921 resultados para MV cone beam


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Sinus floor augmentation has been established as a predictable technique to overcome maxillary bone loss. Antral cystic lesions may lead to intrasurgical complications and should be accurately diagnosed. However, antral pseudocysts have recently been described not to be contraindicated for sinus-grafting procedures. The current article sought to report clinical, cone beam computed tomographic, and histologic results of a maxillary sinus floor augmentation, performed with piezoelectric surgery, in the presence of a large antral pseudocyst. Success of graft maturation was confirmed with histologic analysis, which also indicated the absence of inflammatory infiltration in the tissue evaluated. On the basis of our findings, it is possible to perform a predictable treatment based on sinus floor augmentation in the presence of antral pseudocysts. Graft maturation can also be achieved 6 months after sinus-lifting surgeries.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Objective: This study aimed to assess the presence of additional foramina and canals in the anterior palate region, through cone beam computed tomography (CBCT) images, describing their location, direction, and diameter. Materials & Methods: CBCT exams of 178 subjects displaying the anterior maxilla were included and the following parameters were registered: gender; age group; presence of additional foramina in the anterior palate (AFP) with at least 1 mm in diameter; location and diameter of AFP; and direction of bony canals associated with AFP. Results: Twenty-eight patients (15.7%) presented AFP and in total 34 additional foramina were registered. No statistical differences between patients with or without AFP were found for gender or age. The average diameter of AFP was 1.4 mm (range from 1 to 1.9 mm). Their location was variable, with most of the cases occurring in the alveolar process near the incisors or canines (n = 27). In 18 cases, AFP was associated with bony canals with upward or oblique direction toward the anterior nasal cavity floor. In 14 cases, the canal presented as a direct extension of the canalis sinuosus, in an upward direction laterally to the nasal cavity aperture. In two cases, the canal was observed adjacent to the incisive and joined the nasopalatine canal superiorly. Discussion: CBCT images have a crucial role in the recognition of anatomical variations by allowing detailed tridimensional evaluations. Additional foramina and canals in the anterior region of the upper jaw are relatively frequent. Practitioners should be aware and trained to identify these variations. Conclusions: Over 15% of the population studied had additional foramina in the anterior palate, between 1 mm and 1.9 mm wide, with variable locations. In most cases the canals associated with these foramina either presented as a direct extension of the canalis sinuosus, or coursed towards the nasal cavity floor.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Objectives: The objective of this study is to compare subjective image quality and diagnostic validity of cone-beam CT (CBCT) panoramic reformatting with digital panoramic radiographs. Materials and methods: Four dry human skulls and two formalin-fixed human heads were scanned using nine different CBCTs, one multi-slice CT (MSCT) and one standard digital panoramic device. Panoramic views were generated from CBCTs in four slice thicknesses. Seven observers scored image quality and visibility of 14 anatomical structures. Four observers repeated the observation after 4 weeks. Results: Digital panoramic radiographs showed significantly better visualization of anatomical structures except for the condyle. Statistical analysis of image quality showed that the 3D imaging modalities (CBCTs and MSCT) were 7.3 times more likely to receive poor scores than the 2D modality. Yet, image quality from NewTom VGi® and 3D Accuitomo 170® was almost equivalent to that of digital panoramic radiographs with respective odds ratio estimates of 1.2 and 1.6 at 95% Wald confidence limits. A substantial overall agreement amongst observers was found. Intra-observer agreement was moderate to substantial. Conclusions: While 2D-panoramic images are significantly better for subjective diagnosis, 2/3 of the 3D-reformatted panoramic images are moderate or good for diagnostic purposes. Clinical relevance: Panoramic reformattings from particular CBCTs are comparable to digital panoramic images concerning the overall image quality and visualization of anatomical structures. This clinically implies that a 3D-derived panoramic view can be generated for diagnosis with a recommended 20-mm slice thickness, if CBCT data is a priori available for other purposes.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The main problem connected to cone beam computed tomography (CT) systems for industrial applications employing 450 kV X-ray tubes is the high amount of scattered radiation which is added to the primary radiation (signal). This stray radiation leads to a significant degradation of the image quality. A better understanding of the scattering and methods to reduce its effects are therefore necessary to improve the image quality. Several studies have been carried out in the medical field at lower energies, whereas studies in industrial CT, especially for energies up to 450 kV, are lacking. Moreover, the studies reported in literature do not consider the scattered radiation generated by the CT system structure and the walls of the X-ray room (environmental scatter). In order to investigate the scattering on CT projections a GEANT4-based Monte Carlo (MC) model was developed. The model, which has been validated against experimental data, has enabled the calculation of the scattering including the environmental scatter, the optimization of an anti-scatter grid suitable for the CT system, and the optimization of the hardware components of the CT system. The investigation of multiple scattering in the CT projections showed that its contribution is 2.3 times the one of primary radiation for certain objects. The results of the environmental scatter showed that it is the major component of the scattering for aluminum box objects of front size 70 x 70 mm2 and that it strongly depends on the thickness of the object and therefore on the projection. For that reason, its correction is one of the key factors for achieving high quality images. The anti-scatter grid optimized by means of the developed MC model was found to reduce the scatter-toprimary ratio in the reconstructed images by 20 %. The object and environmental scatter calculated by means of the simulation were used to improve the scatter correction algorithm which could be patented by Empa. The results showed that the cupping effect in the corrected image is strongly reduced. The developed CT simulation is a powerful tool to optimize the design of the CT system and to evaluate the contribution of the scattered radiation to the image. Besides, it has offered a basis for a new scatter correction approach by which it has been possible to achieve images with the same spatial resolution as state-of-the-art well collimated fan-beam CT with a gain in the reconstruction time of a factor 10. This result has a high economic impact in non-destructive testing and evaluation, and reverse engineering.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

L'elaborato espone l'iter di un paziente nel reparto di radioterapia e descrive l'evoluzione delle immagini radioterapiche dai portal film alle Cone Beam Computer Tomography. Inoltre espone i vari standard e protocolli usati per archiviare e trasmettere le immagini digitali precedentemente descritte.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The purpose of this study was to evaluate whether measurements on conventional cephalometric radiographs are comparable with 3D measurements on 3D models of human skulls, derived from cone beam CT (CBCT) data. A CBCT scan and a conventional cephalometric radiograph were made of 40 dry skulls. Standard cephalometric software was used to identify landmarks on both the 2D images and the 3D models. The same operator identified 17 landmarks on the cephalometric radiographs and on the 3D models. All images and 3D models were traced five times with a time-interval of 1 week and the mean value of repeated measurements was used for further statistical analysis. Distances and angles were calculated. Intra-observer reliability was good for all measurements. The reproducibility of the measurements on the conventional cephalometric radiographs was higher compared with the reproducibility of measurements on the 3D models. For a few measurements a clinically relevant difference between measurements on conventional cephalometric radiographs and 3D models was found. Measurements on conventional cephalometric radiographs can differ significantly from measurements on 3D models of the same skull. The authors recommend that 3D tracings for longitudinal research are not used in cases were there are only 2D records from the past.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

PURPOSE: The advent of imaging software programs has proved to be useful for diagnosis, treatment planning, and outcome measurement, but precision of 3-dimensional (3D) surgical simulation still needs to be tested. This study was conducted to determine whether the virtual surgery performed on 3D models constructed from cone-beam computed tomography (CBCT) can correctly simulate the actual surgical outcome and to validate the ability of this emerging technology to recreate the orthognathic surgery hard tissue movements in 3 translational and 3 rotational planes of space. MATERIALS AND METHODS: Construction of pre- and postsurgery 3D models from CBCTs of 14 patients who had combined maxillary advancement and mandibular setback surgery and 6 patients who had 1-piece maxillary advancement surgery was performed. The postsurgery and virtually simulated surgery 3D models were registered at the cranial base to quantify differences between simulated and actual surgery models. Hotelling t tests were used to assess the differences between simulated and actual surgical outcomes. RESULTS: For all anatomic regions of interest, there was no statistically significant difference between the simulated and the actual surgical models. The right lateral ramus was the only region that showed a statistically significant, but small difference when comparing 2- and 1-jaw surgeries. CONCLUSIONS: Virtual surgical methods were reliably reproduced. Oral surgery residents could benefit from virtual surgical training. Computer simulation has the potential to increase predictability in the operating room.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A 19-year old female patient was referred for removal of her wisdom teeth. The panoramic radiograph showed bilateral retromolar canals in the mandible. Since the retromolar canal is neglected in anatomical textbooks and is rarely documented in scientific publications, the case prompted us to perform further diagnostic examinations with informed consent by the patient. A limited cone beam computed tomography was made and, during the surgical removal of the patient's lower right wisdom tooth, a biopsy of the soft tissue bundle emerging from the retromolar foramen was taken. In accordance with the literature, the histology revealed myelinated nerve fibers, small arteries and venules. The limited data available in the literature about the retromolar canal report that this bony canal may convey an aberrant buccal nerve. In addition, sensory nerve fibers entering the retromolar canal from above and branching to the mandibular molars may evade a block anesthesia at the mandibular foramen. These rare anatomic features may explain why the elements of the retromolar canal account for failures of mandibular block anesthesia or postsurgical sensitivity changes in the supply area of the buccal nerve.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Bonding a flexible spiral wire retainer to the lingual surfaces of all 6 anterior mandibular teeth is a commonly used type of retention. Complications are rare but can be serious enough to produce biologic damage. This article presents a serious complication of a lingual flexible spiral wire retainer. Four years after the orthodontic treatment, a 20-year-old man sought treatment for a broken flexible spiral wire retainer. The clinical examination showed about 35° of buccal root torque of that tooth. A cone-beam computed tomography image showed that the root and the apex of the tooth were almost completely out of the bone on its buccal side. Surprisingly, the tooth's vitality was preserved. The tooth was moved back, nearly to its original position; clinically, only a gingival recession remained. Orthodontists and dentists should be aware of possible complications of bonded retainers. Patients should be clearly informed how to detect problems at an early stage.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

To estimate the applicability of potential sites for insertion of orthodontic mini-implants (OMIs) by a systematic review of studies that used computed tomography (CT) or cone beam CT to evaluate anatomical bone quality and quantity parameters, such as bone thickness, available space, and bone density.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Morphea is a cutaneous disorder characterized by an excessive collagen deposition. While in almost all cases the sclerosing process exclusively affects the skin, there are anecdotal cases in which associated mucosal involvement has been described. We here report the case of a woman developing a whitish indurated plaque over the left upper vestibular mucosa and hard palate leading to dental mobility and exposure of the roots of several teeth. Cone beam computed tomography of the left maxilla showed bone resorption involving the upper cuspid to the second molar region with widened periodontal ligament spaces, while light microscopy studies demonstrated epithelial atrophy and fibrosis of the dermis extending into the submucosa with hyalinization of subepithelial collagen. Our observation expands the spectrum of clinical presentations of morphea and provides the first example of isolated oral morphea. Its recognition is important to avoid significant local complications.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Diagnostics imaging is an essential component of patient selection and treatment planning in oral rehabilitation by means of osseointegrated implants. In 2002, the EAO produced and published guidelines on the use of diagnostic imaging in implant dentistry. Since that time, there have been significant developments in both the application of cone beam computed tomography as well as in the range of surgical and prosthetic applications that can potentially benefit from its use. However, medical exposure to ionizing radiation must always be justified and result in a net benefit to the patient. The as low a dose as is reasonably achievable principle must also be applied taking into account any alternative techniques that might achieve the same objectives. This paper reports on current EAO recommendations arising from a consensus meeting held at the Medical University of Warsaw (2011) to update these guidelines. Radiological considerations are detailed, including justification and optimization, with a special emphasis on the obligations that arise for those who prescribe or undertake such investigations. The paper pays special attention to clinical indications and radiographic diagnostic considerations as well as to future developments and trends.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Conclusion: A robot built specifically for stereotactic cochlear implantation provides equal or better accuracy levels together with a better integration into a clinical environment, when compared to existing approaches based on industrial robots. Objectives: To evaluate the technical accuracy of a robotic system developed specifically for lateral skull base surgery in an experimental setup reflecting the intended clinical application. The invasiveness of cochlear electrode implantation procedures may be reduced by replacing the traditional mastoidectomy with a small tunnel slightly larger in diameter than the electrode itself. Methods: The end-to-end accuracy of the robot system and associated image-guided procedure was evaluated on 15 temporal bones of whole head cadaver specimens. The main components of the procedure were as follows: reference screw placement, cone beam CT scan, computer-aided planning, pair-point matching of the surgical plan, robotic drilling of the direct access tunnel, and post-operative cone beam CT scan and accuracy assessment. Results: The mean accuracy at the target point (round window) was 0.56 ± 41 mm with an angular misalignment of 0.88 ± 0.41°. The procedural time of the registration process through the completion of the drilling procedure was 25 ± 11 min. The robot was fully operational in a clinical environment.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Image-guided microsurgery requires accuracies an order of magnitude higher than today's navigation systems provide. A critical step toward the achievement of such low-error requirements is a highly accurate and verified patient-to-image registration. With the aim of reducing target registration error to a level that would facilitate the use of image-guided robotic microsurgery on the rigid anatomy of the head, we have developed a semiautomatic fiducial detection technique. Automatic force-controlled localization of fiducials on the patient is achieved through the implementation of a robotic-controlled tactile search within the head of a standard surgical screw. Precise detection of the corresponding fiducials in the image data is realized using an automated model-based matching algorithm on high-resolution, isometric cone beam CT images. Verification of the registration technique on phantoms demonstrated that through the elimination of user variability, clinically relevant target registration errors of approximately 0.1 mm could be achieved.