Fracturas inestables de radio distal. Nuestra experiencia en osteosíntesis con placa volar de ángulo variable


Autoria(s): Rojas, Facundo; Rodríguez León, Alfredo; Gormaz Talavera, Irene; Aragón Outon, Adela; Álvarez Blanco, Miguel; Villanueva Pareja, Francisco
Data(s)

29/04/2014

29/04/2014

2012

Resumo

OBJECTIVE: assess the functional, subjective and radiological results obtained in patients treated with variable-angle locking plate for unstable distal radius fracture and compare these results with current studies. PATIENTS AND METHOD: From October of 2008 to July of 2011, 20 patients were included who had undergone intervention using the volar approach to the Flexor Carpi Radialis. The average follow up was 18 months. Both clinical and radiological results were analyzed. The Mayo Wrist Score and DASH questioner were used. RESULTS: The average age was 50 years; 50% men and 50% women. The consolidation of the fracture was verified in all cases. An average volar angle was obtained of 5º, radial inclination of 19º, radial height of 10.5 mm, and ulnar variance of -1 mm. The clinical assessment revealed an average dorsal flexion of 75º, palm flexion of 70º, supination of 75º and pronation of 73 º. The results for the DASH questionnaire showed an average of 17.8 and 82.7 for the Mayo Wrist Score. CONCLUSIONS: Our experience has provided some good results, both in functional and subjective as well as radio logical terms, similar to those found in studies with implants from the same generation.

Identificador

Rojas F, Rodríguez León A, Gormaz Talavera I, Aragón Outon A, Álvarez Blanco M, Villanueva Pareja F. Fracturas inestables de radio distal. Nuestra experiencia en osteosíntesis con placa volar de ángulo variable. Rev S And Traum y Ort. 2012; 29(2/2):9-15.

0212-0771 (Print)

1578-9756 (Online)

http://hdl.handle.net/10668/1598

Idioma(s)

es

Publicador

Sociedad Andaluza de Traumatología y Ortopedia (SATO)

Relação

Revista de la Sociedad Andaluza de Traumatología y Ortopedia

http://www.portalsato.es/publicaciones-sato/revista-sato/2011-2015/revista-2012-2%C2%BA-semestre.html

Direitos

Acceso abierto

Palavras-Chave #Unstable fractures #Distal radius #Volar plate osteosynthesis #Variable angle plate #Fracturas inestables #Radio distal #Osteosíntesis placa volar #Ángulo variable placa #Medical Subject Headings::Check Tags::Female #Medical Subject Headings::Check Tags::Male #Medical Subject Headings::Check Tags::Female #Medical Subject Headings::Analytical, Diagnostic and Therapeutic Techniques and Equipment::Investigative Techniques::Epidemiologic Methods::Data Collection::Questionnaires
Tipo

info:eu-repo/semantics/article

info:eu-repo/semantics/published

Artículo