694 resultados para Craniocervical Flexion
Resumo:
Comme en 2009, le groupe des jeunes pharma- ciens suisses (swissYPG) organise cette année un nouveau symposium de formation et de ré- flexion à destination des jeunes pharmaciennes et pharmaciens suisses. Ce dernier aura lieu à Interlaken le 30 novembre 2011, dans le cadre du 1er congrès suisse des pharmaciens.
Resumo:
Purpose of the study: Reconstruction of the anterior cruciate ligament (ACL) controls laxity but does not enable restoration of strictly normal 3D kinematics. The purpose of this study was to compare the kinematics of the pathological knee with that of the healthy knee after ACL plasty. This study applied a new ambulatory system using miniature captors. Material and method: Five patients with an isolated injury of the ACL participated in this study. The patients were assessed after injury (T1), at five months (T2), and at 14 months (T3) after surgery. The assessment included laxity (KT-1000), the IKDC score and the Lysholm score. The 3D angles of the knees were measured when walking 30 m on flat ground using a system composed of to small inertia units (3D accelerometer and 3D gyroscope) and a portable recorder. Functional settings were optimised and validating to ensure easy precise measurement of the 3D angles. Symmetry of the two knees was quantified using a symmetry index (SI) (difference in amplitude normalised in relation to mean amplitude) and the correlation coefficient CC. Results: Clinical indicators improved during the follow-up (IKDC T1: 3C, 2C; T2: 5B; T3: 2A, 3B; subjective IKD: 53-95; Lysholm 67-96). Mean laxity improved from 8.6m to 2.5 mm. The gait analysis showed increased symmetry in terms of amplitude for flexion-extension (SI: −17% at T1, −1% at T2, 1% at T3), and an increase in symmetry in terms of the rotation signature (CC: 0.16 at T1, 0.99 at T2, 0.99 at T3). There was no trend to varus-valgus. Discussion: This study demonstrates the clinical application of the new ambulatory system for measuring 3D angles of the knee joint. Joint symmetry increased after ACL plasty but still showed some perturbation at 14 months. The results observed here are in agreement with the literature. Other patients and other types of gait are being analysed. Conclusion: This portable system allows gait analysis outside the laboratory, before and after ACL injury. It is very useful for follow-up after surgery.
Resumo:
INTRODUCTION: Spectral frequencies of the surface electromyogram (sEMG) increase with contraction force, but debate still exists on whether this increase is affected by various methodological and anatomical factors. This study aimed to investigate the influence of inter-electrode distance (IED) and contraction modality (step-wise vs. ramp) on the changes in spectral frequencies with increasing contraction strength for the vastus lateralis (VL) and vastus medialis (VM) muscles. METHODS: Twenty healthy male volunteers were assessed for isometric sEMG activity of the VM and VL, with the knee at 90° flexion. Subjects performed isometric ramp contractions in knee extension (6-s duration) with the force gradually increasing from 0 to 80 % MVC. Also, subjects performed 4-s step-wise isometric contractions at 10, 20, 30, 40, 50, 60, 70, and 80 % MVC. Interference sEMG signals were recorded simultaneously at different IEDs: 10, 20, 30, and 50 mm. The mean (F mean) and median (F median) frequencies and root mean square (RMS) of sEMG signals were calculated. RESULTS: For all IEDs, contraction modalities, and muscles tested, spectral frequencies increased significantly with increasing level of force up to 50-60 % MVC force. Spectral indexes increased systematically as IED was decreased. The sensitivity of spectral frequencies to changes in contraction force was independent of IED. The behaviour of spectral indexes with increasing contraction force was similar for step-wise and ramp contractions. CONCLUSIONS: In the VL and VM muscles, it is highly unlikely that a particular inter-electrode distance or contraction modality could have prevented the observation of the full extent of the increase in spectral frequencies with increasing force level.
Resumo:
RESUME : Bien que les propriétés physiques de la structure de l'ADN aient été intensivement étudiées pendant plus de 50 ans il y a encore beaucoup de questions importantes qui attendent des réponses. Par exemple, qu'arrive-t-il à la structure de la double hélice d'ADN nue (sans protéines liées) lorsqu'elle est fortement courbée, de la même manière que dans les nucléosomes? Cet ADN nu est-il facilement plié (il reste dans le régime élastique) ou réduit-il la contrainte de flexion en formant des sites hyperflexibles «kinks» (il sort du régime élastique en cassant l'empilement des paires de bases à certains endroits) ? La microscopie électronique peut fournir une réponse à cette question par visualisation directe des minicercles d'ADN de la longueur d'un tour de nucléosome (environ 90 paires de bases). Pour que la réponse soit scientifiquement valide, on doit observer les molécules d'ADN lorsqu'elles sont en suspension dans la solution d'intérêt et sans que des colorations, produits chimiques ou fixatifs n'aient été ajoutés, étant donné que ceux-ci peuvent changer les propriétés de l'ADN. La technique de la cryo-microscopie électronique (cryo-EM) développée par le groupe de Jacques Dubochet au début des années 80, permet la visualisation directe des molécules d'ADN suspendues dans des couche minces vitrifiées de solutions aqueuses. Toutefois, le faible contraste qui caractérise la cryo-EM combinée avec la très petite taille des minicercles d'ADN rendent nécessaire l'optimisation de plusieurs étapes, aussi bien dans la préparation des échantillons que dans le processus d'acquisition d'images afin d'obtenir deux clichés stéréo qui permettent la reconstruction 3-D des minicercles d'ADN. Dans la première partie de ma thèse, je décris l'optimisation de certains paramètres pour la cryoEM et des processus d'acquisition d'image utilisant comme objets de test des plasmides et d'autres molécules d'ADN. Dans la deuxième partie, je .décris comment j'ai construit les minicercles d'ADN de 94 bp et comment j'ai introduit des modifications structurelles comme des coupures ou des lacunes. Dans la troisième partie, je décris l'analyse des reconstructions des rninicercles d'ADN. Cette analyse, appuyée par des tests biochimiques, indique fortement que des molécules d'ADN sont capables de former de petites molécules circulaires de 94 bp sans dépasser les limites d'élasticité, indiquant que les minicercles adoptent une forme circulaire régulière où la flexion est redistribuée le long la molécule. ABSTRACT : Although physical properties of DNA structure have been intensively studied for over 50 years there are still many important questions that need to be answered. For example, what happens to protein-free double-stranded DNA when it is strongly bent, as in DNA forming nucleosomes? Is such protein-free DNA smoothly bent (i.e. it remains within elastic limits of DNA rigidity) or does it release its bending stress by forming sharp kinks (i.e. it exits the elastic regime and breaks the stacking between neighbouring base-pairs in localized regions)? Electron microscopy can provide an answer to this question by directly visualizing DNA minicircles that have the size of nucleosome gyres (ca 90 bp). For the answer to be scientifically valid, one needs to observe DNA molecules while they are still suspended in the solution of interest and no staining chemicals or fixatives have been added since these can change the properties of the DNA. CryoEM techniques developed by Jacques Dubochet's group beginning in the 1980's permit direct visualization of DNA molecules suspended in cryo-vitrified layers of aqueous solutions. However, a relatively weak contrast of cryo-EM preparations combined with the very small size of the DNA minicircles made it necessary to optimize many of the steps and parameters of the cryo-EM specimen preparation and image acquisition processes in order to obtain stereo-pairs of images that permit the 3-D reconstruction of the observed DNA minicircles. In the first part of my thesis I describe the optimization of the cryo-EM preparation and the image acquisition processes using plasmid size DNA molecules as a test object. In the second part, I describe how I formed the 94 by DNA minicircles and how I introduced structural modifications like nicks or gaps. In the third part, I describe the cryo-EM analysis of the constructed DNA minicircles. That analysis, supported by biochemical tests, strongly indicates that DNA minicircles as small as 94 by remain within the elastic limits of DNA structure, i.e. the minicircles adopt a regular circular shape where bending is redistributed along the molecules.
Resumo:
Introduction: Ankle arthropathy is associated with a decreased motion of the ankle-hindfoot during ambulation. Ankle arthrodesis was shown to result in degeneration of the neighbour joints of the foot. Inversely, total ankle arthroplasty conceptually preserves the adjacent joints because of the residual mobility of the ankle but this has not been demonstrated yet in vivo. It has also been reported that degenerative ankle diseases, and even arthrodesis, do not result in alteration of the knee and hip joints. We present the preliminary results of a new approach of this problem based on ambulatory gait analysis. Patients and Methods: Motion analysis of the lower limbs was performed using a Physilog® (BioAGM, CH) system consisting of three-dimensional (3D) accelerometer and gyroscope, coupled to a magnetic system (Liberty©, Polhemus, USA). Both systems have been validated. Three groups of two patients were included into this pilot study and compared to healthy subjects (controls) during level walking: patients with ankle osteoarthritis (group 1), patients treated by ankle arthrodesis (group 2), patients treated by total ankle prosthesis (group 3). Results: Motion patterns of all analyzed joints over more than 20 gait cycles in each subject were highly repeatable. Motion amplitude of the ankle-hindfoot in control patients was similar to recently reported results. Ankle arthrodesis limited the motion of the ankle-hindfoot in the sagittal and horizontal planes. The prosthetic ankle allowed a more physiologic movement in the sagittal plane only. Ankle arthritis and its treatments did not influence the range of motion of the knee and hip joint during stance phase, excepted for a slight decrease of the hip flexion in groups 1 and 2. Conclusion: The reliability of the system was shown by the repeatability of the consecutive measurements. The results of this preliminary study were similar to those obtained through laboratory gait analysis. However, our system has the advantage to allow ambulatory analysis of 3D kinematics of the lower limbs outside of a gait laboratory and in real life conditions. To our knowledge this is a new concept in the analysis of ankle arthropathy and its treatments. Therefore, there is a potential to address specific questions like the difficult comparison of the benefits of ankle arthroplasty versus arthrodesis. The encouraging results of this pilot study offer the perspective to analyze the consequences of ankle arthropathy and its treatments on the biomechanics of the lower limbs ambulatory, in vivo and in daily life conditions.
Resumo:
OBJECTIVE: assess the functional, subjective and radiological results obtained in patients treated with variable-angle locking plate for unstable distal radius fracture and compare these results with current studies. PATIENTS AND METHOD: From October of 2008 to July of 2011, 20 patients were included who had undergone intervention using the volar approach to the Flexor Carpi Radialis. The average follow up was 18 months. Both clinical and radiological results were analyzed. The Mayo Wrist Score and DASH questioner were used. RESULTS: The average age was 50 years; 50% men and 50% women. The consolidation of the fracture was verified in all cases. An average volar angle was obtained of 5º, radial inclination of 19º, radial height of 10.5 mm, and ulnar variance of -1 mm. The clinical assessment revealed an average dorsal flexion of 75º, palm flexion of 70º, supination of 75º and pronation of 73 º. The results for the DASH questionnaire showed an average of 17.8 and 82.7 for the Mayo Wrist Score. CONCLUSIONS: Our experience has provided some good results, both in functional and subjective as well as radio logical terms, similar to those found in studies with implants from the same generation.
Resumo:
A new ambulatory technique for qualitative and quantitative movement analysis of the humerus is presented. 3D gyroscopes attached on the humerus were used to recognize the movement of the arm and to classify it as flexion, abduction and internal/external rotations. The method was first validated in a laboratory setting and then tested on 31 healthy volunteer subjects while carrying the ambulatory system during 8 h of their daily life. For each recording, the periods of sitting, standing and walking during daily activity were detected using an inertial sensor attached on the chest. During each period of daily activity the type of arm movement (flexion, abduction, internal/external rotation) its velocity and frequency (number of movement/hour) were estimated. The results showed that during the whole daily activity and for each activity (i.e. walking, sitting and walking) the frequency of internal/external rotation was significantly higher while the frequency of abduction was the lowest (P < 0.009). In spite of higher number of flexion, abduction and internal/external rotation in the dominant arm, we have not observed in our population a significant difference with the non-dominant arm, implying that in healthy subjects the arm dominance does not lie considerably on the number of movements. As expected, the frequency of the movement increased from sitting to standing and from standing to walking, while we provide a quantitative value of this change during daily activity. This study provides preliminary evidence that this system is a useful tool for objectively assessing upper-limb activity during daily activity. The results obtained with the healthy population could be used as control data to evaluate arm movement of patients with shoulder diseases during daily activity.
Resumo:
Measurement of three-dimensional (3D) knee joint angle outside a laboratory is of benefit in clinical examination and therapeutic treatment comparison. Although several motion capture devices exist, there is a need for an ambulatory system that could be used in routine practice. Up-to-date, inertial measurement units (IMUs) have proven to be suitable for unconstrained measurement of knee joint differential orientation. Nevertheless, this differential orientation should be converted into three reliable and clinically interpretable angles. Thus, the aim of this study was to propose a new calibration procedure adapted for the joint coordinate system (JCS), which required only IMUs data. The repeatability of the calibration procedure, as well as the errors in the measurement of 3D knee angle during gait in comparison to a reference system were assessed on eight healthy subjects. The new procedure relying on active and passive movements reported a high repeatability of the mean values (offset<1 degrees) and angular patterns (SD<0.3 degrees and CMC>0.9). In comparison to the reference system, this functional procedure showed high precision (SD<2 degrees and CC>0.75) and moderate accuracy (between 4.0 degrees and 8.1 degrees) for the three knee angle. The combination of the inertial-based system with the functional calibration procedure proposed here resulted in a promising tool for the measurement of 3D knee joint angle. Moreover, this method could be adapted to measure other complex joint, such as ankle or elbow.
Resumo:
Introduction.- Since the work of the "International Association for the Study of Pain" (IASP), complex regional pain syndrome type 1 (CRPS I) or algodystrophy includes motor disorders (tremor, dystony, myoclony) as diagnosis criterion. This can lead to confusion with some neurologic disorders which can wrongly be considered as CRPS I. The following observation illustrates this problem.Observation.- A 31-year-old man was hospitalised in a rehabilitation clinic in April 2007 with suspected CRPS I with persistent pain in the left leg. In 2005, the patient underwent ligament reconstruction at the right ankle. In May 2006, a recurrence of his ankle sprain was treated conservatively. The course of this pathology was unfavourable with an extension of the pain areas (leg and foot) as well as an appearance of abnormal motion. Toe motion in abduction was observed (especially T5) followed by a flexion cramp; an hypoesthesia in the sural nerve area, a scar allodynia and discrete vasomotor disorders. The scintigraphy was compatible with a stage 2 algodystrophy. Lower limb electromyography was normal; measurement of pseudo periodic activity of the motor unit at the foot level (abductor of the 5th toe, 4th interosseous). A "Painful legs and moving toes syndrome" was diagnosed which was treated with gabapentin and carbamazepine with a partial improvement.Discussion.- The "Painful legs and moving toes syndrome" is a rare pathology rehabilitation specialists should recognize. The origin is often peripheral nerve damage. The medullar interneuron activation (between the dorsal and ventral horn) is considered as the source of the efferent motor nerves which are responsible for the abnormal movements. This observation illustrates the need for a demanding approach before establishing the diagnosis of CRPS I and the respect of the 4th criterion of the ASP (exclusion of this syndrome when another pathology may explain pain and dysfunction).
Resumo:
BACKGROUND: Medialization of the cup with a respective increase in femoral offset has been proposed in THA to increase abductor moment arms. Insofar as there are potential disadvantages to cup medialization, it is important to ascertain whether the purported biomechanical benefits of cup medialization are large enough to warrant the downsides; to date, studies regarding this question have disagreed. QUESTIONS/PURPOSES: The purpose of this study was to quantify the effect of cup medialization with a compensatory increase in femoral offset compared with anatomic reconstruction for patients undergoing THA. We tested the hypothesis that there is a (linear) correlation between preoperative anatomic parameters and muscle moment arm increase caused by cup medialization. METHODS: Fifteen patients undergoing THA were selected, covering a typical range of preoperative femoral offsets. For each patient, a finite element model was built based on a preoperative CT scan. The model included the pelvis, femur, gluteus minimus, medius, and maximus. Two reconstructions were compared: (1) anatomic position of the acetabular center of rotation, and (2) cup medialization compensated by an increase in the femoral offset. Passive abduction-adduction and flexion-extension were simulated in the range of normal gait. Muscle moment arms were evaluated and correlated to preoperative femoral offset, acetabular offset, height of the greater trochanter (relative to femoral center of rotation), and femoral antetorsion angle. RESULTS: The increase of muscle moment arms caused by cup medialization varied among patients. Muscle moment arms increase by 10% to 85% of the amount of cup medialization for abduction-adduction and from -35% (decrease) to 50% for flexion-extension. The change in moment arm was inversely correlated (R(2) = 0.588, p = 0.001) to femoral antetorsion (anteversion), such that patients with less femoral antetorsion gained more in terms of hip muscle moments. No linear correlation was observed between changes in moment arm and other preoperative parameters in this series. CONCLUSIONS: The benefit of cup medialization is variable and depends on the individual anatomy. CLINICAL RELEVANCE: Cup medialization with compensatory increase of the femoral offset may be particularly effective in patients with less femoral antetorsion. However, cup medialization must be balanced against its tradeoffs, including the additional loss of medial acetabular bone stock, and eventual proprioceptive implications of the nonanatomic center of rotation and perhaps joint reaction forces. Clinical studies should better determine the relevance of small changes of moment arms on function and joint reaction forces.
Total knee arthroplasty - a clinical and numerical study of the micromovements of the tibial implant
Resumo:
Introduction The importance of the micromovements in the mechanism of aseptic loosening is clinically difficult to evaluate. To complete the analysis of a series of total knee arthroplasties (TKA), we used a tridimensional numerical model to study the micromovements of the tibial implant.Material and Methods Fifty one patients (with 57 cemented Porous Coated Anatomic TKAs) were reviewed (mean follow-up 4.5 year). Radiolucency at the tibial bone-cement interface was sought on the AP radiographs and divided in 7 areas. The distribution of the radiolucency was then correlated with the axis of the lower limb as measured on the orthoradiograms.The tridimensional numerical model is based on the finite element method. It allowed the measurement of the cemented prosthetic tibial implant's displacements and the microvements generated at bone-ciment interface. A total load (2000 Newton) was applied at first vertically and asymetrically on the tibial plateau, thereby simulating an axial deviation of the lower limbs. The vector's posterior inclination then permitted the addition of a tangential component to the axial load. This type of effort is generated by complex biomechanical phenomena such as knee flexion.Results 81 per cent of the 57 knees had a radiolucent line of at least 1 mm, at one or more of the tibial cement-epiphysis jonctional areas. The distribution of these lucent lines showed that they came out more frequently at the periphery of the implant. The lucent lines appeared most often under the unloaded margin of the tibial plateau, when axial deviation of lower limbs was present.Numerical simulations showed that asymetrical loading on the tibial plateau induced a subsidence of the loaded margin (0-100 microns) and lifting off at the opposite border (0-70 microns). The postero-anterior tangential component induced an anterior displacement of the tibial implant (160-220 microns), and horizontal micromovements with non homogenous distribution at the bone-ciment interface (28-54 microns).Discussion Comparison of clinical and numerical results showed a relation between the development of radiolucent lines and the unloading of the tibial implant's margin. The deleterious effect of lower limbs' axial deviation is thereby proven. The irregular distribution of lucent lines under the tibial plateau was similar of the micromovements' repartition at the bone-cement interface when tangential forces were present. A causative relation between the two phenomenaes could not however be established.Numerical simulation is a truly useful method of study; it permits to calculate micromovements which are relative, non homogenous and of very low amplitude. However, comparative clinical studies remain as essential to ensure the credibility of results.
Resumo:
Introduction: Enchondromas are among the most current benign bone tumours. Malignant degeneration is extremely rare (<1%) and generally presents as a low grade chondrosarcoma. For localized grade 1 lesions, the treatment of choice is curettage. Wide excision and reconstruction is generally not necessary, unless locally advanced or more aggressive behaviour is suspected at presentation. Case report: A healthy 72 yo male presented with pain and recurrent knee joint effusion. X-rays show a classical central distal metaphyseal enchondroma of the femur associated with subtle osteolysis of the lateral condyle. MRI confirms the presence of a locally aggressive chondromatous lesion based in a classical enchondroma. Core needle biopsy revealed a grade 1 chondrosarcoma, which was in contrast to the radiological aggressiveness of the lesion. Total body CT-scan did not reveal metastatic disease. A wide resection was planned, as a high-grade lesion and joint contamination was suspected. We performed an extra-articular knee resection and reconstruction with a hinged modular total knee megaprosthesis. The definitive histology was grade 1 chondrosarcoma, the surgical margins were wide. The evolution was favourable and the patient was able to perform all his activities of daily living independently without pain at 6 weeks postop. Knee flexion reached 90°. The oncologic screening at 18 months did not show local or distant recurrence. Conclusion: Joints near a benign tumour that suddenly become symptomatic or present an effusion might indicate a malignant transformation. Wide resection and prosthetic reconstruction remains an effective treatment option even in low grade cartilaginous lesions if (1) the adjacent joint is contaminated, or (2) joint-sparing surgery would result in a severe functional impairment of the limb.
Resumo:
Collection : Archives de la linguistique française ; 281
Resumo:
The treatment of craniocervical instability caused by diverse conditions remains challenging. Different techniques have been described to stabilize the craniocervical junction. The authors present 2 cases in which tumoral destruction of the C-1 lateral mass caused craniocervical instability. A one-stage occipitoaxial spinal interarticular stabilization (OASIS) technique with titanium cages and posterior occipitocervical instrumentation was used to reconstruct the C-1 lateral mass and stabilize the craniocervical junction. The ipsilateral vertebral artery was preserved. The OASIS technique offers single-stage tumor resection, C-1 lateral mass reconstruction, and stabilization with a loadsharing construct. It could be an option in the treatment of select cases of C-1 lateral mass failure.
Resumo:
A new method of measuring joint angle using a combination of accelerometers and gyroscopes is presented. The method proposes a minimal sensor configuration with one sensor module mounted on each segment. The model is based on estimating the acceleration of the joint center of rotation by placing a pair of virtual sensors on the adjacent segments at the center of rotation. In the proposed technique, joint angles are found without the need for integration, so absolute angles can be obtained which are free from any source of drift. The model considers anatomical aspects and is personalized for each subject prior to each measurement. The method was validated by measuring knee flexion-extension angles of eight subjects, walking at three different speeds, and comparing the results with a reference motion measurement system. The results are very close to those of the reference system presenting very small errors (rms = 1.3, mean = 0.2, SD = 1.1 deg) and excellent correlation coefficients (0.997). The algorithm is able to provide joint angles in real-time, and ready for use in gait analysis. Technically, the system is portable, easily mountable, and can be used for long term monitoring without hindrance to natural activities.