992 resultados para Antigen detection
Resumo:
Globally, Prostate cancer (PCa) is the most frequently occurring non-cutaneous cancer, and is the second highest cause of cancer mortality in men. Serum prostate specific antigen (PSA) has been the standard in PCa screening since its approval by the American Food & Drug Administration (FDA) in 1994. Currently, PSA is used as an indicator for PCa - patients with a serum PSA level above 4ng/mL will often undergo prostate biopsy to confirm cancer. Unfortunately fewer than similar to 30% of these men will biopsy positive for cancer, meaning that the majority of men undergo invasive biopsy with little benefit. Despite PSA's notoriously poor specificity (33%), there is still a significant lack of credible alternatives. Therefore an ideal biomarker that can specifically detect PCa at an early stage is urgently required. The aim of this study was to investigate the potential of using deregulation of urinary proteins in order to detect Prostate Cancer (PCa) among Benign Prostatic Hyperplasia (BPH). To identify the protein signatures specific for PCa, protein expression profiling of 8 PCa patients, 12 BPH patients and 10 healthy males was carried out using LC-MS/MS. This was followed by validating relative expression levels of proteins present in urine among all the patients using quantitative real time-PCR. This was followed by validating relative expression levels of proteins present in urine among all the patients using quantitative real time-PCR. This approach revealed that significant the down-regulation of Fibronectin and TP53INP2 was a characteristic event among PCa patients. Fibronectin mRNA down-regulation, was identified as offering improved specificity (50%) over PSA, albeit with a slightly lower although still acceptable sensitivity (75%) for detecting PCa. As for TP53INP2 on the other hand, its down-regulation was moderately sensitive (75%), identifying many patients with PCa, but was entirely non-specific (7%), designating many of the benign samples as malignant and being unable to accurately identify more than one negative.
Resumo:
As an immunogen of the coronavirus, the nucleoprotein (N) is a potential antigen for the serological monitoring of infectious bronchitis virus (IBV). In this report, recombinant N protein from the Beaudette strain of IBV was produced and purified from Escherichia coli as well as Sf9 ( insect) cells, and used for the coating of enzyme-linked immunosorbent assay ( ELISA) plates. The N protein produced in Sf9 cells was phosphorylated whereas N protein from E. coli was not. Our data indicated that N protein purified from E. coli was more sensitive to anti-IBV serum than the protein from Sf9 cells. The recombinant N protein did not react with the antisera to other avian pathogens, implying that it was specific in the recognition of IBV antibodies. In addition, the data from the detection of field samples and IBV strains indicated that using the recombinant protein as coating antigen could achieve an equivalent performance to an ELISA kit based on infected material extracts as a source of antigen(s). ELISAs based on recombinant proteins are safe ( no live virus), clean ( only virus antigens are present), specific ( single proteins can be used) and rapid ( to respond to new viral strains and strains that cannot necessarily be easily cultured).
Resumo:
Determination of varicella zoster virus (VZV) immunity in healthcare workers without a history of chickenpox is important for identifying those in need of vOka vaccination. Post immunisation, healthcare workers in the UK who work with high risk patients are tested for seroconversion. To assess the performance of the time-resolved fluorescence immunoassay (TRFIA) for the detection of antibody in vaccinated as well as unvaccinated individuals, a cut-off was first calculated. VZV-IgG specific avidity and titres six weeks after the first dose of vaccine were used to identify subjects with pre-existing immunity among a cohort of 110 healthcare workers. Those with high avidity (≥60%) were considered to have previous immunity to VZV and those with low or equivocal avidity (<60%) were considered naive. The former had antibody levels ≥400mIU/mL and latter had levels <400mIU/mL. Comparison of the baseline values of the naive and immune groups allowed the estimation of a TRFIA cut-off value of >130mIU/mL which best discriminated between the two groups and this was confirmed by ROC analysis. Using this value, the sensitivity and specificity of TRFIA cut-off were 90% (95% CI 79-96), and 78% (95% CI 61-90) respectively in this population. A subset of samples tested by the gold standard Fluorescence Antibody to Membrane Antigen (FAMA) test showed 84% (54/64) agreement with TRFIA.
Resumo:
We present a new, power-free and flexible detection system named MCFphone for portable colorimetric and fluorescence quantitative sandwich immunoassay detection of prostate specific antigen (PSA). The MCFphone is composed by a smartphone integrated with a magnifying lens, a simple light source and a miniaturised immunoassay platform, the Microcapillary Film (MCF). The excellent transparency and flat geometry of fluoropolymer MCF allowed quantitation of PSA in the range 0.9 to 60 ng/ml with < 7 % precision in 13 minutes using enzymatic amplification and a chromogenic substrate. The lower limit of detection was further improved from 0.4 to 0.08 ng/ml in whole blood samples with the use of a fluorescence substrate. The MCFphone has shown capable of performing rapid (13 to 22 minutes total assay time) colorimetric quantitative and highly sensitive fluorescence tests with good %Recovery, which represents a major step in the integration of a new generation of inexpensive and portable microfluidic devices with commercial immunoassay reagents and off-the-shelf smartphone technology.
Resumo:
Immunodiagnostic microneedles provide a novel way to extract protein biomarkers from the skin in a minimally invasive manner for analysis in vitro. The technology could overcome challenges in biomarker analysis specifically in solid tissue, which currently often involves invasive biopsies. This study describes the development of a multiplex immunodiagnostic device incorporating mechanisms to detect multiple antigens simultaneously, as well as internal assay controls for result validation. A novel detection method is also proposed. It enables signal detection specifically at microneedle tips and therefore may aid the construction of depth profiles of skin biomarkers. The detection method can be coupled with computerised densitometry for signal quantitation. The antigen specificity, sensitivity and functional stability of the device were assessed against a number of model biomarkers. Detection and analysis of endogenous antigens (interleukins 1α and 6) from the skin using the device was demonstrated. The results were verified using conventional enzyme-linked immunosorbent assays. The detection limit of the microneedle device, at ≤10 pg/mL, was at least comparable to conventional plate-based solid-phase enzyme immunoassays.
Resumo:
Nitric oxide synthase (NOS) inhibitors are largely used to evaluate the NO contribution to pulmonary allergy, but contrasting data have been reported. In this study, pharmacological, biochemical and pharmacokinetic assays were performed to compare the effects of acute and long-term treatment of BALB/C mice with the non-selective NOS inhibitor L-NAME in ovalbumin (OVA)-challenged mice. Acute L-NAME treatment (50 mg/kg, gavage) significantly reduced the eosinophil number in bronchoalveolar lavage fluid (BALF). The inducible NOS (iNOS) inhibitor aminoguanidine (20 mg/kg/day in the drinking water) also significantly reduced the eosinophil number in BALF In contrast, 3-week L-NAME treatment (50 and 150 mg/kg/day in the drinking water) significantly increased the pulmonary eosinophil influx. The constitutive NOS (cNOS) activity in brain and lungs was reduced by both acute and 3-week L-NAME treatments. The pulmonary iNOS activity was reduced by acute L-NAME (or aminoguanidine), but unaffected by 3-week L-NAME treatment. Acute L-NAME (or aminoguanidine) treatment was more efficient to reduce the NO(x) levels compared with 3-week L-NAME treatment. The pharmacokinetic study revealed that L-NAME is not bioavailable when given orally. After acute L-NAME intake, serum concentrations of the metabolite N(omega)-nitro-L-arginine decreased from 30 min to 24 h. In the 3-week L-NAME treatment, the N(omega)-nitro-L-arginine concentration was close to the detection limit. In conclusion, 3-week treatment with L-NAME yields low serum N(omega)-nitro-L-arginine concentrations, causing preferential inhibition of cNOS activity. Therefore, eosinophil influx potentiation by 3-week L-NAME treatment may reflect removal of protective cNOS-derived NO, with no interference on the ongoing inflammation due to iNOS-derived NO. (c) 2008 Elsevier Ltd. All rights reserved.
Resumo:
Neodymium based fluorescence presents several advantages in comparison to conventional rare earth or enzyme-substrate based fluorescence emitting sources (e.g.Tb, HRP). Based on this fact we have herein explored a Nd-based fluoroimmunoassay. We efficiently detected the presence of an oxidized low-density lipoprotein (oxLDL) in human plasma a well-known marker for cardiovascular diseases, which causes around 30% of deaths worldwide. Conventional fluoroimmunoassay uses time-resolved luminescence techniques, with detection in the visible range, to eliminate the fluorescence background from the biological specimens. By using an immunoassay based on functionalized Y(2)O(3):Nd(3+) nanoparticles, where the excitation and emission processes in the Nd(3+) ion occur in the near-infrared (NIR) region, we have succeeded in eliminating the interferences from the biological fluorescence background, avoiding the use of time-resolved techniques. This yields higher emission intensity from the Nd(3+)-nanolabels and efficient detection of anti-oxidized low-density lipoproteins (anti-oxLDL) by Y(2)O(3):Nd(3+)-antibody-antigen conjugation, leading to a novel biolabeling method. (C) 2010 Elsevier B.V. All rights reserved.
Resumo:
O presente trabalho estudou um ensaio imunoenzimático (ELISA) indireto para a detecção de anticorpos anti-Babesia canis no soro de cães, tendo a Reação de Imunofluorescência Indireta (RIFI), como teste de referência O antígeno utilizado no ELISA do presente estudo consistiu em uma preparação antigênica solúvel de merozoítas B. canis e as diluições ótimas do antígeno, soros e conjugado foram determinadas por titulação em bloco, utilizando soros de referência positivos e negativos. A preparação antigênica solúvel de B. canis ótima foi de 10 µg.mL-1, com soros de referência positivos e negativos em uma única diluição de 1:100, e conjugado a 1:4.000. Um total de 246 amostras séricas foram colhidas em cães, durante a campanha de vacinação anti-rábica em Jaboticabal, São Paulo, Brasil e a presença de anticorpos anti-B. canis foi avaliada pelo ELISA e RIFI. Nestas condições, a média de absorbância dos soros de referência negativos foi de 0,129 ± 0,025, resultando em um ponto de corte de 0,323 (Nível de ELISA 3) e a média da absorbância dos soros de referência positivos foi de 2,156 ± 1,187. As amostras com sorologia positiva para B. canis por ELISA e RIFI foram 67,89% (n = 167) e 59,35% (n = 146), respectivamente. Os resultados obtidos sugerem que o ELISA descrito revelou-se um teste sorológico eficaz no diagnóstico da babesiose canina.
Resumo:
A Saccharomyces cerevisiae-expressed nucleocapsid (N) polypeptide of the M41 strain of infectious bronchitis virus (IBV) was used as antigen in a recombinant yeast-expressed N protein-based enzyme-linked immunosorbent assay (Y-N-ELISA). The Y-N-ELISA was rapid, sensitive, and specific for detecting chicken serum antibodies to IBV, and it compared favorably with a commercial ELISA.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Toxocara vitulorum, a nematode parasite in the small intestine of cattle and water buffaloes, causes high morbidity and mortality of 1-3 months old buffalo calves. This research evaluated the specific perieneteric antigens (Pe) reactivity of anti-T. vitulorum-Pe antibody (Tv-Pe-Ab) in both immune sera and colostrum from buffalo cows immediately post-partum from buffalo cows. The presence of Tv-Pe-Ab in sera of buffalo newborn calves was also examined at 1 day before and after suckling the colostrum as well as in sera from naturally infected calves at the beginning and peak of the maximum infection and then again during the period of rejection and post-rejection of the parasite. Pe antigens were characterized for Tv-Pe-Ab by SDS-PAGE and Western blot (WB). The SDS-PAGE showed that Pe contained nine protein bands (11, 14, 31, 38, 58, 76, 88,112 and 165 kDa). All Pe bands were recognized by Tv-Pe-Ab in sera and colostrum of buffalo cows. Only the serum antibodies of buffalo calves at 1 day of age after suckling the colostrum and during the beginning of T. vitulorum infection recognized Pe antigen's nine bands. In contrast, serum antibodies from 1-day-old buffalo calves, taken before suckling colostrum, did not react with any protein band. In suckling calves, which reached peak egg output, rejection and post-rejection stages of the infection, serum Tv-Pe-Ab reactivity with lower molecular weight protein bands (11-76 kDa) was lost and only reactivity with the Pe protein bands of higher molecular weight (88, 112 and 165 kDa) remained. (c) 2005 Elsevier B.V. All rights reserved.
Resumo:
We compared saline (S) and sodium dodecyl sulphate (SDS) extracts from Taenia solium (homologous species - HO) and Taenia crassiceps (heterologous species - HE) metacestodes in order to detect Ige by ELISA and immunoblot assay (IBA) in cerebrospinal fluid (CSF) for the diagnosis of human neurocysticercosis (NC). CSF samples were obtained from 93 patients. of these, 40 had NC, five had a diagnosis of probable NC, nine had central nervous system schistosomiasis or strongyloidiasis and 39 had other neurological alterations. Samples were analysed by ELISA and the results were compared with IBA in all samples with confirmed and probable NC diagnosis, in all samples with other central nervous system parasitic infection, and in 10 of those with another neurological alterations. ELISA sensitivity was 100%, 85%, 95% and 87.5% for the S-HO, S-HE, SDS-HO and SDS-HE extracts, respectively, and ELISA specificity was 100% for S-HO, S-HE, SDS-HO extracts and 97.9% for SDS-HE antigen. Immunodominant peptides detected by IBA were, by decreasing percentage of recognition: 64-68 and 45 kDa for S-HO; 108-114, 92-95, 64-68, 83 and 88 kDa for S-HE; 64-68, 108-114, 77 and 86 kDa for SDS-HO; and 108-114, 88 and 92-95 kDa for SDS-HE. Overall the homologous antigenic extracts showed higher sensitivity than the heterologous extracts in the diagnosis of NC in CSF samples. The heterologous extracts contained most of the immunodominant peptides presented in the homologous extracts, which are recognized by Ige antibodies in CSF samples.