939 resultados para Bones Radiography
Resumo:
ABSTRACT: BACKGROUND: Pelvic x-ray is a routine part of the primary survey of polytraumatized patients according to Advanced Trauma Life Support (ATLS) guidelines. However, pelvic CT is the gold standard imaging technique in the diagnosis of pelvic fractures. This study was conducted to confirm the safety of a modified ATLS algorithm omitting pelvic x-ray in hemodynamically stable polytraumatized patients with clinically stable pelvis in favour of later pelvic examination by CT scan. METHODS: We conducted a retrospective analysis of all polytraumatized patients in our emergency room between 01.07.2004 and 31.01.2006. Inclusion criteria were blunt abdominal trauma, initial hemodynamic stability and a stable pelvis on clinical examination. We excluded patients requiring immediate intervention because of hemodynamic instability. RESULTS: We reviewed the records of n = 452 polytraumatized patients, of which n = 91 fulfilled inclusion criteria (56% male, mean age = 45 years). The mechanism of trauma included 43% road traffic accidents, 47% falls. In 68/91 (75%) patients, both a pelvic x-ray and a CT examination were performed; the remainder had only pelvic CT. In 6/68 (9%) patients, pelvic fracture was diagnosed by pelvic x-ray. None of these 6 patients was found having a false positive pelvic x-ray, i.e. there was no fracture on pelvic CT scan. In 3/68 (4%) cases a fracture was missed in the pelvic x-ray, but confirmed on CT (false negative on x-ray). None of the diagnosed fractures needed an immediate therapeutic intervention. 5 (56%) were classified type A fractures, and another 4 (44%) B 2.1 in computed tomography (AO classification). One A 2.1 fracture was found in a clinically stable patient who only received CT scan (1/23). CONCLUSION: While pelvic x-ray is an integral part of ATLS assessment, this retrospective study suggests that in hemodynamically stable patients with clinically stable pevis, its sensitivity is only 67% and it may safely be omitted in favor of a pelvic CT examination if such is planned in adjunct assessment and available. The results support the safety and utility of our modified ATLS algorithm. A randomized controlled trial using the algorithm can safely be conducted to confirm the results.
Resumo:
ATLS Guidelines recommend single plain radiography of the chest and pelvis as part of the primary survey. Such isolated radiographs, usually obtained by bedside machines, can result in limited, low-quality studies that can adversely affect management. A new digital, low-radiation imaging device, the "Lodox Statscan" (LS), provides full-body anterior and lateral views based on enhanced linear slot-scanning technology in just over 5 minutes. We have the first LS in Europe at our facility. The aim of this study was to compare LS with computed tomographic (CT) scanning, as the gold standard, to determine the sensitivity of LS investigation in detecting injuries to the chest, thoracolumbar spine, and pelvis from our own experience, and to compare our findings with those of conventional radiography in the literature.
Resumo:
AIM: To compare intraoral occlusal (OC) and periapical (PA) radiographs vs. limited cone beam computed tomography (CBCT) in diagnosing root-fractured permanent teeth. MATERIAL AND METHODS: In 38 patients (mean age 24 years, range 8-52 years) with 44 permanent teeth with horizontal root fractures, intraoral radiographs (PA and OC) and limited CBCT were used to evaluate the location (apical, middle, cervical third of the root) and angulation of the fracture line. Furthermore, the conventional radiographs and CBCT images were compared for concordance of fracture location. RESULTS: In the PA and OC radiographs, 28 fractures (63.6%) were located in the middle third of the root, 11 (25.0%) in the apical third and 5 (11.4%) in the cervical third. The PA/OC radiographs and the sagittal CBCT images (facial aspect) yielded the same level of root fracture in 70.5% of cases (31 teeth; 95% CI: 54.1-82.7%). The PA/OC radiographs and sagittal CBCT images (palatal aspect) showed the same level of root fracture in 31.8% of cases. There was a statistically significant association between the angle at which the root fracture line intersected the axis of the tooth and the level of root fracture in the facial aspect of the sagittal CBCT images. CONCLUSIONS: The diagnosis of the location and angulation of root fractures based on limited CBCT imaging differs significantly from diagnostic procedures based on intraoral radiographs (PA/OC) alone. The clinical significance for treatment strategies and for the prognosis of root-fractured teeth has to be addressed in future studies.
Resumo:
OBJECTIVES: To demonstrate the feasibility of panoramic image subtraction for implant assessment. STUDY DESIGN: Three titanium implants were inserted into a fresh pig mandible. One intraoral and 2 panoramic images were obtained at baseline and after each of 6 incremental (0.3, 0.6, 1.0, 1.5, 2.0, 2.5 mm) removals of bone. For each incremental removal of bone, the mandible was removed from and replaced in the holding device. Images representing incremental bone removals were registered by computer with the baseline images and subtracted. Assessment of the subtraction images was based on visual inspection and analysis of structured noise. RESULTS: Incremental bone removals were more visible in intraoral than in panoramic subtraction images; however, computer-based registration of panoramic images reduced the structured noise and enhanced the visibility of incremental removals. CONCLUSION: The feasibility of panoramic image subtraction for implant assessment was demonstrated.
Resumo:
The aim of this study was to simulate direct-digital cephalometric procedures and to record the head movements of probands. This study was prompted by the Committee for Insurance Matters of the Swiss National Invalidity Insurance which does not accept scanned digital cephalometric radiographs as a basis for its decisions. The reason for this is the required scanning time of several seconds during which even slight head movements can lead to kinetic blurring and landmark displacement. Incorrect angular measurements may result. By means of a Sirognathograph and a cephalostat of non-ferromagnetic material, the head movements of a total of 264 subjects were recorded in three dimensions, with a scanning time of up to 25 seconds. In a second series, the influence of a chin support to reduce head movements was also tested. The results of the first series of tests showed that, with an increasing scan time, movements became greater, mostly in the sagittal plane, and that maximum displacements could occur already at the start of the recording. With a scan time of 10 seconds the median movement amplitude in the vertical dimension was 2.14 mm. The second series of tests revealed a significant reduction in head movements in all dimensions owing to an additional stabilizing chin support. To minimize head movements, scanning times must be reduced and additional head stabilizing elements together with existing ones are necessary.
Resumo:
OBJECTIVE: In this experimental study we assessed the diagnostic performance of digital linear slit scanning radiography compared with computed radiography (CR) for the detection of urinary calculi in an anthropomorphic phantom imitating patients weighing approximately 58-88 kg. CONCLUSION: Compared with CR, linear slit scanning radiography is superior for the detection of urinary stones and may be used for pretreatment localization and follow-up at a lower patient exposure.
Resumo:
The purpose of this retrospective study was to intra-individually compare the image quality of computed radiography (CR) and low-dose linear-slit digital radiography (LSDR) for supine chest radiographs. A total of 90 patients (28 female, 62 male; mean age, 55.1 years) imaged with CR and LSDR within a mean time interval of 2.8 days +/- 3.0 were included in this study. Two independent readers evaluated the image quality of CR and LSDR based on modified European Guidelines for Quality Criteria for chest X-ray. The Wilcoxon test was used to analyse differences between the techniques. The overall image quality of LSDR was significantly better than the quality of CR (9.75 vs 8.16 of a maximum score of 10; p < 0.001). LSDR performed significantly better than CR for delineation of anatomical structures in the mediastinum and the retrocardiac lung (p < 0.001). CR was superior to LSDR for visually sharp delineation of the lung vessels and the thin linear structures in the lungs. We conclude that LSDR yields better image quality and may be more suitable for excluding significant pathological features of the chest in areas with high attenuation compared with CR.
Resumo:
Recent clinical trials have reported favorable early results for transpedicular vertebral cement reinforcement of osteoporotic vertebral insufficiencies. There is, however, a lack of basic data on the application, safety and biomechanical efficacy of materials such as polymethyl-methacrylate (PMMA) and calciumphospate (CaP) cements. The present study analyzed 33 vertebral pairs from five human cadaver spines. Thirty-nine vertebrae were osteoporotic (bone mineral density < 0.75 g/cm2), 27 showed nearly normal values. The cranial vertebra of each pair was augmented with either PMMA (Palacos E-Flow) or experimental brushite cement (EBC), with the caudal vertebra as a control. PMMA and EBC were easy to inject, and vertebral fillings of 20-50% were achieved. The maximal possible filling was inversely correlated to the bone mineral density (BMD) values. Cement extrusion into the spinal canal was observed in 12% of cases. All specimens were subjected to axial compression tests in a displacement-controlled mode. From load-displacement curves, the stiffness, S, and the maximal force before failure, Fmax, were determined. Compared with the native control vertebrae, a statistically significant increase in vertebral stiffness and Fmax was observed by the augmentation. With PMMA the stiffness increased by 174% (P = 0.018) and Fmax by 195% (P = 0.001); the corresponding augmentation with EBC was 120% (P = 0.03) and 113% (P = 0.002). The lower the initial BMD, the more pronounced was the augmentation effect. Both PMMA and EBC augmentation reliably and significantly raised the stiffness and maximal tolerable force until failure in osteoporotic vertebral bodies. In non-porotic specimens, no significant increase was achieved.
Resumo:
This paper presents problems arising from the lack of standardized methods for recording skeletal remains. Using practical examples it is shown how preservation and representation of bones can distort observations and how this can be reduced by systematic data acquisition.
Resumo:
REASONS FOR PERFORMING STUDY: There is limited information on potential diffusion of local anaesthetic solution after various diagnostic analgesic techniques of the proximal metacarpal region. OBJECTIVE: To document potential distribution of local anaesthetic solution following 4 techniques used for diagnostic analgesia of the proximal metacarpal region. METHODS: Radiodense contrast medium was injected around the lateral palmar or medial and lateral palmar metacarpal nerves in 8 mature horses, using 4 different techniques. Radiographs were obtained 0, 10 and 20 min after injection and were analysed subjectively. A mixture of radiodense contrast medium and methylene blue was injected into 4 cadaver limbs; the location of the contrast medium and dye was determined by radiography and dissection. RESULTS: Following perineural injection of the palmar metacarpal nerves, most of the contrast medium was distributed in an elongated pattern axial to the second and fourth metacarpal bones. The carpometacarpal joint was inadvertently penetrated in 4/8 limbs after injections of the palmar metacarpal nerves from medial and lateral approaches, and in 1/8 limbs when both injections were performed from the lateral approach. Following perineural injection of the lateral palmar nerve using a lateral approach, the contrast medium was diffusely distributed in all but one limb, in which the carpal sheath was inadvertently penetrated. In 5/8 limbs, following perineural injection of the lateral palmar nerve using a medial approach, the contrast medium diffused proximally to the distal third of the antebrachium. CONCLUSIONS AND POTENTIAL RELEVANCE: Inadvertent penetration of the carpometacarpal joint is common after perineural injection of the palmar metacarpal nerves, but less so if both palmar metacarpal nerves are injected using a lateral approach. Following injection of the lateral palmar nerve using a medial approach, the entire palmar aspect of the carpus may be desensitised.
Resumo:
OBJECTIVE The purpose of this study was to investigate the feasibility of microdose CT using a comparable dose as for conventional chest radiographs in two planes including dual-energy subtraction for lung nodule assessment. MATERIALS AND METHODS We investigated 65 chest phantoms with 141 lung nodules, using an anthropomorphic chest phantom with artificial lung nodules. Microdose CT parameters were 80 kV and 6 mAs, with pitch of 2.2. Iterative reconstruction algorithms and an integrated circuit detector system (Stellar, Siemens Healthcare) were applied for maximum dose reduction. Maximum intensity projections (MIPs) were reconstructed. Chest radiographs were acquired in two projections with bone suppression. Four blinded radiologists interpreted the images in random order. RESULTS A soft-tissue CT kernel (I30f) delivered better sensitivities in a pilot study than a hard kernel (I70f), with respective mean (SD) sensitivities of 91.1% ± 2.2% versus 85.6% ± 5.6% (p = 0.041). Nodule size was measured accurately for all kernels. Mean clustered nodule sensitivity with chest radiography was 45.7% ± 8.1% (with bone suppression, 46.1% ± 8%; p = 0.94); for microdose CT, nodule sensitivity was 83.6% ± 9% without MIP (with additional MIP, 92.5% ± 6%; p < 10(-3)). Individual sensitivities of microdose CT for readers 1, 2, 3, and 4 were 84.3%, 90.7%, 68.6%, and 45.0%, respectively. Sensitivities with chest radiography for readers 1, 2, 3, and 4 were 42.9%, 58.6%, 36.4%, and 90.7%, respectively. In the per-phantom analysis, respective sensitivities of microdose CT versus chest radiography were 96.2% and 75% (p < 10(-6)). The effective dose for chest radiography including dual-energy subtraction was 0.242 mSv; for microdose CT, the applied dose was 0.1323 mSv. CONCLUSION Microdose CT is better than the combination of chest radiography and dual-energy subtraction for the detection of solid nodules between 5 and 12 mm at a lower dose level of 0.13 mSv. Soft-tissue kernels allow better sensitivities. These preliminary results indicate that microdose CT has the potential to replace conventional chest radiography for lung nodule detection.
Resumo:
End caps are intended to prevent nail migration (push-out) in elastic stable intramedullary nailing. The aim of this study was to investigate the force at failure with and without end caps, and whether different insertion angles of nails and end caps would alter that force at failure. Simulated oblique fractures of the diaphysis were created in 15 artificial paediatric femurs. Titanium Elastic Nails with end caps were inserted at angles of 45°, 55° and 65° in five specimens for each angle to create three study groups. Biomechanical testing was performed with axial compression until failure. An identical fracture was created in four small adult cadaveric femurs harvested from two donors (both female, aged 81 and 85 years, height 149 cm and 156 cm, respectively). All femurs were tested without and subsequently with end caps inserted at 45°. In the artificial femurs, maximum force was not significantly different between the three groups (p = 0.613). Push-out force was significantly higher in the cadaveric specimens with the use of end caps by an up to sixfold load increase (830 N, standard deviation (SD) 280 vs 150 N, SD 120, respectively; p = 0.007). These results indicate that the nail and end cap insertion angle can be varied within 20° without altering construct stability and that the risk of elastic stable intramedullary nailing push-out can be effectively reduced by the use of end caps.