816 resultados para Computer screens
A biophysical model of atrial fibrillation ablation: what can a surgeon learn from a computer model?
Resumo:
AIMS: Surgical ablation procedures for treating atrial fibrillation have been shown to be highly successful. However, the ideal ablation pattern still remains to be determined. This article reports on a systematic study of the effectiveness of the performance of different ablation line patterns. METHODS AND RESULTS: This study of ablation line patterns was performed in a biophysical model of human atria by combining basic lines: (i) in the right atrium: isthmus line, line between vena cavae and appendage line and (ii) in the left atrium: several versions of pulmonary vein isolation, connection of pulmonary veins, isthmus line, and appendage line. Success rates and the presence of residual atrial flutter were documented. Basic patterns yielded conversion rates of only 10-25 and 10-55% in the right and the left atria, respectively. The best result for pulmonary vein isolation was obtained when a single closed line encompassed all veins (55%). Combination of lines in the right/left atrium only led to a success rate of 65/80%. Higher rates, up to 90-100%, could be obtained if right and left lines were combined. The inclusion of a left isthmus line was found to be essential for avoiding uncommon left atrial flutter. CONCLUSION: Some patterns studied achieved a high conversion rate, although using a smaller number of lines than those of the Maze III procedure. The biophysical atrial model is shown to be effective in the search for promising alternative ablation strategies.
Resumo:
The paper presents a method of analyzing Rigid Frames by use of the Conjugate Beam Theory. The development of the method along with an example is given. This method has been used to write a computer program for the analysis of twin box culverts. The culverts may be analyzed under any fill height and any of the standard truck loadings. The wall and slab thickness are increased by the computer program as necessary. The final result is steel requirements both for moment and shear, and the slab and wall thickness.
Resumo:
Three standard radiation qualities (RQA 3, RQA 5 and RQA 9) and two screens, Kodak Lanex Regular and Insight Skeletal, were used to compare the imaging performance and dose requirements of the new Kodak Hyper Speed G and the current Kodak T-MAT G/RA medical x-ray films. The noise equivalent quanta (NEQ) and detective quantum efficiencies (DQE) of the four screen-film combinations were measured at three gross optical densities and compared with the characteristics for the Kodak CR 9000 system with GP (general purpose) and HR (high resolution) phosphor plates. The new Hyper Speed G film has double the intrinsic sensitivity of the T-MAT G/RA film and a higher contrast in the high optical density range for comparable exposure latitude. By providing both high sensitivity and high spatial resolution, the new film significantly improves the compromise between dose and image quality. As expected, the new film has a higher noise level and a lower signal-to-noise ratio than the standard film, although in the high frequency range this is compensated for by a better resolution, giving better DQE results--especially at high optical density. Both screen-film systems outperform the phosphor plates in terms of MTF and DQE for standard imaging conditions (Regular screen at RQA 5 and RQA 9 beam qualities). At low energy (RQA 3), the CR system has a comparable low-frequency DQE to screen-film systems when used with a fine screen at low and middle optical densities, and a superior low-frequency DQE at high optical density.
Resumo:
We report on the study of nonequilibrium ordering in the reaction-diffusion lattice gas. It is a kinetic model that relaxes towards steady states under the simultaneous competition of a thermally activated creation-annihilation $(reaction$) process at temperature T, and a diffusion process driven by a heat bath at temperature T?T. The phase diagram as one varies T and T, the system dimension d, the relative priori probabilities for the two processes, and their dynamical rates is investigated. We compare mean-field theory, new Monte Carlo data, and known exact results for some limiting cases. In particular, no evidence of Landau critical behavior is found numerically when d=2 for Metropolis rates but Onsager critical points and a variety of first-order phase transitions.
Resumo:
We present a computer-simulation study of the effect of the distribution of energy barriers in an anisotropic magnetic system on the relaxation behavior of the magnetization. While the relaxation law for the magnetization can be approximated in all cases by a time logarithmic decay, the law for the dependence of the magnetic viscosity with temperature is found to be quite sensitive to the shape of the distribution of barriers. The low-temperature region for the magnetic viscosity never extrapolates to a positive no-null value. Moreover our computer simulation results agree reasonably well with some recent relaxation experiments on highly anisotropic single-domain particles.
Resumo:
Abstract
Resumo:
This paper presents SiMR, a simulator of the Rudimentary Machine designed to be used in a first course of computer architecture of Software Engineering and Computer Engineering programmes. The Rudimentary Machine contains all the basic elements in a RISC computer, and SiMR allows editing, assembling and executing programmes for this processor. SiMR is used at the Universitat Oberta de Catalunya as one of the most important resources in the Virtual Computing Architecture and Organisation Laboratory, since students work at home with the simulator and reports containing their work are automatically generated to be evaluated by lecturers. The results obtained from a survey show that most of the students consider SiMR as a highly necessary or even an indispensable resource to learn the basic concepts about computer architecture.
Resumo:
OBJECTIVES: Many patients may believe that HIV screening is included in routine preoperative work-ups. We examined what proportion of patients undergoing preoperative blood testing believed that they had been tested for HIV. METHODS: All patients hospitalized for elective orthopaedic surgery between January and December 2007 were contacted and asked to participate in a 15-min computer-assisted telephone interview (n = 1330). The primary outcome was to determine which preoperative tests patients believed had been performed from a choice of glucose, clotting, HIV serology and cholesterol, and what percentage of patients interpreted the lack of result communication as a normal or negative test. The proportion of patients agreeable to HIV screening prior to future surgery was also determined. RESULTS: A total of 991 patients (75%) completed the questionnaire. Three hundred and seventy-five of these 991 patients (38%) believed incorrectly that they had been tested for HIV preoperatively. Younger patients were significantly more likely to believe that an HIV test had been performed (mean age 46 vs. 50 years for those who did not believe that an HIV test had been performed; P < 0.0001). Of the patients who believed that a test had been performed but received no result, 96% interpreted lack of a result as a negative HIV test. Over 80% of patients surveyed stated that they would agree to routine HIV screening prior to future surgery. A higher acceptance rate was associated with younger age (mean age 47 years for those who would agree vs. 56 years for those who would not; P < 0.0001) and male sex ( P < 0.009). CONCLUSIONS: Many patients believe that a preoperative blood test routinely screens for HIV. The incorrect assumption that a lack of result communication indicates a negative test may contribute to delays in HIV diagnoses.
Resumo:
The purpose of this study is to clinically validate a new two-dimensional preoperative planning software for cementless total hip arthroplasty (THA). Manual and two-dimensional computer-assisted planning were compared by an independent observer for each of the 30 patients with osteoarthritis who underwent THA. This study showed that there were no statistical differences between the results of both preoperative plans in terms of stem size and neck length (<1 size) and hip rotation center position (<5 mm). Two-dimensional computer-assisted preoperative planning provided successful results comparable to those using the manual procedure, thereby allowing the surgeon to simulate various stem designs easily.
Resumo:
PURPOSE: To prospectively evaluate the accuracy and reliability of "freehand" posttraumatic orbital wall reconstruction with AO (Arbeitsgemeinschaft Osteosynthese) titanium mesh plates by using computer-aided volumetric measurement of the bony orbits. METHODS: Bony orbital volume was measured in 12 patients from coronal CT scan slices using OsiriX Medical Image software. After defining the volumetric limits of the orbit, the segmentation of the bony orbital region of interest of each single slice was performed. At the end of the segmentation process, all regions of interest were grouped and the volume was computed. The same procedure was performed on both orbits, and thereafter the volume of the contralateral uninjured orbit was used as a control for comparison. RESULTS: In all patients, the volume data of the reconstructed orbit fitted that of the contralateral uninjured orbit with accuracy to within 1.85 cm3 (7%). CONCLUSIONS: This preliminary study has demonstrated that posttraumatic orbital wall reconstruction using "freehand" bending and placement of AO titanium mesh plates results in a high success rate in re-establishing preoperative bony volume, which closely approximates that of the contralateral uninjured orbit.