875 resultados para POSTERIOR CHAMBER LENSES


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The authors report a case of repetitive locking knee caused by a subluxation of the posterior horn of a normal lateral meniscus. The posterior horn was sutured to the posterior knee capsule and the athlete resumed complete sports activity 4 months after the surgery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To report three cases of posterior vasculitis associated with subacute giant cell arteritis (GCA). METHODS: Three patients with decreased vision underwent complete ophthalmologic examination and fluorescein angiography. RESULTS: All patients presented posterior vasculitis. Patient 1 had an erythrocyte sedimentation rate (ESR) of 38 mm/hr and a C-reactive protein (CRP) of 28mg/L. Patient 2 and 3 had an ESR of 104 and 95 mm/hr and a CRP of 42 and 195 mg/L accordingly. Diagnosis was established by temporal artery biopsy. Resolution was observed after systemic prednisolone therapy. CONCLUSION: GCA should be suspected when posterior vasculitis and relatively high ESR and CRP are present.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sternoclavicular dislocations represent a rare injury. Based on our clinical experience with a patient showing an anterior subluxation after reduction of a posterior traumatic dislocation, we review the literature. The emergent reduction of the dislocation is mandatory, always keeping in mind the potentially devastating neurovascular complications. If the treatment of a residual anterior instability remains controversial, a residual posterior instability should be treated by a surgical procedure. The optimal treatment depends mainly on each surgeon's choice and practice.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In order to study the various health influencing parameters related to engineered nanoparticles as well as to soot emitted b diesel engines, there is an urgent need for appropriate sampling devices and methods for cell exposure studies that simulate the respiratory system and facilitate associated biological and toxicological tests. The objective of the present work was the further advancement of a Multiculture Exposure Chamber (MEC) into a dose-controlled system for efficient delivery of nanoparticles to cells. It was validated with various types of nanoparticles (diesel engine soot aggregates, engineered nanoparticles for various applications) and with state-of-the-art nanoparticle measurement instrumentation to assess the local deposition of nanoparticles on the cell cultures. The dose of nanoparticles to which cell cultures are being exposed was evaluated in the normal operation of the in vitro cell culture exposure chamber based on measurements of the size specific nanoparticle collection efficiency of a cell free device. The average efficiency in delivering nanoparticles in the MEC was approximately 82%. The nanoparticle deposition was demonstrated by Transmission Electron Microscopy (TEM). Analysis and design of the MEC employs Computational Fluid Dynamics (CFD) and true to geometry representations of nanoparticles with the aim to assess the uniformity of nanoparticle deposition among the culture wells. Final testing of the dose-controlled cell exposure system was performed by exposing A549 lung cell cultures to fluorescently labeled nanoparticles. Delivery of aerosolized nanoparticles was demonstrated by visualization of the nanoparticle fluorescence in the cell cultures following exposure. Also monitored was the potential of the aerosolized nanoparticles to generate reactive oxygen species (ROS) (e.g. free radicals and peroxides generation), thus expressing the oxidative stress of the cells which can cause extensive cellular damage or damage on DNA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

En este artículo se señalan las causas que pueden producir una mordida cruzada posterior, se exponen las razones para su corrección precoz, en el período de dentición primaría y en la primera fase de dentición mixta y se mencionan los diferentes medios de tratamiento de que dispone el clínico, indicando cuáles pueden ser más adecuados para esta edad temprana.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To evaluate inter- and intraobserver variability of indices crucial for detection of keratoconus progression derived from the Pentacam HR® (high-resolution) tomographer (OCULUS Optikgeräte GmbH, Wetzlar, Germany) in patients with mild to moderate keratoconus. Methods: Three repeated corneal topography measurements in the 25-picture mode by two independent observers were performed. The extent of variability across a large range of measurement parameters was analyzed including anterior and posterior corneal surface measurements, pachymetry values, corneal volume, anterior chamber volume and depth, and iridocorneal angle. The intraclass correlation coefficient (ICC) between and within each investigator was calculated to assess reproducibility and repeatability, respectively. Results: 31 eyes of 20 patients (mean age 31.6, SD ± 8.6) were included. Overall, the repeatability and reproducibility were excellent. The range of variability was reported by calculating the standard deviation of measurements. The detailed results are shown in Table 1. Conclusions: This study shows that the Pentacam HR® tomographer provides reliable measurements in patients with mild to moderate keratoconus. However, all parameters showed a certain range of variability. This should be taken into account when assessing keratoconus progression in order to distinguish true progression from variability in measurements. In addition, the excellent reproducibility suggests that the measurements can be reliably performed by different individuals from one visit to another.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Intraoperative ultrasound (IOUS) has been described to be useful during central corpectomy for compressive cervical myelopathy. This study aimed at documenting the utility of IOUS in oblique cervical corpectomy (OCC). Prospective data from 24 patients undergoing OCC for cervical spondylotic myelopathy and ossified posterior longitudinal ligament (OPLL) were collected. Patients had a preoperative cervical spine magnetic resonance (MR) image, IOUS and a postoperative cervical CT scan. Retrospective data from 16 historical controls that underwent OCC without IOUS were analysed to compare the incidence of residual compression between the two groups. IOUS identified the vertebral artery in all cases, detected residual cord compression in six (27%) and missed compression in two cases (9%). In another two cases with OPLL, IOUS was sub-optimal due to shadowing. IOUS measurement of the corpectomy width correlated well with these measurements on the postoperative CT. The extent of cord expansion noted on IOUS after decompression showed no correlation with immediate or 6-month postoperative neurological recovery. No significant difference in residual compression was noted in the retrospective and prospective groups of the study. Craniocaudal spinal cord motion was noted after the completion of the corpectomy. IOUS is an inexpensive and simple real-time imaging modality that may be used during OCC for cervical spondylotic myelopathy. It is helpful in identifying the vertebral artery and determining the trajectory of approach, however, it has limited utility in patients with OPLL due to artifacts from residual ossification.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Retinal diseases are nowadays the most common causes of vision threatening in developed countries. Therapeutic advances in this field are hindered by the difficulty to deliver drugs to the posterior segment of the eye. Due to anatomical barriers, the ocular biodisponibility of systemically administered drugs remains poor, and topical instillation is not adequate to achieve therapeutic concentrations of drugs in the back of the eye. Ocular drug delivery has thus become one of the main challenges of modern ophthalmology. A multidisciplinary research is being conducted worldwide including pharmacology, biomaterials, ophthalmology, pharmaceutics, and biology. New promising fields have been developed such as implantable or injectable slow release intravitreal devices and degradable polymers, dispersed polymeric systems for intraocular drug delivery, and transscleral delivery devices such as iontophoresis, osmotic pumps or intra-scleraly implantable materials. The first clinical applications emerging from this research are now taking place, opening new avenues for the treatment of retinal diseases.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Colbertinus

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Eotaxin-1 (CCL11) is a potent eosinophil chemotactic and activating peptide that may be implicated in the pathogenesis of chronic allergic eye disease and has been associated with the wearing of contact lenses (CL) in patients with contact lens papillary conjunctivitis (CLPC). The purpose of this study was to study eotaxin-1 expression in the tears of long-term CL wearers. PATIENTS AND METHODS: Tears were collected with glass capillaries from 15 patients (2 male, 13 female) with various degree of CLPC at 2-year intervals. CLPC severity was graded from 0 to 4 with reference to standard slit-lamp photographs of the superior tarsal conjunctiva. The eotaxin-1 level in the tears was measured by an ELISA, using mouse anti-human eotaxin monoclonal antibodies. RESULTS: The mean age was 32.5 ± 13.3 years (range: 17 - 69 years). The mean interval between the tear collections was 30 ± 4.8 months. The mean concentration of eotaxin was 2150 ± 477 pg/mL and 2486 ± 810 pg/mL for the first and second series, respectively. The difference was not statistically significant (paired Wilcoxon/Kruskal-Wallis, p = 0.803). The mean score of papilla grade was 1.26 ± 0.18 for the first sample and 1.40 ± 0.19 two years later. There was no significant difference of grading between the two time periods (paired Wilcoxon/Kruskal-Wallis, p = 0.751). CONCLUSIONS: the eotaxin-1 level remains up-regulated over a long time period in patients wearing CL, most of them with chronic CLPC. Eotaxin may play a role in the pathogenesis of contact lens intolerance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this paper is to discuss the post-traumatic overload syndrome of the os trigonum as a possible cause of posterior ankle impingement and hindfoot pain. We have reviewed 19 athletes who were referred to our foot unit between 1995 and 2001 because of posterior ankle pain, and in whom a post-traumatic overload syndrome of os trigonum was diagnosed. All these patients were followed up over a period of 2 years. In 11 cases a chronic repetitive movements in forced plantar flexion was found. In the other eight cases the pain appeared to persist after a standard treatment of an ankle sprain in inversion plantar flexion. The diagnosis was based on clinical history, physical examination and X-rays that revealed a non-fused os trigonum. The confirmation of diagnosis was carried-out injecting local anaesthetic under fluoroscopic control. In all cases a corticosteroid injection as first line treatment was performed. In 6 cases a second injection was necessary to alleviate pain because incomplete recovery with the first injection. Three cases (16%) were recalcitrant to this treatment and in these three cases a surgical excision of the os trigonum was carried out. Our conclusion is that after some chronic athletic activity or an acute ankle sprain the os trigonum, if present, may undergo mechanical overload, remain undisrupted and become painful. Treatment by corticosteroid injection often resolves the problem.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In young people, the most frequent cause of isolated monocular visual loss due to an optic neuropathy is optic neuritis. We present the case of a 27 year old woman who presented monocular visual loss, excruciating orbital pain and unusual temporal headache. The initial diagnosis of optic neuritis revealed later to be a posterior ischemic optic neuropathy (PION). In this case, PION was the first unique presentation of a non-traumatic carotid dissection, and it was followed 24h later by an ischemic stroke. Sudden monocular visual loss associated with a new-onset headache are clinical symptoms that should immediately prompt to a carotid dissection.