913 resultados para Nondestructive tests
Resumo:
Mice experimentally infected with a pathogenic strain of Leptospira interrogans serovar Canicola produced false negative results (prozone effect) in a microscopic agglutination test (MAT). This prozone effect occurred in several serum samples collected at different post-infection times, but it was more prominent in samples collected from seven-42 days post-infection and for 1:50 and 1:100 sample dilutions. This phenomenon was correlated with increased antibody titres in the early post-infection phase. While prozone effects are often observed in serological agglutination assays for the diagnosis of animal brucellosis and human syphilis, they are not widely reported in leptospirosis MATs.
Resumo:
INTRODUCTION: Rivaroxaban (RXA) is licensed for prophylaxis of venous thromboembolism after major orthopaedic surgery of the lower limbs. Currently, no test to quantify RXA in plasma has been validated in an inter-laboratory setting. Our study had three aims: to assess i) the feasibility of RXA quantification with a commercial anti-FXa assay, ii) its accuracy and precision in an inter-laboratory setting, and iii) the influence of 10mg of RXA on routine coagulation tests. METHODS: The same chromogenic anti-FXa assay (Hyphen BioMed) was used in all participating laboratories. RXA calibrators and sets of blinded probes (aim ii.) were prepared in vitro by spiking normal plasma. The precise RXA content was assessed by high-pressure liquid chromatography-tandem mass spectrometry. For ex-vivo studies (aim iii), plasma samples from 20 healthy volunteers taken before and 2 - 3hours after ingestion of 10mg of RXA were analyzed by participating laboratories. RESULTS: RXA can be assayed chromogenically. Among the participating laboratories, the mean accuracy and the mean coefficient of variation for precision of RXA quantification were 7.0% and 8.8%, respectively. Mean RXA concentration was 114±43μg/L .RXA significantly altered prothrombin time, activated partial thromboplastin time, factor analysis for intrinsic and extrinsic factors. Determinations of thrombin time, fibrinogen, FXIII and D-Dimer levels were not affected. CONCLUSIONS: RXA plasma levels can be quantified accurately and precisely by a chromogenic anti-FXa assay on different coagulometers in different laboratories. Ingestion of 10mg RXA results in significant alterations of both PT- and aPTT-based coagulation assays.
Resumo:
There is insufficient evidence of the usefulness of dengue diagnostic tests under routine conditions. We sought to analyse how physicians are using dengue diagnostics to inform research and development. Subjects attending 14 health institutions in an endemic area of Colombia with either a clinical diagnosis of dengue or for whom a dengue test was ordered were included in the study. Patterns of test-use are described herein. Factors associated with the ordering of dengue diagnostic tests were identified using contingency tables, nonparametric tests and logistic regression. A total of 778 subjects were diagnosed with dengue by the treating physician, of whom 386 (49.5%) were tested for dengue. Another 491 dengue tests were ordered in subjects whose primary diagnosis was not dengue. Severe dengue classification [odds ratio (OR) 2.2; 95% confidence interval (CI) 1.1-4.5], emergency consultation (OR 1.9; 95% CI 1.4-2.5) and month of the year (OR 3.1; 95% CI 1.7-5.5) were independently associated with ordering of dengue tests. Dengue tests were used both to rule in and rule out diagnosis. The latter use is not justified by the sensitivity of current rapid dengue diagnostic tests. Ordering of dengue tests appear to depend on a combination of factors, including physician and institutional preferences, as well as other patient and epidemiological factors.
Resumo:
Fragile X syndrome is the most common inherited form of intellectual disability. Here we report on a study based on a collaborative registry, involving 12 Spanish centres, of molecular diagnostic tests in 1105 fragile X families comprising 5062 individuals, of whom, 1655 carried a full mutation or were mosaic, three cases had deletions, 1840 had a premutation, and 102 had intermediate alleles. Two patients with the full mutation also had Klinefelter syndrome. We have used this registry to assess the risk of expansion from parents to children. From mothers with premutation, the overall rate of allele expansion to full mutation is 52.5%, and we found that this rate is higher for male than female offspring (63.6% versus 45.6%; P < 0.001). Furthermore, in mothers with intermediate alleles (45-54 repeats), there were 10 cases of expansion to a premutation allele, and for the smallest premutation alleles (55-59 repeats), there was a 6.4% risk of expansion to a full mutation, with 56 repeats being the smallest allele that expanded to a full mutation allele in a single meiosis. Hence, in our series the risk for alleles of <59 repeats is somewhat higher than in other published series. These findings are important for genetic counselling.
Resumo:
This study aimed to standardise an in-house real-time polymerase chain reaction (rtPCR) to allow quantification of hepatitis B virus (HBV) DNA in serum or plasma samples, and to compare this method with two commercial assays, the Cobas Amplicor HBV monitor and the Cobas AmpliPrep/Cobas TaqMan HBV test. Samples from 397 patients from the state of São Paulo were analysed by all three methods. Fifty-two samples were from patients who were human immunodeficiency virus and hepatitis C virus positive, but HBV negative. Genotypes were characterised, and the viral load was measure in each sample. The in-house rtPCR showed an excellent success rate compared with commercial tests; inter-assay and intra-assay coefficients correlated with commercial tests (r = 0.96 and r = 0.913, p < 0.001) and the in-house test showed no genotype-dependent differences in detection and quantification rates. The in-house assay tested in this study could be used for screening and quantifying HBV DNA in order to monitor patients during therapy.
Resumo:
BACKGROUND: Rapid diagnostic tests for malaria (RDTs) allow accurate diagnosis and prompt treatment. Validation of their usefulness in travellers with fever was needed. The safety of a strategy to diagnose falciparum malaria based on RDT followed by immediate or delayed microscopy reading at first attendance was evaluated in one referral hospital in Switzerland. METHODS: A retrospective study was conducted in the outpatient clinic and emergency ward of University Hospital, covering a period of eight years (1999-2007). The study was conducted in the outpatient clinic and emergency ward of University Hospital. All adults suspected of malaria with a diagnostic test performed were included. RDT and microscopy as immediate tests were performed during working hours, and RDT as immediate test and delayed microscopy reading out of laboratory working hours. The main outcome measure was occurrence of specific complications in RDT negative and RDT positive adults. RESULTS: 2,139 patients were recruited. 1987 had both initial RDT and blood smear (BS) result negative. Among those, 2/1987 (0.1%) developed uncomplicated malaria with both RDT and BS positive on day 1 and day 6 respectively. Among the 152 patients initially malaria positive, 137 had both RDT and BS positive, four only BS positive and five only RDT positive (PCR confirmed) (six had only one test performed). None of the four initially RDT negative/BS positive and none of the five initially BS negative/RDT positive developed severe malaria while 6/137 of both RDT and BS positive did so. The use of RDT allowed a reduction of a median of 2.1 hours to get a first malaria test result. CONCLUSIONS: A malaria diagnostic strategy based on RDTs and a delayed BS is safe in non-immune populations, and shortens the time to first malaria test result.
Resumo:
Crear un mòdul per al projecte d'autoavaluació InnovaCampus que ens permeti generar test utilitzant preguntes amb recursos, com podrien ser imatges, àudio, vídeo o documents, i poder generar preguntes que depenguin d'altres anteriors o que estiguin vinculades.
Resumo:
SUMMARYIn order to increase drug safety we must better understand how medication interacts with the body of our patients and this knowledge should be made easily available for the clinicians prescribing the medication. This thesis contributes to how the knowledge of some drug properties can increase and how to make information readily accessible for the medical professionals. Furthermore it investigates the use of Therapeutic drug monitoring, drug interaction databases and pharmacogenetic tests in pharmacovigilance.Two pharmacogenetic studies in the naturalistic setting of psychiatric in-patients clinics have been performed; one with the antidepressant mirtazapine, the other with the antipsychotic clozapine. Forty-five depressed patients have been treated with mirtazapine and were followed for 8 weeks. The therapeutic effect was as seen in other previous studies. Enantioselective analyses could confirm an influence of age, gender and smoking in the pharmacokinetics of mirtazapine; it showed a significant influence of the CYP2D6 genotype on the antidepressant effective S-enantiomer, and for the first time an influence of the CYP2B6 genotype on the plasma concentrations of the 8-OH metabolite was found. The CYP2B6*/*6 genotype was associated to better treatment response. A detailed hypothesis of the metabolic pathways of mirtazapine is proposed. In the second pharmacogenetic study, analyses of 75 schizophrenic patients treated with clozapine showed the influence of CYP450 and ABCB1 genotypes on its pharmacokinetics. For the first time we could demonstrate an in vivo effect of the CYP2C19 genotype and an influence of P-glycoprotein on the plasma concentrations of clozapine. Further we confirmed in vivo the prominent role of CYP1A2 in the metabolism of clozapine.Identifying risk factors for the occurrence of serious adverse drug reactions (SADR) would allow a more individualized and safer drug therapy. SADR are rare events and therefore difficult to study. We tested the feasibility of a nested matched case-control study to examine the influence of high drug plasma levels and CYP2D6 genotypes on the risk to experience an SADR. In our sample we compared 62 SADR cases with 82 controls; both groups were psychiatric patients from the in-patient clinic Königsfelden. Drug plasma levels of >120% of the upper recommended references could be identified as a risk factor with a statistically significant odds ratio of 3.5, a similar trend could be seen for CYP2D6 poor metaboliser. Although a matched case-control design seems a valid method, 100% matching is not easy to perform in a relative small cohort of one in-patient clinic. However, a nested case-control study is feasible.On the base of the experience gained in the AMSP+ study and the fact that we have today only sparse data indicating that routine drug plasma concentration monitoring and/or pharmacogenetic testing in psychiatry are justified to minimize the risk for ADR, we developed a test algorithm named "TDM plus" (TDM plus interaction checks plus pharmacogenetic testing).Pharmacovigilance programs such as the AMSP project (AMSP = Arzneimittelsicherheit in der Psychiatrie) survey psychiatric in-patients in order to collect SADR and to detect new safety signals. Case reports of such SADR are, although anecdotal, valuable to illustrate rare clinical events and sometimes confirm theoretical assumptions of e.g. drug interactions. Seven pharmacovigilance case reports are summarized in this thesis.To provide clinicians with meaningful information on the risk of drug combinations, during the course of this thesis the internet based drug interaction program mediQ.ch (in German) has been developed. Risk estimation is based on published clinical and pharmacological information of single drugs and alimentary products, including adverse drug reaction profiles. Information on risk factors such as renal and hepatic insufficiency and specific genotypes are given. More than 20'000 drug pairs have been described in detail. Over 2000 substances with their metabolic and transport pathways are included and all information is referenced with links to the published scientific literature or other information sources. Medical professionals of more than 100 hospitals and 300 individual practitioners do consult mediQ.ch regularly. Validations with comparisons to other drug interaction programs show good results.Finally, therapeutic drug monitoring, drug interaction programs and pharmacogenetic tests are helpful tools in pharmacovigilance and should, in absence of sufficient routine tests supporting data, be used as proposed in our TDM plus algorithm.RESUMEPour améliorer la sécurité d'emploi des médicaments il est important de mieux comprendre leurs interactions dans le corps des patients. Ensuite le clinicien qui prescrit une pharmacothérapie doit avoir un accès simple à ces informations. Entre autres, cette thèse contribue à mieux connaître les caractéristiques pharmacocinétiques de deux médicaments. Elle examine aussi l'utilisation de trois outils en pharmacovigilance : le monitorage thérapeutique des taux plasmatiques des médicaments (« therapeutic drug monitoring »), un programme informatisé d'estimation du risque de combinaisons médicamenteuses, et enfin des tests pharmacogénétiques.Deux études cliniques pharmacogénétiques ont été conduites dans le cadre habituel de clinique psychiatrique : l'une avec la mirtazapine (antidépresseur), l'autre avec la clozapine (antipsychotique). On a traité 45 patients dépressifs avec de la mirtazapine pendant 8 semaines. L'effet thérapeutique était semblable à celui des études précédentes. Nous avons confirmé l'influence de l'âge et du sexe sur la pharmacocinétique de la mirtazapine et la différence dans les concentrations plasmatiques entre fumeurs et non-fumeurs. Au moyen d'analyses énantiomères sélectives, nous avons pu montrer une influence significative du génotype CYP2D6 sur l'énantiomère S+, principalement responsable de l'effet antidépresseur. Pour la première fois, nous avons trouvé une influence du génotype CYP2B6 sur les taux plasmatiques de la 8-OH-mirtazapine. Par ailleurs, le génotype CYP2B6*6/*6 était associé à une meilleure réponse thérapeutique. Une hypothèse sur les voies métaboliques détaillées de la mirtazapine est proposée. Dans la deuxième étude, 75 patients schizophrènes traités avec de la clozapine ont été examinés pour étudier l'influence des génotypes des iso-enzymes CYP450 et de la protéine de transport ABCB1 sur la pharmacocinétique de cet antipsychotique. Pour la première fois, on a montré in vivo un effet des génotypes CYP2C19 et ABCB1 sur les taux plasmatiques de la clozapine. L'importance du CYP1A2 dans le métabolisme de la clozapine a été confirmée.L'identification de facteurs de risques dans la survenue d'effets secondaire graves permettrait une thérapie plus individualisée et plus sûre. Les effets secondaires graves sont rares. Dans une étude de faisabilité (« nested matched case-control design » = étude avec appariement) nous avons comparé des patients avec effets secondaires graves à des patients-contrôles prenant le même type de médicaments mais sans effets secondaires graves. Des taux plasmatiques supérieurs à 120% de la valeur de référence haute sont associés à un risque avec « odds ratio » significatif de 3.5. Une tendance similaire est apparue pour le génotype du CYP2D6. Le « nested matched case-control design » semble une méthode valide qui présente cependant une difficulté : trouver des patients-contrôles dans le cadre d'une seule clinique psychiatrique. Par contre la conduite d'une « nested case-control study » sans appariement est recommandable.Sur la base de notre expérience de l'étude AMSP+ et le fait que nous disposons que de peux de données justifiant des monitorings de taux plasmatiques et/ou de tests pharmacogénétiques de routine, nous avons développé un test algorithme nommé « TDMplus » (TDM + vérification d'interactions médicamenteuses + tests pharmacogénétique).Des programmes de pharmacovigilances comme celui de l'AMSP (Arzneimittelsicherheit in der Psychiatrie = pharmacovigilance en psychiatrie) collectent les effets secondaires graves chez les patients psychiatriques hospitalisés pour identifier des signaux d'alertes. La publication de certains de ces cas même anecdotiques est précieuse. Elle décrit des événements rares et quelques fois une hypothèse sur le potentiel d'une interaction médicamenteuse peut ainsi être confirmée. Sept publications de cas sont résumées ici.Dans le cadre de cette thèse, on a développé un programme informatisé sur internet (en allemand) - mediQ.ch - pour estimer le potentiel de risques d'une interaction médicamenteuse afin d'offrir en ligne ces informations utiles aux cliniciens. Les estimations de risques sont fondées sur des informations cliniques (y compris les profils d'effets secondaires) et pharmacologiques pour chaque médicament ou substance combinés. Le programme donne aussi des informations sur les facteurs de risques comme l'insuffisance rénale et hépatique et certains génotypes. Actuellement il décrit en détail les interactions potentielles de plus de 20'000 paires de médicaments, et celles de 2000 substances actives avec leurs voies de métabolisation et de transport. Chaque information mentionne sa source d'origine; un lien hypertexte permet d'y accéder. Le programme mediQ.ch est régulièrement consulté par les cliniciens de 100 hôpitaux et par 300 praticiens indépendants. Les premières validations et comparaisons avec d'autres programmes sur les interactions médicamenteuses montrent de bons résultats.En conclusion : le monitorage thérapeutique des médicaments, les programmes informatisés contenant l'information sur le potentiel d'interaction médicamenteuse et les tests pharmacogénétiques sont de précieux outils en pharmacovigilance. Nous proposons de les utiliser en respectant l'algorithme « TDM plus » que nous avons développé.
Resumo:
The classical description of Si oxidation given by Deal and Grove has well-known limitations for thin oxides (below 200 Ã). Among the large number of alternative models published so far, the interfacial emission model has shown the greatest ability to fit the experimental oxidation curves. It relies on the assumption that during oxidation Si interstitials are emitted to the oxide to release strain and that the accumulation of these interstitials near the interface reduces the reaction rate there. The resulting set of differential equations makes it possible to model diverse oxidation experiments. In this paper, we have compared its predictions with two sets of experiments: (1) the pressure dependence for subatmospheric oxygen pressure and (2) the enhancement of the oxidation rate after annealing in inert atmosphere. The result is not satisfactory and raises serious doubts about the model’s correctness
Resumo:
Current monitoring techniques for determination of compaction of earthwork and asphalt generally involve destructive testing of the materials following placement. Advances in sensor technologies show significant promise for obtaining necessary information through nondestructive and remote techniques. To develop a better understanding of suitable and potential technologies, this study was undertaken to conduct a synthesis review of nondestructive testing technologies and perform preliminary evaluations of selected technologies to better understand their application to testing of geomaterials (soil fill, aggregate base, asphalt, etc.). This research resulted in a synthesis of potential technologies for compaction monitoring with a strong emphasis on moisture sensing. Techniques were reviewed and selectively evaluated for their potential to improve field quality control operations. Activities included an extensive review of commercially available moisture sensors, literature review, and evaluation of selected technologies. The technologies investigated in this study were dielectric, nuclear, near infrared spectroscopy, seismic, electromagnetic induction, and thermal. The primary disadvantage of all the methods is the small sample volume measured. In addition, all the methods possessed some sensitivity to non-moisture factors that affected the accuracy of the results. As the measurement volume increases, local variances are averaged out providing better accuracy. Most dielectric methods with the exception of ground penetrating radar have a very small measurement volume and are highly sensitive to variations in density, porosity, etc.