963 resultados para Led Zeppelin
Resumo:
The aim of this study was to test a newly developed LED-based fluorescence device for approximal caries detection in vitro. We assembled 120 extracted molars without frank cavitations or fillings pairwise in order to create contact areas. The teeth were independently assessed by two examiners using visual caries detection (International Caries Detection and Assessment System, ICDAS), bitewing radiography (BW), laser fluorescence (LFpen), and LED fluorescence (Midwest Caries I.D., MW). The measurements were repeated at least 1 week later. The diagnostic performance was calculated with Bayesian analyses. Post-test probabilities were calculated in order to judge the diagnostic performance of combined methods. Reliability analyses were performed using kappa statistics for nominal data and intraclass correlation (ICC) for absolute data. Histology served as the gold standard. Sensitivities/specificities at the enamel threshold were 0.33/0.84 for ICDAS, 0.23/0.86 for BW, 0.47/0.78 for LFpen, and 0.32/0.87 for MW. Sensitivities/specificities at the dentine threshold were 0.04/0.89 for ICDAS, 0.27/0.94 for BW, 0.39/0.84 for LFpen, and 0.07/0.96 for MW. Reliability data were fair to moderate for MW and good for BW and LFpen. The combination of ICDAS and radiography yielded the best diagnostic performance (post-test probability of 0.73 at the dentine threshold). The newly developed LED device is not able to be recommended for approximal caries detection. There might be too much signal loss during signal transduction from the occlusal aspect to the proximal lesion site and the reverse.
Resumo:
anonym
Resumo:
Purpose. The purpose of this randomized control repeated measures trial was to determine the effectiveness of a self-management intervention led by community lay workers called promotoras on the health outcomes of Mexican Americans with type 2 diabetes living in a major city on the Texas - Mexico border. The specific aims of this study, in relation to the intervention group participants, were to: (1) decrease the glycosylated hemoglobin (A1c) blood levels at the six-month assessment, (2) increase diabetes knowledge at the three and six-month assessments, and (3) strengthen the participants' beliefs in their ability to manage diabetes at the three and six-month assessments.^ Methods. One hundred and fifty Mexican American participants were recruited at a Catholic faith-based clinic and randomized into an intervention group and a usual-care control group. Personal characteristics, acculturation and baseline A1c, diabetes knowledge and diabetes health beliefs were measured. The six-month, two-phase intervention was culturally specific and it was delivered entirely by promotoras. Phase One of the intervention consisted of sixteen hours of participative group education and bi-weekly telephone contact follow-up. Phase Two consisted of bi-weekly follow-up using inspirational faith-based health behavior change postcards. The A1c levels, diabetes knowledge and diabetes health beliefs were measured at baseline, and three and six months post-baseline. The mean changes between the groups were analyzed using analysis of covariance. ^ Results. The 80% female sample, with a mean age of 58 years, demonstrated very low: acculturation, income, education, health insurance coverage, and strong Catholicism. No significant changes were noted at the three-month assessment, but the mean change of the A1c levels (F (1, 148 = 10.28, p < .001) and the diabetes knowledge scores (F (1, 148 = 9.0, p < .002) of the intervention group improved significantly at six months, adjusting for health insurance coverage. The diabetes health belief scores decreased in both groups.^ Conclusions. This study demonstrated that an intervention led by promotoras could result in decreased A1c levels and increased diabetes knowledge in spite of the very low acculturation, educational level and insurance coverage of the intervention group participants. Clinical implications and recommendations for future research are suggested. ^
Resumo:
This pilot study, conducted in the Houston, TX, area, established a structured dialogue among a university Institutional Review Board, its researchers, and its local community members (i.e. pool of potential research participants) for the purpose of further educating all three parties about genetic research and community concerns related to such research. An IRB-designed educational presentation aimed at assisting potential subjects in making an informed decision to participate in genetic research was provided to four community groups (n=54); this presentation also included a current example of genetic research being conducted in the community as explained by the researcher, and a question-and-answer session designed to assist the IRB and the researcher in understanding the community's concerns about genetic research. Comparisons of pre- and post- presentation community questionnaires indicate that the joint presentation was effective in increasing community knowledge about genetic research, most notably related to the risks and benefits of this research to the individual, as well as the understanding that protections are in place for research participants. While researchers are optimistic about the idea of a collaborative effort with the IRB and the community, the feasibility of such a program and the benefit to the participating researchers remain unclear; additional research is necessary to establish the most effective method of communication for all groups involved, as well as to obtain statistically significant results with regard to race/ethnicity, gender, and education levels of community participants. ^
Resumo:
This paper includes an examination of the sustainability of recent high growth in the poultry meat industry in Brazil. In addition, an assessment is made of the impact of increased production of poultry meat products on the development of local industries. Comparative studies of leading companies in the United States, Mexico, and Brazil reveal competitive advantages in the low costs of feedstuff and labor as well as disadvantages in the scale of business and management efficiency in the Brazilian poultry sector. Increases in domestic and foreign demand for Brazilian poultry meat have promoted development of the Brazilian poultry sector in local areas. The formation of industrial clusters is observed using regional data related to the location of slaughterhouses and the number of chickens farmed. Statistical analyses support observations made in this paper.
Resumo:
In this paper we show that the effect of jitter due to driver and LED is the limiting factor in the baud rate in L-PPM formats for VLC systems.
Resumo:
An LED backlight has been designed using the flow-line design method. This method allows a very efficient control of the light extraction. The light is confined inside the guide by total internal reflection, being extracted only by specially calculated surfaces: the ejectors. Backlight designs presented here have a total optical efficiency of up to 80% (including Fresnel and absorption losses) with an FWHM below 30 degrees. The experimental results of the first prototype are shown.
Resumo:
Optics detailed analysis of an improved collimation system for LED light sources
Resumo:
In SSL general illumination, there is a clear trend to high flux packages with higher efficiency and higher CRI addressed with the use of multiple color chips and phosphors. However, such light sources require the optics provide color mixing, both in the near-field and far-field. This design problem is specially challenging for collimated luminaries, in which diffusers (which dramatically reduce the brightness) cannot be applied without enlarging the exit aperture too much. In this work we present first injection molded prototypes of a novel primary shell-shaped optics that have microlenses on both sides to provide Köhler integration. This shell is design so when it is placed on top of an inhomogeneous multichip Lambertian LED, creates a highly homogeneous virtual source (i.e, spatially and angularly mixed), also Lambertian, which is located in the same position with only small increment of the size (about 10-20%, so the average brightness is similar to the brightness of the source). This shell-mixer device is very versatile and permits now to use a lens or a reflector secondary optics to collimate the light as desired, without color separation effects. Experimental measurements have shown optical efficiency of the shell of 95%, and highly homogeneous angular intensity distribution of collimated beams, in good agreement with the ray-tracing simulations.
Resumo:
Two quasi-aplanatic free-form solid V-groove collimators are presented in this work. Both optical designs are originally designed using the Simultaneous Multiple Surface method in three dimensions (SMS 3D). The second optically active surface in both free-form V-groove devices is designed a posteriori as a grooved surface. First two mirror (XX) design is designed in order to clearly show the design procedure and working principle of these devices. Second, RXI free-form design is comparable with existing RXI collimators; it is a compact and highly efficient design made of polycarbonate (PC) performing very good colour mixing of the RGGB LED sources placed off-axis. There have been presented rotationally symmetric non-aplanatic high efficiency collimators with colour mixing property to be improved and rotationally symmetric aplanatic devices with good colour mixing property and efficiency to be improved. The aim of this work was to design a free-form device in order to improve colour mixing property of the rotationally symmetric nonaplanatic RXI devices and the efficiency of the aplanatic ones.
Resumo:
El enfriamiento tradicional de los LEDs, mediante disipadores térmicos, se ve muchas veces comprometido al tener que disponer estos elementos refrigeradores justo en el punto de generación de la luz. Para evitar, en la medida de lo posible, este hecho, se presenta como una de las posibles alternativas el empleo de los ?Heat Pipes?. Los Heat Pipes son unos dispositivos autónomos, que permiten refrigerar los focos calientes, trasladando el calor generado por ellos a disipadores térmicos situados en zonas más accesibles y menos comprometidas. Los Heat Pipe, basados en técnicas termodinámicas, tienen un uso muy extendido en la tecnología aeroespacial. Son actualmente la solución ideal en aplicaciones de bombeo de calor y refrigeración de componenetes electricos y electrónicos. Con tamaños reducidos, pueden alcanzar flujos de refrigeración de 300 - 400 W/cm2. En esta comunicación se presenta y analiza este tipo de refrigeración aplicada a LED¿s utilizados en iluminación y alumbrado. La refrigeración de LEDs propuesta está compuesta por el Heat Pipe adosado por un extremo a la cara posterior del diodo LED, y por el otro, a una cierta distancia, al disipador térmico. La temperatura alcanzada por el LED dependerá del tipo y características del Heat Pipe así como de las cualidades del disipador térmico utilizado. También se utilizan en combinación con refrigeradores termoeléctricos (células de Peltier) cuando se desea controlar la temperatura de los dispositivos por debajo de la temperatura ambiental.
Resumo:
El objetivo de este proyecto es el de determinar, a través de una serie de medidas, los tiempos de vida y causas de fallo de diodos LED. Para ello, se someterá a los dispositivos a condiciones extremas de temperatura y humedad dentro de una cámara climática, con el objetivo de acelerar su edad, su tiempo de uso, hecho que provocará la aparición de los fallos mucho antes que en condiciones normales de funcionamiento. Se tomarán medidas tanto de su tensión y corriente para el análisis de las gráficas I-V, dentro y fuera de la cámara, como de las potencias luminosas de cada uno de ellos. Estas medidas se realizarán en dos ocasiones al día, en intervalos de no menos de 6 horas. Para las medidas de tensión y corriente se utilizará un programa desarrollado en el entorno de LabView, tanto para las medidas en el interior de la cámara, lo que nos permite un seguimiento específico del estado de los dispositivos en cada momento, como para las medidas fuera de ella. Para las medidas de la potencia luminosa de cada LED se utilizará un medidor de potencia óptica. Cada ensayo constará de 15 dispositivos LED, que se evaluarán en las mismas condiciones de temperatura y humedad. El resumen de los 8 ensayos realizados es el que sigue: - Ensayo 1: 140ºC 85% HUMEDAD a 10 mA. - Ensayo 2: 140ºC 70% HUMEDAD a 10 mA. - Ensayo 3: 120ºC 85% HUMEDAD a 10 mA. - Ensayo 4: 120ºC 85% HUMEDAD a 30 mA. - Ensayo 5: 140ºC 70% HUMEDAD a 30 mA. - Ensayo 6: 140ºC 85% HUMEDAD a 30 mA. - Ensayo 7: 140ºC 60% HUMEDAD a 30 mA. - Ensayo 8: 140ºC 85% HUMEDAD a 20 mA. Una vez tomadas las medidas, se analizarán los datos, de cara a obtener una ley de degradación del LED a través del análisis de Weibull y se estudiarán las diferentes causas de fallo. ABSTRACT. The aim of this Project is to determine, based on several measures, the lifetime and the causes of LED’s failures. The devices will be tested under extreme both temperature and humidity conditions in a Pressure Cooker, attempting to make faults to appear earlier. Voltage and current measures will be taken, inside and also outside the Pressure cooker, in order to use them in I-V graphs. In addition, luminous power measures for each LED will be taken. All those measures will be obtained twice a day, with 6 hours delay between both of them. A program based on LabView environment will be used to take voltage and current measures, inside and outside the pressure cooker, which allow us to follow the performance of the LED at each moment. The luminous power of each LED will be taken by a measurer. Each test consists of 15 LED devices, which will be evaluated under the same conditions each time. The 8 tests are as follows - Test 1: 140ºC 85% relative humidity at 10 mA. - Test 2: 140ºC 70% relative humidity at 10 mA. - Test 3: 120ºC 85% relative humidity at 10 mA. - Test 4: 120ºC 85% relative humidity at 30 mA. - Test 5: 140ºC 70% relative humidity at 30 mA. - Test 6: 140ºC 85% relative humidity at 30 mA. - Test 7: 140ºC 60% relative humidity at 30 mA. - Test 8: 140ºC 85% relative humidity at 20 mA. When the measures are completely taken, data will be analyzed, in order to obtain a LED’s degradation law using Weibull’s distribution. Also the causes of the failures will be evaluated.
Resumo:
En este proyecto fin de carrera se ha diseñado y construido un equipo de medida automático que permite realizar la medida de la constante de Planck utilizando los principios de Funcionamiento de los diodos LED. El equipo de medida es totalmente automático gracias a la utilización de una placa controladora Arduino MEGA 2560, que se encarga de realizar la iluminación secuencial de cada LED, medir sus tensiones de funcionamiento, y de realizar los cálculos necesarios para hallar la constante de Planck. Todos los datos se muestran por una pantalla LCD de 16 caracteres por 2 lineas. Para comprender el funcionamiento del sistema de medida automático se ha realizado un estudio detallado de cada uno de los sistemas que componen el equipo de medida. Se ha explicado el funcionamiento teórico de los diodos LED y el funcionamiento de los semiconductores. Se ha explicando los diversos tipos de semiconductores que se utilizan para los LED y las modificaciones que se les aplica para mejorar su eficiencia. Para poder comprender en qué consiste la constante de Planck se ha explicado los principios teóricos en que se basa, y se ha realizado una pequeña demostración de su cálculo. Una vez visto todos los principios teóricos se ha pasado a realizar la explicación de cada uno de los grandes bloques que componen el sistema de medida automático. Estos bloques son la placa controladora Arduino, el sistema de iluminación LED, el sistema de control mecánico de LEDs, la pantalla LCD, el sistema de interrupciones y el sistema de alimentación. Para poder observar el espectro de emisión de cada uno de los LED se ha utilizado un analizador de espectros óptico (OSA), el cual ha sido explicado con detenimiento. El código de programación de Arduino ha sido explicado en forma de diagrama de flujo para una mayor facilidad de comprensión. Se ha desarrollado un manual de usuario para facilitar el uso del sistema a cualquier usuario, en el que se ha introducido un ejemplo completo de funcionamiento. ABSTRACT. In this final Project has designed and built an automatic measuring equipment which is able to measure the Planck`s constant using the operation principles of the LEDs. The measuring equipment is fully automated thanks to the use of an Arduino Mega 2560 controller board, which is responsible for conducting sequential illumination of each LED, measure their operating voltages, and perform the necessary calculations of find the Planck constant. All data is displayed by a LCD screen 16 character by 2 lines. To understand the operation of the automatic measuring system has been made a detailed study of each of the systems that make the measurement equipment. It develops the theoretical performance of the LED and the operation of semiconductors. It explains the different types of semiconductors that are used for LEDs and the changes applied to improve efficiency. In order to understand what is the Planck constant has been explained the theoretical principles in which it is based, and a small demonstration of its calculation has been performed. After seeing all the theoretical principles has been made the explanation of each of the main blocks that compose the automatic measuring system. These blocks are the Arduino controller board, LED lighting system, the mechanical control system LEDs, LCD screen, the interrupt system and feeding system. To observe the emission spectrum of each of the LED has been used optical spectrum analyzer (OSA), which has been explained in detail. The Arduino programming code has been explained in flowchart form for an easy understanding. It has developed a manual to facilitate the use of system to any user, which has introduced a complete example of operation.
Resumo:
Low-cost, plastic-injected optics mix light from different color LED dies without a significant decrease in average brightness, simplifying luminaire design both optically and electronically. In solid-state lighting, high-flux and high-color rendering index (CRI) light engines may be achieved by arraying and mixing the light from different color dies or phosphors, or a combination of the two, in the LED package. However, these nonhomogeneous sources, when combined with luminaire optics, tend to produce patterns with undesirable artifacts such as spatial and angular nonuniformities and color separation.