978 resultados para Digital systems
Resumo:
The multidimensional process of physical, psychological, and social change produced by population ageing affects not only the quality of life of elderly people but also of our societies. Some dimensions of population ageing grow and expand over time (e.g. knowledge of the world events, or experience in particular situations), while others decline (e.g. reaction time, physical and psychological strength, or other functional abilities like reduced speed and tiredness). Information and Communication Technologies (ICTs) can help elderly to overcome possible limitations due to ageing. As a particular case, biometrics can allow the development of new algorithms for early detection of cognitive impairments, by processing continuous speech, handwriting or other challenged abilities. Among all possibilities, digital applications (Apps) for mobile phones or tablets can allow the dissemination of such tools. In this article, after presenting and discussing the process of population ageing and its social implications, we explore how ICTs through different Apps can lead to new solutions for facing this major demographic challenge.
Resumo:
NlmCategory="UNASSIGNED">A version of cascaded systems analysis was developed specifically with the aim of studying quantum noise propagation in x-ray detectors. Signal and quantum noise propagation was then modelled in four types of x-ray detectors used for digital mammography: four flat panel systems, one computed radiography and one slot-scan silicon wafer based photon counting device. As required inputs to the model, the two dimensional (2D) modulation transfer function (MTF), noise power spectra (NPS) and detective quantum efficiency (DQE) were measured for six mammography systems that utilized these different detectors. A new method to reconstruct anisotropic 2D presampling MTF matrices from 1D radial MTFs measured along different angular directions across the detector is described; an image of a sharp, circular disc was used for this purpose. The effective pixel fill factor for the FP systems was determined from the axial 1D presampling MTFs measured with a square sharp edge along the two orthogonal directions of the pixel lattice. Expectation MTFs were then calculated by averaging the radial MTFs over all possible phases and the 2D EMTF formed with the same reconstruction technique used for the 2D presampling MTF. The quantum NPS was then established by noise decomposition from homogenous images acquired as a function of detector air kerma. This was further decomposed into the correlated and uncorrelated quantum components by fitting the radially averaged quantum NPS with the radially averaged EMTF(2). This whole procedure allowed a detailed analysis of the influence of aliasing, signal and noise decorrelation, x-ray capture efficiency and global secondary gain on NPS and detector DQE. The influence of noise statistics, pixel fill factor and additional electronic and fixed pattern noises on the DQE was also studied. The 2D cascaded model and decompositions performed on the acquired images also enlightened the observed quantum NPS and DQE anisotropy.
Resumo:
Objective To develop procedures to ensure consistency of printing quality of digital images, by means of hardcopy quantitative analysis based on a standard image. Materials and Methods Characteristics of mammography DI-ML and general purpose DI-HL films were studied through the QC-Test utilizing different processing techniques in a FujiFilm®-DryPix4000 printer. A software was developed for sensitometric evaluation, generating a digital image including a gray scale and a bar pattern to evaluate contrast and spatial resolution. Results Mammography films showed maximum optical density of 4.11 and general purpose films, 3.22. The digital image was developed with a 33-step wedge scale and a high-contrast bar pattern (1 to 30 lp/cm) for spatial resolution evaluation. Conclusion Mammographic films presented higher values for maximum optical density and contrast resolution as compared with general purpose films. The utilized digital processing technique could only change the image pixels matrix values and did not affect the printing standard. The proposed digital image standard allows greater control of the relationship between pixels values and optical density obtained in the analysis of films quality and printing systems.
Resumo:
Abstract Objective: Derive filtered tungsten X-ray spectra used in digital mammography systems by means of Monte Carlo simulations. Materials and Methods: Filtered spectra for rhodium filter were obtained for tube potentials between 26 and 32 kV. The half-value layer (HVL) of simulated filtered spectra were compared with those obtained experimentally with a solid state detector Unfors model 8202031-H Xi R/F & MAM Detector Platinum and 8201023-C Xi Base unit Platinum Plus w mAs in a Hologic Selenia Dimensions system using a direct radiography mode. Results: Calculated HVL values showed good agreement as compared with those obtained experimentally. The greatest relative difference between the Monte Carlo calculated HVL values and experimental HVL values was 4%. Conclusion: The results show that the filtered tungsten anode X-ray spectra and the EGSnrc Monte Carlo code can be used for mean glandular dose determination in mammography.
Resumo:
In order to develop applications for z;isual interpretation of medical images, the early detection and evaluation of microcalcifications in digital mammograms is verg important since their presence is oftenassociated with a high incidence of breast cancers. Accurate classification into benign and malignant groups would help improve diagnostic sensitivity as well as reduce the number of unnecessa y biopsies. The challenge here is the selection of the useful features to distinguish benign from malignant micro calcifications. Our purpose in this work is to analyse a microcalcification evaluation method based on a set of shapebased features extracted from the digitised mammography. The segmentation of the microcalcificationsis performed using a fixed-tolerance region growing method to extract boundaries of calcifications with manually selected seed pixels. Taking into account that shapes and sizes of clustered microcalcificationshave been associated with a high risk of carcinoma based on digerent subjective measures, such as whether or not the calcifications are irregular, linear, vermiform, branched, rounded or ring like, our efforts were addressed to obtain a feature set related to the shape. The identification of the pammeters concerning the malignant character of the microcalcifications was performed on a set of 146 mammograms with their real diagnosis known in advance from biopsies. This allowed identifying the following shape-based parameters as the relevant ones: Number of clusters, Number of holes, Area, Feret elongation, Roughness, and Elongation. Further experiments on a set of 70 new mammogmms showed that the performance of the classification scheme is close to the mean performance of three expert radiologists, which allows to consider the proposed method for assisting the diagnosis and encourages to continue the investigation in the senseof adding new features not only related to the shape
Resumo:
Peer-to-Peer (P2P) technology has revolutionized file exchange activities besides enhancing processing power distribution. As such, this technology which is nowadays made freely available to all internet users also imposes a threat as it enables the illegal distribution of copyrighted digital work. P2P technology continuously evolves in a greater pace than copyright legislation, leading to compatibility gaps between the applicability of copyright law and the illicit file sharing and downloading. Such issues give high incentives to consumers to practise piracy using P2P systems with a low perception of risk towards prosecution, leading to substantial losses for copyright owners. This study focuses on developing insights for content owners on consumer behaviour towards piracy in Finland, where quantitative analyses are assessed using a data set based on a survey conducted by the Helsinki Institute for IT. The research approach investigates the significance of three fundamental areas in relation to evaluate consumer behaviour as: environmental-related factors, innovation-related factors and consumer-related. each of these are integrates concepts derived in previous theoretical models such as the technology acceptance model, theory of reasoned action, theory of planned behaviour, the issue-risk-judgement model and the Hunt & Vitell’s model.
Resumo:
We adapt the Shout and Act algorithm to Digital Objects Preservation where agents explore file systems looking for digital objects to be preserved (victims). When they find something they “shout” so that agent mates can hear it. The louder the shout, the urgent or most important the finding is. Louder shouts can also refer to closeness. We perform several experiments to show that this system works very scalably, showing that heterogeneous teams of agents outperform homogeneous ones over a wide range of tasks complexity. The target at-risk documents are MS Office documents (including an RTF file) with Excel content or in Excel format. Thus, an interesting conclusion from the experiments is that fewer heterogeneous (varying skills) agents can equal the performance of many homogeneous (combined super-skilled) agents, implying significant performance increases with lower overall cost growth. Our results impact the design of Digital Objects Preservation teams: a properly designed combination of heterogeneous teams is cheaper and more scalable when confronted with uncertain maps of digital objects that need to be preserved. A cost pyramid is proposed for engineers to use for modeling the most effective agent combinations
Resumo:
The development of new methodologies and tools that enable to determine the water content in soil is of fundamental importance to the practice of irrigation. The objective of this study was to evaluate soil matric potential using mercury tensiometer and puncture digital tensiometer, and to compare the gravimetric soil moisture values obtained by tensiometric system with gravimetric soil moisture obtained by neutron attenuation technique. Four experimental plots were maintained with different soil moisture by irrigation. Three repetitions of each type of tensiometer were installed at 0.20 m depth. Based on the soil matric potential and the soil water retention curve, the corresponding gravimetric soil moisture was determined. The data was then compared to those obtained by neutron attenuation technique. The results showed that both tensiometric methods showed no difference under soil matric potential higher than -40 kPa. However, under drier soil, when the water was replaced by irrigation, the soil matric potential of the puncture digital tensiometer was less than those of the mercury tensiometer.
Resumo:
Presentation at Open Repositories 2014, Helsinki, Finland, June 9-13, 2014
Resumo:
Panel at Open Repositories 2014, Helsinki, Finland, June 9-13, 2014
Resumo:
Presentation at Open Repositories 2014, Helsinki, Finland, June 9-13, 2014
Resumo:
Workshop at Open Repositories 2014, Helsinki, Finland, June 9-13, 2014
Resumo:
Poster at Open Repositories 2014, Helsinki, Finland, June 9-13, 2014
Resumo:
Presentation at Open Repositories 2014, Helsinki, Finland, June 9-13, 2014
Resumo:
Presentation at Open Repositories 2014, Helsinki, Finland, June 9-13, 2014