964 resultados para Doppler echography
Resumo:
Background. Abdominal porto-systemic collaterals (APSC) on Color-Doppler ultrasound are a frequent finding in portal hypertensive cirrhotic patients. In patients with cirrhosis, an HVPG ≥ 16mmHg has been shown to be associated with increased mortality in two studies. Non-invasive indicators of HVPG ≥ 16 mmHg might define a subgroup of high-risk patients, but data on this aspect are lacking. Aims. We aimed to investigate whether HVPG predicts mortality in patients with clinically significant portal hypertension, and if APSC may predict a severe portal hypertensive state (i.e. HVPG≥16mmHg) in patients with cirrhosis and untreated portal hypertension. Methods. We analysed paired HVPG and ultrasonographic data of 86 untreated portal hypertensive cirrhotic patients. On abdominal echo-color-Doppler data on presence, type and number of APSC were prospectively collected. HVPG was measured following published guidelines. Clinical, laboratory and endoscopic data were available in all cases. First decompensation of cirrhosis and liver-disease related mortality on follow-up (mean 28±20 months) were recorded. Results. 73% of patients had compensated cirrhosis, while 27% were decompensated. All patients had an HVPG≥10 mmHg (mean 17.8±5.1 mmHg). 58% of compensated patients and 82% of decompensated patients had an HVPG over 16 mmHg. 25% had no varices, 28% had small varices, and 47% had medium/large varices. HVPG was higher in patients with esophageal varices vs. patients without varices (19.0±4.8 vs. 14.1±4.2mmHg, p<0.0001), and correlated with Child-Pugh score (R=0.494,p=0.019). 36 (42%) patients had APSC were more frequent in decompensated patients (60% vs. 35%, p=0.03) and in patients with esophageal varices (52% vs. 9%,p=0.001). HVPG was higher in patients with APSC compared with those without PSC (19.9± 4.6 vs. 16.2± 4.9mmHg, p=0.001). The prevalence of APSC was higher in patients with HVPG≥16mmHg vs. those with HVPG<16mmHg (57% vs. 13%,p<0.0001). Decompensation was significantly more frequent in patients with HVPG≥16mmHg vs. HVPG<16mmHg (35.1% vs. 11.5%, p=0.02). On multivariate analysis only HVPG and bilirubin were independent predictors of first decompensation. 10 patients died during follow-up. All had an HVPG≥16 mmHg (26% vs. 0% in patients with HVPG <16mmHg,p=0.04). On multivariate analysis only MELD score and HVPG ≥16mmHg were independent predictors of mortality. In compensated patients the detection of APSC predicted an HVPG≥16mmHg with 92% specificity, 54% sensitivity, positive and negative likelihood ratio 7.03 and 0.50, which implies that the demonstration of APSC on ultrasound increased the probability of HVPG≥16mmHg from 58% to 91%. Conclusions. HVPG maintains an independent prognostic value in the subset of patients with cirrhosis and clinically significant portal hypertension. The presence of APSC is a specific indicator of severe portal hypertension in patients with cirrhosis. Detection of APSC on ultrasound allows the non-invasive identification of a subgroup of compensated patients with bad prognosis, avoiding the invasive measurement of HVPG.
Resumo:
Background: Cardiovascular disease (CVD) is a common cause of morbidity and mortality in childhood chronic kidney disease (CKD). Left ventricular hypertrophy (LVH) is known to be one of the earliest events in CVD development. Left ventricular diastolic function (DF) is thought to be also impaired in children with CKD. Tissue Doppler imaging (TDI) provide an accurate measure of DF and is less load dependent than conventional ECHO. Aim: To evaluate the LV mass and the DF in a population of children with CKD. Methods: 37 patients, median age: 10.4 (3.3-19.8); underlying renal disease: hypo/dysplasia (N=28), nephronophthisis (N=4), Alport (N=2), ARPKD (N=3), were analyzed. Thirty-eight percent of the patients were on stage 1-2 of CKD, 38% on stage 3, 16% on stage 4. Three patients were on dialysis. The most frequent factors related to CVD in CKD have been studied. LVH has been defined as a left ventricular mass index (LVMI) more than 35.7 g/h2,7. Results: Twenty-five patients (81%) had a LVH. LVMI and diastolic function index (E’/A’) were significantly related to the glomerular filtration rate (p<0.003 and p<0.004). Moreover the LVMI was correlated with the phosphorus and the hemoglobin level (p<0.0001 and p<0.004). LVH was present since the first stages of CKD (58% of patients were on stages 1-2). Early-diastolic myocardial velocity was reduced in 73% of our patients. We didn’t find any correlation between LVH and systemic hypertension. Conclusion: ECHO evaluation with TDI is suggested also in children prior to dialysis and with a normal blood pressure. If LVH is diagnosed, a periodic follow-up is necessary with the treatment of the modifiable risk factors (hypertension, disturbances of calcium, phosphorus and PTH, anemia ).
Resumo:
In questo lavoro ci siamo posti come obiettivo lo studio della disfunzione atrio-ventricolare mediante tecniche ecocardiografiche avanzate (come il Tissue Doppler Imaging - TDI) in cani affetti da malattia mitralica cronica (MVD). Una prima parte è volta alla valutazione della funzionalità diastolica del ventricolo destro. Ci siamo proposti di analizzare la funzione del ventricolo destro in cani affetti da malattia del cuore sinistro per comprendere se quest’ultima possa condizionare direttamente la performance del settore cardiaco controlaterale. I risultati più importanti che abbiamo riscontrato sono: l’assenza di differenze significative nella disfunzione sisto-diastolica del ventricolo destro in cani con MVD a diverso stadio; la diretta correlazione tra le variabili TDI di funzionalità del ventricolo destro con il grado di disfunzione del ventricolo sinistro, come indicatori di interdipendenza ventricolare; ed infine il riscontro di una maggior tendenza ad alterazioni diastoliche del ventricolo sinistro in cani con ipertensione polmonare. A quest’ultimo proposito, per quanto riguarda le variabili TDI, il rapporto E/e’ dell’anulus mitralico laterale e settale è risultato avere una differenza significativa tra i cani con ipertensione polmonare e quelli privi di ipertensione polmonare (P<0,01). Nel secondo studio abbiamo applicato il TDI per l’analisi della funzione sisto-diastolica dell’atrio sinistro. Il lavoro è stato articolato in una parte di validazione della metodica su cani normali ed una su animali affetti da MDV. I risultati ottenuti mostrano che la valutazione ecocardiografica delle proprietà di deformazione dell’atrio sinistro basata sul TDI è attuabile e riproducibile nel cane. Abbiamo fornito dei valori di normalità per questa specie e confrontato questi dati con quelli ricavati in cani portatori di MVD. Le differenza tra le varie classi di malattia, nei diversi gradi di dilatazione atriale, sono risultate limitate, ma abbiamo individuato delle correlazioni tra i parametri TDI ed alcune variabili di funzionalità atriale.
Resumo:
The aim of this work is to present various aspects of numerical simulation of particle and radiation transport for industrial and environmental protection applications, to enable the analysis of complex physical processes in a fast, reliable, and efficient way. In the first part we deal with speed-up of numerical simulation of neutron transport for nuclear reactor core analysis. The convergence properties of the source iteration scheme of the Method of Characteristics applied to be heterogeneous structured geometries has been enhanced by means of Boundary Projection Acceleration, enabling the study of 2D and 3D geometries with transport theory without spatial homogenization. The computational performances have been verified with the C5G7 2D and 3D benchmarks, showing a sensible reduction of iterations and CPU time. The second part is devoted to the study of temperature-dependent elastic scattering of neutrons for heavy isotopes near to the thermal zone. A numerical computation of the Doppler convolution of the elastic scattering kernel based on the gas model is presented, for a general energy dependent cross section and scattering law in the center of mass system. The range of integration has been optimized employing a numerical cutoff, allowing a faster numerical evaluation of the convolution integral. Legendre moments of the transfer kernel are subsequently obtained by direct quadrature and a numerical analysis of the convergence is presented. In the third part we focus our attention to remote sensing applications of radiative transfer employed to investigate the Earth's cryosphere. The photon transport equation is applied to simulate reflectivity of glaciers varying the age of the layer of snow or ice, its thickness, the presence or not other underlying layers, the degree of dust included in the snow, creating a framework able to decipher spectral signals collected by orbiting detectors.
Resumo:
In questo elaborato si analizza l'Effetto Doppler e le sue applicazioni in astronomia.
Resumo:
Descrizione dal punto di vista fisico e astronomico dell'effetto Doppler con particolare attenzione all'utilizzo astrofisico
Resumo:
There is a demand for technologies able to assess the perfusion of surgical flaps quantitatively and reliably to avoid ischemic complications. The aim of this study is to test a new high-speed high-definition laser Doppler imaging (LDI) system (FluxEXPLORER, Microvascular Imaging, Lausanne, Switzerland) in terms of preoperative mapping of the vascular supply (perforator vessels) and postoperative flow monitoring. The FluxEXPLORER performs perfusion mapping of an area 9 x 9 cm with a resolution of 256 x 256 pixels within 6 s in high-definition imaging mode. The sensitivity and predictability to localize perforators is expressed by the coincidence of preoperatively assessed LDI high flow spots with intraoperatively verified perforators in nine patients. 18 free flaps are monitored before, during, and after total ischemia. 63% of all verified perforators correspond to a high flow spot, and 38% of all high flow spots correspond to a verified perforator (positive predictive value). All perfused flaps reveal a value of above 221 perfusion units (PUs), and all values obtained in the ischemic flaps are beneath 187 PU. In summary, we conclude that the present LDI system can serve as a reliable, fast, and easy-to-handle tool to detect ischemia in free flaps, whereas perforator vessels cannot be detected appropriately.
Resumo:
Systolic right ventricular (RV) function is an important predictor in the course of various congenital and acquired heart diseases. Its practical determination by echocardiography remains challenging. We compared routine assessment of lateral tricuspid annular systolic motion velocity (TV(lat), cm/s) using pulsed-wave tissue Doppler imaging from the apical 4-chamber view with cardiac magnetic resonance (CMR) as reference method.
Resumo:
The aim of this study was to analyse the cerebral venous outflow in relation to the arterial inflow during a Valsalva manoeuvre (VM). In 19 healthy volunteers (mean age 24.1 +/- 2.6 years), the middle cerebral artery (MCA) and the straight sinus (SRS) were insonated by transcranial Doppler sonography. Simultaneously the arterial blood pressure was recorded using a photoplethysmographic method. Two VM of 10 s length were performed per participant. Tracings of the variables were then transformed to equidistantly re-sampled data. Phases of the VM were analysed regarding the increase of the flow velocities and the latency to the peak. The typical four phases of the VM were also found in the SRS signal. The relative flow velocity (FV) increase was significantly higher in the SRS than in the MCA for all phases, particularly that of phase IV (p < 0.01). Comparison of the time latency of the VM phases of the MCA and SRS only showed a significant difference for phase I (p < 0.01). In particular, there was no significant difference for phase IV (15.8 +/- 0.29 vs. 16.0 +/- 0.28 s). Alterations in venous outflow in phase I are best explained by a cross-sectional change of the lumen of the SRS, while phases II and III are compatible with a Starling resistor. However, the significantly lager venous than the arterial overshoot in phase IV may be explained by the active regulation of the venous tone.
Resumo:
Transcatheter aortic valve implantation (TAVI) is an alternative to surgery for high-risk patients with severe aortic valve stenosis. Periprocedural stroke is reported at an incidence up to 10%. Magnetic resonance imaging studies have identified new onset of clinically silent ischaemic cerebral lesions more frequently (68-84%). So far, few data are available about cerebral embolism during TAVI. The aim of this study was to determine the frequency of high-intensity transient signals (HITS) and to explore differences in the HITS pattern between transfemoral and transapical access and between self-expanding (SE) and balloon-expandable (BE) deployment technique.
Resumo:
Rhythm analysis of the fetal heart is hampered by the inability to routinely obtain electrocardiographic recordings of the fetus. Doppler studies of fetal cardiac tissue movements, assessing cardiac movements both qualitatively and quantitatively, have recently been described. We used a conventional high-resolution ultrasound system to obtain rhythm data from pulsed-wave tissue Doppler signals of the fetal heart in normal cardiac rhythm and in a variety of fetal cardiac arrhythmias.
Resumo:
the aim of this study was to investigate specific activation patterns and potential gender differences during mental rotation and to investigate whether functional magnetic resonance imaging (fMRI) and functional transcranial Doppler sonography (fTCD) lateralize hemispheric dominance concordantly.
Resumo:
Early detection is a major goal in the management of malignant melanoma. Besides clinical assessment many noninvasive technologies such as dermoscopy, digital dermoscopy and in vivo laser scanner microscopy are used as additional methods. Herein we tested a system to assess lesional perfusion as a tool for early melanoma detection.
Resumo:
Background The evaluation of the hepatic parenchyma in patients with chronic liver disease is important to assess the extension, localization and relationship with adjacent anatomical structures of possible lesions. This is usually performed with conventional abdominal ultrasound, CT-scan or magnetic resonance imaging. In this context, the feasibility and the safety of intravascular ultrasound in the liver have not been assessed yet. Methods We tested the safety and performance of an intracardiac echography (ICE) catheter applied by a transjugular approach into the hepatic veins in patients with chronic liver disease undergoing hepatic hemodynamic measurements. Results Five patients were enrolled in this pilot study. The insertion of the ICE catheter was possible into the right and middle, but not into the left hepatic vein. The position of the ICE was followed using fluoroscopy and external conventional ultrasound. Accurate imaging of focal hepatic parenchymal lesions, Doppler ultrasound of surrounding blood vessels and assessment of liver surface and ascites were achieved without complications. Conclusions This study demonstrated that a diagnostic approach using an ICE device inserted in the hepatic veins is feasible, safe and well tolerated. However, it remains for the moment only an experimental investigative tool. Whether ICE adds further information regarding parenchymal lesions and associated vascular alterations as compared to other techniques, needs additional investigation.