993 resultados para Contact CR-Warped Product


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Contact lenses are a common method for the correction of refractive errors of the eye. While there have been significant advancements in contact lens designs and materials over the past few decades, the lenses still represent a foreign object in the ocular environment and may lead to physiological as well as mechanical effects on the eye. When contact lenses are placed in the eye, the ocular anatomical structures behind and in front of the lenses are directly affected. This thesis presents a series of experiments that investigate the mechanical and physiological effects of the short-term use of contact lenses on anterior and posterior corneal topography, corneal thickness, the eyelids, tarsal conjunctiva and tear film surface quality. The experimental paradigm used in these studies was a repeated measures, cross-over study design where subjects wore various types of contact lenses on different days and the lenses were varied in one or more key parameters (e.g. material or design). Both, old and newer lens materials were investigated, soft and rigid lenses were used, high and low oxygen permeability materials were tested, toric and spherical lens designs were examined, high and low powers and small and large diameter lenses were used in the studies. To establish the natural variability in the ocular measurements used in the studies, each experiment also contained at least one “baseline” day where an identical measurement protocol was followed, with no contact lenses worn. In this way, changes associated with contact lens wear were considered in relation to those changes that occurred naturally during the 8 hour period of the experiment. In the first study, the regional distribution and magnitude of change in corneal thickness and topography was investigated in the anterior and posterior cornea after short-term use of soft contact lenses in 12 young adults using the Pentacam. Four different types of contact lenses (Silicone hydrogel/ Spherical/–3D, Silicone Hydrogel/Spherical/–7D, Silicone Hydrogel/Toric/–3D and HEMA/Toric/–3D) of different materials, designs and powers were worn for 8 hours each, on 4 different days. The natural diurnal changes in corneal thickness and curvature were measured on two separate days before any contact lens wear. Significant diurnal changes in corneal thickness and curvature within the duration of the study were observed and these were taken into consideration for calculating the contact lens induced corneal changes. Corneal thickness changed significantly with lens wear and the greatest corneal swelling was seen with the hydrogel (HEMA) toric lens with a noticeable regional swelling of the cornea beneath the stabilization zones, the thickest regions of the lenses. The anterior corneal surface generally showed a slight flattening with lens wear. All contact lenses resulted in central posterior corneal steepening, which correlated with the relative degree of corneal swelling. The corneal swelling induced by the silicone hydrogel contact lenses was typically less than the natural diurnal thinning of the cornea over this same period (i.e. net thinning). This highlights why it is important to consider the natural diurnal variations in corneal thickness observed from morning to afternoon to accurately interpret contact lens induced corneal swelling. In the second experiment, the relative influence of lenses of different rigidity (polymethyl methacrylate – PMMA, rigid gas permeable – RGP and silicone hydrogel – SiHy) and diameters (9.5, 10.5 and 14.0) on corneal thickness, topography, refractive power and wavefront error were investigated. Four different types of contact lenses (PMMA/9.5, RGP/9.5, RGP/10.5, SiHy/14.0), were worn by 14 young healthy adults for a period of 8 hours on 4 different days. There was a clear association between fluorescein fitting pattern characteristics (i.e. regions of minimum clearance in the fluorescein pattern) and the resulting corneal shape changes. PMMA lenses resulted in significant corneal swelling (more in the centre than periphery) along with anterior corneal steepening and posterior flattening. RGP lenses, on the other hand, caused less corneal swelling (more in the periphery than centre) along with opposite effects on corneal curvature, anterior corneal flattening and posterior steepening. RGP lenses also resulted in a clinically and statistically significant decrease in corneal refractive power (ranging from 0.99 to 0.01 D), large enough to affect vision and require adjustment in the lens power. Wavefront analysis also showed a significant increase in higher order aberrations after PMMA lens wear, which may partly explain previous reports of "spectacle blur" following PMMA lens wear. We further explored corneal curvature, thickness and refractive changes with back surface toric and spherical RGP lenses in a group of 6 subjects with toric corneas. The lenses were worn for 8 hours and measurements were taken before and after lens wear, as in previous experiments. Both lens types caused anterior corneal flattening and a decrease in corneal refractive power but the changes were greater with the spherical lens. The spherical lens also caused a significant decrease in WTR astigmatism (WRT astigmatism defined as major axis within 30 degrees of horizontal). Both the lenses caused slight posterior corneal steepening and corneal swelling, with a greater effect in the periphery compared to the central cornea. Eyelid position, lid-wiper and tarsal conjunctival staining were also measured in Experiment 2 after short-term use of the rigid and SiHy contact lenses. Digital photos of the external eyes were captured for lid position analysis. The lid-wiper region of the marginal conjunctiva was stained using fluorescein and lissamine green dyes and digital photos were graded by an independent masked observer. A grading scale was developed in order to describe the tarsal conjunctival staining. A significant decrease in the palpebral aperture height (blepharoptosis) was found after wearing of PMMA/9.5 and RGP/10.5 lenses. All three rigid contact lenses caused a significant increase in lid-wiper and tarsal staining after 8 hours of lens wear. There was also a significant diurnal increase in tarsal staining, even without contact lens wear. These findings highlight the need for better contact lens edge design to minimise the interactions between the lid and contact lens edge during blinking and more lubricious contact lens surfaces to reduce ocular surface micro-trauma due to friction and for. Tear film surface quality (TFSQ) was measured using a high-speed videokeratoscopy technique in Experiment 2. TFSQ was worse with all the lenses compared to baseline (PMMA/9.5, RGP/9.5, RGP/10.5, and SiHy/14) in the afternoon (after 8 hours) during normal and suppressed blinking conditions. The reduction in TFSQ was similar with all the contact lenses used, irrespective of their material and diameter. An unusual pattern of change in TFSQ in suppressed blinking conditions was also found. The TFSQ with contact lens was found to decrease until a certain time after which it improved to a value even better than the bare eye. This is likely to be due to the tear film drying completely over the surface of the contact lenses. The findings of this study also show that there is still a scope for improvement in contact lens materials in terms of better wettability and hydrophilicity in order to improve TFSQ and patient comfort. These experiments showed that a variety of changes can occur in the anterior eye as a result of the short-term use of a range of commonly used contact lens types. The greatest corneal changes occurred with lenses manufactured from older HEMA and PMMA lens materials, whereas modern SiHy and rigid gas permeable materials caused more subtle changes in corneal shape and thickness. All lenses caused signs of micro-trauma to the eyelid wiper and palpebral conjunctiva, although rigid lenses appeared to cause more significant changes. Tear film surface quality was also significantly reduced with all types of contact lenses. These short-term changes in the anterior eye are potential markers for further long term changes and the relative differences between lens types that we have identified provide an indication of areas of contact lens design and manufacture that warrant further development.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The character of James Bond for many people is intrinsically linked in their minds with particular brands – Aston Martin, Bollinger, Omega, Smirnoff vodka, and so on. This direct association between character and brand highlights the intrinsic role of product placement in the film industry, and in the James Bond films in particular. Selling James Bond: Product Placement in the James Bond Films provides a comprehensive overview of the history of product placement in the James Bond series – charting the progression of the practice and drawing direct correlations to significant cultural and historical events that impacted upon the number and types of products incorporated into the series. While primarily a financial arrangement, it is also important that the practice of product placement be examined and understood in relation to these cultural contexts, an area of research so far largely ignored by academic study. Through extensive content analysis of the official James Bond film series, as well as utilising directors’ commentary and industry reports, this book illustrates the strong impact specific cultural and historical events have had on the practice of product placement in the series. In doing so, it provides an exciting and in-depth “behind the scenes” look at the James Bond film series, and its complicated and sometimes contentious history of product placement. In the process, it charts the gradual emergence of product placement from the more traditional background shot to becoming so embedded in the actual film narrative that they have become simply yet another method for filmmakers to produce cultural meaning.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This series of research vignettes is aimed at sharing current and interesting findings from our team of international Entrepreneurship researchers. In this vignette, Dr Henri Burgers considers some of the factors that can make a difference in managing new product development.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The accuracy of measurement of mechanical properties of a material using instrumented nanoindentation at extremely small penetration depths heavily relies on the determination of the contact area of the indenter. Our experiments have demonstrated that the conventional area function could lead to a significant error when the contact depth was below 40. nm, due to the singularity in the first derivation of the function in this region and thus, the resultant unreasonable sharp peak on the function curve. In this paper, we proposed a new area function that was used to calculate the contact area for the indentations where the contact depths varied from 10 to 40. nm. The experimental results have shown that the new area function has produced better results than the conventional function. © 2011 Elsevier B.V.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: To measure tear film surface quality (TFSQ) using dynamic high-speed videokeratoscopy during short-term (8 hours) use of rigid and soft contact lenses. Methods: A group of fourteen subjects wore 3 different types of contact lenses on 3 different non-consecutive days (order randomized) in one eye only. Subjects were screened to exclude those with dry eye. The lenses included a PMMA hard, an RGP (Boston XO) and a soft silicone hydrogel lens. Three 30 second long high speed videokeratoscopy recordings were taken with contact lenses in-situ, in the morning and again after 8 hours of contact lens wear, both in normal and suppressed blinking conditions. Recordings were also made on a baseline day with no contact lens wear. Results: The presence of a contact lens in the eye had a significant effect on the mean TFSQ in both natural and suppressed blinking conditions (p=0.001 and p=0.01 respectively, repeated measures ANOVA). TFSQ was worse with all the lenses compared to no lens in the eye (in the afternoon during both normal and suppressed blinking conditions (all p<0.05). In natural blinking conditions, the mean TFSQ for the PMMA and RGP lenses was significantly worse than the baseline day (no lens) for both morning and afternoon measures (p<0.05). Conclusions: This study shows that both rigid and soft contact lenses adversely affect the TFSQ in both natural and suppressed blinking conditions. No significant differences were found between the lens types and materials. Keywords: Tear film surface quality, rigid contact lens, soft contact lens, dynamic high-speed videokeratoscopy

Relevância:

20.00% 20.00%

Publicador:

Resumo:

One of the key trends that we currently witness not only in academic circles but also in industry - all throughout Australia at least – is that “Innovation” is becoming an important driver for business projects, for change agendas – and in turn, for Business Process Management initiatives.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recessions impact the retail sector and as such research into consumer decision making during such times is imperative. In response to this, our study takes an innovative approach to examining how the perceived importance of retail store categories in a shopping mall influences the relationship between consumers' shopping attitudes and likelihood of purchasing in those categories during a recession. The overall findings show the importance of a product category to a consumer, which is often overlooked, has a strong explanatory influence on consumer purchase intentions for that specific retail store categories in a shopping mall under recession conditions. Findings also show that for consumers’ who have altered their shopping behaviour the perceived importance of a retail store category fully mediates the relationship for: Majors, Leisure, Food Catered and Mini Majors categories, and partial mediation for Apparel. Importance has no mediating effect for: Food Retail, General Retail, Mobile Phone Services, Home wares, and Retail Services. Our study makes a key contribution to the retail management literature with the findings suggesting that redefining and articulating the importance of the value offering for specific retail store categories can help reduce the impact of changes in consumers' recessionary shopping intentions across the mall tenant mix. Such actions can then help preserve the image of the shopping mall in the minds of the consumers when the economic recovery begins.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This chapter describes a university/high school partnership focused on digital storytelling. It also explains the multi-stage process used to establish this successful partnership and project. The authors discuss the central role that technology played in developing this university/high school partnership, a collaboration that extended the impact of a digital storytelling project to reach high school students, university students, educators, high school administrators, and the local community. Valuing a reflective process that can lead to the creation of a powerful final product, the authors describe the impact of digital storytelling on multiple stakeholders, including the 13 university students and 33 culturally and linguistically diverse high school youth who participated during the fall of 2009. In addition, the chapter includes reflections from university and high school student participants expressed during focus groups conducted throughout the project. While most participants had a positive experience with the project, complications with the technology component often caused frustrations and additional challenges. Goals for sharing this project are to critically evaluate digital storytelling, describe lessons learned, and recommend good practices for others working within a similar context or with parallel goals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Silicone hydrogel contact lenses (CLs) are becoming increasingly popular for daily wear (DW), extended wear (EW) and continuous wear (CW), due to their higher oxygen transmissibility compared to hydrogel CLs. The aim of this study was to investigate the clinical and subjective performance of asmofilcon A (Menicon Co., Ltd), a new surface treated silicone hydrogel CL, during 6-night EW over 6 months (M). Methods: A prospective, randomised, single-masked, monadic study was conducted. N=60 experienced DW soft CL wearers were randomly assigned to wear either asmofilcon A (test: Dk=129, water content (WC)=40%, Nanogloss surface treatment) or senofilcon A (control: Dk=103, WC=38%, PVP internal wetting agent, Vistakon, Johnson & Johnson Vision Care) CLs bilaterally for 6 M on an EW basis. A PHMB-preserved solution (Menicon Co., Ltd) was dispensed for CL care. Evaluations were conducted at CL delivery and after 1 week (W), 4 W, 3 M and 6 M of EW. At each visit, a range of objective and subjective clinical performance measures were assessed. Results: N=50 subjects (83%) successfully completed the study, with the majority of discontinuations due to loss to follow-up (n=3) or moving away/travel (n=5). N=2 subjects experienced adverse events; n=1 unilateral red eye with asmofilcon A and n=1 asymptomatic infiltrate with senofilcon A. There were no significant differences in high or low contrast distance visual acuity (HCDVA or LCDVA) between asmofilcon A and senofilcon A; however, LCDVA decreased significantly over time with both CL types (p<0.05). The two CL types did not vary significantly with respect to any of the objective and subjective measures assessed (p>0.05); CL fitting characteristics and CL surface measurements were very similar and mean bulbar and limbal redness measures were always less than grade 1.0. Superior palpebral conjunctival injection showed a statistically, but not clinically, significant increase over time with both CL types (p<0.05). Corneal staining did not vary significantly between asmofilcon A and senofilcon A (p>0.05), with low median gradings of less than 0.5 observed for all areas assessed. There were no solution-related staining reactions observed with either CL type. The asmofilcon A and senofilcon A CLs were both rated highly with respect to overall comfort, with medians of 14 or 15 hours of comfortable lens wearing time per day reported at each of the study visits (p>0.05). Conclusions: Over 6 months of EW, the asmofilcon A and senofilcon A CLs performed in a similar manner with respect to visual acuity, ocular health and CL performance measures. Some changes over time were observed with both CL types, including reduced LCDVA and increased superior palpebral injection, which warrant further investigation in longer-term EW studies. Asmofilcon A appeared to be equivalent in performance to senofilcon A.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Positive user experience (UX) has become a key factor in designing interactive products. It acts as a differentiator which can determine a product’s success on the mature market. However, current UX frameworks and methods do not fully support the early stages of product design and development. During these phases, assessment of UX is challenging as no actual user-product interaction can be tested. This qualitative study investigated anticipated user experience (AUX) to address this problem. Using the co-discovery method, participants were asked to imagine a desired product, anticipate experiences with it, and discuss their views with another participant. Fourteen sub-categories emerged from the data, and relationships among them were defined through co-occurrence analysis. These data formed the basis of the AUX framework which consists of two networks which elucidate 1) how users imagine a desired product and 2) how they anticipate positive experiences with that product. Through this AUX framework, important factors in the process of imagining future products and experiences were learnt, including the way in which these factors interrelate. Focusing on and exploring each component of the two networks in the framework will allow designers to obtain a deeper understanding of the required pragmatic and hedonic qualities of product, intended uses of product, user characteristics, potential contexts of experience, and anticipated emotions embedded within the experience. This understanding, in turn, will help designers to better foresee users’ underlying needs and to focus on the most important aspects of their positive experience. Therefore, the use of the AUX framework in the early stages of product development will contribute to the design for pleasurable UX.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Generic sentiment lexicons have been widely used for sentiment analysis these days. However, manually constructing sentiment lexicons is very time-consuming and it may not be feasible for certain application domains where annotation expertise is not available. One contribution of this paper is the development of a statistical learning based computational method for the automatic construction of domain-specific sentiment lexicons to enhance cross-domain sentiment analysis. Our initial experiments show that the proposed methodology can automatically generate domain-specific sentiment lexicons which contribute to improve the effectiveness of opinion retrieval at the document level. Another contribution of our work is that we show the feasibility of applying the sentiment metric derived based on the automatically constructed sentiment lexicons to predict product sales of certain product categories. Our research contributes to the development of more effective sentiment analysis system to extract business intelligence from numerous opinionated expressions posted to the Web

Relevância:

20.00% 20.00%

Publicador:

Resumo:

With the development of enterprise informatisation, Product Lifecycle Management (PLM) systems have been widely deployed and applied in enterprises. This paper analyzes the requirement that conducting version operations on business objects as specified in process models should be compliant with the versioning policies imposed by product lifecycles. This leads to the introduction of the concept of versioning compliance, and the approach of compliance checking that we proposed in our earlier work, which comprises both syntactical compatibility and behavioural compatibility checking. The paper then focuses on the tool implementation for providing automated support to the versioning compliance checking. An empirical evaluation of the tool was also performed with industrial partners using the well-known questionnaire-based method. The evaluation and feedback from practitioners further evidence the practical significance of this research question in the PLM field and demonstrate that the proposed solution with its automated tool support possesses a high application potential.