948 resultados para Reproducibility of results
Resumo:
BACKGROUND: This study examined the reliability of explicit guidelines developed using the RAND-UCLA appropriateness method. METHODS: The appropriateness of over 400 indications for colonoscopy was rated by two multispecialty expert panels (United States and Switzerland). A nine-point scale was used, which was consolidated into three categories of appropriateness: appropriate, uncertain, inappropriate. The distribution of appropriateness ratings between the two panels and the intrapanel and interpanel agreement for categories of appropriateness were calculated for all possible indications. Similar statistics were calculated for a series of 577 primary care patients referred for colonoscopy in Switzerland. RESULTS: Over 80% of all indications (348) could be directly compared. The proportions of indications classified as appropriate, uncertain, or inappropriate were 28.4%, 24.7%, 46.6% and 33.0%, 23.0%, 44.0% for the U.S. and the Swiss panels, respectively. Interpanel agreement was excellent for all the possible indications (kappa value: 0.75) and lower for actual cases (kappa value: 0.51) because of lower agreement for the most frequently encountered indications. CONCLUSIONS: Good agreement between the two sets of criteria was found, pointing to the reliability of the method. Partial disagreement occurred essentially for a few, albeit frequently encountered, indications for use of colonoscopy in cases of uncomplicated lower abdominal pain or constipation.
Resumo:
A new method of measuring joint angle using a combination of accelerometers and gyroscopes is presented. The method proposes a minimal sensor configuration with one sensor module mounted on each segment. The model is based on estimating the acceleration of the joint center of rotation by placing a pair of virtual sensors on the adjacent segments at the center of rotation. In the proposed technique, joint angles are found without the need for integration, so absolute angles can be obtained which are free from any source of drift. The model considers anatomical aspects and is personalized for each subject prior to each measurement. The method was validated by measuring knee flexion-extension angles of eight subjects, walking at three different speeds, and comparing the results with a reference motion measurement system. The results are very close to those of the reference system presenting very small errors (rms = 1.3, mean = 0.2, SD = 1.1 deg) and excellent correlation coefficients (0.997). The algorithm is able to provide joint angles in real-time, and ready for use in gait analysis. Technically, the system is portable, easily mountable, and can be used for long term monitoring without hindrance to natural activities.
Resumo:
We present a silicon chip-based approach for the enhanced sensitivity detection of surface-immobilized fluorescent molecules. Green fluorescent protein (GFP) is bound to the silicon substrate by a disuccinimidyl terephtalate-aminosilane immobilization procedure. The immobilized organic layers are characterized by surface analysis techniques, like ellipsometry, atomic force microscopy (AFM) and X-ray induced photoelectron spectroscopy. We obtain a 20-fold enhancement of the fluorescent signal, using constructive interference effects in a fused silica dielectric layer, deposited before immobilization onto the silicon. Our method opens perspectives to increase by an order of magnitude the fluorescent response of surface immobilized DNA- or protein-based layers for a variety of biosensor applications.
Resumo:
Our aim was to evaluate the role of forced diuresis in improving the diagnostic accuracy of abdominopelvic (18)F-FDG PET. METHODS: Thirty-two patients were enrolled. Besides the presence of known intravesical tumors or undefined renal lesions on the initial PET scan, the inclusion criterion was the appearance of indeterminate or equivocal (18)F-FDG foci that extended along the course of the urinary tract and could not confidently be separated from urinary activity. For each patient, a second abdominopelvic PET study was performed after intravenous injection of 0.5 mg of furosemide per kilogram of body weight (maximum, 40 mg) coupled with parenteral infusion of physiologic saline. RESULTS: Forced diuresis coupled with parenteral hydration eliminated any significant (18)F-FDG activity from the lower urinary tract in 31 (97%) of 32 patients after the bladder had been voided 3 successive times. Twelve intravesical lesions were visualized with outstanding clarity, whereas radiologic suspicion of locally recurrent bladder tumors was ruled out in 3 patients. Among 14 indeterminate or equivocal extravesical foci, 7 were deemed of no clinical value because they disappeared after furosemide challenge, whereas 7 persisting foci were proven to be true-positive PET findings. The performance of (18)F-FDG PET in characterizing 3 renal-space-occupying lesions could not be improved by our protocol. CONCLUSION: Furosemide challenge has the potential to noninvasively resolve the inherent (18)F-FDG contrast handicap in the lower urinary tract.
The international development of the RGHQoL: a quality of life measure for recurrent genital herpes.
Resumo:
This paper describes the international development and psychometric testing of the Recurrent Genital Herpes Quality of Life Questionnaire (RGHQoL), a condition-specific quality of life (QoL) instrument. The theoretical foundation for the measure is the needs-based model of QoL and the content of the instrument was derived from in-depth qualitative interviews with relevant patients in the UK. Versions of the RGHQoL were required for the UK, USA, Italy, Germany, France and Denmark for use in international clinical trials. The results indicate that the final 20 item measure has good reliability, internal consistency and validity for all language versions. A small responsiveness study in Denmark suggested that the measure is sensitive to changes in QoL associated with the initiation of suppression treatment for recurrent genital herpes (RGH). It is concluded that the RGHQoL is a valuable instrument for inclusion in clinical trials. The psychometric properties of the instrument are such that it may also be used to monitor the progress of individual patients.
Resumo:
Obesity has become a major worldwide challenge to public health, owing to an interaction between the Western 'obesogenic' environment and a strong genetic contribution. Recent extensive genome-wide association studies (GWASs) have identified numerous single nucleotide polymorphisms associated with obesity, but these loci together account for only a small fraction of the known heritable component. Thus, the 'common disease, common variant' hypothesis is increasingly coming under challenge. Here we report a highly penetrant form of obesity, initially observed in 31 subjects who were heterozygous for deletions of at least 593 kilobases at 16p11.2 and whose ascertainment included cognitive deficits. Nineteen similar deletions were identified from GWAS data in 16,053 individuals from eight European cohorts. These deletions were absent from healthy non-obese controls and accounted for 0.7% of our morbid obesity cases (body mass index (BMI) >or= 40 kg m(-2) or BMI standard deviation score >or= 4; P = 6.4 x 10(-8), odds ratio 43.0), demonstrating the potential importance in common disease of rare variants with strong effects. This highlights a promising strategy for identifying missing heritability in obesity and other complex traits: cohorts with extreme phenotypes are likely to be enriched for rare variants, thereby improving power for their discovery. Subsequent analysis of the loci so identified may well reveal additional rare variants that further contribute to the missing heritability, as recently reported for SIM1 (ref. 3). The most productive approach may therefore be to combine the 'power of the extreme' in small, well-phenotyped cohorts, with targeted follow-up in case-control and population cohorts.
Resumo:
A procedure using a chirobiotic V column is presented which allows separation of the enantiomers of citalopram and its two N-demethylated metabolites, and of the internal standard, alprenolol, in human plasma. Citalopram, demethylcitalopram and didemethylcitalopram, as well as the internal standard, were recovered from plasma by liquid-liquid extraction. The limits of quantification were found to be 5 ng/ml for each enantiomer of citalopram and demethylcitalopram, and 7.5 ng/ml for each enantiomer of didemethylcitalopram. Inter- and intra-day coefficients of variation varied from 2.4% to 8.6% for S- and R-citalopram, from 2.9% to 7.4% for S- and R-demethylcitalopram, and from 5.6% to 12.4% for S- and R- didemethylcitalopram. No interference was observed from endogenous compounds following the extraction of plasma samples from 10 different patients treated with citalopram. This method allows accurate quantification for each enantiomer and is, therefore, well suited for pharmacokinetic and drug interaction investigations. The presented method replaces a previously described highly sensitive and selective high-performance liquid chromatography procedure using an acetylated 3-cyclobond column which, because of manufactural problems, is no longer usable for the separation of the enantiomers of citalopram and its demethylated metabolites.
Resumo:
OBJECTIVE: To study the correlation between the bacteriological and histopathological findings in placentas from women with suspected or proven chorioamnionitis (CA). METHODS: Over a 1-year period, 376 placentas were prospectively collected and processed for bacteriological and pathological studies in cases of confirmed or suspected maternal or neonatal infection. RESULTS: Histological CA was diagnosed in 26.9% of placentas (101/376), and 27.7% (28/101) of these placentas had positive bacteriological cultures. A monomicrobial culture, mainly represented by Gram-positive cocci and Gram-negative bacilli, was identified in 27% of the positive bacterial cultures. The proportion of positive cultures was higher (p=0.03) when CA was associated with funisitis, as compared with placental samples with early CA. In placentas without histological CA, bacteriological cultures were mostly negative (230/275), although pathogenic bacteria were identified in 16.3% of them (45/275). CONCLUSIONS: The histological and bacteriological results were concordant in about 70% of the examined placentas, with 61.1% negative cases (CA absent and negative bacterial cultures), and only 7.4% placentas with positive histological and bacteriological results. Discordant results (positive histology with negative bacteriology) were obtained in placentas with early CA documented by histology although possibly in relation with antibiotic prophylaxis and the presence of fastidious bacteria. Conversely, negative histology with positive bacteriology could be explained by the presence of an early-stage bacterial infection that has not yet led to detectable microscopic lesions.
Resumo:
Adequate in-vitro training in valved stents deployment as well as testing of the latter devices requires compliant real-size models of the human aortic root. The casting methods utilized up to now are multi-step, time consuming and complicated. We pursued a goal of building a flexible 3D model in a single-step procedure. We created a precise 3D CAD model of a human aortic root using previously published anatomical and geometrical data and printed it using a novel rapid prototyping system developed by the Fab@Home project. As a material for 3D fabrication we used common house-hold silicone and afterwards dip-coated several models with dispersion silicone one or two times. To assess the production precision we compared the size of the final product with the CAD model. Compliance of the models was measured and compared with native porcine aortic root. Total fabrication time was 3 h and 20 min. Dip-coating one or two times with dispersion silicone if applied took one or two extra days, respectively. The error in dimensions of non-coated aortic root model compared to the CAD design was <3.0% along X, Y-axes and 4.1% along Z-axis. Compliance of a non-coated model as judged by the changes of radius values in the radial direction by 16.39% is significantly different (P<0.001) from native aortic tissue--23.54% at the pressure of 80-100 mmHg. Rapid prototyping of compliant, life-size anatomical models with the Fab@Home 3D printer is feasible--it is very quick compared to previous casting methods.
Resumo:
Among numerous magnetic resonance imaging (MRI) techniques, perfusion MRI provides insight into the passage of blood through the brain's vascular network non-invasively. Studying disease models and transgenic mice would intrinsically help understanding the underlying brain functions, cerebrovascular disease and brain disorders. This study evaluates the feasibility of performing continuous arterial spin labeling (CASL) on all cranial arteries for mapping murine cerebral blood flow at 9.4 T. We showed that with an active-detuned two-coil system, a labeling efficiency of 0.82 ± 0.03 was achieved with minimal magnetization transfer residuals in brain. The resulting cerebral blood flow of healthy mouse was 99 ± 26 mL/100g/min, in excellent agreement with other techniques. In conclusion, high magnetic fields deliver high sensitivity and allowing not only CASL but also other MR techniques, i.e. (1)H MRS and diffusion MRI etc, in studying murine brains.
Resumo:
With improved B 0 homogeneity along with satisfactory gradient performance at high magnetic fields, snapshot gradient-recalled echo-planar imaging (GRE-EPI) would perform at long echo times (TEs) on the order of T2*, which intrinsically allows obtaining strongly T2*-weighted images with embedded substantial anatomical details in ultrashort time. The aim of this study was to investigate the feasibility and quality of long TE snapshot GRE-EPI images of rat brain at 9.4 T. When compensating for B 0 inhomogeneities, especially second-order shim terms, a 200 x 200 microm2 in-plane resolution image was reproducibly obtained at long TE (>25 ms). The resulting coronal images at 30 ms had diminished geometric distortions and, thus, embedded substantial anatomical details. Concurrently with the very consistent stability, such GRE-EPI images should permit to resolve functional data not only with high specificity but also with substantial anatomical details, therefore allowing coregistration of the acquired functional data on the same image data set.
Resumo:
PURPOSE: Despite ubiquitous expression of the keratoepithelin (KE) protein encoded by the transforming growth factor beta induced/beta induced gene human clone 3 (TGFBI/BIGH3) gene, corneal dystrophies are restricted to the cornea, and no other tissues are affected. We investigated the role of TGFBI/BIGH3 in Groenouw corneal dystrophies by generating transgenic mice overexpressing TGFBI/BIGH3 containing the R555W mutation. METHODS: Transgenic animals expressing the Groenouw mutation of human TGFBI/BIGH3 were generated using lentiviral vectors. The line expressed TGFBI/BIGH3 containing the R555W mutation under the control of the phosphoglycerate kinase (PGK) promoter. Expression of the transgene was monitored by Southern and western blotting and by RT-PCR. Electroretinogram analysis was performed and four mice were subjected to complete necroscopy. RESULTS: Transgene expression was observed in different organs although without specific expression in the cornea. The overall morphology of the transgenic animals was not severely affected by KE overexpression. However, we observed an age-dependent retinal degeneration both functionally and histologically. Female-specific follicular hyperplasia in the spleen and increased levels of lipofuscin in the adrenal gland were also seen in transgenic animals. CONCLUSIONS: Cellular degeneration in the retina of transgenic animals suggest that perturbation of the transforming growth factor beta (TGFbeta) family regulation may affect photoreceptor survival and may induce possible accelerated aging in several tissues. No corneal phenotype could be observed, probably due to the lack of transgene expression in this tissue.
Resumo:
We propose a method for brain atlas deformation in the presence of large space-occupying tumors, based on an a priori model of lesion growth that assumes radial expansion of the lesion from its starting point. Our approach involves three steps. First, an affine registration brings the atlas and the patient into global correspondence. Then, the seeding of a synthetic tumor into the brain atlas provides a template for the lesion. The last step is the deformation of the seeded atlas, combining a method derived from optical flow principles and a model of lesion growth. Results show that a good registration is performed and that the method can be applied to automatic segmentation of structures and substructures in brains with gross deformation, with important medical applications in neurosurgery, radiosurgery, and radiotherapy.
Resumo:
Summary of results from the FY08 School Library Survey formatted by percentiles (from 25th to 90th percentiles) and student population size groups defined by the Iowa School Library Program Guidelines.
Resumo:
The DRG classification provides a useful tool for the evaluation of hospital care. Indicators such as readmissions and mortality rates adjusted for the hospital Casemix could be adopted in Switzerland at the price of minor additions to the hospital discharge record. The additional information required to build patients histories and to identify the deaths occurring after hospital discharge is detailed.