999 resultados para Pavimentos : Pneus : Pressão : Análise experimental
Resumo:
This work presents a theoretical and numerical analysis of structures using frequency selective surfaces applied on patch antennas. The FDTD method is used to determine the time domain reflected fields. Applications of frequency selective surfaces and patch antennas cover a wide area of telecommunications, especially mobile communications, filters and WB antennas. scattering parameters are obteained from Fourier Transformer of transmited and reflected fields in time domain. The PML are used as absorbing boundary condition, allowing the determination of the fields with a small interference of reflections from discretized limit space. Rectangular patches are considered on dielectric layer and fed by microstrip line. Frequency selective surfaces with periodic and quasi-periodic structures are analyzed on both sides of antenna. A literature review of the use of frequency selective surfaces in patch antennas are also performed. Numerical results are also compared with measured results for return loss of analyzed structures. It is also presented suggestions of continuity to this work
Resumo:
Pipeline leak detection is a matter of great interest for companies who transport petroleum and its derivatives, in face of rising exigencies of environmental policies in industrialized and industrializing countries. However, existing technologies are not yet fully consolidated and many studies have been accomplished in order to achieve better levels of sensitivity and reliability for pipeline leak detection in a wide range of flowing conditions. In this sense, this study presents the results obtained from frequency spectrum analysis of pressure signals from pipelines in several flowing conditions like normal flowing, leakages, pump switching, etc. The results show that is possible to distinguish between the frequency spectra of those different flowing conditions, allowing recognition and announce of liquid pipeline leakages from pressure monitoring. Based upon these results, a pipeline leak detection algorithm employing frequency analysis of pressure signals is proposed, along with a methodology for its tuning and calibration. The proposed algorithm and its tuning methodology are evaluated with data obtained from real leakages accomplished in pipelines transferring crude oil and water, in order to evaluate its sensitivity, reliability and applicability to different flowing conditions
Resumo:
The Ethernet technology dominates the market of computer local networks. However, it was not been established as technology for industrial automation set, where the requirements demand determinism and real-time performance. Many solutions have been proposed to solve the problem of non-determinism, which are based mainly on TDMA (Time Division Multiple Access), Token Passing and Master-Slave. This work of research carries through measured of performance that allows to compare the behavior of the Ethernet nets when submitted with the transmissions of data on protocols UDP and RAW Ethernet, as well as, on three different types of Ethernet technologies. The objective is to identify to the alternative amongst the protocols and analyzed Ethernet technologies that offer to a more satisfactory support the nets of the industrial automation and distributed real-time application
Resumo:
From what was stated in the Montreal Protocol, the researchers and refrigeration industry seek substitutes for synthetic refrigerants -chlorofluorocarbons (CFCs) and HCFCs (HCFC) - that contribute to the depletion of the ozone layer. The phase-out of these substances was started using as one of the replacement alternatives the synthetic fluids based on hydro fluorocarbons (HFCs) that have zero potential depletion of the ozone layer. However, contribute to the process of global warming. HFC refrigerants are greenhouse gases and are part of the group of gases whose emissions must be reduced as the Kyoto Protocol says. The hydrocarbons (HC's), for not contribute to the depletion of the ozone layer, because they have very low global warming potential, and are found abundantly in nature, has been presented as an alternative, and therefore, are being used in new home refrigeration equipment in several countries. In Brazil, due to incipient production of domestic refrigerators using HC's, the transition refrigerants remain on the scene for some years. This dissertation deals with an experimental evaluation of the conduct of a drinking fountain designed to work with HFC (R-134a), operating with a mixture of HC's or isobutane (R-600a) without any modification to the system or the lubricating oil. In the refrigeration laboratory of Federal University of Rio Grande do Norte were installed, in a drinking fountain, temperature and pressure sensors at strategic points in the refrigeration cycle, connected to an acquisition system of computerized data, to enable the mapping and thermodynamics analysis of the device operating with R-134a or with a mixture of HC's or with R-600a. The refrigerator-test operating with the natural fluids (mixture of HC's or R-600a) had a coefficient of performance (COP) lower than the R-134a
Resumo:
The great importance in selecting the profile of an aircraft wing concerns the fact that its relevance in the performance thereof; influencing this displacement costs (fuel consumption, flight level, for example), the conditions of flight safety (response in critical condition) of the plane. The aim of this study was to examine the aerodynamic parameters that affect some types of wing profile, based on wind tunnel testing, to determine the aerodynamic efficiency of each one of them. We compared three types of planforms, chosen from considerations about the characteristics of the aircraft model. One of them has a common setup, and very common in laboratory classes to be a sort of standard aerodynamic, it is a symmetrical profile. The second profile shows a conFiguration of the concave-convex type, the third is also a concave-convex profile, but with different implementation of the second, and finally, the fourth airfoil profile has a plano-convex. Thus, three different categories are covered in profile, showing the main points of relevance to their employment. To perform the experiment used a wind tunnel-type open circuit, where we analyzed the pressure distribution across the surface of each profile. Possession of the drag polar of each wing profile can be, from the theoretical basis of this work, the aerodynamic characteristics relate to the expected performance of the experimental aircraft, thus creating a selection model with guaranteed performance aerodynamics. It is believed that the philosophy used in this dissertation research validates the results, resulting in an experimental alternative for reliable implementation of aerodynamic testing in models of planforms
Resumo:
To enhance the maintenance practices, Oil and Gas Pipelines are inspected from the inside by automated systems called PIG (Pipeline Inspection Gauge). The inspection and mapping of defects, as dents and holes, in the internal wall of these pipelines are increasingly put into service toward an overall Structural Integrity Policy. The residual life of these structures must be determined such that minimize its probability of failure. For this reason, the investigation on the detection limits of some basic topological features constituted by peaks or valleys disposed along a smooth surface is of great value for determining the sensitivity of the measurements of defects from some combinations of circumferential, axial and radial extent. In this investigation, it was analyzed an inductive profilometric sensor to scan three races, radius r1, r2, r3, in a circular surface of low carbon steel, equipped with eight consecutive defects simulated by bulges and holes by orbit, equally spaced at p/4 rad. A test rig and a methodology for testing in laboratory were developed to evaluate the sensor response and identify their dead zones and jumps due to fluctuations as a function of topological features and scanning velocity, four speeds different. The results are presented, analyzed and suggestions are made toward a new conception of sensor topologies, more sensible to detect these type of damage morphologies
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
This work aims to determine a better methodology to help predicting some operational parameters to a new design of mixer-settler on treating wastewater produced by petroleum industry, called MDIF (Misturador-Decantador à Inversão de Fases/ Mixer-Settler based on Phase Inversion MSPI). The data from this research were obtained from the wastewater treatment unit, called MSPI-TU, installed on a wastewater treatment plant (WTP) of PETROBRAS/UO-RNCE. The importance in determining the better methodology to predict the results of separation and extraction efficiency of the equipment, contributes significantly to determine the optimum operating variables for the control of the unit. The study was based on a comparison among the experimental efficiency (E) obtained by operating MSPI-TU, the efficiency obtained by experimental design equation (Eplan) from the software Statistica Experimental Design® (version 7.0), and the other obtained from a modeling equation based on a dimensional analysis (Ecalc). The results shows that the experimental design equation gives a good prediction of the unit efficiencies with better data reliability, regarding to the condition before a run operation. The average deviation between the proposed by statistic planning model equation and experimental data was 0.13%. On the other hand, the efficiency calculated by the equation which represents the dimensional analysis, may result on important relative deviations (up 70%). Thus, the experimental design is confirmed as a reliable tool, with regard the experimental data processing of the MSPI-TU
Resumo:
A technological alternative for the correct disposal of tires is the use in the construction of embankment with soil and shredded tires. The use of waste tires in tropical soils requires prior knowledge of the properties and limitations of these materials. In this work, the results of an experimental program was devised to characterize the behavior of mixtures of waste tires and a lateritic soil. The residue used in this study is classified as tire buffings with an average size of 1.4 mm. The laboratory program included testing of particle size analysis, Atterberg limits, compaction, direct shear tests, permeability and confined compression tests with pure soil, pure tire and the mixtures. Proportions of 0% (pure soil), 10%, 20%, 40%, 50 % and 100% (pure tire) by weight were used. For the confining stress levels used in the study, the presence of tire residue provided a considerable increase in shear strength of the mixture. The maximum shear strength was obtained for a residue content of 40% by weight. Permeability tests on samples of waste under a confining stress of 100 kPa showed that the permeability increases significantly with increasing residue content until a residue content of 20%. The increase in permeability after that value showed to be negligible. Confined compression tests showed that the soil mixed with tire residue becomes more compressible than the pure soil. The secant constrained modulus (Msec) for the same vertical stress decreases with increasing percentage of residue.
Resumo:
JUSTIFICATIVA E OBJETIVOS: Estudos introduziram novo método para avaliação da pré-carga, baseado na análise da variação da pressão sistólica (VPS) durante ventilação artificial. O objetivo desta pesquisa é avaliar se a VPS e sua derivada delta down (ddown) são indicadoras precoces de hipovolemia e guias de reposição volêmica com solução hiperosmótica e hiperoncótica. MÉTODO: Doze cães foram submetidos a sangramentos parciais de 5% da volemia até se atingir 20% da volemia (14 ml.kg-1). Antes (controle) e após cada sangramento foram realizadas análises hemodinâmicas, respiratórias e sangüíneas. Após, os cães foram submetidos à reposição com solução de NaCl a 7,5% em dextran 70 a 3,75% (SHD) (4 ml.kg-1) e novas análises dos atributos estudados foram realizadas aos 5 e 30 minutos após a reposição. RESULTADOS: A pressão arterial média diminuiu durante o sangramento e aumentou após a reposição, sem retornar aos valores do controle. As pressões da artéria pulmonar e do átrio direito (PAD) diminuíram antes e aumentaram após a reposição para valores semelhantes aos do controle. A pressão da artéria pulmonar ocluída (PAPO) diminuiu após o primeiro sangramento e manteve-se em valores abaixo aos do controle, mesmo após a reposição. O índice cardíaco não se alterou, mas aumentou após a reposição, para valores superiores aos do controle. O índice sistólico (IS) diminuiu antes e aumentou após a reposição, em níveis superiores aos do controle. Os índices de resistência vascular sistêmica (IRVS) e pulmonar (IRVP) não se alteraram antes, mas diminuíram após a reposição, com o IRVS em níveis inferiores aos do controle, e o IRVP em níveis semelhantes aos do controle. Os índices de trabalho sistólico dos ventrículos direito (ITSVD) e esquerdo (ITSVE) diminuíram durante o sangramento, mas aumentaram após a reposição, com o ITSVD em níveis superiores aos do controle e o ITSVE em níveis semelhantes aos do controle. A VPS e ddown aumentaram progressivamente durante o sangramento e diminuíram após a reposição, mas mantendo-se em valores superiores aos do controle. As maiores correlações de VPS e ddown foram com IS, PAPO, PAD e ITSVE. CONCLUSÕES: No cão, nas condições empregadas, a VPS e sua derivada ddown são indicadoras precoces de hipovolemia e guias sensíveis de reposição volêmica com SHD.
Resumo:
JUSTIFICATIVA E OBJETIVOS: As lesões da mucosa traqueal em contato com o balonete do tubo traqueal são proporcionais à pressão exercida pelo balonete e ao tempo de exposição. O objetivo foi estudar as eventuais lesões da mucosa do segmento traqueal em contato com o balonete do tubo traqueal insuflado com volume de ar suficiente para se obter pressão de "selo" ou com a pressão limite de 25 cmH2O, abaixo da pressão crítica de 30 cm de água para produção de lesão da mucosa traqueal. MÉTODO: Dezesseis cães foram submetidos à anestesia venosa e ventilação artificial. Os cães foram distribuídos aleatoriamente em dois grupos de acordo com a pressão no balonete do tubo traqueal (Portex Blue-Line, Inglaterra): Gselo (n = 8) balonete com pressão mínima de "selo" para impedir vazamento de ar durante a respiração artificial; G25 (n = 8) balonete insuflado até obtenção da pressão de 25 cmH2O. A medida da pressão do balonete foi realizada por meio de manômetro digital no início (controle) e após 60, 120 e 180 minutos. Após o sacrifício dos cães, foram feitas biópsias nas áreas da mucosa traqueal adjacentes ao balonete e ao tubo traqueal para análise à microscopia eletrônica de varredura (MEV). RESULTADOS: A pressão média do balonete em G25 manteve-se entre 24,8 e 25 cmH2O e em Gselo entre 11,9 e 12,5 cmH2O durante o experimento. As alterações à MEV foram pequenas e não significantemente diferentes nos grupos (p > 0,30), mas ocorreram lesões mais intensas nas áreas de contato da mucosa traqueal com o balonete do tubo traqueal, nos dois grupos, em relação às áreas da mucosa adjacentes ou não ao tubo traqueal (p < 0,05). CONCLUSÕES: No cão, nas condições experimentais empregadas, a insuflação do balonete de tubo traqueal em volume de ar suficiente para determinar pressão limite de 25 cmH2O ou de "selo" para impedir vazamento de ar determina lesões mínimas da mucosa traqueal em contato com o balonete e sem diferença significante entre elas.
Resumo:
PURPOSE--To provide a critical analysis of the fluid filled manometric system and M-mode echocardiography and, by their association, to standardize the determination of left ventricular (LV) pressure-diameter and stress-diameter relationships in humans. MATERIAL AND METHODS--The pressure curve and the LV M-mode image was obtained in 24 patients with cardiopathy. The dynamic characteristics of the fluid-filled system have been studied to define the amplitude, the resonance and the time gap of the pressure curve register. The delay of the pressure curve recording was determined in all cases by comparing pressure curve and echocardiographic aortic valve registers. The values of pressure, diameter, posterior wall thickness and LV meridional stress was calculated at every 0.02s. RESULTS--Preliminary analyses of the fluid-filled manometric system indicated that this system has variable dynamic characteristics. The pressure-diameter and stress-diameter loops obtained were similar to those of the literature. The values of end-systolic stress, percentage of fractional shortening, ejection fraction and circumferential fiber shortening rate of patients with dilated cardiomyopathy (n = 5) were significantly reduced when compared to the values of patients without left ventricular overload (n = 8) and patients with ventricular volume overload. It has been verified, also, that the retard of the pressure curve record introduced by the fluid-filled manometric system does not modify the values of these variables. CONCLUSION--The LV pressure-diameter and stress-diameter relationships obtained by the association of echocardiography and LV manometry showed functional characteristics of the ventricle that could not appear by the use of the echocardiography or by the LV manometry themselves.
Resumo:
Objective. To assess factors determining growth in a group of children between 3 months and 6 years old enrolled in a public municipal (i.e., government-supported, not private) day-care center, in comparison to a group of children with similar characteristics but who were not enrolled in the center. Methods. A quasi-experimental study was designed to observe 444 children aged 3 to 72 months from a low-income neighborhood in the city of Sorocaba, in the state of São Paulo, Brazil. Two groups were studied: 164 children enrolled in a local municipal day-care center (intervention group) and 280 not receiving care at the center (nonintervention, comparison group) but instead being cared for at home. Both groups were seen four times over a period of 16 months. At each observation session, the children's weight and height were measured. Information was also collected on the mother's sociodemographic characteristics and the illnesses she had suffered as well as the child's weight and other health characteristics at birth, the child's illnesses in the 15 days before each observation, and any hospitalizations. Results. The children in both groups were from low-income families, with 65% of the families having an average monthly income below US$ 100; 80% of the mothers had received 8 years of schooling or less. Multivariate linear regression analysis showed that at the first observation (just before enrollment in the day-care center), birth weight was the only factor that explained the nutritional differences between the two groups. Subsequent analyses showed that being in day care was the factor that best explained the differences between the groups, especially in terms of the adequacy of weight for age, after controlling for birthweight, sex, age at the beginning of the study, and illnesses in the 15 days before an observation session. The nutritional impact of the intervention was significant as early as 3 months after being enrolled in day care. Conclusions. The nutritional benefits of the care provided at the center outweighed the negative effects sometimes seen in such centers, such as the greater morbidity that children in day-care centers often experience in comparison to children receiving care at home.
Resumo:
Purpose: To study the effects of two drugs (captopril and propranolol) used in the treatment of systemic hypertension, on the intraocular pressure (IOP) of anesthetized dogs. Methods: 24 dogs, divided into 3 groups of 8 each. In the first group, 1.5 mg/kg IV of captopril (an angiotensin converting enzyme inhibitor) was administered. In the second group, 1.5 mg/kg IV of propranolol (a beta-blocker) was administered. The third group was the control. IOP and blood pressure (BP) were measured by manometry. The perfusion pressure was calculated by the difference between BP and IOP (BP-IOP). The parameters were studied at 6 moments (0, 10, 30, 60, 90 and 120 minutes). Results: There was significant reduction of IOP (p<0.05) with captopril and propranolol, without difference between the drugs. With captopril the BP and PP decreased markedly at 10 and 30 minutes. With propranolol there was no reduction of BP or PP. Conclusions: Captopril and propranolol reduced IOP. However, the marked reduction of BP, and consequently of PP caused by captopril may be undesirable for irrigation of the optic nerve.
Resumo:
One of the most often used strategies to study the physiopathological alterations caused by coronary occlusion is the use of the experimental infarction model in rats. Among other factors, this is due to the similarities in the physiopathological alterations that occur after the infarction in humans. One must consider, however, that this model has characteristics that can hinder the use as well as the interpretation of eventual outcomes. Thus, this review aims at analyzing the main characteristics of the experimental infarction model in rats, discussing the coronary occlusion technique, the consequences and the methods of morphological and functional assessment of the infarction and its clinical implications.