867 resultados para KX observer


Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents a method for the estimation of thrust model parameters of uninhabited airborne systems using specific flight tests. Particular tests are proposed to simplify the estimation. The proposed estimation method is based on three steps. The first step uses a regression model in which the thrust is assumed constant. This allows us to obtain biased initial estimates of the aerodynamic coeficients of the surge model. In the second step, a robust nonlinear state estimator is implemented using the initial parameter estimates, and the model is augmented by considering the thrust as random walk. In the third step, the estimate of the thrust obtained by the observer is used to fit a polynomial model in terms of the propeller advanced ratio. We consider a numerical example based on Monte-Carlo simulations to quantify the sampling properties of the proposed estimator given realistic flight conditions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In a conventional ac motor drive using field-oriented control, a dc-link voltage, speed, and at least two current sensors are required. Hence, in the event of sensor failure, the performance of the drive system can be severely compromised. This paper presents a sensor fault-tolerant control strategy for interior permanent-magnet synchronous motor (IPMSM) drives. Three independent observers are proposed to estimate the speed, dc-link voltage, and currents of the machine. If a sensor fault is detected, the drive system isolates the faulty sensor while retaining the remaining functional ones. The signal is then acquired from the corresponding observer in order to maintain the operation of the drive system. The experimental results provided verify the effectiveness of the proposed approach.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper explores an emerging paradigm for HCI design research based primarily upon engagement, reciprocity and doing. Much HCI research begins with an investigatory and analytic ethnographic approach before translating to design. Design may come much later in the process and may never benefit the community that is researched. However in many settings it is difficult for researchers to access the privileged ethnographer position of observer and investigator. Moreover rapid ethnographic research often does not seem the best or most appropriate course of action. We draw upon a project working with a remote Australian Aboriginal community to illustrate an alternative approach in Indigenous research, where the notion of reciprocity is first and foremost. We argue that this can lead to sustainable designs, valid research and profound innovation. This paper received the ACM CHI Best Paper Award, which is awarded to the top 1% of papers submitted to the ACM CHI conference.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES To describe protocol and interobserver agreements of an instrument to evaluate nutrition and physical activity environments at child care. METHODS Interobserver data were collected from 9 child care centers, through direct observation and document review (17 observer pairs). RESULTS Mean agreement between observer pairs was 87.26% and 79.29% for the observation and document review, respectively. Items with lower agreement were primarily staff behavior, counting across the day/week, and policy classifications. CONCLUSIONS Although some revisions are required, the interobserver agreement for the environment and policy assessment and observation (EPAO instrument) appears to be quite good for assessing the nutrition and physical activity environment of child care centers.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents the modeling and motion-sensorless direct torque and flux control of a novel dual-airgap axial-flux permanent-magnet machine optimized for use in flywheel energy storage system (FESS) applications. Independent closed-loop torque and stator flux regulation are performed in the stator flux ( x-y) reference frame via two PI controllers. This facilitates fast torque dynamics, which is critical as far as energy charging/discharging in the FESS is concerned. As FESS applications demand high-speed operation, a new field-weakening algorithm is proposed in this paper. Flux weakening is achieved autonomously once the y-axis voltage exceeds the available inverter voltage. An inherently speed sensorless stator flux observer immune to stator resistance variations and dc-offset effects is also proposed for accurate flux and speed estimation. The proposed observer eliminates the rotary encoder, which in turn reduces the overall weight and cost of the system while improving its reliability. The effectiveness of the proposed control scheme has been verified by simulations and experiments on a machine prototype.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Interior permanent-magnet synchronous motors (IPMSMs) become attractive candidates in modern hybrid electric vehicles and industrial applications. Usually, to obtain good control performance, the electric drives of this kind of motor require one position, one dc link, and at least two current sensors. Failure of any of these sensors might lead to degraded system performance or even instability. As such, sensor fault resilient control becomes a very important issue in modern drive systems. This paper proposes a novel sensor fault detection and isolation algorithm based on an extended Kalman filter. It is robust to system random noise and efficient in real-time implementation. Moreover, the proposed algorithm is compact and can detect and isolate all the sensor faults for IPMSM drives. Thorough theoretical analysis is provided, and the effectiveness of the proposed approach is proven by extensive experimental results.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents the modeling and position-sensorless vector control of a dual-airgap axial flux permanent magnet (AFPM) machine optimized for use in flywheel energy storage system (FESS) applications. The proposed AFPM machine has two sets of three-phase stator windings but requires only a single power converter to control both the electromagnetic torque and the axial levitation force. The proper controllability of the latter is crucial as it can be utilized to minimize the vertical bearing stress to improve the efficiency of the FESS. The method for controlling both the speed and axial displacement of the machine is discussed. An inherent speed sensorless observer is also proposed for speed estimation. The proposed observer eliminates the rotary encoder, which in turn reduces the overall weight and cost of the system while improving its reliability. The effectiveness of the proposed control scheme has been verified by simulations and experiments on a prototype machine.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This presentation provides an overview of my PhD research, which links with the Institute for Urban Indigenous Health (IUIH) and its Deadly Choices team. In the presentation, I introduce my critique of mainstream health promotion practice, highlighting the need for decolonisation of health promotion and the opportunity to learn from health promotion practice that acknowledges Indigenous knowledge, skills and perspectives. I also overview my ethnographic research methodology, which enabled me to be a participant observer with IUIH health promotion practitioners. I canvas some of my findings to date, according to two key areas: the unique way Deadly Choices applies leadership as its model of health promotion practice; and the range of innovative engagement strategies they employed, including the Deadly Choices brand and social media. I conclude by highlighting the counter-narrative and contrast that Deadly Choices provides compared to traditional health promotion approaches with Indigenous people, and identify lessons for decolonisation of heath promotion more broadly.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction Standing radiographs are the ‘gold standard’ for clinical assessment of adolescent idiopathic scoliosis (AIS), with the Cobb Angle used to measure the severity and progression of the scoliotic curve. Supine imaging modalities can provide valuable 3D information on scoliotic anatomy, however, due to changes in gravitational loading direction, the geometry of the spine alters between the supine and standing position which in turn affects the Cobb Angle measurement. Previous studies have consistently reported a 7-10° [1-3] Cobb Angle increase from supine to standing, however, none have reported the effect of endplate pre-selection and which (if any) curve parameters affect the supine to standing Cobb Angle difference. Methods Female AIS patients with right-sided thoracic major curves were included in the retrospective study. Clinically measured Cobb Angles from existing standing coronal radiographs and fulcrum bending radiographs [4] were compared to existing low-dose supine CT scans taken within 3 months of the reference radiograph. Reformatted coronal CT images were used to measure Cobb Angle variability with and without endplate pre-selection (end-plates selected on the radiographs used on the CT images). Inter and intra-observer measurement variability was assessed. Multi-linear regression was used to investigate whether there was a relationship between supine to standing Cobb Angle change and patient characteristics (SPSS, v.21, IBM, USA). Results Fifty-two patients were included, with mean age of 14.6 (SD 1.8) years; all curves were Lenke Type 1 with mean Cobb Angle on supine CT of 42° (SD 6.4°) and 52° (SD 6.7°) on standing radiographs. The mean fulcrum bending Cobb Angle for the group was 22.6° (SD 7.5°). The 10° increase from supine to standing is consistent with existing literature. Pre-selecting vertebral endplates was found to increase the Cobb Angle difference by a mean 2° (range 0-9°). Multi-linear regression revealed a statistically significant relationship between supine to standing Cobb Angle change with: fulcrum flexibility (p=0.001), age (p=0.027) and standing Cobb Angle (p<0.001). In patients with high fulcrum flexibility scores, the supine to standing Cobb Angle change was as great as 20°.The 95% confidence intervals for intra-observer and inter-observer measurement variability were 3.1° and 3.6°, respectively. Conclusion There is a statistically significant relationship between supine to standing Cobb Angle change and fulcrum flexibility. Therefore, this difference can be considered a measure of spinal flexibility. Pre-selecting vertebral endplates causes only minor changes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This report studies an algebraic equation whose solution gives the image system of a source of light as seen by an observer inside a reflecting spherical surface. The equation is looked at numerically using GeoGebra. Under the hypothesis that our galaxy is enveloped by a reflecting interface this becomes a possible model for many mysterious extra galactic observations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A novel gray-box neural network model (GBNNM), including multi-layer perception (MLP) neural network (NN) and integrators, is proposed for a model identification and fault estimation (MIFE) scheme. With the GBNNM, both the nonlinearity and dynamics of a class of nonlinear dynamic systems can be approximated. Unlike previous NN-based model identification methods, the GBNNM directly inherits system dynamics and separately models system nonlinearities. This model corresponds well with the object system and is easy to build. The GBNNM is embedded online as a normal model reference to obtain the quantitative residual between the object system output and the GBNNM output. This residual can accurately indicate the fault offset value, so it is suitable for differing fault severities. To further estimate the fault parameters (FPs), an improved extended state observer (ESO) using the same NNs (IESONN) from the GBNNM is proposed to avoid requiring the knowledge of ESO nonlinearity. Then, the proposed MIFE scheme is applied for reaction wheels (RW) in a satellite attitude control system (SACS). The scheme using the GBNNM is compared with other NNs in the same fault scenario, and several partial loss of effect (LOE) faults with different severities are considered to validate the effectiveness of the FP estimation and its superiority.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction This investigation aimed to assess the consistency and accuracy of radiation therapists (RTs) performing cone beam computed tomography (CBCT) alignment to fiducial markers (FMs) (CBCTFM) and the soft tissue prostate (CBCTST). Methods Six patients receiving prostate radiation therapy underwent daily CBCTs. Manual alignment of CBCTFM and CBCTST was performed by three RTs. Inter-observer agreement was assessed using a modified Bland–Altman analysis for each alignment method. Clinically acceptable 95% limits of agreement with the mean (LoAmean) were defined as ±2.0 mm for CBCTFM and ±3.0 mm for CBCTST. Differences between CBCTST alignment and the observer-averaged CBCTFM (AvCBCTFM) alignment were analysed. Clinically acceptable 95% LoA were defined as ±3.0 mm for the comparison of CBCTST and AvCBCTFM. Results CBCTFM and CBCTST alignments were performed for 185 images. The CBCTFM 95% LoAmean were within ±2.0 mm in all planes. CBCTST 95% LoAmean were within ±3.0 mm in all planes. Comparison of CBCTST with AvCBCTFM resulted in 95% LoA of −4.9 to 2.6, −1.6 to 2.5 and −4.7 to 1.9 mm in the superior–inferior, left–right and anterior–posterior planes, respectively. Conclusions Significant differences were found between soft tissue alignment and the predicted FM position. FMs are useful in reducing inter-observer variability compared with soft tissue alignment. Consideration needs to be given to margin design when using soft tissue matching due to increased inter-observer variability. This study highlights some of the complexities of soft tissue guidance for prostate radiation therapy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The close relationship between rain and lightning is well known. However, there are numerous documented observations of heavy rain accompanied by little or no lightning activity (Williams et al, 1992; Jayaratne, 1993). Kuleshov et al (2002) studied thunderstorm distribution and frequency in Australia and concluded that thunderstorm frequency (as expressed by number of thunder-days) in Australia does not, in general, appear to vary in any consistent way with rainfall. However, thunder-days describe occurrence of thunderstorms as heard by an observer, and therefore could be only proxy data to evaluate actual lightning activity (i.e. number of total or cloud-to-ground flashes). Field experiments have demonstrated a strong increase in lightning activity with convective available potential energy (CAPE). It has also been shown that CAPE increases linearly with potential wet bulb temperature, Tw (Williams et al, 1992). In this study, we examine the relationship between lightning ground flash incidence and the two parameters – surface rainfall and surface wet bulb maximum temperature for selected localities around Australia...

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background At Queensland University of Technology, student radiation therapists receive regular feedback from clinical staff relating to clinical interpersonal skills. Although this is of great value, there is anecdotal evidence that students communicate differently with patients when under observation. Purpose The aim of this pilot was to counter this perceived observer effect by allowing patients to provide students with additional feedback. Materials and methods Radiotherapy patients from two departments were provided with anonymous feedback forms relating to aspects of student interpersonal skills. Clinical assessors, mentors and students were also provided with feedback forms, including questions about the role of patient feedback. Patient perceptions of student performance were correlated with staff feedback and assessment scores. Results Results indicated that the feedback was valued by both students and patients. Students reported that the additional dimension focused them on communication, set goals for development and increased motivation. These changes derived from both feedback and study participation, suggesting that the questionnaires could be a useful teaching tool. Patients scored more generously than mentors, although there was agreement in relative grading. Conclusions The anonymous questionnaire is a convenient and valuable method of gathering patient feedback on students. Future iterations will determine the optimum timing for this method of feedback.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This research draws on theories of emergence to inform the creation of an artistic and direct visualization. This is an interactive artwork and drawing tool for creative participant experiences. As is discussed, emergence is characteristically creative. It is also debated across and within disciplines, resulting in a range of understandings as well as models. This paper shows how one field’s understanding of emergence (complexity theory) can be used to facilitate emergence in another domain (design research) and, importantly provide the opportunity for someone to act creatively. This paper begins with a brief review of some theories of emergence to show how they interrelate and can effect the perception of emergent structures in an observer, and, correspondingly, the design for creative experience. This is subsequently demonstrated in the second section of the paper where an interactive artwork and drawing application, Of me with me, is presented. This artwork by the author was created during collaboration with community artists from Cerebral Palsy League. The discussion covers the application of emergence theories to create this visualization in order facilitate the perception of structures and creative behaviours in a participant and to facilitate self-efficacy in the community artist user group.