901 resultados para Hydrophobic chromatography


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Because of the large variability in the pharmacokinetics of anti-HIV drugs, therapeutic drug monitoring in patients may contribute to optimize the overall efficacy and safety of antiretroviral therapy. An LC-MS/MS method for the simultaneous assay in plasma of the novel antiretroviral agents rilpivirine (RPV) and elvitegravir (EVG) has been developed to that endeavor. Plasma samples (100 μL) extraction is performed by protein precipitation with acetonitrile, and the supernatant is subsequently diluted 1:1 with 20-mM ammonium acetate/MeOH 50:50. After reverse-phase chromatography, quantification of RPV and EVG, using matrix-matched calibration samples, is performed by electrospray ionization-triple quadrupole mass spectrometry by selected reaction monitoring detection using the positive mode. The stable isotopic-labeled compounds RPV-(13) C6 and EVG-D6 were used as internal standards. The method was validated according to FDA recommendations, including assessment of extraction yield, matrix effects variability (<6.4%), as well as EVG and RPV short and long-term stability in plasma. Calibration curves were validated over the clinically relevant concentrations ranging from 5 to 2500 ng/ml for RPV and from 50 to 5000 ng/ml for EVG. The method is precise (inter-day CV%: 3-6.3%) and accurate (3.8-7.2%). Plasma samples were found to be stable (<15%) in all considered conditions (RT/48 h, +4°C/48 h, -20°C/3 months and 60°C/1 h). Selected metabolite profiles analysis in patients' samples revealed the presence of EVG glucuronide, that was well separated from parent EVG, allowing to exclude potential interferences through the in-source dissociation of glucuronide to parent drug. This new, rapid and robust LCMS/MS assay for the simultaneous quantification of plasma concentrations of these two major new anti-HIV drugs EVG and RPV offers an efficient analytical tool for clinical pharmacokinetics studies and routine therapeutic drug monitoring service. Copyright © 2013 John Wiley & Sons, Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

D-lactic acid in urine originates mainly from bacterial production in the intestinal tract. Increased D-lactate excretion as observed in patients affected by short bowel syndrome or necrotizing enterocolitis reflects D-lactic overproduction. Therefore, there is a need for a reliable and sensitive method able to detect D-lactic acid even at subclinical elevation levels. A new and highly sensitive method for the simultaneous determination of L- and D-lactic acid by a two-step procedure has been developed. This method is based on the concentration of lactic acid enantiomers from urine by supported liquid extraction followed by high-performance liquid chromatography-tandem mass spectrometry. The separation was achieved by the use of an Astec Chirobiotic? R chiral column under isocratic conditions. The calibration curves were linear over the ranges of 2-400 and 0.5-100 µmol/L respectively for L- and D-lactic acid. The limit of detection of D-lactic acid was 0.125 µmol/L and its limit of quantification was 0.5 µmol/L. The overall accuracy and precision were well within 10% of the nominal values. The developed method is suitable for production of reference values in children and could be applied for accurate routine analysis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Agricultural workers are exposed to folpet, but biomonitoring data are limited. Phthalimide (PI), phthalamic acid (PAA), and phthalic acid (PA) are the ring metabolites of this fungicide according to animal studies, but they have not yet been measured in human urine as metabolites of folpet, only PA as a metabolite of phthalates. The objective of this study was thus to develop a reliable gas chromatography-tandem mass spectrometry (GC-MS) method to quantify the sum of PI, PAA, and PA ring-metabolites of folpet in human urine. Briefly, the method consisted of adding p-methylhippuric acid as an internal standard, performing an acid hydrolysis at 100 °C to convert ring-metabolites into PA, purifying samples by ethyl acetate extraction, and derivatizing with N,O-bis(trimethylsilyl)trifluoro acetamide prior to GC-MS analysis. The method had a detection limit of 60.2 nmol/L (10 ng/mL); it was found to be accurate (mean recovery, 97%), precise (inter- and intra-day percentage relative standard deviations <13%), and with a good linearity (R (2) > 0.98). Validation was conducted using unexposed peoples urine spiked at concentrations ranging from 4.0 to 16.1 μmol/L, along with urine samples of volunteers dosed with folpet, and of exposed workers. The method proved to be (1) suitable and accurate to determine the kinetic profile of PA equivalents in the urine of volunteers orally and dermally administered folpet and (2) relevant for the biomonitoring of exposure in workers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this article, selected examples of applications of liquid chromatography coupled to mass spectrometry are given. The examples include the analysis of i) impurities in manufactured, pharmaceutical or synthesis products, ii) polyphenols in natural products, and iii) phytohormones in plant extracts. Finally, examples of applications of molecular characterization via flow injection analysis by electron spray ionization mass spectrometry (ESI-MS) are also given.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The general strategy to perform anti-doping analyses of urine samples starts with the screening for a wide range of compounds. This step should be fast, generic and able to detect any sample that may contain a prohibited substance while avoiding false negatives and reducing false positive results. The experiments presented in this work were based on ultra-high-pressure liquid chromatography coupled to hybrid quadrupole time-of-flight mass spectrometry. Thanks to the high sensitivity of the method, urine samples could be diluted 2-fold prior to injection. One hundred and three forbidden substances from various classes (such as stimulants, diuretics, narcotics, anti-estrogens) were analysed on a C(18) reversed-phase column in two gradients of 9min (including two 3min equilibration periods) for positive and negative electrospray ionisation and detected in the MS full scan mode. The automatic identification of analytes was based on retention time and mass accuracy, with an automated tool for peak picking. The method was validated according to the International Standard for Laboratories described in the World Anti-Doping Code and was selective enough to comply with the World Anti-Doping Agency recommendations. In addition, the matrix effect on MS response was measured on all investigated analytes spiked in urine samples. The limits of detection ranged from 1 to 500ng/mL, allowing the identification of all tested compounds in urine. When a sample was reported positive during the screening, a fast additional pre-confirmatory step was performed to reduce the number of confirmatory analyses.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple method determining airborne monoethanolamine has been developed. Monoethanolamine determination has traditionally been difficult due to analytical separation problems. Even in recent sophisticated methods, this difficulty remains as the major issue often resulting in time-consuming sample preparations. Impregnated glass fiber filters were used for sampling. Desorption of monoethanolamine was followed by capillary GC analysis and nitrogen phosphorous selective detection. Separation was achieved using a specific column for monoethanolamines (35% diphenyl and 65% dimethyl polysiloxane). The internal standard was quinoline. Derivatization steps were not needed. The calibration range was 0.5-80 μg/mL with a good correlation (R(2) = 0.996). Averaged overall precisions and accuracies were 4.8% and -7.8% for intraday (n = 30), and 10.5% and -5.9% for interday (n = 72). Mean recovery from spiked filters was 92.8% for the intraday variation, and 94.1% for the interday variation. Monoethanolamine on stored spiked filters was stable for at least 4 weeks at 5°C. This newly developed method was used among professional cleaners and air concentrations (n = 4) were 0.42 and 0.17 mg/m(3) for personal and 0.23 and 0.43 mg/m(3) for stationary measurements. The monoethanolamine air concentration method described here was simple, sensitive, and convenient both in terms of sampling and analytical analysis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ethyl glucuronide (EtG) is a minor and direct metabolite of ethanol. EtG is incorporated into the growing hair allowing retrospective investigation of chronic alcohol abuse. In this study, we report the development and the validation of a method using gas chromatography-negative chemical ionization tandem mass spectrometry (GC-NCI-MS/MS) for the quantification of EtG in hair. EtG was extracted from about 30 mg of hair by aqueous incubation and purified by solid-phase extraction (SPE) using mixed mode extraction cartridges followed by derivation with perfluoropentanoic anhydride (PFPA). The analysis was performed in the selected reaction monitoring (SRM) mode using the transitions m/z 347-->163 (for the quantification) and m/z 347-->119 (for the identification) for EtG, and m/z 352-->163 for EtG-d(5) used as internal standard. For validation, we prepared quality controls (QC) using hair samples taken post mortem from 2 subjects with a known history of alcoholism. These samples were confirmed by a proficiency test with 7 participating laboratories. The assay linearity of EtG was confirmed over the range from 8.4 to 259.4 pg/mg hair, with a coefficient of determination (r(2)) above 0.999. The limit of detection (LOD) was estimated with 3.0 pg/mg. The lower limit of quantification (LLOQ) of the method was fixed at 8.4 pg/mg. Repeatability and intermediate precision (relative standard deviation, RSD%), tested at 4 QC levels, were less than 13.2%. The analytical method was applied to several hair samples obtained from autopsy cases with a history of alcoholism and/or lesions caused by alcohol. EtG concentrations in hair ranged from 60 to 820 pg/mg hair.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Propane can be responsible for several types of lethal intoxication and explosions. Quantifying it would be very helpful to determine in some cases the cause of death. Some gas chromatography-mass spectrometry (GC-MS) methods of propane measurements do already exist. The main drawback of these GC-MS methods described in the literature is the absence of a specific propane internal standard necessary for accurate quantitative analysis. The main outcome of the following study was to provide an innovative Headspace-GC-MS method (HS-GC-MS) applicable to the routine determination of propane concentration in forensic toxicology laboratories. To date, no stable isotope of propane is commercially available. The development of an in situ generation of standards is thus presented. An internal-labeled standard gas (C3DH7) is generated in situ by the stoichiometric formation of propane by the reaction of deuterated water (D2O) with Grignard reagent propylmagnesium chloride (C3H7MgCl). The method aims to use this internal standard to quantify propane concentrations and, therefore, to obtain precise measurements. Consequently, a complete validation with an accuracy profile according to two different guidelines, the French Society of Pharmaceutical Sciences and Techniques (SFSTP) and the Gesellschaft für toxikologische und Forensische Chemie (GTFCh), is presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: The diagnosis of pheochromocytoma relies on the measurement of plasma free metanephrines assay whose reliability has been considerably improved by ultra-high pressure liquid chromatography tandem mass spectrometry (UHPLC-MS/MS). Here we report an analytical interference occurring between 4-hydroxy-3-methoxymethamphetamine (HMMA), a metabolite of 3,4-methylenedioxymethamphetamine (MDMA, "Ecstasy"), and normetanephrine (NMN) since they share a common pharmacophore resulting in the same product ion after fragmentation. DESIGN AND METHODS: Synthetic HMMA was spiked into plasma samples containing various concentrations of NMN and the intensity of the interference was determined by UPLC-MS/MS before and after improvement of the analytical method. RESULTS: Using a careful adjustment of chromatographic conditions including the change of the UPLC analytical column, we were able to distinguish both compounds. HMMA interference for NMN determination should be seriously considered since MDMA activates the sympathetic nervous system and if confounded with NMN may lead to false-positive tests when performing a differential diagnostic of pheochromocytoma.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recent studies show that the composition of fingerprint residue varies significantly from the same donor as well as between donors. This variability is a major drawback in latent print dating issues. This study aimed, therefore, at the definition of a parameter that is less variable from print to print, using a ratio of peak area of a target compound degrading over time divided by the summed area of peaks of more stable compounds also found in latent print residues.Gas chromatography-mass spectrometry (GC/MS) analysis of the initial lipid composition of latent prints identifies four main classes of compounds that can be used in the definition of an aging parameter: fatty acids, sterols, sterol precursors, and wax esters (WEs). Although the entities composing the first three groups are quite well known, those composing WEs are poorly reported. Therefore, the first step of the present work was to identify WE compounds present in latent print residues deposited by different donors. Of 29 WEs recorded in the chromatograms, seven were observed in the majority of samples.The identified WE compounds were subsequently used in the definition of ratios in combination with squalene and cholesterol to reduce the variability of the initial composition between latent print residues from different persons and more particularly from the same person. Finally, the influence of a latent print enhancement process on the initial composition was studied by analyzing traces after treatment with magnetic powder, 1,2-indanedione, and cyanoacrylate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Plasma catecholamines provide a reliable biomarker of sympathetic activity. The low circulating concentrations of catecholamines and analytical interferences require tedious sample preparation and long chromatographic runs to ensure their accurate quantification by HPLC with electrochemical detection. Published or commercially available methods relying on solid phase extraction technology lack sensitivity or require derivatization of catecholamine by hazardous reagents prior to tandem mass spectrometry (MS) analysis. Here, we manufactured a novel 96-well microplate device specifically designed to extract plasma catecholamines prior to their quantification by a new and highly sensitive ultraperformance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method. Processing time, which included sample purification on activated aluminum oxide and elution, is less than 1 h per 96-well microplate. The UPLC-MS/MS analysis run time is 2.0 min per sample. This UPLC-MS/MS method does not require a derivatization step, reduces the turnaround time by 10-fold compared to conventional methods used for routine application, and allows catecholamine quantification in reduced plasma sample volumes (50-250 μL, e.g., from children and mice).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple method using liquid chromatography-linear ion trap mass spectrometry for simultaneous determination of testosterone glucuronide (TG), testosterone sulfate (TS), epitestosterone glucuronide (EG) and epitestosterone sulfate (ES) in urine samples was developed. For validation purposes, a urine containing no detectable amount of TG, TS and EG was selected and fortified with steroid conjugate standards. Quantification was performed using deuterated testosterone conjugates to correct for ion suppression/enhancement during ESI. Assay validation was performed in terms of lower limit of detection (1-3ng/mL), recovery (89-101%), intraday precision (2.0-6.8%), interday precision (3.4-9.6%) and accuracy (101-103%). Application of the method to short-term stability testing of urine samples at temperature ranging from 4 to 37 degrees C during a time-storage of a week lead to the conclusion that addition of sodium azide (10mg/mL) is required for preservation of the analytes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recent ink dating methods focused mainly on changes in solvent amounts occurring over time. A promising method was developed at the Landeskriminalamt of Munich using thermal desorption (TD) followed by gas chromatography / mass spectrometry (GC/MS) analysis. Sequential extractions of the phenoxyethanol present in ballpoint pen ink entries were carried out at two different temperatures. This method is applied in forensic practice and is currently implemented in several laboratories participating to the InCID group (International Collaboration on Ink Dating). However, harmonization of the method between the laboratories proved to be a particularly sensitive and time consuming task. The main aim of this work was therefore to implement the TD-GC/MS method at the Bundeskriminalamt (Wiesbaden, Germany) in order to evaluate if results were comparable to those obtained in Munich. At first validation criteria such as limits of reliable measurements, linearity and repeatability were determined. Samples were prepared in three different laboratories using the same inks and analyzed using two TDS-GC/MS instruments (one in Munich and one in Wiesbaden). The inter- and intra-laboratory variability of the ageing parameter was determined and ageing curves were compared. While inks stored in similar conditions yielded comparable ageing curves, it was observed that significantly different storage conditions had an influence on the resulting ageing curves. Finally, interpretation models, such as thresholds and trend tests, were evaluated and discussed in view of the obtained results. Trend tests were considered more suitable than threshold models. As both approaches showed limitations, an alternative model, based on the slopes of the ageing curves, was also proposed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rapport de synthèse1. Partie de laboratoireCette première étude décrit le développement et la validation, selon les standards internationaux, de deux techniques de mesure des concentrations sanguines de voriconazole, un nouvel agent antifongique à large spectre: 1) la chromatographic en phase liquide à haute pression et 2) le bio-essai utilisant une souche mutante de Candida hypersensible au voriconazole. Ce travail a aussi permis de mettre en évidence une importante et imprévisible variabilité inter- et intra-individuelle des concentrations sanguines de voriconazole malgré l'utilisation des doses recommandées par le fabriquant. Ce travail a été publié dans un journal avec "peer-review": "Variability of voriconazole plasma levels measured by new high- performance liquid chromatography and bioassay methods" by A. Pascual, V. Nieth, T. Calandra, J. Bille, S. Bolay, L.A. Decosterd, T. Buclin, P.A. Majcherczyk, D. Sanglard, 0. Marchetti. Antimicrobial Agents Chemotherapy, 2007; 51:137-432. Partie CliniqueCette deuxième étude a évalué de façon prospective l'impact clinique des concentrations sanguines de voriconazole sur l'efficacité et sécurité thérapeutique chez des patients atteints d'infections fongiques. Des concentrations sanguines élevées étaient significativement associés à la survenue d'une toxicité neurologique (encéphalopathie avec confusion, hallucinations et myoclonies) et des concentrations sanguines basses à une réponse insuffisante au traitement antifongique (persistance ou progression des signes cliniques et radiologiques de l'infection). Dans la majorité des cas, un ajustement de la dose de voriconazole, sur la base des concentrations mesurées, a abouti à une récupération neurologique complète ou à une résolution de l'infection, respectivement. Ce travail a été publié dans un journal avec "peer-review": " Voriconazole Therapeutic Drug Monitoring in Patients with Invasive Mycoses Improves Efficacy and Safety Outcomes" by A. Pascual, T. Calandra, S. Bolay, T. Buclin, J. Bille, and O. Marchetti. Clinical Infectious Diseases, 2008 January 15; 46(2): 201-11.Ces deux études, financées de façon conjointe par un "grant" international de la Société suisse d'infectiologie et la Société internationale de maladies infectieuses et par la Fondation pour le progrès en microbiologie médicale et maladies infectieuses (FAMMID, Lausanne), ont été réalisées au sein du Service des Maladies Infectieuses, Département de Médecine, au CHUV, en étroite collaboration avec la Division de Pharmacologie Clinique, Département de Médecine, au CHUV et l'Institut de Microbiologie du CHUV et de l'Université de Lausanne.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Access to new biological sources is a key element of natural product research. A particularly large number of biologically active molecules have been found to originate from microorganisms. Very recently, the use of fungal co-culture to activate the silent genes involved in metabolite biosynthesis was found to be a successful method for the induction of new compounds. However, the detection and identification of the induced metabolites in the confrontation zone where fungi interact remain very challenging. To tackle this issue, a high-throughput UHPLC-TOF-MS-based metabolomic approach has been developed for the screening of fungal co-cultures in solid media at the petri dish level. The metabolites that were overexpressed because of fungal interactions were highlighted by comparing the LC-MS data obtained from the co-cultures and their corresponding mono-cultures. This comparison was achieved by subjecting automatically generated peak lists to statistical treatments. This strategy has been applied to more than 600 co-culture experiments that mainly involved fungal strains from the Fusarium genera, although experiments were also completed with a selection of several other filamentous fungi. This strategy was found to provide satisfactory repeatability and was used to detect the biomarkers of fungal induction in a large panel of filamentous fungi. This study demonstrates that co-culture results in consistent induction of potentially new metabolites.