932 resultados para Region of Alto Douro vinhateiro


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A study was conducted on grass mixtures that included smooth bromegrass (SB) + drooping wild ryegrass (DW), smooth bromegrass + Siberian wild ryegrass (SW) + crested wheatgrass (CW) and smooth bromegrass + Siberian wild ryegrass + drooping wild ryegrass + crested wheatgrass in the alpine region of Qinghai-Tibetan Plateau. The study was conducted from 1998 to 2000 to investigate the effects of N application rates and growing year on herbage dry matter (DM) yield and nutritive values. Herbage DM production increased linearly with N application rates. The effect of N application on DM yields was greater (P < 0.05) in the 2nd and 3rd production years than in the establishment year. Dry matter yields of SB + SW + CW and SB + SW + DW + CW can reach as high as 15 000 kg ha(-1) at 345 kg ha(-1) N rate in the 3rd growing year. With increased N application rates, crude protein (CP) contents and 48 h in sacco DM degradability of grasses increased (P < 0.05). No effect (P > 0.05) of N application was detected on organic matter (OM) and acid detergent fibre (ADF) concentration. It can be concluded that for increased biomass production in the alpine region of the Qinghai-Tibetan Plateau, a minimum of 345 kg N ha(-1) should be applied to grass stands in three split application of 115 kg N ha(-1), in early June, early July and late July

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In the alpine region of the Qinghai-Tibetan Plateau four indigenous perennial grass species Bromus inermis (BI), Elymus sibiricus (ES), Elymus nutans (EN) and Agropyron cristatum (AC) were cultivated as three mixtures with different compositions and seeding rates, BI + EN, BI + ES + AC and BI + ES + EN + AC. From 1998 to 2001 there were three different weeding treatments: never weeded (CK); weeded on three occasions in the first year (1-y) and weeded on three occasions in both the first and second year (2-y) and their effect of grass combination and interactions on sward productivity and persistence was measured. Intense competitive interference by weedy annuals reduced dry matter (DM) yield of the swards. Grass combination significantly affected sward DM yields, leaf area index (LAI) and foliar canopy cover and also species composition DM and LAI, and species plant cover. Interaction between weeding treatments and grass combination was significant for sward DM yield, LAI and canopy cover, but not on species composition for DM, LAI or species plant cover. Grass mixture BI + ES + EN + AC gave the highest sward DM yield and LAI for both weeding and non-weeding treatments. Species ES and EN were competitively superior to the others. Annual weedy forbs must be controlled to obtain productive and stable mixtures of perennial grasses, and germination/emergence is the most important time for removal. Weeding three times (late May, late June and mid-July) in the establishment year is enough to maintain the production and persistence of perennial grass mixtures in the following growing seasons. Extra weeding three times in the second growing year makes only a slight improvement in productivity.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Effects of grazing intensity on leaf photosynthetic rate (Pn), specific leaf area (SLA), individual tiller density, sward leaf area index (LAI), harvested herbage DM, and species composition in grass mixtures (Clinelymus nutans + Bromus inermis, Elymus nutans + Bromus inermis + Agropyron cristatum and Elymus nutans + Clinelymus nutans + Bromus inermis + Agropyron cristatum) were studied in the alpine region of the Tibetan Plateau. Four grazing intensities (GI), expressed as feed utilisation rates (UR) by Tibetan lambs were imposed as follows: (1) no grazing; (2) 30% UR as light grazing; (3) 50% UR as medium grazing; and (4) 70% UR as high grazing. Leaf Pn rate and tiller density of grasses increased (P < 0.05), while sward LAI and harvested herbage DM declined (P < 0.05) with the increments of GI, although no effect of GI on SLA was observed. With increasing GI, Elymus nutans and Clinelymus nutans increased but Bromus inermis and Agropyron cristatum decreased in swards, LAI and DM contribution. Whether being grazed or not, Elymus nutans + Clinelymus nutans + Bromus inermis + Agropyron cristatum was the most productive sward among the grass mixtures. Thus, two well-performed grass species (Elymus nutans and Clinelymus nutans) and the most productive mixture of four species should be investigated further as the new feed resources in the alpine grazing system of the Tibetan Plateau. Light grazing intensity of 30% UR was recommended for these grass mixtures when swards, LAI, herbage DM harvested, and species compatibility were taken into account.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The phase transformation of zirconia from tetragonal to monoclinic is characterized by UV Raman spectroscopy, visible Raman spectroscopy, and XRD. Electronic absorption Of ZrO2 in the UV region makes UV Raman spectroscopy more sensitive at the surface region than XRD or visible Raman spectroscopy. Zirconia changes from the tetragonal phase to the monoclinic phase with calcination temperatures elevated and monoclinic phase is always detected first by UV Raman spectroscopy for the samples calcined at lower temperatures than that by XRD and visible Raman spectroscopy. When the phase of zirconia changes from tetragonal to monoclinic, the slight changes of the phase at very beginning can be detected by UV Raman spectroscopy. UV Raman spectra clearly indicate that the phase transition takes place initially at the surface regions. It is found that the phase change from tetragonal to monoclinic is significantly retarded when amorphous Zr(OH)(4) was agglomerated to bigger particles and the particle agglomeration of amorphous zirconium hydroxide is beneficial to the stabilization of t-ZrO2 phase.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study evaluated different techniques for surgically assisted rapid maxillary expansion (SARME) according to the type of transverse maxillary deficiency using computed tomography (CT). Six adult patients with bilateral transverse maxillary deficiencies underwent SARME. the patients were equally divided into three groups: Group I, maxillary atresia in both the anterior and posterior regions; Group II, greater maxillary atresia in the anterior region; and Group ill, increased maxillary atresia in the posterior region. in Group I, a subtotal Le Fort I osteotomy was used. in Group II, a subtotal Le Fort I osteotomy was used without pterygomaxillary suture disjunction. in Group III, a subtotal Le Fort I osteotomy was used with pterygomaxillary suture disjunction and fixation of the anterior nasal spine with steel wire. the midpalatal suture opening was evaluated preoperatively and immediately after the activation period using CT. for Group I, the opening occurred parallel to midpalatal suture; for Group II, the opening comprised a V-shape with a vertex on the posterior nasal spine; and for Group III, the opening comprised a V-shape with a vertex at the anterior nasal spine. the conclusion was that the SARME technique should be individualized according to the type of transverse maxillary deficiency.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dissertação de Mestrado apresentada à Universidade Fernando Pessoa como parte dos requisitos para obtenção do grau de Mestre em Ciências Empresariais.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In rural Ethiopia, among other things, lack of adequate financial service is considered as the basic problem to alleviate rural poverty and to solve the problem of food insecurity. Commercial banks are restricted to urban centres. Providing rural financial service through RUSACCO to the poor has been proposed as a tool for economic development and for achieving food security. Evidence from research in this regard has been so far scanty, especially in rural Ethiopia. The aims of this study are to analyze the determinants of membership, to identify socioeconomic and demographic factors that influence members’ participation in RUSACCOs and to quantify the impact of RUSACCOs on member households’ food security. The study was conducted in two purposely selected woredas in the Amhara region one from food insecure (Lay Gayint woreda) and the other from food secure (Dejen woreda). Six RUSACCOs were selected randomly from these two woredas. Both qualitative and quantitative data were collected. Key informant interviews, focus group discussions and survey techniques were used to collect primary data. Collected data was then analyzed using mixed methods depending on the nature of data. For quantitative data analysis appropriate statistical models were used. The study result reveals that the number of members in each RUSACCO is very small. However, the majority of non-member respondents are willing to join RUSACCO. Lack of information about the benefits of RUSACCO membership is the main problem why many rural poor do not join RUSACCOs. Members participate in different aspects of the cooperatives, starting from attending general assembly up to board membership. They also participate actively in saving and borrowing activities of RUSACCO. The majority of the respondents believe the RUSACCO is a vital instrument in combating food insecurity. The empirical findings indicate that gender, marital status, occupation, educational level, participation in local leadership and participation in other income generation means determine the decision of rural poor to join a RUSACCO or not. The amount of saving is determined by household head occupation, farming experience and income level. While age of household head, primary occupation, farming experience, date of membership, annual total consumption expenditure, amount of saving and participation in other income generation activities influence members’ amount of borrowing by RUSACCO members. Finally, the study confirms that RUSACCO participation improves household food security. RUSACCO membership has made positive impact on household total consumption expenditure and food expenditure.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Optimally, expanded HIV testing programs should reduce barriers to testing while attracting new and high-risk testers. We assessed barriers to testing and HIV risk among clients participating in mobile voluntary counseling and testing (MVCT) campaigns in four rural villages in the Kilimanjaro Region of Tanzania. METHODS: Between December 2007 and April 2008, 878 MVCT participants and 506 randomly selected community residents who did not access MVCT were surveyed. Gender-specific logistic regression models were used to describe differences in socioeconomic characteristics, HIV exposure risk, testing histories, HIV related stigma, and attitudes toward testing between MVCT participants and community residents who did not access MVCT. Gender-specific logistic regression models were used to describe differences in socioeconomic characteristics, HIV exposure risk, testing histories, HIV related stigma, and attitudes toward testing, between the two groups. RESULTS: MVCT clients reported greater HIV exposure risk (OR 1.20 [1.04 to 1.38] for males; OR 1.11 [1.03 to 1.19] for females). Female MVCT clients were more likely to report low household expenditures (OR 1.47 [1.04 to 2.05]), male clients reported higher rates of unstable income sources (OR 1.99 [1.22 to 3.24]). First-time testers were more likely than non-testers to cite distance to testing sites as a reason for not having previously tested (OR 2.17 [1.05 to 4.48] for males; OR 5.95 [2.85 to 12.45] for females). HIV-related stigma, fears of testing or test disclosure, and not being able to leave work were strongly associated with non-participation in MVCT (ORs from 0.11 to 0.84). CONCLUSIONS: MVCT attracted clients with increased exposure risk and fewer economic resources; HIV related stigma and testing-related fears remained barriers to testing. MVCT did not disproportionately attract either first-time or frequent repeat testers. Educational campaigns to reduce stigma and fears of testing could improve the effectiveness of MVCT in attracting new and high-risk populations.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

On-board image guidance, such as cone-beam CT (CBCT) and kV/MV 2D imaging, is essential in many radiation therapy procedures, such as intensity modulated radiotherapy (IMRT) and stereotactic body radiation therapy (SBRT). These imaging techniques provide predominantly anatomical information for treatment planning and target localization. Recently, studies have shown that treatment planning based on functional and molecular information about the tumor and surrounding tissue could potentially improve the effectiveness of radiation therapy. However, current on-board imaging systems are limited in their functional and molecular imaging capability. Single Photon Emission Computed Tomography (SPECT) is a candidate to achieve on-board functional and molecular imaging. Traditional SPECT systems typically take 20 minutes or more for a scan, which is too long for on-board imaging. A robotic multi-pinhole SPECT system was proposed in this dissertation to provide shorter imaging time by using a robotic arm to maneuver the multi-pinhole SPECT system around the patient in position for radiation therapy.

A 49-pinhole collimated SPECT detector and its shielding were designed and simulated in this work using the computer-aided design (CAD) software. The trajectories of robotic arm about the patient, treatment table and gantry in the radiation therapy room and several detector assemblies such as parallel holes, single pinhole and 49 pinholes collimated detector were investigated. The rail mounted system was designed to enable a full range of detector positions and orientations to various crucial treatment sites including head and torso, while avoiding collision with linear accelerator (LINAC), patient table and patient.

An alignment method was developed in this work to calibrate the on-board robotic SPECT to the LINAC coordinate frame and to the coordinate frames of other on-board imaging systems such as CBCT. This alignment method utilizes line sources and one pinhole projection of these line sources. The model consists of multiple alignment parameters which maps line sources in 3-dimensional (3D) space to their 2-dimensional (2D) projections on the SPECT detector. Computer-simulation studies and experimental evaluations were performed as a function of number of line sources, Radon transform accuracy, finite line-source width, intrinsic camera resolution, Poisson noise and acquisition geometry. In computer-simulation studies, when there was no error in determining angles (α) and offsets (ρ) of the measured projections, the six alignment parameters (3 translational and 3 rotational) were estimated perfectly using three line sources. When angles (α) and offsets (ρ) were provided by Radon transform, the estimation accuracy was reduced. The estimation error was associated with rounding errors of Radon transform, finite line-source width, Poisson noise, number of line sources, intrinsic camera resolution and detector acquisition geometry. The estimation accuracy was significantly improved by using 4 line sources rather than 3 and also by using thinner line-source projections (obtained by better intrinsic detector resolution). With 5 line sources, median errors were 0.2 mm for the detector translations, 0.7 mm for the detector radius of rotation, and less than 0.5° for detector rotation, tilt and twist. In experimental evaluations, average errors relative to a different, independent registration technique were about 1.8 mm for detector translations, 1.1 mm for the detector radius of rotation (ROR), 0.5° and 0.4° for detector rotation and tilt, respectively, and 1.2° for detector twist.

Simulation studies were performed to investigate the improvement of imaging sensitivity and accuracy of hot sphere localization for breast imaging of patients in prone position. A 3D XCAT phantom was simulated in the prone position with nine hot spheres of 10 mm diameter added in the left breast. A no-treatment-table case and two commercial prone breast boards, 7 and 24 cm thick, were simulated. Different pinhole focal lengths were assessed for root-mean-square-error (RMSE). The pinhole focal lengths resulting in the lowest RMSE values were 12 cm, 18 cm and 21 cm for no table, thin board, and thick board, respectively. In both no table and thin board cases, all 9 hot spheres were easily visualized above background with 4-minute scans utilizing the 49-pinhole SPECT system while seven of nine hot spheres were visible with the thick board. In comparison with parallel-hole system, our 49-pinhole system shows reduction in noise and bias under these simulation cases. These results correspond to smaller radii of rotation for no-table case and thinner prone board. Similarly, localization accuracy with the 49-pinhole system was significantly better than with the parallel-hole system for both the thin and thick prone boards. Median localization errors for the 49-pinhole system with the thin board were less than 3 mm for 5 of 9 hot spheres, and less than 6 mm for the other 4 hot spheres. Median localization errors of 49-pinhole system with the thick board were less than 4 mm for 5 of 9 hot spheres, and less than 8 mm for the other 4 hot spheres.

Besides prone breast imaging, respiratory-gated region-of-interest (ROI) imaging of lung tumor was also investigated. A simulation study was conducted on the potential of multi-pinhole, region-of-interest (ROI) SPECT to alleviate noise effects associated with respiratory-gated SPECT imaging of the thorax. Two 4D XCAT digital phantoms were constructed, with either a 10 mm or 20 mm diameter tumor added in the right lung. The maximum diaphragm motion was 2 cm (for 10 mm tumor) or 4 cm (for 20 mm tumor) in superior-inferior direction and 1.2 cm in anterior-posterior direction. Projections were simulated with a 4-minute acquisition time (40 seconds per each of 6 gates) using either the ROI SPECT system (49-pinhole) or reference single and dual conventional broad cross-section, parallel-hole collimated SPECT. The SPECT images were reconstructed using OSEM with up to 6 iterations. Images were evaluated as a function of gate by profiles, noise versus bias curves, and a numerical observer performing a forced-choice localization task. Even for the 20 mm tumor, the 49-pinhole imaging ROI was found sufficient to encompass fully usual clinical ranges of diaphragm motion. Averaged over the 6 gates, noise at iteration 6 of 49-pinhole ROI imaging (10.9 µCi/ml) was approximately comparable to noise at iteration 2 of the two dual and single parallel-hole, broad cross-section systems (12.4 µCi/ml and 13.8 µCi/ml, respectively). Corresponding biases were much lower for the 49-pinhole ROI system (3.8 µCi/ml), versus 6.2 µCi/ml and 6.5 µCi/ml for the dual and single parallel-hole systems, respectively. Median localization errors averaged over 6 gates, for the 10 mm and 20 mm tumors respectively, were 1.6 mm and 0.5 mm using the ROI imaging system and 6.6 mm and 2.3 mm using the dual parallel-hole, broad cross-section system. The results demonstrate substantially improved imaging via ROI methods. One important application may be gated imaging of patients in position for radiation therapy.

A robotic SPECT imaging system was constructed utilizing a gamma camera detector (Digirad 2020tc) and a robot (KUKA KR150-L110 robot). An imaging study was performed with a phantom (PET CT PhantomTM), which includes 5 spheres of 10, 13, 17, 22 and 28 mm in diameter. The phantom was placed on a flat-top couch. SPECT projections were acquired with a parallel-hole collimator and a single-pinhole collimator both without background in the phantom, and with background at 1/10th the sphere activity concentration. The imaging trajectories of parallel-hole and pinhole collimated detectors spanned 180 degrees and 228 degrees respectively. The pinhole detector viewed a 14.7 cm-diameter common volume which encompassed the 28 mm and 22 mm spheres. The common volume for parallel-hole was a 20.8-cm-diameter cylinder which encompassed all five spheres in the phantom. The maneuverability of the robotic system was tested by navigating the detector to trace the flat-top table while avoiding collision with the table and maintaining the closest possible proximity to the common volume. For image reconstruction, detector trajectories were described by radius-of-rotation and detector rotation angle θ. These reconstruction parameters were obtained from the robot base and tool coordinates. The robotic SPECT system was able to maneuver the parallel-hole and pinhole collimated SPECT detectors in close proximity to the phantom, minimizing impact of the flat-top couch on detector to center-of-rotation (COR) distance. In no background case, all five spheres were visible in the reconstructed parallel-hole and pinhole images. In with background case, three spheres of 17, 22 and 28 mm diameter were readily observed with the parallel-hole imaging, and the targeted spheres (22 and 28 mm diameter) were readily observed in the pinhole ROI imaging.

In conclusion, the proposed on-board robotic SPECT can be aligned to LINAC/CBCT with a single pinhole projection of the line-source phantom. Alignment parameters can be estimated using one pinhole projection of line sources. This alignment method may be important for multi-pinhole SPECT, where relative pinhole alignment may vary during rotation. For single pinhole and multi-pinhole SPECT imaging onboard radiation therapy machines, the method could provide alignment of SPECT coordinates with those of CBCT and the LINAC. In simulation studies of prone breast imaging and respiratory-gated lung imaging, the 49-pinhole detector showed better tumor contrast recovery and localization in a 4-minute scan compared to parallel-hole detector. On-board SPECT could be achieved by a robot maneuvering a SPECT detector about patients in position for radiation therapy on a flat-top couch. The robot inherent coordinate frames could be an effective means to estimate detector pose for use in SPECT image reconstruction.