920 resultados para Aortic Valve Stenosis
Resumo:
Background: Heart failure (CHF) is the most frequent and prognostically severe symptom of aortic stenosis (AS), and the most common indication for surgery. The mainstay of treatment for AS is aortic valve replacement (AVR), and the main indication for an AVR is development of symptomatic disease. ACC/AHA guidelines define severe AS as an aortic valve area (AVA) ≤1cm², but there is little data correlating echocardiogram AVA with the onset of symptomatic CHF. We evaluated the risk of developing CHF with progressively decreasing echocardiographic AVA. We also compared echocardiographic AVA with Jet velocity (V2) and indexed AVA (AVAI) to assess the best predictor of development of symptomatic CHF.^ Methods and Results: This retrospective cohort study evaluated 518 patients with asymptomatic moderate or severe AS from a single community based cardiology practice. A total of 925 echocardiograms were performed over an 11-year period. Each echocardiogram was correlated with concurrent clinical assessments while the investigator was blinded to the echocardiogram severity of AS. The Cox Proportional hazards model was used to analyze the relationship between AVA and the development of CHF. The median age of patients at entry was 76.1 years, with 54% males. A total of 116 patients (21.8%) developed new onset CHF during follow-up. Compared to patients with AVA >1.0cm², patients with lower AVA had an exponentially increasing risk of developing CHF for each 0.2cm² decrement in AVA, becoming statistically significant only at an AVA less than 0.8 cm². Also, compared to V2 and AVAI, AVA added more information to assessing risk for development of CHF (p=0.041). ^ Conclusion: In patients with normal or mildly impaired LVEF, the risk of CHF rises exponentially with decreasing valve area and becomes statistically significant after AVA falls below 0.8cm². AVA is a better predictor of CHF when compared to V2 or AVAI.^
Resumo:
Two cases of Shone syndrome with severe mitral and aortic valve problems and pulmonary hypertension were referred for heart-lung transplantation. Severely elevated pulmonary vascular resistance (PVR) was confirmed as was severe periprosthetic mitral and aortic regurgitation. Based on the severity of the valve lesions in both patients, surgery was decided upon and undertaken. Both experienced early pulmonary hypertensive crises, one more than the other, that gradually subsided, followed by excellent recovery and reversal of pulmonary hypertension and PVR. These cases illustrate Braunwald's concept that pulmonary hypertension secondary to left-sided valve disease is reversible.
Resumo:
L’hypertrophie du ventricule gauche est une complication fréquente chez les gens souffrant de sténose aortique. Lorsque ces patients subissent un remplacement de la valve aortique, l’ampleur de la régression de l’hypertrophie dépend de plusieurs facteurs hémodynamiques qui sont peu ou pas modifiables. Dans ce travail, l’implication de la parathormone dans l’hypertrophie du ventricule gauche chez ces patients a été évaluée. Il s’agit d’une étude transversale comptant 195 patients recrutés 8±3,5 ans après leur chirurgie. La fonction et la masse ventriculaire gauche ont été évaluées par échocardiographie Doppler. Des mesures du niveau plasmatique de parathormone, de vitamine D, de calcium et de phosphate ont été obtenues. Les résultats démontrent que le niveau de parathormone est associé de façon indépendante et significative avec la masse ventriculaire gauche et l’hypertrophie du ventricule gauche. De plus, le niveau de vitamine D et la fonction rénale étaient en corrélation inverse avec le niveau de parathormone.
Resumo:
In this study, we show the use of three-dimensional printing models for preoperative planning of transcatheter valve replacement in a patient with an extreme porcelain aorta. A 70-year-old man with severe aortic stenosis and a porcelain aorta was referred to our center for transcatheter aortic valve replacement. Unfortunately, the patient died after the procedure because of a potential ischemic event. Therefore, we decided to fabricate three-dimensional models to evaluate the potential effects of these constructs for previous surgical planning and simulation of the transcatheter valve replacement.
Resumo:
Recently developed technologies allow aortic valve implantation off-pump in a beating heart. In this procedure, the native, stenotic aortic valve is not removed, but simply crushed by a pressure balloon mounted on a percutaneous catheter. Removal of the native aortic cusps before valve replacement may reduce the incidence of annular or cuspal calcium embolization and late perivalvular leaks and increase implantable valve size. However, a temporary valve system in the ascending aorta may be necessary to maintain hemodynamic stability by reducing acute aortic regurgitation and left ventricular volume overload. This study evaluates the hemodynamic effects of a wire-mounted, monoleaflet, temporary valve apparatus in a mechanical cardiovascular simulator. Aortic flow, systemic pressure and left ventricular pressure were continuously monitored. An intraluminal camera obtained real-time proximal and distal images of the valve in operation. Insertion of the parachute valve in the simulator increased diastolic pressure from 7 to 38 mm Hg. Cardiac output increased from 2.08 to 4.66 L/min and regurgitant volume decreased from 65 to 23 mL. In conclusion, placement of a temporary valve in the ascending aorta may help maintain hemodynamic stability and improve off-pump aortic valve replacement.
Resumo:
OBJECTIVES This study reports a series of pitfalls, premature failures and explantations of the third-generation Freedom SOLO (FS) bovine pericardial stentless valve. METHODS A total of 149 patients underwent aortic valve replacement using the FS. Follow-up was 100% complete with an average observation time of 5.5 ± 2.3 years (maximum 8.7 years) and a total of 825 patient-years. Following intraoperative documentation, all explanted valve prostheses underwent histological examination. RESULTS Freedom from structural valve deterioration (SVD) at 5, 6, 7, 8 and 9 years was 92, 88, 80, 70 and 62%, respectively. Fourteen prostheses required explantation due to valve-independent dysfunction (n = 5; i.e. thrombus formation, oversizing, aortic dilatation, endocarditis and suture dehiscence) or valve-dependent failure (acute leaflet tears, n = 4 and severe stenosis, n = 5). Thus, freedom from explantation at 5, 6, 7, 8 and 9 years was 95, 94, 91, 81 and 72%, respectively. An acute vertical tear along the non-coronary/right coronary commissure to the base occurred at a mean of 6.0 years (range 4.3-7.3 years) and affected size 25 and 27 prostheses exclusively. Four FS required explantation after a mean of 7.5 years (range 7.0-8.3 years) due to severe functional stenosis and gross calcification that included the entire aortic root. CONCLUSIONS The FS stentless valve is safe to implant and shows satisfying mid-term results in our single institution experience. Freedom from SVD and explantation decreased markedly after only 6-7 years, so that patients with FS require close observation and follow-up. Exact sizing, symmetric positioning and observing patient limitations are crucial for optimal outcome.
Resumo:
Numerous designs of bioprosthetic valves exist. The sutureless surgical valve is a newer design concept which combines elements of the transcatheter valve technology with surgical valves. This design aims at shorter and easier implantation. It was the aim of this study to perform hemodynamic and kinematic measurements for this type of valves to serve as a baseline for following studies which investigate the effect of the aortic root on the valve performance. To this end, the Edwards Intuity aortic valve was investigated in a new in vitro flow loop mimicking the left heart. The valve was implanted in a transparent, compliant aortic root model, and the valve kinematics was investigated using a high speed camera together with synchronized hemodynamic measurements of pressures and flows. The valve closure was asynchronous (one by one leaflet), and the valve started to close before the deceleration of the fluid. The aortic root model showed a dilation of the sinuses which was different to the ascending aorta, and the annulus was found to move towards the left ventricle during diastole and towards the aorta during systole.
Resumo:
Gebiet: Chirurgie Abstract: Objectives This study reports a series of pitfalls, premature failures and explantations of the third generation Freedom SOLO bovine pericardial stentless valve. – – Methods 149 patients underwent aortic valve replacement (AVR) using the FS. Follow-up was 100% complete with an average observation time of 5.5±2.3 years (max. 8.7 years) and a total of 825 patient years. Following intraoperative documentation, all explanted valve prostheses underwent histological examination. – – Results Freedom from structural valve deterioration (SVD) at 5, 6, 7, 8 and 9 years was 92%, 88%, 80% and 70% and 62%, respectively. 14 prostheses required explantation due to valve-independent dysfunction (n=5, i.e. thrombus formation, oversizing, aortic dilatation, endocarditis and suture dehiscence) or valve-dependent failure (acute leaflet tears, n=4, severe stenosis, n=5). Thus freedom from explantation at 5, 6, 7, 8 and 9 years was 95%, 94%, 91% and 81% and 72%, respectively. An acute vertical tear along the non-coronary/right-coronary commissure to the base occurred at a mean of 6.0 years [range 4.3?7.3 years] and affected size 25 and 27 prostheses exclusively. Four FS required explantation after a mean of 7.5 years [range 7.0?8.3 years] due to severe functional stenosis and gross calcification that included the entire aortic root. – – Conclusions The Freedom SOLO stentless valve is safe to implant and shows satisfying mid-term results in our single institution experience. Freedom from SVD and explantation decreased markedly after only 6 ? 7 years, so that patients with FS require close observation and follow-up. Exact sizing, symmetric positioning and observing patient limitations are crucial for optimal outcome.
Resumo:
Background. The development of therapeutic interventions to prevent progressive valve damage is more likely to limit the progression of structural damage to the aortic valve with normal function (aortic sclerosis [ASC]) than clinically apparent aortic stenosis. Currently, the ability to appreciate the progression of ASC is compromised by the subjective and qualitative evaluation of sclerosis severity. Methods: We sought to reveal whether the intensity of ultrasonic backscatter could be used to quantify sclerosis severity in 26 patients with ASC and 23 healthy young adults. images of the aortic valve were obtained in the parasternal long-axis view and saved in raw data format. Six square-shaped 11 X 11 pixel regions of interest were placed on the anterior and posterior leaflets, and calibrated backscatter values were obtained by subtracting the regions of interest in the blood pool from the averaged backscatter values obtained from the leaflets. Results. Mean ultrasonic backscatter values for sclerotic valves exceeded the results in normal valve tissue (16.3 +/- 4.4 dB vs 9.8 +/- 3.3 dB, P < .0001). Backscatter values were greater (22.0 +/- 3.5 dB) in a group of 6 patients with aortic stenosis. Within the sclerosis group, the magnitude of backscatter was directly correlated (P < .05) with a subjective sclerosis score, and with transvalvular pressure gradient. mean reproducibility was 2.4 +/- 1.8 dB (SD) between observers, and 2.3 +/- 1.7 dB (SD) between examinations. Conclusion: Measurement of backscatter from the valve leaflets of patients with ASC may be a feasible means of following the progression and treatment response of aortic sclerosis.
Resumo:
Current artificial heart valves are classified as mechanical and bioprosthetic. An appealing pathway that promises to overcome the shortcomings of commercially available heart valves is offered by the interdisciplinary approach of cardiovascular tissue engineering. However, the mechanical properties of the Tissue Engineering Heart Valves (TEHV) are limited and generally fail in the long-term use. To meet this performance challenge novel biodegradable triblock copolymer poly(ethylene oxide)-polypropylene oxide)-poly(ethylene oxide) (PEO-PPO-PEO or F108) crosslinked to Silk Fibroin (F108-SilkC) to be used as tri-leaflet heart valve material was investigated. ^ Synthesis of ten polymers with varying concentration and thickness (55 µm, 75 µm and 100 µm) was achieved via a covalent crosslinking scheme using bifunctional polyethylene glycol diglycidyl ether (PEGDE). Static and fatigue testing were used to assess mechanical properties of films, and hydrodynamic testing was performed to determine performance under a simulated left ventricular flow regime. The crosslinked copolymer (F108-Silk C) showed greater flexibility and resilience, but inferior ultimate tensile strength, by increasing concentration of PEGDE. Concentration molar ratio of 80:1 (F108: Silk) and thickness of 75 µm showed longer fatigue life for both tension-tension and bending fatigue tests. Four valves out of twelve designed satisfactorily complied with minimum performance requirement ISO 5840, 2005. ^ In conclusion, it was demonstrated that the applicability of a degradable polymer in conjugation with silk fibroin for tissue engineering cardiovascular use, specifically for aortic valve leaflet design, met the performance demands. Thinner thicknesses (t<75 µm) in conjunction with stiffness lower than 320 MPa (80:1, F108: Silk) are essential for the correct functionality of proposed heart valve biomaterial F108-SilkC. Fatigue tests were demonstrated to be a useful tool to characterize biomaterials that undergo cyclic loading. ^
Resumo:
La sténose aortique est la cardiopathie valvulaire la plus fréquente retrouvée chez les patients agés. Suite à l’apparition des symptômes, la survie des patients diminue de façon drastique en l’absence d’un remplacement valvulaire aortique. Cependant, une proportion considérable de ces patients n’est pas opérée en raison d’un risque chirurgical élevé, l’âge étant l’une des principales raisons de refus d’un remplacement valvulaire aortique chirurgical. Ce défaut dans la prise en charge des ces patients a favorisé le développement du remplacement valvulaire aortique par cathéter où implantation valvulaire aortique par cathèter (TAVR ou TAVI), qui a représenté une révolution dans le traitement de la sténose aortique. Cette intervention est actuellement un traitement de routine chez les patients à haut risque chirurgical atteints d’une sténose aortique, même si la chirurgie cardiaque n’est pas contre-indiquée. Ces dernières années ont vu un changement de profil des candidats potentiels vers une population à plus faible risque. Cependant, plusieurs préoccupations demeurent. L’une des plus importantes est la survenue des arythmies et de troubles de conduction, notamment le bloc de branche gauche et le bloc auriculo-ventriculaire, qui sont des complications fréquemment associées au TAVR. Malgré l’évolution de la technologie et le développement de nouveaux dispositifs réduisant le taux global de complications, aucune amélioration n’a pas été intégrée pour prévenir l’apparition de telles complications. De plus, l’utilisation de certains dispositifs de nouvelle génération semble être associée à un risque accru de troubles de conduction, et par conséquent, l’incidence de ces complications pourrait augmenter dans le futur. Cependant, L’impact et l’évolution de ces complications sont inconnus. Ce travail de recherche évalue l’incidence et l’évolution des troubles de conduction suite au TAVR et l’impact des blocs de branche gauche de novo et de l’implantation d’un pacemaker sur les résultats cliniques et échocardiographiques.
Resumo:
L’évaluation de la sténose aortique (SA) par échocardiographie Doppler aboutit à une classification discordante de la sévérité chez environ 30 % des patients. La tomodensitométrie qui mesure la calcification valvulaire aortique, un indice de sévérité anatomique, peut alors être utile pour corroborer la sévérité de la SA. De précédentes études ont montré une bonne corrélation entre la sévérité hémodynamique mesurée par échocardiographie Doppler et la sévérité anatomique définie par la calcification valvulaire aortique mesurée par tomodensitométrie. Cependant, l’impact du phénotype de la valve aortique (bicuspide versus tricuspide) et de l’âge sur cette relation entre sévérité hémodynamique et sévérité anatomique reste inconnu. Or, ces deux facteurs sont hautement impliqués dans le développement de la SA. En effet, les patients ayant une valve aortique bicuspide ont une prédisposition à développer une SA, et ce, généralement plus tôt que les patients avec une valve aortique tricuspide. L’hypothèse principale de l’étude est que le phénotype de la valve aortique et l’âge influencent la relation entre la sévérité hémodynamique et la calcification valvulaire aortique de la SA. L’objectif principal de l’étude est d’évaluer l’impact du phénotype de la valve aortique et de l’âge sur la relation entre la sévérité hémodynamique et la calcification valvulaire aortique de la SA.
Resumo:
Dissertação de mestrado, Engenharia de Sistemas e Computação, Unidade de Ciências Exactas e Humanas, Universidade do Algarve, 1997
Resumo:
Le rétrécissement valvulaire aortique calcifié (RAC) est le trouble valvulaire le plus fréquent chez les personnes âgées des pays développés. La seule option de traitement possible le remplacement de la valve aortique. L’identification du rôle de l’enzyme ecto-nucleotidase NPP1 dans le processus de calcification suggère que cette enzyme pourrait être une cible potentielle pour le développement d’un inhibiteur pharmacologique contre la calcification de la valve aortique. Jusqu’à présent, les composés qui ont été développés en tant qu’inhibiteurs de NPP1 manquent de puissance et de spécificité. Dans la présente étude, nous avons démontré que les dérivés de sulfonamides quinazolin-4-pipéridine sont des inhibiteurs puissants, spécifiques, et non-compétitifs de NPP1. In vitro, dans des cellules isolées de valve aortique nous avons fourni des preuves que l’inhibition de NPP1 par ces dérivés bloque la minéralisation, l’apoptose et la transition ostéogénique des cellules interstitielles de valve aortique.
Resumo:
This is a case report of a 43-year-old Caucasian male with end-stage renal disease being treated with hemodialysis and infective endocarditis in the aortic and tricuspid valves. The clinical presentation was dominated by neurologic impairment with cerebral embolism and hemorrhagic components. A thoracoabdominal computerized tomography scan revealed septic pulmonary embolus. The patient underwent empirical antibiotherapy with ceftriaxone, gentamicin and vancomycin, and the therapy was changed to flucloxacilin and gentamicin after the isolation of S. aureus in blood cultures. The multidisciplinary team determined that the patient should undergo valve replacement after the stabilization of the intracranial hemorrhage; however, on the 8th day of hospitalization, the patient entered cardiac arrest due to a massive septic pulmonary embolism and died. Despite the risk of aggravation of the hemorrhagic cerebral lesion, early surgical intervention should be considered in high-risk patients.