decrease in abduction and a 5° increase in adduction between an inlay Grammont design and an onlay design with the same inclination. Compared to the 155° model, the 135° model improved adduction by 28°, extension by 24° and external rotation of the elbow at the side by 15°, but led to a decrease in abduction of 9°. When the tray was placed medially, on the 145° model, a 9° loss of abduction was observed. CONCLUSIONS: With varus inclination prostheses (135° and 145°), elevation remains unchanged, abduction slightly decreases, but a dramatic improvement in adduction, extension and external rotation with the elbow at the side are observed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

NlmCategory="UNASSIGNED">This study is aimed at the determination of the measurement properties of the shoulder function B-B Score measured with a smartphone. This score measures the symmetry between sides of a power-related metric for two selected movements, with 100% representing perfect symmetry. Twenty healthy participants, 20 patients with rotator cuff conditions, 23 with fractures, 22 with capsulitis, and 23 with shoulder instabilities were measured twice across a six-month interval using the B-B Score and shoulder function questionnaires. The discriminative power, responsiveness, diagnostic power, concurrent validity, minimal detectable change (MDC), minimal clinically important improvement (MCII), and patient acceptable symptom state (PASS) were evaluated. Significant differences with the control group and significant baseline-six-month differences were found for the rotator cuff condition, fracture, and capsulitis patient groups. The B-B Score was responsive and demonstrated excellent diagnostic power, except for shoulder instability. The correlations with clinical scores were generally moderate to high, but lower for instability. The MDC was 18.1%, the MCII was 25.2%, and the PASS was 77.6. No floor effect was observed. The B-B Score demonstrated excellent measurement properties in populations with rotator cuff conditions, proximal humerus fractures, and capsulitis, and can thus be used as a routine test to evaluate those patients.