922 resultados para High-frequency data


Relevância:

100.00% 100.00%

Publicador:

Resumo:

One of the mechanisms proposed for heating the corona above solar active regions is the damping of magnetohydrodynamic (MHD) waves. Continuing on previous work, we provide observational evidence for the existence of high-frequency MHD waves in coronal loops observed during the August 1999 total solar eclipse. A wavelet analysis is used to identify twenty 4 x 4 arcsec(2) areas showing intensity oscillations. All detections lie in the frequency range 0.15 - 0.25 Hz (7 - 4 s), last for at least 3 periods at a confidence level of more than 99% and arise just outside known coronal loops. This leads us to suggest that they occur in low emission-measure or different temperature loops associated with the active region.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Solar Eclipse Corona Imaging System (SECIS) was used to record high-cadence observations of the solar corona during the total solar eclipse of 1999 August 11. During the 2 min 23.5 s of totality, 6364 images were recorded simultaneously in each of the two channels: a white light channel, and the Fe xiv (5303 Angstrom) 'green line' channel (T similar to2 MK). Here we report initial results from the SECIS experiment, including the discovery of a 6-s intensity oscillation in an active region coronal loop.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The ionization dynamics of H2 + exposed to high-intensity, high-frequency, ultrashort laser pulses is investigated with two theoretical approaches. The time-dependent Schrödinger equation is solved by a direct numerical method, and a simple two-center interference-diffraction model is studied. The energy and angular distributions of the photoelectron for various internuclear distances and relative orientations between the internuclear axis of the molecule and the polarization of the field are calculated. The main features of the photoelectron spectrum pattern are described well by the interference-diffraction model, and excellent quantitative agreement between the two methods is found. The effect of quantal vibration on the photoelectron spectrum is also calculated. We find that vibrational average produces some broadening of the main features, but that the patterns remain clearly distinguishable.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aim: The aim of this study is to assess the murine heart of normal embryos, neonates, and juveniles using high-frequency ultrasound. Methods: Diastolic function was measured with E/A ratio (E wave velocity/A wave velocity) and isovolumetric relaxation time (IRT), systolic function with isovolumetric contraction time (ICT), percentage fractional shortening (FS%), percentage ejection fraction (EF%). Global cardiac performance was quantified using myocardial performance index (MPI). Results: Isovolumetric relaxation time remained stable from E10.5 to 3 weeks. Systolic function (ICT) improved with gestation and remained stable from E18.5 onward. Myocardial performance index showed improvement in embryonic lift (0.82-0.63) and then stabilized from 1 to 3 week (0.60-0.58). Percentage ejection fraction remained high during gestation (77%-69%) and then decreased from the neonate to juvenile (68%-51%). Conclusion: The ultrasound biomicroscope allows for noninvasive in-depth assessment of cardiac function of embryos and pups. Detailed physiological and functional cardiac function readouts can be obtained, which is invaluable for comparison to mouse models of disease.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Ex vivo T cell depletion of allogeneic grafts is associated with a high (up to 80%) rate of mixed chimerism (MC) posttransplantation. The number of transplanted progenitor cells is an important factor in achieving complete donor chimerism in the T cell depletion setting. Use of granulocyte colony-stimulating factor (G-CSF) peripheral blood allografts allows the administration of large numbers of CD34+ cells. We studied the chimeric status of 13 patients who received allogeneic CD34+-selected peripheral blood progenitor cell transplants (allo-PBPCTs/CD34+) from HLA-identical sibling donors. Patients were conditioned with cyclophosphamide (120 mg/kg) and total-body irradiation (13 Gy in four fractions). Apheresis products were T cell-depleted by the immunoadsorption avidin-biotin method. The median number of CD34+ and CD3+ cells infused was 2.8x10(6)/kg (range 1.9-8.6x10(6)/kg) and 0.4x10(6)/kg (range 0.3-1x10(6)/kg), respectively. Molecular analysis of the engraftment was performed using polymerase chain reaction (PCR) amplification of highly polymorphic short tandem repeat (PCR-STR) sequences in peripheral blood samples. MC was detected in two (15%) of 13 patients. These two patients relapsed at 8 and 10 months after transplant, respectively. The remaining 11 patients showed complete donor chimerism and were in clinical remission after a maximum follow-up period of 24 months (range 6-24 months). These results were compared with those obtained in 10 patients who were treated with T cell-depleted bone marrow transplantation by means of elutriation and who received the same conditioning treatment and similar amounts of CD3+ cells (median 0.45x10(6)/kg; not significant) but a lower number of CD34+ cells (median 0.8x10(6)/kg; p = 0.001). MC was documented in six of 10 patients (60%), which was significantly higher than in the allo-PBPCT/CD34+ group (p = 0.04). We conclude that a high frequency of complete donor chimerism is achieved in patients receiving allo-PBPCT/CD34+ and that this is most likely due to the high number of progenitor cells administered.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work is dedicated to comparison of open source as well as proprietary transport protocols for highspeed data transmission via IP networks. The contemporary common TCP needs significant improvement since it was developed as general-purpose transport protocol and firstly introduced four decades ago. In nowadays networks, TCP fits not all communication needs that society has. Caused of it another transport protocols have been developed and successfully used for e.g. Big Data movement. In scope of this research the following protocols have been investigated for its efficiency on 10Gbps links: UDT, RBUDP, MTP and RWTP. The protocols were tested under different impairments such as Round Trip Time up to 400 ms and packet losses up to 2%. Investigated parameters are the data rate under different conditions of the network, the CPU load by sender andreceiver during the experiments, size of feedback data, CPU usage per Gbps and the amount of feedback data per GiByte of effectively transmitted data. The best performance and fair resources consumption was observed by RWTP. From the opensource projects, the best behavior is showed by RBUDP.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We assess the predictive ability of three VPIN metrics on the basis of two highly volatile market events of China, and examine the association between VPIN and toxic-induced volatility through conditional probability analysis and multiple regression. We examine the dynamic relationship on VPIN and high-frequency liquidity using Vector Auto-Regression models, Granger Causality tests, and impulse response analysis. Our results suggest that Bulk Volume VPIN has the best risk-warning effect among major VPIN metrics. VPIN has a positive association with market volatility induced by toxic information flow. Most importantly, we document a positive feedback effect between VPIN and high-frequency liquidity, where a negative liquidity shock boosts up VPIN, which, in turn, leads to further liquidity drain. Our study provides empirical evidence that reflects an intrinsic game between informed traders and market makers when facing toxic information in the high-frequency trading world.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The thesis deals with the preparation and dielectric characterization of Poly aniline and its analogues in ISM band frequency of 2-4 GHz that includes part of the microwave region (300 MHz to 300 GHz) of the electromagnetic spectrum and an initial dielectric study in the high frequency [O.05MHz-13 MHz]. PolyaniIine has been synthesized by an in situ doping reaction under different temperature and in the presence of inorganic dopants such as HCl H2S04, HN03, HCl04 and organic dopants such as camphorsulphonic acid [CSA], toluenesulphonic acid {TSA) and naphthalenesulphonic acid [NSA]. The variation in dielectric properties with change in reaction temperature, dopants and frequency has been studied. The effect of codopants and microemulsions on the dielectric properties has also been studied in the ISM band. The ISM band of frequencies (2-4 GHz) is of great utility in Industrial, Scientific and Medical (ISM) applications. Microwave heating is a very efficient method of heating dielectric materials and is extensively used in industrial as well as household heating applications.