937 resultados para Robot Calibration
Resumo:
Desarrollo de un sistema robótico auxiliar de limpieza autónomo en movimiento, conectado a una red wireless, dotado de un sistema de protección contra la perdida de conexión.
Resumo:
The main objective of this master's thesis is to study robot programming using simulation software, and also how to embed the simulation software into company's own robot controlling software. The further goal is to study a new communication interface to the assembly line's components -more precisely how to connect the robot cell into this new communication system. Conveyor lines are already available where the conveyors use the new communication standard. The robot cell is not yet capable of communicating with to other devices using the new communication protocols. The main problem among robot manufacturers is that they all have their own communication systems and programming languages. There has not been any common programming language to program all the different robot manufacturers robots, until the RRS (Realistic Robot Simulation) standards were developed. The RRS - II makes it possible to create the robot programs in the simulation software and it gives a common user interface for different robot manufacturers robots. This thesis will present the RRS - II standard and the robot manufacturers situation for the RRS - II support. Thesis presents how the simulation software can be embedded into company's own robot controlling software and also how the robot cell can be connected to the CAMX (Computer Aided Manufacturing using XML) communication system.
Resumo:
Intravascular brachytherapy with beta sources has become a useful technique to prevent restenosis after cardiovascular intervention. In particular, the Beta-Cath high-dose-rate system, manufactured by Novoste Corporation, is a commercially available 90Sr 90Y source for intravascular brachytherapy that is achieving widespread use. Its dosimetric characterization has attracted considerable attention in recent years. Unfortunately, the short ranges of the emitted beta particles and the associated large dose gradients make experimental measurements particularly difficult. This circumstance has motivated the appearance of a number of papers addressing the characterization of this source by means of Monte Carlo simulation techniques.
Resumo:
L’objectiu del treball és emular virtualment l’entorn de treball del robot Stäubli Tx60 quehi ha al laboratori de robòtica de la UdG (dins les possibilitats que ofereix el software adquirit).Aquest laboratori intenta reproduir un entorn industrial de treball en el qual es realitzal’assemblatge d’un conjunt de manera cent per cent automatitzada.En una primera fase, s’ha dissenyat en tres dimensions tot l’entorn de treball que hi hadisponible al laboratori a través del software CAD SolidWorks. Cada un dels conjuntsque conformen l’estació de treball s’ha dissenyat de manera independent.Posteriorment s’introdueixen tots els elements dissenyats dins el software StäubliRobotics Suite 2013. Amb tot l’anterior, cal remarcar que l’objectiu principal del treball consta de duesetapes. Inicialment es dissenya el model 3D de l’entorn de treball a través del software SolidWorks i s’introdueix dins el software Stäubli Robotics Suite 2013. Enuna segona etapa, es realitza un manual d’ús del nou software de robòtica
Resumo:
Chemical analysis is a well-established procedure for the provenancing of archaeological ceramics. Various analytical techniques are routinely used and large amounts of data have been accumulated so far in data banks. However, in order to exchange results obtained by different laboratories, the respective analytical procedures need to be tested in terms of their inter-comparability. In this study, the schemes of analysis used in four laboratories that are involved in archaeological pottery studies on a routine basis were compared. The techniques investigated were neutron activation analysis (NAA), X-ray fluorescence analysis (XRF), inductively coupled plasma optical emission spectrometry (ICP-OES) and inductively coupled plasma mass spectrometry (ICP-MS). For this comparison series of measurements on different geological standard reference materials (SRM) were carried out and the results were statistically evaluated. An attempt was also made towards the establishment of calibration factors between pairs of analytical setups in order to smooth the systematic differences among the results.
Resumo:
Creació d’un sistema format per un algoritme genètic que permeti dissenyar de forma automática, les dades dels valors lingüístics d’un controlador fuzzy, per a un robot amb tracció diferencial. Les dades que s’han d’obtenir han de donar-li al robot, la capacitat d’arribar a un destí, evitant els obstacles que vagi trobant al llarg del camí
Resumo:
A thorough literature review about the current situation on the implementation of eye lens monitoring has been performed in order to provide recommendations regarding dosemeter types, calibration procedures and practical aspects of eye lens monitoring for interventional radiology personnel. Most relevant data and recommendations from about 100 papers have been analysed and classified in the following topics: challenges of today in eye lens monitoring; conversion coefficients, phantoms and calibration procedures for eye lens dose evaluation; correction factors and dosemeters for eye lens dose measurements; dosemeter position and influence of protective devices. The major findings of the review can be summarised as follows: the recommended operational quantity for the eye lens monitoring is H p (3). At present, several dosemeters are available for eye lens monitoring and calibration procedures are being developed. However, in practice, very often, alternative methods are used to assess the dose to the eye lens. A summary of correction factors found in the literature for the assessment of the eye lens dose is provided. These factors can give an estimation of the eye lens dose when alternative methods, such as the use of a whole body dosemeter, are used. A wide range of values is found, thus indicating the large uncertainty associated with these simplified methods. Reduction factors from most common protective devices obtained experimentally and using Monte Carlo calculations are presented. The paper concludes that the use of a dosemeter placed at collar level outside the lead apron can provide a useful first estimate of the eye lens exposure. However, for workplaces with estimated annual equivalent dose to the eye lens close to the dose limit, specific eye lens monitoring should be performed. Finally, training of the involved medical staff on the risks of ionising radiation for the eye lens and on the correct use of protective systems is strongly recommended.
Resumo:
Following their detection and seizure by police and border guard authorities, false identity and travel documents are usually scanned, producing digital images. This research investigates the potential of these images to classify false identity documents, highlight links between documents produced by a same modus operandi or same source, and thus support forensic intelligence efforts. Inspired by previous research work about digital images of Ecstasy tablets, a systematic and complete method has been developed to acquire, collect, process and compare images of false identity documents. This first part of the article highlights the critical steps of the method and the development of a prototype that processes regions of interest extracted from images. Acquisition conditions have been fine-tuned in order to optimise reproducibility and comparability of images. Different filters and comparison metrics have been evaluated and the performance of the method has been assessed using two calibration and validation sets of documents, made up of 101 Italian driving licenses and 96 Portuguese passports seized in Switzerland, among which some were known to come from common sources. Results indicate that the use of Hue and Edge filters or their combination to extract profiles from images, and then the comparison of profiles with a Canberra distance-based metric provides the most accurate classification of documents. The method appears also to be quick, efficient and inexpensive. It can be easily operated from remote locations and shared amongst different organisations, which makes it very convenient for future operational applications. The method could serve as a first fast triage method that may help target more resource-intensive profiling methods (based on a visual, physical or chemical examination of documents for instance). Its contribution to forensic intelligence and its application to several sets of false identity documents seized by police and border guards will be developed in a forthcoming article (part II).
Resumo:
Durante toda la evolución de la tecnología, se han empleado aparatos interconexionados por cables. Los cables limitan la libertad de movimiento del usuario y pueden captar interferencias entre ellos si la red de cableado es elevada. Mientras avanzaba la tecnología inalámbrica, se ha ido adaptando al equipamiento electrónico a la vez que se iban haciendo cada vez más pequeños. Por esto, se impone la necesidad de utilizarlos como controles a distancia sin el empleo de cables debido a los inconvenientes que estos conllevan. El presente trabajo, pretende unificar tres tecnologías que pueden tener en el futuro una gran afinidad. · Dispositivos basados en el sistema Android. Desde sus inicios, han tenido una evolución meteórica. Se han ido haciendo cada vez más rápidos y mejores. · Sistemas inalámbricos. Los sistemas wifi o bluetooth, se han ido incorporando a nuestras vidas cada vez más y están prácticamente en cualquier aparato. · Robótica. Cualquier proceso de producción incorpora un robot. Son necesarios para hacer muchos trabajos que, aunque el hombre lo puede realizar, un robot reduce los tiempos y la peligrosidad de los procesos. Aunque las dos primeras tecnologías van unidas, ¿quién no tiene un teléfono con conexión wifi y bluetooth?, pocos diseños aúnan estos campos con la Robótica. El objetivo final de este trabajo es realizar una aplicación en Android para el control remoto de un robot, empleando el sistema de comunicación inalámbrico. La aplicación desarrollada, permite controlar el robot a conveniencia del usuario en un entorno táctil/teledirigido. Gracias a la utilización de simulador en ambos lenguajes (RAPID y Android), ha sido posible realizar la programación sin tener que estar presente ante el robot objeto de este trabajo. A través de su progreso, se ha ido evolucionando en la cantidad de datos enviados al robot y complejidad en su procesamiento, a la vez que se ha mejorado en la estética de la aplicación. Finalmente se usó la aplicación desarrollada con el robot, consiguiendo con éxito que realizara los movimientos que eran enviados con la tablet programada.
Resumo:
Objective The authors have sought to study the calibration of a clinical PKA meter (Diamentor E2) and a calibrator for clinical meters (PDC) in the Laboratory of Ionizing Radiation Metrology at Instituto de Energia e Ambiente - Universidade de São Paulo. Materials and Methods Different qualities of both incident and transmitted beams were utilized in conditions similar to a clinical setting, analyzing the influence from the reference dosimeter, from the distance between meters, from the filtration and from the average beam energy. Calibrations were performed directly against a standard 30 cm3 cylindrical chamber or a parallel-plate monitor chamber, and indirectly against the PDC meter. Results The lowest energy dependence was observed for transmitted beams. The cross calibration between the Diamentor E2 and the PDC meters, and the PDC presented the greatest propagation of uncertainties. Conclusion The calibration coefficient of the PDC meter showed to be more stable with voltage, while the Diamentor E2 calibration coefficient was more variable. On the other hand, the PDC meter presented greater uncertainty in readings (5.0%) than with the use of the monitor chamber (3.5%) as a reference.
Resumo:
La idea del proyecto viene del concepto de “fábricas del futuro”, donde las barreras entre robots y humanos se rompen para que la colaboración entre ambos sea como en un equipo. Para la realización de este proyecto se ha utilizado el brazo robótico IRB120 de la marca ABB de 6 Grados de libertad, Matlab y el software Robot Studio. El Objetivo principal de este proyecto es establecer el protocolo de comunicación trabajador-robot mediante imágenes. El trabajador debería poder controlar el robot mediante dibujos realizados en la mesa de trabajo. En el desarrollo de la comunicación trabajador-robot cabe distinguir tres partes: · El análisis y tratamiento de imágenes para el cual se ha utilizado el software Matlab. · Transmisión de los datos desde Matlab al robot. · Programación de las acciones a realizar por el robot mediante el software “Robot Studio”. Con el protocolo de comunicación desarrollado y las imágenes realizadas por el trabajador el robot es capaz de detectar lo siguiente: · la herramienta que debe utilizar (rotulador, boli o ventosa) · si lo que tiene que dibujar en la mesa de trabajo son puntos o trazo continuo. · la localización de los puntos o del trazo continuo en la mesa de trabajo. Se ha alcanzado el objetivo propuesto con éxito, el protocolo de comunicación trabajador-robot mediante imágenes ha sido establecido. Mediante el análisis y tratamiento de imágenes se puede conseguir la información necesaria para que el robot pueda ejecutar las acciones requeridas por el trabajador.
Resumo:
This paper proposes a calibration method which can be utilized for the analysis of SEM images. The field of application of the developed method is a calculation of surface potential distribution of biased silicon edgeless detector. The suggested processing of the data collected by SEM consists of several stages and takes into account different aspects affecting the SEM image. The calibration method doesn’t pretend to be precise but at the same time it gives the basics of potential distribution when the different biasing voltages applied to the detector.