998 resultados para PASSIVE-MODE-LOCKING
Resumo:
An examination has been carried out of the secondary passive film on Type 304 stainless steel in 0.5 M H2SO4. The characterization techniques used were electrochemical (potentiodynamic; potentiostatic, and film reduction experiments) and surface analytical. A bilayer model for the secondary passive film is proposed. It appears that next to the metal, there is a modified passive film which controls the electrochemical response; i.e., governs the current for any applied potential. On top of this modified passive film, the experimental data are consistent with a ''porous'' corrosion-product film which adds to the total film thickness but has little influence on the electrochemical response. The composition of the secondary passive film corresponds most probably to a mixed Fe/Cr oxide/hydroxide enriched in Cr3+, With a composition similar to a primary passive film.
Resumo:
Although many mathematical models exist predicting the dynamics of transposable elements (TEs), there is a lack of available empirical data to validate these models and inherent assumptions. Genomes can provide a snapshot of several TE families in a single organism, and these could have their demographics inferred by coalescent analysis, allowing for the testing of theories on TE amplification dynamics. Using the available genomes of the mosquitoes Aedes aegypti and Anopheles gambiae, we indicate that such an approach is feasible. Our analysis follows four steps: (1) mining the two mosquito genomes currently available in search of TE families; (2) fitting, to selected families found in (1), a phylogeny tree under the general time-reversible (GTR) nucleotide substitution model with an uncorrelated lognormal (UCLN) relaxed clock and a nonparametric demographic model; (3) fitting a nonparametric coalescent model to the tree generated in (2); and (4) fitting parametric models motivated by ecological theories to the curve generated in (3).
Resumo:
Although acquisition of anti-pertussis antibodies by the newborn via placental transfer has been demonstrated, a subsequent recrudescence of pertussis infection is often observed, particularly in infants. The present study investigated the passive transfer of anti-pertussis IgG and IgA antibodies to term newborns and their ability to neutralize bacterial pathogenicity in an in vivo experimental model using mice intracerebrally challenged with viable Bordetella pertussis. Forty paired samples of maternal/umbilical cord sera and colostrum were obtained. Anti-pertussis antibodies were analysed by immunoenzymatic assay and by Immunoblotting. Antibody neutralizing ability was assessed through intracerebral B. pertussis challenges in mice. Anti-pertussis IgG titres were equivalent in both maternal and newborn sera (medians = 1:225 and 1:265), with a transfer rate of 118%. The colostrum samples had variable specific IgA titres (median = 1:74). The immunoblotting assays demonstrated identical recognition profiles of paired maternal and newborn serum pools but different bacterial recognition intensities by colostrum pools. In the animal model, significant differences were always observed when the serum and colostrum samples and pools were compared with the positive control (P < 0.05). Unlike samples with lower anti-pertussis titres, samples with high titres showed protective capacities above 50%. Pertussis-absorbed serum and colostrum pools protected 30% of mice and purified IgG antibodies protected 65%. Both pooled and single-sample protective abilities were correlated with antibody titres (P < 0.01). Our data demonstrated the effectiveness of anti-pertussis antibodies in bacterial pathogenesis neutralization, emphasizing the importance of placental transfer and breast-feeding in protecting infants against respiratory infections caused by Bordetella pertussis.
Resumo:
Objective: to describe women`s feelings about mode of birth. Design: exploratory descriptive design. Semi-structured interviews were conducted using a questionnaire that had been developed previously (categorical data and open-and closed-ended questions). Qualitative analysis of the results was performed through a context analysis technique. Setting: the largest public university hospital in Brazil. Participants: 48 women in their third trimester of pregnancy. Findings: most women expressed a preference for vaginal birth, as they perceived that they would have a faster recovery. Women who expressed a preference for caesarean section did so because of lack of pain during the birth and the need for tubal sterilisation. The majority of women considered it important to have experience with a mode of birth in order to choose a preference. Complications associated with maternal illness were very influential in the decision-making process. Key conclusions: these results provide a useful first step towards the identification of aspects of women`s feelings about modes of birth. Most women expressed a preference for vaginal birth. Further exploration of women`s feelings regarding parturition and the decision-making process is required. (C) 2008 Elsevier Ltd. All rights reserved.
Resumo:
Objectives To compare the biomechanical characteristics of 2 arthrodesis techniques for the equine proximal interphalangeal joint (PIP) using either a 3-hole 4.5 mm locking compression plate (LCP) or 3-hole 4.5 mm narrow dynamic compression plate (DCP), both with 2 transarticular 5.5 mm cortex screws. Study Design Experimental. Sample Population Cadaveric adult equine forelimbs (*n=6 pairs). Methods For each forelimb pair, 1 limb was randomly assigned to 1 of 2 treatment groups and the contralateral limb by default to the other treatment group. Construct stiffness, gap formation across the PIP joint, and rotation about the PIP joint were determined for each construct before cyclic axial loading and after each of four, 5000 cycle loading regimens. After the 20,000 cycle axial loading regimen, each construct was loaded to failure. Results There were no significant differences in construct stiffness, gap formation, or sagittal plane rotation between the LCP and DCP treatment groups at any of the measured time points. Conclusion Biomechanically, fixation of the equine PIP joint with a 3-hole 4.5 mm LCP is equivalent to fixation with a 3-hole 4.5 mm narrow DCP under the test conditions used.
Resumo:
Santos, K.B.; Daniel, A.G.T. & Hagiwara, M.K. [Reduced erythrocitary Glutathione and Heinz bodies in cats experimentally infected with the Feline Immunodeficiency Virus.] Glutationa Reduzida Eritrocitaria e Corpusculos de Heinz em gatos infectados experimentalmente pelo Virus da Imunodeficieneia Felina. Revista Brasileira de Medicina Veterinaria, 30(1):26-30, 2008. Centro Universitario Serra dos Orgaos, Rua Comendador Queiroz 52, Apto. 1403, Niteroi, RJ 24230-220, Brasil. E-mail: keilabsantos@)gmail.com The Feline Immunodeficiency Virus (FIV) produces a chronic infection with immunologic system disfunctions in domestic cats developing non-responsive anaemia. The feline immunologic status depression produces free radicals, whose imbalance between production and removal in the organism favour the oxidative injury occurrence. Heinz bodies in large amounts also can evident in vivo oxidative damage. Glutatione, a tripeptide found in the animal cells, is an important protection mechanism against oxidative damages. In this work erythrocyte reduced glutathione (GSH) concentrations for healthy and cats experimentally infected by FIV were determinated in relation to the hemogram and the Heinz bodies presence. All of the animals presents normal values for hemogram and Heinz bodies, however the GSH erythrocyte concentrations in the FIV positive cats were below the normality probably due to an passive depletion to GSH.
Resumo:
Provision of an inert gas atmosphere with high-purity argon gas is recommended for preventing titanium castings from contamination although the effects of the level of argon purity on the mechanical properties and the clinical performance of Ti castings have not yet been investigated. The purpose of this study was to evaluate the effect of argon purity on the mechanical properties and microstructure of commercially pure (cp) Ti and Ti-6Al-4V alloys. The castings were made using either high-purity and/or industrial argon gas. The ultimate tensile strength (UTS), proportional limit (PL), elongation (EL) and microhardness (VHN) at different depths were evaluated. The microstructure of the alloys was also revealed and the fracture mode was analyzed by scanning electron microscopy. The data from the mechanical tests and hardness were subjected to a two-and three-way ANOVA and Tukey`s test (alpha = 0.05). The mean values of mechanical properties were not affected by the argon gas purity. Higher UTS, PL and VHN, and lower EL were observed for Ti-6Al-4V. The microhardness was not influenced by the argon gas purity. The industrial argon gas can be used to cast cp Ti and Ti-6Al-4V.
Resumo:
Purpose: Nonpassive fit frameworks are believed to lead to implant overload and consequently loss of osseointegration. This is one of the most commonly reported failures of implant prostheses. In an ideal situation of passive fit, when torque is applied to bring the abutment-cylinder interface together some amount of deformation can be expected, and it should be homogeneous along the periphery of the abutment. The aim of this study was to verify the amount of abutment deformation that can be expected when a free-standing cylinder is screwed into place. This could give insight into what should be accepted as passive fit. Materials and Methods: Strain gauges were bonded to the sides of five standard abutments that had machined palladium-silver cylinders or cobalt-chromium cast cylinders screwed into place. Measurements were taken to verify the deformation at each site. Results: Values of abutment deformation after abutment screw tightening ranged from -127.70 to -590.27 mu epsilon. The deformation recorded for palladium-silver prosthetic cylinder tightening ranged from 56.905 to -381.50 mu epsilon (mean: 173.298 mu epsilon) and from -5.62638 to -383.86 mu epsilon ( mean: 200.474 mu epsilon) for cobalt-chromium cylinders. There was no statistically significant difference among the two groups. Conclusion: Both abutment screw tightening and prosthetic cylinder screw tightening result in abutment deformation, which is compressive most of the time. Int J Prosthodont 2009; 22: 391-395.
Resumo:
Purpose: To test the strength to failure and fracture mode of three indirect composite materials directly applied onto Ti-6Al-4V implant abutments vs cemented standard porcelain-fused-to-metal (PFM) crowns. Materials and Methods: Sixty-four locking taper abutments were randomly allocated to four groups and were cleaned in ethanol in an ultrasonic bath for 5 min. After drying under ambient conditions, the abutments were grit blasted and a custom 4-cusp molar crown mold was utilized to produce identical crowns (n = 16 per group) of Tescera (Bisco), Ceramage (Shofu), and Diamond Crown (DRM) according to the manufacturer`s instructions. The porcelain-fused-to-metal crowns were fabricated by conventional means involving the construction and a wax pattern and casting of a metallic coping followed by sintering of increasing layers of porcelain. All crowns were loaded to failure by an indenter placed at one of the cusp tips at a 1 mm/min rate. Subsequently, fracture analysis was performed by means of stereomicroscopy and scanning electron microscopy. One-way ANOVA at 95% level of significance was utilized for statistical analysis. Results: The single load to failure (+/- SD) results were: Tescera (1130 +/- 239 N), Ceramage (1099 +/- 257 N), Diamond Crown (1155 +/- 284 N), and PFM (1081 +/- 243 N). Stereomicroscopy analysis showed two distinct failure modes, where the loaded cusp failed either with or without abutment/metallic coping exposure. SEM analysis of the fractures showed multiple crack propagation towards the cervical region of the crown below a region of plastic deformation at the indenter contact region. Conclusion: The three indirect composites and PFM systems fractured at loads higher than those typically associated with normal occlusal function. Although each material had a different composition and handling technique, no significant differences were found concerning their single load to fracture resistance among composite systems and PFM.
Resumo:
The quasi mode theory of macroscopic quantization in quantum optics and cavity QED developed by Dalton, Barnett and Knight is generalized. This generalization allows for cases in which two or more quasi permittivities, along with their associated mode functions, are needed to describe the classical optics device. It brings problems such as reflection and refraction at a dielectric boundary, the linear coupler, and the coupling of two optical cavities within the scope of the theory. For the most part, the results that are obtained here are simple generalizations of those obtained in previous work. However the coupling constants, which are of great importance in applications of the theory, are shown to contain significant additional terms which cannot be 'guessed' from the simpler forms. The expressions for the coupling constants suggest that the critical factor in determining the strength of coupling between a pair of quasi modes is their degree of spatial overlap. In an accompanying paper a fully quantum theoretic derivation of the laws of reflection and refraction at a boundary is given as an illustration of the generalized theory. The quasi mode picture of this process involves the annihilation of a photon travelling in the incident region quasi mode, and the subsequent creation of a photon in either the incident region or transmitted region quasi modes.